This file comprises architectural and engineering plans prepared by Lamont Engineers & Planners for the Schoharie County Garage's Lehman Block Building restoration project, located at 102 RT 10, Sharon Springs, New York 13459. The plans detail existing conditions and proposed upgrades to the historic storefront, including five drawing sheets: existing front and back elevations, existing side elevations, proposed front view upgrades, proposed first floor upgrades, and cover notes. The project scope involves installation of new energy-efficient windows and doors designed to match the historical facade, removal and replication of existing historical storefront walls, replacement of exterior lighting, new siding to match existing materials, and exterior painting. The plans were issued for code review on August 14, 2024, with initial drawing completion dated July 19, 2024.
The architectural documentation specifies that plumbing, electrical, and HVAC design are to be completed by others and that the plans are designated for building permit purposes only. The project is part of a larger NY Forward Program rehabilitation initiative funded through an Empire State Development grant. The plans emphasize strict adherence to historical facade requirements while incorporating modern energy-efficient materials and components. All drawings bear the professional engineer stamp of BJB and are subject to New York State Education Law protections regarding unauthorized alteration or reuse on other projects.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP Lehman BlockvF.pdf | ||
| Lehman Storefront.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
E
D
C
B
A
F
E
D
C
B
A
87654321
87654321
Checked By
Designed By
Date
Drawn By
Scale
Lamont
ENGINEERS - PLANNERS
197 ELM ST., COBLESKILL, NY 12043
Engineers
FACILITY OPERATIONS
(518) 234-4028 www.lamontengineers.com
Consultant
Sheet No.
Sheet Title
Project Number
File Name
Stamp
UNAUTHORIZED ALTERATION AND/OR
ADDITION TO THIS DOCUMENT
AND/OR UNAUTHORIZED USE OR
REUSE OF THIS DOCUMENT ON A
PROJECT OTHER THAN THAT
INDICATED ON THIS DOCUMENT IS A
VIOLATION OF THE NEW YORK STATE
EDUCATION LAW AND THE CONTRACT
FOR PROFESSIONAL SERVICES AND IS
THEREFORE PROHIBITED.
N E W
Y O R K
S
TA
TE
6/ 9/
0:
:3
AM
K A P P S S D S K P R O J\ R ev it A d el p h i P a p er .r te
C10
COVER &
NOTES
2020095
R T
S H A R O N
S P R
IN
G S N Y
A D E
LP
H I P A P E R
07/19/2024
MFW
BJB
ZF
S C H O H A R
IE
C O U N
TY
GARAGE
IS
S U E
R E V
D A
TE
R E M A R K S
A
FO
R
C O D
ES
ADELPHI PAPER
102 RT 10
SHARON SPRINGS, NY 13459
NONE
NOTE:
PLANS FOR BUILDING PERMIT ONLY, PLUMBING, ELECTRICAL & HVAC DESIGN BY OTHERS.
DRAWING LIST
C10 COVER & NOTES
A120 EXISTING FRONT & BACK ELEVATIONS
A121 EXISTING SIDE ELEVATIONS
A122 PROPOSED FRONT VIEW UPGRADES
A123 PROPOSED FIRST FLOOR UPGRADES
C10
1 ISOMETRIC VIEW
BBecker
BJB PE STAMP
FIRST FLOOR
0' - 6"
SECOND FLOOR
13' - 0"
RIDGE VENT
F
E
D
C
B
A
F
E
D
C
B
A
87654321
87654321
Checked By
Designed By
Date
Drawn By
Scale
Lamont
ENGINEERS - PLANNERS
197 ELM ST., COBLESKILL, NY 12043
Engineers
FACILITY OPERATIONS
(518) 234-4028 www.lamontengineers.com
Consultant
Sheet No.
Sheet Title
Project Number
File Name
Stamp
UNAUTHORIZED ALTERATION AND/OR
ADDITION TO THIS DOCUMENT
AND/OR UNAUTHORIZED USE OR
REUSE OF THIS DOCUMENT ON A
PROJECT OTHER THAN THAT
INDICATED ON THIS DOCUMENT IS A
VIOLATION OF THE NEW YORK STATE
EDUCATION LAW AND THE CONTRACT
FOR PROFESSIONAL SERVICES AND IS
THEREFORE PROHIBITED.
N E W
Y O R K
S
TA
TE
1/4" = 1'-0"
6/ 9/
0:
:5
AM
K A P P S S D S K P R O J\ R ev it A d el p h i P a p er .r te
A120
EXISTING
FRONT &
BACK
ELEVATIONS
2020095
R T
S H A R O N
S P R
IN
G S N Y
A D E
LP
H I P A P E R
07/19/2024
MFW
BJB
ZF
S C H O H A R
IE
C O U N
TY
GARAGE
IS
S U E
R E V
D A
TE
R E M A R K S
A
FO
R
C O D
ES
1/4" = 1'-0"A120
2 BACK SIDE / SIDE B
1/4" = 1'-0"A120
1 FRONT VIEW / SIDE A
SECOND FLOOR
13' - 0"
F
E
D
C
B
A
F
E
D
C
B
A
87654321
87654321
Checked By
Designed By
Date
Drawn By
Scale
Lamont
ENGINEERS - PLANNERS
197 ELM ST., COBLESKILL, NY 12043
Engineers
FACILITY OPERATIONS
(518) 234-4028 www.lamontengineers.com
Consultant
Sheet No.
Sheet Title
Project Number
File Name
Stamp
UNAUTHORIZED ALTERATION AND/OR
ADDITION TO THIS DOCUMENT
AND/OR UNAUTHORIZED USE OR
REUSE OF THIS DOCUMENT ON A
PROJECT OTHER THAN THAT
INDICATED ON THIS DOCUMENT IS A
VIOLATION OF THE NEW YORK STATE
EDUCATION LAW AND THE CONTRACT
FOR PROFESSIONAL SERVICES AND IS
THEREFORE PROHIBITED.
N E W
Y O R K
S
TA
TE
1/4" = 1'-0"
6/ 9/
0:
:1
AM
K A P P S S D S K P R O J\ R ev it A d el p h i P a p er .r te
A121
EXISTING SIDE
ELEVATIONS
2020095
R T
S H A R O N
S P R
IN
G S N Y
A D E
LP
H I P A P E R
07/19/2024
MFW
BJB
ZF
S C H O H A R
IE
C O U N
TY
GARAGE
IS
S U E
R E V
D A
TE
R E M A R K S
A
FO
R
C O D
ES
1/4" = 1'-0"A121
3 RIGHT SIDE / SIDE D-D
1/4" = 1'-0"A121
4 LEFT SIDE / SIDE C-C
NEW WINDOW
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT
NEW WINDOW
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT
NEW DOOR / SWINGS OUT / RIGHT HAND SWING
THE DOORS NEED TO FOLLOW THE HISTORICAL FACADE,
BUT NEED TO BE ENERGY EFFICIENT.
NEW WALL - REPLICATE DESIGN FROM EXISTING WALL STORE FRONT
NEW REPLACEMENT WINDOWS
ENTIRE STORE FRONT
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT.
NEW REPLACEMENT WINDOWS
ENTIRE STORE FRONT
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT.
NEW REPLACEMENT DOORS
THE DOORS NEED TO FOLLOW
THE HISTORICAL FACADE.
REPLACE EXISTING LIGHT
F
E
D
C
B
A
F
E
D
C
B
A
87654321
87654321
Checked By
Designed By
Date
Drawn By
Scale
Lamont
ENGINEERS - PLANNERS
197 ELM ST., COBLESKILL, NY 12043
Engineers
FACILITY OPERATIONS
(518) 234-4028 www.lamontengineers.com
Consultant
Sheet No.
Sheet Title
Project Number
File Name
Stamp
UNAUTHORIZED ALTERATION AND/OR
ADDITION TO THIS DOCUMENT
AND/OR UNAUTHORIZED USE OR
REUSE OF THIS DOCUMENT ON A
PROJECT OTHER THAN THAT
INDICATED ON THIS DOCUMENT IS A
VIOLATION OF THE NEW YORK STATE
EDUCATION LAW AND THE CONTRACT
FOR PROFESSIONAL SERVICES AND IS
THEREFORE PROHIBITED.
N E W
Y O R K
S
TA
TE
1/4" = 1'-0"
6/ 9/
0:
:5
AM
K A P P S S D S K P R O J\ R ev it A d el p h i P a p er .r te
A122
PROPOSED
FRONT VIEW
UPGRADES
2020095
R T
S H A R O N
S P R
IN
G S N Y
A D E
LP
H I P A P E R
07/19/2024
MFW
BJB
ZF
S C H O H A R
IE
C O U N
TY
GARAGE
IS
S U E
R E V
D A
TE
R E M A R K S
A
FO
R
C O D
ES
1/4" = 1'-0"A122
1 FRONT VIEW - UPGRADES
A122
2 FRONT UPGRADE ISOMETRIC VIEW
DN
DN 1'-2"
NEW DOOR
3'-2"
NEW SIDING TO MATCH EXISTING
11'-10"
NEW WINDOW
7'-0"0'-3" 1'-5"
NEW WINDOW
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT
NEW WINDOW
THE WINDOW NEED TO FOLLOW
THE HISTORICAL FACADE, BUT
NEED TO BE ENERGY EFFICIENT
F
E
D
C
B
A
F
E
D
C
B
A
87654321
87654321
Checked By
Designed By
Date
Drawn By
Scale
Lamont
ENGINEERS - PLANNERS
197 ELM ST., COBLESKILL, NY 12043
Engineers
FACILITY OPERATIONS
(518) 234-4028 www.lamontengineers.com
Consultant
Sheet No.
Sheet Title
Project Number
File Name
Stamp
UNAUTHORIZED ALTERATION AND/OR
ADDITION TO THIS DOCUMENT
AND/OR UNAUTHORIZED USE OR
REUSE OF THIS DOCUMENT ON A
PROJECT OTHER THAN THAT
INDICATED ON THIS DOCUMENT IS A
VIOLATION OF THE NEW YORK STATE
EDUCATION LAW AND THE CONTRACT
FOR PROFESSIONAL SERVICES AND IS
THEREFORE PROHIBITED.
N E W
Y O R K
S
TA
TE
3/8" = 1'-0"
6/ 9/
0:
:4
AM
K A P P S S D S K P R O J\ R ev it A d el p h i P a p er .r te
A123
PROPOSED
FIRST FLOOR
UPGRADES
2020095
R T
S H A R O N
S P R
IN
G S N Y
A D E
LP
H I P A P E R
07/19/2024
MFW
BJB
MFW
S C H O H A R
IE
C O U N
TY
GARAGE
IS
S U E
R E V
D A
TE
R E M A R K S
A
FO
R
C O D
ES
3/8" = 1'-0"A123
1 FIRST FLOOR UPGRADES
| Sheets |
| A120 - EXISTING FRONT & BACK ELEVATIONS |
| A121 - EXISTING SIDE ELEVATIONS |
| A122 - PROPOSED FRONT VIEW UPGRADES |
| A123 - PROPOSED FIRST FLOOR UPGRADES |
| C10 - COVER & NOTES |
| Adelphi Paper - Sheet - A120 - EXISTING FRONT & BACK ELEVATIONS.pdf |
| Sheets |
| A120 - EXISTING FRONT & BACK ELEVATIONS |
| A121 - EXISTING SIDE ELEVATIONS |
| A122 - PROPOSED FRONT VIEW UPGRADES |
| A123 - PROPOSED FIRST FLOOR UPGRADES |
| C10 - COVER & NOTES |
| Adelphi Paper - Sheet - A121 - EXISTING SIDE ELEVATIONS.pdf |
| Sheets |
| A120 - EXISTING FRONT & BACK ELEVATIONS |
| A121 - EXISTING SIDE ELEVATIONS |
| A122 - PROPOSED FRONT VIEW UPGRADES |
| A123 - PROPOSED FIRST FLOOR UPGRADES |
| C10 - COVER & NOTES |
| Adelphi Paper - Sheet - A122 - PROPOSED FRONT VIEW UPGRADES.pdf |
| Sheets |
| A120 - EXISTING FRONT & BACK ELEVATIONS |
| A121 - EXISTING SIDE ELEVATIONS |
| A122 - PROPOSED FRONT VIEW UPGRADES |
| A123 - PROPOSED FIRST FLOOR UPGRADES |
| C10 - COVER & NOTES |
| Adelphi Paper - Sheet - A123 - PROPOSED FIRST FLOOR UPGRADES.pdf |
| Sheets |
| A120 - EXISTING FRONT & BACK ELEVATIONS |
| A121 - EXISTING SIDE ELEVATIONS |
| A122 - PROPOSED FRONT VIEW UPGRADES |
| A123 - PROPOSED FIRST FLOOR UPGRADES |
| C10 - COVER & NOTES |
File details come from the government source that posted it. Updated .