Attachments_02_through_05.docx
DOCX document 29 KB Posted
- Attached to
- Water Treatment Services Federal contract opportunity
- Solicitation number
- M00146-16-T-X001
- Issued by
- United States Marine Corps
About this file
Attachments 02 through 05
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| VENDOR_SUBMITTED_QUESTIONS.pdf | ||
| M00146-16-T-X001_0002.doc | DOC document | |
| M00146-16-T-X001_0001.doc | DOC document | |
| M00146-16-T-X001.doc | DOC document | |
| Attachment_01_PE-17806M_1-1_REV-E.PDF | ||
| Attachment_07_ASO_5560.6_Visit_Request_NEW.pdf | ||
| Attachment_06_Wage_Determination.txt | TXT text file |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOWLRWXD12541
MAKEUP WATER ANALYSIS
and MAXIMUM and MINIMUM CONTROL RANGES
SAMPLE LOCATION AND DESCRIPTION: ____________________________________________ ______________________________________________________________________________
DATE SAMPLED: ___________________ REPORT DATE: _____________________________
COLLECTED BY: _______________________________________________________________
| PARAMETER |
| READING |
| MAXIMUM CONTROL RANGE FOR * ITEMS |
| MINIMUM CONTROL RANGE FOR * ITEMS |
HARDNESS
CHLORIDES
| * |
| * |
ALKALINITY
DISSOLVED SOLIDS
| * |
| * |
pH
| * |
| * |
CONDUCTIVITY
IRON
ADDITIONAL ITEMS REQUIRING CONTROL RANGE
| MAXIMUM CONTROL RANGE |
| MINIMUM CONTROL RANGE |
CYCLES OF CONCENTRATION
CHEMICAL TREATMENT RESIDUALS
ATTACHMENT 02
WATER ANALYSIS and SERVICE REPORT
(OL - OPEN LOOP SYSTEM)
HYDRONIC SYSTEM CODE: ____________________
COMPANY: _________________________________________
COPIES TO: ___________________________ SERVICE ENGINEER: __________________
| ANALYSIS |
| LIMITS |
| Date |
Date Date Date Date Date
Chlorides
Hardness
Conductivity
TDS
pH
Inhibitor
Cycles of Concentration
| PRODUCT |
| INVENTORY |
Water Analysis and Service Report Comments Date __/__
ATTACHMENT 03
(CCL and HCL - CLOSED LOOP SYSTEM)
HYDRONIC SYSTEM CODE: _________________
COMPANY: _________________________________________ DATE:_____________________
| ANALYSIS |
| LIMITS |
| Date |
Date Date Date Date Date
Nitrite
Iron pH
| PRODUCT |
| INVENTORY |
Water Analysis and Service Report Comments
ATTACHMENT 04
(CCLG - CLOSED LOOP with GLYCOL SYSTEM)
HYDRONIC SYSTEM CODE:_____________
COMPANY: _________________________________________
| ANALYSIS |
| LIMITS |
| Date |
Date Date Date Date Date
Nitrite
Iron pH
| Percent Glycol |
| 40% to 60% |
PRODUCT
INVENTORY
Water Analysis and Service Report Comments
ATTACHMENT 05