ITB-W-1148 A3.pdf
PDF 6 MB Posted
- Attached to
- Van Dyke Mixed Use Rehabilitation Project State and local contract opportunity
- Solicitation number
- ITB-W-1148
- Issued by
- Macomb County, Westland City, Michigan
About this file
This document is Addendum No. 3 for the City of Warren Tax Increment Finance Authority (TIFA) Van Dyke Mixed-Use Rehabilitation Project, dated March 28, 2024. The addendum provides updates and clarifications to the original bid documents, including revisions to specification sections for material finish/color schedule, gypsum cement underlayment, door hardware, and gypsum board. A supplementary pre-bid walkthrough is scheduled for April 2nd at 9:00 am at the project site, intended for subcontractors to review existing building conditions. While attendance is not mandatory, general contractors were required to have attended one of the two previous pre-bid meetings held on March 15th and 18th.
The addendum includes modifications to various technical specifications and drawings, such as adding a sound control mat and self-leveling gypsum board underlayment, incorporating fire-rated gypsum board for the first-floor ceiling assembly, and updating electrical specifications to apply energy code performance requirements only to commercial spaces. The document also provides detailed hardware schedules for different door types, specifying manufacturers, finishes, and specific hardware components. Pre-bid requests for information (RFIs) have been addressed, including clarifications about HVAC unit controls and thermostat requirements. The addendum is accompanied by pre-bid meeting sign-in sheets and aims to provide comprehensive guidance for potential bidders on the rehabilitation project.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| ITB-W-1148 Exhibit A - Prevailing Wage Rates.pdf | ||
| ITB-W-1148 Drawings.pdf | ||
| ITB-W-1148 A2 Asbestos Abatement Report.pdf | ||
| ITB-W-1148 A2.pdf | ||
| ITB-W-1148.pdf | ||
| ITB-W-1148 A1.pdf | ||
| ITB-W-1148 A2 Pre-Renovation HMS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
City of Warren TIFA Van Dyke Mixed-Use Rehabilitation Addendum No. 3 3/28/2024
ADDENDUM
Project Name: City of Warren TIFA Addendum No: Three (3)
Van Dyke Mixed-Use Rehabilitation
Project Number: 22-149 Issue Date: March 28, 2024 Project Location: Warren, MI
This Addendum forms a part of the above-described Contract Documents and supersedes, supplements or clarifies parts thereof to the extent defined by the terms set forth in this Addendum.
This Addendum consists of (2) typed pages and the following (12) attachments:
Specification Sections: Section 000200 – Material Finish / Color Schedule Section 035413 – Gypsum Cement Underlayment Section 087100 – Door Hardware Section 092900 – Gypsum Board
Drawings: A0-04, MP0-02, MP1-01, E0-02, E0-03, E2-01
Other Attachments: Pre-Bid Meeting Sign-In Sheets from 3/15 and 3/18 meetings.
SUPPLEMENTARY PRE-BID WALKTHROUGH (Revising section 000000 – Advertisement for Bids): A Supplementary Pre-Bid Walkthrough will be held on Tuesday, April 2nd at 9:00 am at the Project Site, 23150 Van Dyke Ave, Warren, MI. This walkthrough is intended for the subcontractors of bidding General Contractors to review the existing building conditions.
Attendance is not mandatory. Note, General Contractors wishing to submit a bid are required to have attended one of the two prior Pre-Bid Meetings held on March 15th and 18th; attendance at this walkthrough alone will not suffice as having met the requirement.
PRE-BID RFIS:
RFI #1 Question: I see the RTU schedule notes control drawings (note L) to reference unit controls but I cannot seem to find the associated control drawings. Are they on another drawing perhaps? Or is the unit packaged controls with a thermostat? (note N).
Response: Refer to revised drawing MP1-01 – Note L on the Rooftop HVAC Unit Schedule is not applicable to this project. Provide a thermostat per Note N.
SPECIFICATIONS:
ITEM SP1 Section 000200 – Material Finish / Color Schedule (New Section)
ITEM SP2 Section 035413 – Gypsum Cement Underlayment (New Section) A. Added specification section to include sound control mat and self-leveling, gypsum board underlayment below second floor finish flooring as indicated on the drawings, to provide required fire rating and enhance acoustical performance of the floor assembly.
ITEM SP3 Section 087100 – Door Hardware (New Section)
City of Warren TIFA Van Dyke Mixed-Use Rehabilitation Addendum No. 3 3/28/2024 ITEM SP4 Section 092900 – Gypsum Board (Revised and Reissued)
A. Added sections 2.3 and 3.1.B to include “Specialty Gypsum Board Type C” and installation of the same, for use in the first-floor ceiling assembly as indicated on the drawings.
ARCHITECTURAL DRAWINGS:
ITEM A1 A0-04 – Wall Types & Opening Details (Revised & Reissued) A. Added UL design details.
MECHANICAL DRAWINGS:
ITEM M1 MP0-02 – Mechanical Specifications (Revised & Reissued) A. Added fire protection specifications.
ITEM M2 MP1-01 – Mechanical Schedules (Revised & Reissued) A. Key note ‘L’ removed from HVAC-1 on the Rooftop HVAC Unit Schedule.
ELECTRICAL DRAWINGS:
ITEM E1 E0-02 – Electrical Specifications (Revised & Reissued) A. Energy Code Performance-based specification noted to apply only to commercial spaces.
B. Revised Electrical Equipment and Devices section.
C. Removed Fire Alarm section.
ITEM E2 E0-03 – Riser Diagram (Revised & Reissued) A. Revised RP-A panel schedule.
ITEM E3 E2-01 – Power Floor Plans (Revised & Reissued) A. Added key note A3, indicating to provide a limited function fire alarm monitoring the fire sprinkler system and located on plan.
B. Added receptacles in Mud Room 110 and Future Office / Assembly 106.
C. Added note regarding overhead door openers.
D. Revised receptacles in Kitchen / Dining 201.
E. Added receptacle at HVAC-1.
**END OF ADDENDUM**
MATERIAL FINISH / COLOR SCHEDULE PARTNERS 22-149
MATERIAL SCHEDULE
000200 - 1
Spec
Section
Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)
042000
FB-1 New Face Brick Belden Brick Company To match existing bark-texture existing brick
Size: Standard
TB-1 Thin Brick Belden Brick Company Color: To be selected
Size: Modular
TB-2 Thin Brick Belden Brick Company Color: To be selected
Size: Modular
Mortar at Existing & New Full-Depth
Brick
Color: Custom match to existing mortar color.
Mortar at Thin Brick Color: To be selected
047200
CS-1 Cast Stone Sills Color: To be selected
073113
Asphalt Shingles CertainTeed
173113
Siding James Hardie
Plank Lap Siding - Smooth
Color: To be selected from manufacturer's standard range.
Trim Boards James Hardie
5/4 Smooth Trim
Color: To be selected from manufacturer's standard range.
ASPHALT SHINGLES
FIBER CEMENT SIDING
UNIT MASONRY
CAST STONE MASONRY
MARCH 28, 2024 / ADDENDUM 3
MATERIAL FINISH / COLOR SCHEDULE PARTNERS 22-149
MATERIAL SCHEDULE
000200 - 2
Spec
Section
Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)
099113
PNT-1 Exterior Paint Sherwin-Williams Color: To be selected Exterior CMU
PNT-2 Exterior Paint Sherwin-Williams Color: To be selected Exterior CMU -
Neighboring Building
PNT-3 Exterior Paint Sherwin-Williams Color: To be selected Exterior CMU -
Neighboring Building
PNT-4 Exterior Paint Sherwin-Williams Color: To be selected Exterior steel lintels
102113.17
Toilet Partitions ASI Color: To be selected First floor gang restrooms
PHENOLIC TOILET COMPARTMENTS
EXTERIOR PAINTING
PARTNERS 22-149
GYPSUM CEMENT UNDELAYMENT
035413 - 1
SECTION 035413 - GYPSUM CEMENT UNDERLAYMENT
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Sound control mat for horizontal applications.
2. Self-leveling, gypsum cement underlayment for application below interior floor coverings.
1.2 PREINSTALLATION MEETINGS
A. Preinstallation Conference: Conduct conference at Project site.
1.3 ACTION SUBMITTALS
A. Product Data: For the following:
1. Sound control mat.
2. Gypsum cement underlayment.
1.4 QUALITY ASSURANCE
A. Installer Qualifications: Installer who is approved by manufacturer for application of underlayment products required for this Project.
1.5 FIELD CONDITIONS
A. Environmental Limitations: Comply with manufacturer's written instructions for substrate temperature, ventilation, ambient temperature and humidity, and other conditions affecting underlayment performance.
1. Place gypsum cement underlayment’s only when ambient temperature and temperature of substrates are between 50 and 80 deg F (10 and 27 deg C).
PART 2 - PRODUCTS
2.1 GYPSUM BOARD UNDERLAYMENT FIRE RATED ASSEMBLY
A. Provide Gypsum board underlayment fire rated assembly designed for use above structural framing and below finish flooring using products from the same manufacturer and meeting material and installation requirements included in Under Writer Laboratories Design No. L583 System No. 3.
035413 - 2
2.2 SOUND CONTROL MAT
A. Materials: Sound control mat.
1. Basis-of-Design Sound Control Mat: Provide products as manufactured by Hacker Industries, Inc., “FIRM-FILL® Gypsum Concrete, SCM 125 Sound Control Mat” or, subject to compliance with requirements products listed below:
a. USG SAM-N12.
2. Roll Weight: 33 lbs.
3. Thickness: 1/8-inch.
2.3 GYPSUM CEMENT UNDERLAYMENT
A. Materials: Self-leveling, gypsum cement.
1. Basis-of-Design Gypsum Cement Underlayment: Provide products as manufactured by Hacker Industries, Inc. or, subject to compliance with requirements products listed below:
a. USG Levelrock.
2. Sand: Well graded washed plaster, masonry sand or concrete sand, meeting the requirement so ASTM C33, and Hacker Industries, Inc., “Sand Guidelines.”
3. Water: Potable and fee from impurities.
PART 3 - EXECUTION
3.1 PREPARATION
A. Prepare and clean substrate according to manufacturer's written instructions.
1. Subfloor must be structurally sound (L/360), broom clean, dry and free from oil, grease, paraffin, laitance, wax or other contaminants before the arrival of the Hacker Licensed Applicator.
2. Leak Prevention: All cracks and voids shall be filled with a quick-setting patching or taping compound or equal where leakage could occur.
3. Before installation, the General Contractor (GC) shall inspect and approve the condition of the subfloor, and test the existing subfloor for moisture
B. Mixing Instructions: 6-7 gallons (22.7-26.5) of water and sand for every 80-pounds of FIRM-FILL® Gypsum Concrete as recommended by manufacturer.
3.2 INSTALLATION
A. Close areas to traffic during underlayment installation and for time period after installation recommended in writing by manufacturer.
035413 - 3
B. Coordinate installation of components to provide optimum adhesion to substrate.
C. Install sound control mat in accordance with manufacturers written instructions.
1. Lay mat flat with seams overlapping.
2. Seal joints with adhesive zip strip or approved tape.
3. Install manufactures isolation strip material along all walls. Staple isolation strip at corners and every 3-4 feet on center.
D. Mix FIRM-FILL® Gypsum Concrete in accordance to manufacturer’s recommendations.
E. Install underlayment to produce uniform, level surface.
F. Apply minimum ¾-inch thick layer of FIRM-FILL® Gypsum Concrete over sound control mat.
G. Cure underlayment according to manufacturer's written instructions:
1. Prevent contamination during installation and curing processes:
2. Provide continuous ventilation and adequate heat to rapidly remove moisture from the area until the underlayment is dry. Do not install finished floor coverings until the FIRM-FILL® Gypsum has been tested for dryness and acceptable moisture levels.
H. Do not install floor coverings over underlayment until after time period recommended in writing by underlayment manufacturer.
I. Remove and replace underlayment areas that evidence lack of bond with substrate, including areas that emit a "hollow" sound when tapped.
3.3 INSTALLATION TOLERANCES
A. Finish and measure surface, so gap at any point between gypsum cement underlayment surface and an unleveled, freestanding, 10-foot (3.05-m-) long straightedge resting on two high spots and placed anywhere on the surface does not exceed 1/8 inch (3 mm) and 1/16 inch (1.6 mm) in 2 feet (610 mm).
END OF SECTION 035413
DOOR HARDWARE
087100 - 1
SECTION 087100 - DOOR HARDWARE
PART 1 - GENERAL
1.01 SUMMARY
A. Section includes:
1. Mechanical and electrified door hardware
B. Section excludes:
1. Windows
2. Cabinets (casework), including locks in cabinets
3. Signage
4. Toilet accessories
5. Overhead doors
C. Related Sections:
1. Division 01 "General Requirements" sections for Allowances, Alternates, Owner Furnished Contractor Installed, Project Management and Coordination.
2. Division 06 Section ''Rough Carpentry''
3. Division 06 Section ''Finish Carpentry''
4. Division 07 Section ''Joint Sealants'' for sealant requirements applicable to threshold installation specified in this section.
5. Division 08 Sections:
a. ''Metal Doors and Frames''
b. ''Flush Wood Doors''
c. ''Stile and Rail Wood Doors''
d. ''Interior Aluminum Doors and Frames''
e. ''Aluminum-Framed Entrances and Storefronts''
f. ''Stainless Steel Doors and Frames''
g. ''Special Function Doors''
h. ''Entrances''
1.02 SUBMITTALS
A. General:
1. Submit in accordance with Conditions of Contract and Division 01 Submittal Procedures.
2. Prior to forwarding submittal:
a. Review drawings and Sections from related trades to verify compatibility with specified hardware.
b. Highlight, encircle, or otherwise specifically identify on submittals: deviations from Contract Documents, issues of incompatibility or other issues which may detrimentally affect the Work.
B. Action Submittals:
087100 - 2
1. Product Data: Submit technical product data for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements.
2. Samples for Verification: If requested by Architect, submit production sample of requested door hardware unit in finish indicated and tagged with full description for coordination with schedule.
a. Samples will be returned to supplier. Units that are acceptable to Architect may, after final check of operations, be incorporated into Work, within limitations of key coordination requirements.
3. Door Hardware Schedule:
a. Submit concurrent with submissions of Product Data, Samples, and Shop Drawings.
Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate fabrication of other work critical in Project construction schedule.
b. Submit under direct supervision of a Door Hardware Institute (DHI) certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) with hardware sets in vertical format as illustrated by Sequence of Format for the Hardware Schedule published by
DHI.
c. Indicate complete designations of each item required for each opening, include:
1) Door Index: door number, heading number, and Architect's hardware set number.
2) Quantity, type, style, function, size, and finish of each hardware item.
3) Name and manufacturer of each item.
4) Fastenings and other pertinent information.
5) Location of each hardware set cross-referenced to indications on Drawings.
6) Explanation of all abbreviations, symbols, and codes contained in schedule.
7) Mounting locations for hardware.
8) Door and frame sizes and materials.
9) Degree of door swing and handing.
4. Key Schedule:
a. After Keying Conference, provide keying schedule that includes levels of keying, explanations of key system's function, key symbols used, and door numbers controlled.
b. Use ANSI/BHMA A156.28 ''Recommended Practices for Keying Systems'' as guideline for nomenclature, definitions, and approach for selecting optimal keying system.
c. Provide 3 copies of keying schedule for review prepared and detailed in accordance with referenced DHI publication. Include schematic keying diagram and index each key to unique door designations.
d. Index keying schedule by door number, keyset, hardware heading number, cross keying instructions, and special key stamping instructions.
e. Provide one complete bitting list of key cuts and one key system schematic illustrating system usage and expansion. Forward bitting list, key cuts and key system schematic directly to Owner, by means as directed by Owner.
f. Prepare key schedule by or under supervision of supplier, detailing Owner's final keying instructions for locks.
C. Informational Submittals:
1. Provide Qualification Data for Supplier, Installer and Architectural Hardware Consultant.
2. Provide Product Data:
a. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.
087100 - 3
b. Include warranties for specified door hardware.
D. Closeout Submittals:
1. Operations and Maintenance Data: Provide in accordance with Division 01 and include:
a. Complete information on care, maintenance, and adjustment; data on repair and replacement parts, and information on preservation of finishes.
b. Catalog pages for each product.
c. Final approved hardware schedule edited to reflect conditions as installed.
d. Final keying schedule
e. Copy of warranties including appropriate reference numbers for manufacturers to identify project.
f. As-installed wiring diagrams for each opening connected to power, both low voltage and 110 volts.
E. Inspection and Testing:
1. Submit written reports to the Owner and Authority Having Jurisdiction (AHJ) of the results of functional testing and inspection for:
a. Fire door assemblies, in compliance with NFPA 80.
b. Required egress door assemblies, in compliance with NFPA 101.
1.03 QUALITY ASSURANCE
A. Qualifications and Responsibilities:
1. Supplier: Recognized architectural hardware supplier with a minimum of 5 years documented experience supplying both mechanical and electromechanical door hardware similar in quantity, type, and quality to that indicated for this Project. Supplier to be recognized as a factory direct distributor by the manufacturer of the primary materials with a warehousing facility in the Project’s vicinity. Supplier to have on staff, a certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) available to Owner, Architect, and Contractor, at reasonable times during the Work for consultation.
2. Installer: Qualified tradesperson skilled in the application of commercial grade hardware with experience installing door hardware similar in quantity, type, and quality as indicated for this Project.
3. Architectural Hardware Consultant: Person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and meets these requirements:
a. For door hardware: DHI certified AHC or DHC.
b. Can provide installation and technical data to Architect and other related subcontractors.
c. Can inspect and verify components are in working order upon completion of installation.
d. Capable of producing wiring diagram and coordinating installation of electrified hardware with
Architect and electrical engineers.
4. Single Source Responsibility: Obtain each type of door hardware from single manufacturer.
B. Certifications:
1. Fire-Rated Door Openings:
087100 - 4
a. Provide door hardware for fire-rated openings that complies with NFPA 80 and requirements of authorities having jurisdiction.
b. Provide only items of door hardware that are listed products tested by UL LLC, Intertek Testing Services, or other testing and inspecting organizations acceptable to authorities having jurisdiction for use on types and sizes of doors indicated, based on testing at positive pressure and according to NFPA 252 or UL 10C and in compliance with requirements of fire-rated door and door frame labels.
2. Smoke and Draft Control Door Assemblies:
a. Provide door hardware that meets requirements of assemblies tested according to UL 1784 and installed in compliance with NFPA 105
b. Comply with the maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at tested pressure differential of 0.3-inch wg (75 Pa) of water.
3. Accessibility Requirements:
a. Comply with governing accessibility regulations cited in ''REFERENCES'' article 087100, 1.02.D3 herein for door hardware on doors in an accessible route. This project must comply with all Federal Americans with Disability Act regulations and all Local Accessibility Regulations.
C. Pre-Installation Meetings
1. Keying Conference
a. Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including:
1) Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.
2) Preliminary key system schematic diagram.
3) Requirements for key control system.
4) Requirements for access control.
5) Address for delivery of keys.
2. Pre-installation Conference
a. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.
b. Inspect and discuss preparatory work performed by other trades.
c. Review required testing, inspecting, and certifying procedures.
d. Review questions or concerns related to proper installation and adjustment of door hardware.
1.04 DELIVERY, STORAGE, AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up for hardware delivered to Project site.
Promptly replace products damaged during shipping.
B. Tag each item or package separately with identification coordinated with final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package.
Deliver each article of hardware in manufacturer's original packaging.
C. Maintain manufacturer-recommended environmental conditions throughout storage and installation periods.
087100 - 5
D. Provide secure lock-up for door hardware delivered to Project. Control handling and installation of hardware items so that completion of Work will not be delayed by hardware losses both before and after installation.
E. Handle hardware in manner to avoid damage, marring, or scratching. Correct, replace or repair products damaged during Work. Protect products against malfunction due to paint, solvent, cleanser, or any chemical agent.
F. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.
1.05 COORDINATION
A. Coordinate layout and installation of floor-recessed door hardware with floor construction. Cast anchoring inserts into concrete.
B. Installation Templates: Distribute for doors, frames, and other work specified to be factory or shop prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.
C. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.
1.06 WARRANTY
A. Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within published warranty period.
1. Warranty does not cover damage or faulty operation due to improper installation, improper use or abuse.
2. Warranty Period: Beginning from date of Substantial Completion, for durations indicated in manufacturer's published listings.
1.07 MAINTENANCE
A. Furnish complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.
B. Turn over unused materials to Owner for maintenance purposes.
PART 2 - PRODUCTS
2.01 MANUFACTURERS
A. Approval of alternate manufacturers and/or products other than those listed as ''Scheduled Manufacturer'' or ''Acceptable Manufacturers'' in the individual article for the product category are only to be considered by official substitution request in accordance with section 01 25 00.
087100 - 6
B. Approval of products from manufacturers indicated in ''Acceptable Manufacturers'' is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer's product.
C. Where specified hardware is not adaptable to finished shape or size of members requiring hardware, furnish suitable types having same operation and quality as type specified, subject to Architect's approval.
2.02 MATERIALS
A. Fabrication
1. Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. provide screws according to manufacturer’s recognized installation standards for application intended.
2. Finish exposed screws to match hardware finish, or, if exposed in surfaces of other work, to match finish of this other work including prepared for paint surfaces to receive painted finish.
3. Provide concealed fasteners wherever possible for hardware units exposed when door is closed.
Coordinate with “Metal Doors and Frames”, “Flush Wood Doors”, “Stile and Rail Wood Doors” to ensure proper reinforcements. Advise the Architect where visible fasteners, such as thru bolts, are required.
B. Provide screws, bolts, expansion shields, drop plates and other devices necessary for hardware installation.
1. Where fasteners are exposed to view: Finish to match adjacent door hardware material.
2.03 HINGES
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Ives 5BB series
2. Acceptable Manufacturers and Products:
a. Hager BB1191/1279 series
b. Best FBB series
c. McKinney TB series
B. Requirements:
1. Provide hinges conforming to ANSI/BHMA A156.1.
2. Provide five knuckle, ball bearing hinges.
3. 1-3/4 inch (44 mm) thick doors, up to and including 36 inches (914 mm) wide:
a. Exterior: Standard weight, bronze or stainless steel, 4-1/2 inches (114 mm) high
b. Interior: Standard weight, steel, 4-1/2 inches (114 mm) high
4. 1-3/4 inch (44 mm) thick doors over 36 inches (914 mm) wide:
a. Exterior: Heavy weight, bronze/stainless steel, 5 inches (127 mm) high
087100 - 7
b. Interior: Heavy weight, steel, 5 inches (127 mm) high
5. 2 inches or thicker doors:
a. Exterior: Heavy weight, bronze or stainless steel, 5 inches (127 mm) high
b. Interior: Heavy weight, steel, 5 inches (127 mm) high
6. Adjust hinge width for door, frame, and wall conditions to allow proper degree of opening.
7. Provide three hinges per door leaf for doors 90 inches (2286 mm) or less in height, and one additional hinge for each 30 inches (762 mm) of additional door height.
8. Hinge Pins: Except as otherwise indicated, provide hinge pins as follows:
a. Steel Hinges: Steel pins
b. Non-Ferrous Hinges: Stainless steel pins
c. Out-Swinging Exterior Doors: Non-removable pins
d. Out-Swinging Interior Lockable Doors: Non-removable pins
e. Interior Non-lockable Doors: Non-rising pins
2.04 CONTINUOUS HINGES
A. Manufacturers:
1. Scheduled Manufacturer:
a. Ives
2. Acceptable Manufacturers:
a. Select
b. Hager
c. ABH
B. Requirements:
1. Provide aluminum geared continuous hinges conforming to ANSI/BHMA A156.26, Grade 1.
2. Provide aluminum geared continuous hinges, where specified in the hardware sets, fabricated from
6063-T6 aluminum.
3. Provide split nylon bearings at each hinge knuckle for quiet, smooth, self-lubricating operation.
4. Provide hinges capable of supporting door weights up to 450 pounds, and successfully tested for
1,500,000 cycles.
5. On fire-rated doors, provide aluminum geared continuous hinges classified for use on rated doors by testing agency acceptable to authority having jurisdiction.
6. Provide hinges 1 inch (25 mm) shorter in length than nominal height of door, unless otherwise noted or door details require shorter length and with symmetrical hole pattern.
2.05 CYLINDRICAL LOCKS – EXTERIOR DOORS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Falcon T series
2. Acceptable Manufacturers and Products:
087100 - 8
a. Sargent 10-Line
b. Best 9K series
B. Requirements:
1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 1, and UL Listed for 3-hour fire doors.
2. Cylinders: Refer to ''KEYING'' article, herein.
3. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with 1/2-inch latch throw. Provide proper latch throw for UL listing at pairs.
4. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.
5. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.
6. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.
7. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.
a. Lever Design: LAT
2.06 CYLINDRICAL LOCKS - INTERIOR DOORS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Falcon W series
2. Acceptable Manufacturers and Products:
a. Sargent 6500 series
b. Best 73KC series
B. Requirements:
1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 2, and UL Listed for 3-hour fire doors.
2. Cylinders: Refer to ''KEYING'' article, herein.
3. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with 1/2-inch latch throw. Provide proper latch throw for UL listing at pairs.
4. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.
5. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.
6. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.
7. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.
a. Lever Design: LAT
2.07 TUBULAR LOCKS – UNIT DOORS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Schlage F series
087100 - 9
2. Acceptable Manufacturers and Products:
a. Sargent DL series
b. Dormakaba QTL200 series
B. Requirements:
1. Provide tubular locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 2, Grade 2 and ANSI/BHMA A156.39 Residential Grade AAA, and UL Listed for 3-hour fire doors.
2. Cylinders: Refer to ''KEYING'' article, herein.
3. Provide locks with standard 2-3/8 inches (60 mm) adjustable to 2-3/4 inches (70 mm) backset with
1/2-inch (13 mm) latch throw. Provide 2-3/4 inches (70 mm) backset, unless 2-3/8 inches (60 mm) is required by door or frame detail or noted otherwise.
4. Provide locksets that fit standard 2-1/8 inches (54 mm) diameter bore without use of thru bolts.
5. Door Thickness: Locksets adjustable to fit in 1-3/8 inches (35 mm) or 1-3/4 inches (44 mm) door thickness.
6. Provide standard T-strikes unless extended lip strikes are necessary to protect trim.
7. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.
a. Lever Design: LAT
2.08 DEADBOLTS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Schlage B500 Series
2. Acceptable Manufacturers and Products:
a. Sargent 470 Series
b. Dormakaba D800/DB600 Series
B. Requirements:
1. Provide grade 2 deadbolt series conforming to ANSI/BHMA A156.
2. Cylinders: Refer to ''KEYING'' article, herein.
3. Provide deadbolts with standard 2-3/4 inches (70 mm) backset. Provide 2-3/8 inches (60 mm) where noted or if door or frame detail requires. Provide deadbolt with full 1-inch (25 mm) throw, constructed of steel alloy.
4. Provide manufacturer's standard strike.
5. Lock Status Indicator Trim: Where specified, provide escutcheon with lock status indicator widow.
a. Escutcheon height 4.125 inches, width 2.54 inches. Projection 1.32 inches on thumbturn side and 1.28 inches on cylinder side.
b. Unlocked and Unoccupied message will display on white background, and Locked and Occupied message will display on red background.
c. Provide snap-in serviceable window to prevent tampering. Lock must function if indicator is compromised.
d. Indicator window to provide 180-degree visibility.
2.09 EXIT DEVICES
087100 - 10
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Falcon 24/25 series
2. Acceptable Manufacturers and Products:
a. Sargent 19-43-GL-80 series
b. Precision Apex series
B. Requirements:
1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1 and UL listed for Panic Exit or Fire Exit Hardware.
2. Cylinders: Refer to ''KEYING'' article, herein.
3. Provide touchpad type exit devices, fabricated of brass, bronze, stainless steel, or aluminum, plated to standard architectural finishes to match balance of door hardware.
4. Touchpad must extend a minimum of one half of door width. No plastic inserts are allowed in touchpads.
5. Provide exit devices with deadlatching feature for security and for future addition of alarm kits and/or other electrified requirements.
6. Provide flush end caps for exit devices.
7. Provide exit devices with manufacturer's approved strikes.
8. Provide exit devices cut to door width and height. Install exit devices at height recommended by exit device manufacturer, allowable by governing building codes, and approved by Architect.
9. Mount mechanism case flush on face of doors or provide spacers to fill gaps behind devices.
Where glass trim or molding projects off face of door, provide glass bead kits.
10. Provide cylinder or hex-key dogging as specified at non fire-rated openings.
11. Removable Mullions: 2 inches (51 mm) x 3 inches (76 mm) steel tube. Where scheduled as keyed removable mullion, provide type that can be removed by use of a keyed cylinder, which is self-locking when re-installed.
12. Provide factory drilled weep holes for exit devices used in full exterior application, highly corrosive areas, and where noted in hardware sets.
13. Provide exit devices with optional trim designs to match other lever and pull designs used on the project.
2.10 CYLINDERS
A. Manufacturers and Products:
1. Scheduled Manufacturer:
a. Falcon
2. Acceptable Manufacturers and Products:
a. Best
b. Sargent
B. Requirements:
1. Provide cylinders/cores compliant with ANSI/BHMA A156.5; latest revision; cylinder face finished to match lockset; manufacturer’s series as indicated. Refer to “KEYING” article, herein.
087100 - 11
2. Provide cylinders in the below-listed configuration(s), distributed throughout the Project as indicated.
a. Open: cylinder with small format interchangeable core (SFIC) core with open keyway
2.11 KEYING
A. Scheduled System:
1. New factory registered system:
a. Provide a factory registered keying system, complying with guidelines in ANSI/BHMA A156.28, incorporating decisions made at keying conference.
B. Requirements:
1. Construction Keying:
a. Temporary Construction Cylinder Keying.
1) Provide construction cores that permit voiding construction keys without cylinder removal, furnished in accordance with the following requirements.
a) Split Key or Lost Ball Construction Keying System.
b) 3 construction control keys, and extractor tools or keys as required to void construction keying.
c) 12 construction change (day) keys.
2) Owner or Owner’s Representative will void operation of temporary construction keys.
b. Replaceable Construction Cores.
1) Provide temporary construction cores replaceable by permanent cores, furnished in accordance with the following requirements.
a) 3 construction control keys
b) 12 construction change (day) keys.
2) Owner or Owner’s Representative will replace temporary construction cores with permanent cores.
2. Permanent Keying:
a. Provide permanent cylinders/cores keyed by the manufacturer according to the following key system.
1) Master Keying system as directed by the Owner.
b. Forward bitting list and keys separately from cylinders, by means as directed by Owner.
Failure to comply with forwarding requirements will be cause for replacement of cylinders/cores involved at no additional cost to Owner.
c. Provide keys with the following features:
1) Material: Nickel silver; minimum thickness of .107-inch (2.3mm)
2) Patent Protection: Keys and blanks protected by one or more utility patent(s).
3) Geographically Exclusive: Where High Security or Security cylinders/cores are indicated, provide nationwide, geographically exclusive key system complying with the following restrictions.
d. Identification:
1) Mark permanent cylinders/cores and keys with applicable blind code for identification. Do not provide blind code marks with actual key cuts.
2) Identification stamping provisions must be approved by the Architect and Owner.
087100 - 12
3) Stamp cylinders/cores and keys with Owner’s unique key system facility code as established by the manufacturer; key symbol and embossed or stamped with “DO NOT DUPLICATE” along with the “PATENTED” or patent number to enforce the patent protection.
4) Failure to comply with stamping requirements will be cause for replacement of keys involved at no additional cost to Owner.
5) Forward permanent cylinders/cores to Owner, separately from keys, by means as directed by Owner.
e. Quantity: Furnish in the following quantities.
1) Permanent Control Keys: 3.
2) Master Keys: 6.
3) Change (Day) Keys: 3 per cylinder/core that is keyed differently
4) Key Blanks: Quantity as determined in the keying meeting.
2.12 DOOR CLOSERS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Falcon SC70A series
2. Acceptable Manufacturers and Products:
a. LCN 4050 series
b. Norton 7500 series
c. Sargent 351 series
B. Requirements:
1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. ISO 9000 certify closers. Stamp units with date of manufacture code.
2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder.
3. Closer Body: 1-1/2-inch (38 mm) diameter with 5/8-inch (16 mm) diameter heat-treated pinion journal.
4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.
5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards.
6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck.
7. Pressure Relief Valve (PRV) Technology: Not permitted.
8. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.
2.13 DOOR CLOSERS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
087100 - 13
a. Falcon SC80A series
2. Acceptable Manufacturers and Products:
a. LCN 1450 series
b. Norton 8000 series
c. Sargent 1331 series
B. Requirements:
1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory.
2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder.
3. Closer Body: 1-1/4-inch (32 mm) diameter, with 5/8-inch (16 mm) diameter heat-treated pinion journal.
4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.
5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards.
6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck.
7. Pressure Relief Valve (PRV) Technology: Not permitted.
8. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.
2.14 DOOR CLOSERS
A. Manufacturers and Products:
1. Scheduled Manufacturer and Product:
a. Falcon SC60A series
2. Acceptable Manufacturers and Products:
a. LCN 1250 series
b. Norton 1600 series
c. Sargent 1131 series
B. Requirements:
1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory.
2. Provide door closers with fully hydraulic, full rack and pinion action with aluminum cylinder.
3. Closer Body: 1-3/8-inch (35 mm) diameter with 5/8-inch (16 mm) diameter pinion journal.
4. Hydraulic Fluid: Fireproof, passing requirements of UL10C.
5. Pressure Relief Valve (PRV) Technology: Not permitted.
6. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.
2.15 DOOR TRIM
087100 - 14
A. Manufacturers:
1. Scheduled Manufacturer:
a. Ives
2. Acceptable Manufacturers:
a. Burns
b. Trimco
c. Rockwood
B. Requirements:
1. Provide push plates, push bars, pull plates, pulls, and hands-free reversible door pulls with diameter and length as scheduled.
2.16 PROTECTION PLATES
A. Manufacturers:
1. Scheduled Manufacturer:
a. Ives
2. Acceptable Manufacturers:
a. Burns
b. Trimco
c. Rockwood
B. Requirements:
1. Provide protection plates with a minimum of 0.050 inch (1 mm) thick, beveled four edges as scheduled. Furnish with sheet metal or wood screws, finished to match plates.
2. Sizes plates 2 inches (51 mm) less width of door on single doors, pairs of doors with a mullion, and doors with edge guards. Size plates 1 inch (25 mm) less width of door on pairs without a mullion or edge guards.
3. At fire rated doors, provide protection plates over 16 inches high with UL label.
2.17 OVERHEAD STOPS AND OVERHEAD STOP/HOLDERS
A. Manufacturers:
1. Scheduled Manufacturers:
a. Glynn-Johnson
2. Acceptable Manufacturers:
a. Rixson
b. ABH
B. Requirements:
087100 - 15
1. Provide overhead stop at any door where conditions do not allow for a wall stop or floor stop presents tripping hazard.
2.18 DOOR STOPS AND HOLDERS
A. Manufacturers:
1. Scheduled Manufacturer:
a. Ives
2. Acceptable Manufacturers:
a. Burns
b. Trimco
c. Rockwood
B. Provide door stops at each door leaf:
1. Provide wall stops wherever possible. Provide concave type where lockset has a push button of thumbturn.
2. Where a wall stop cannot be used, provide universal floor stops.
3. Where wall or floor stop cannot be used, provide overhead stop.
4. Provide roller bumper where doors open into each other and overhead stop cannot be used.
2.19 THRESHOLDS, SEALS, DOOR SWEEPS, AUTOMATIC DOOR BOTTOMS, AND GASKETING
A. Manufacturers:
1. Scheduled Manufacturer:
a. Zero International
2. Acceptable Manufacturers:
a. National Guard
b. Reese
c. Pemko
B. Requirements:
1. Provide thresholds, weather-stripping, and gasketing systems as specified and per architectural details. Match finish of other items.
2. Smoke- and Draft-Control Door Assemblies: Where smoke- and draft-control door assemblies are required, provide door hardware that meets requirements of assemblies tested according to UL 1784 and installed in compliance with NFPA 105.
3. Provide door sweeps, seals, astragals, and auto door bottoms only of type where resilient or flexible seal strip is easily replaceable and readily available.
4. Size thresholds 1/2 inch (13 mm) high by 5 inches (127 mm) wide by door width unless otherwise specified in the hardware sets or detailed in the drawings.
2.20 SLIDING DOOR HARDWARE
087100 - 16
A. Manufacturer:
1. Scheduled Manufacturer:
a. Johnson Hardware
2. Acceptable Manufacturers:
a. KN Crowder
b. Hafele
B. Requirements:
1. Provide complete sets of door hardware as recommended by manufacturer for door type and weight.
a. Include track, hangers, fasteners, guides, and other hardware as required for complete installation.
2.21 FINISHES
A. FINISH: BHMA 622/631 (US19); EXCEPT:
1. Door Closers: Powder Coat to Match
2. Weatherstripping: Black
3. Thresholds: Mill Finish Black
PART 3 - EXECUTION
3.01 EXAMINATION
A. Prior to installation of hardware, examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance. Verify doors, frames, and walls have been properly reinforced for hardware installation.
B. Submit a list of deficiencies in writing and proceed with installation only after unsatisfactory conditions have been corrected.
3.02 INSTALLATION
A. Mount door hardware units at heights to comply with the following, unless otherwise indicated or required to comply with governing regulations.
1. Standard Steel Doors and Frames: ANSI/SDI A250.8.
2. Custom Steel Doors and Frames: HMMA 831.
3. Interior Architectural Wood Flush Doors: ANSI/WDMA I.S. 1A
4. Installation Guide for Doors and Hardware: DHI TDH-007-20
087100 - 17
B. Install door hardware in accordance with NFPA 80, NFPA 101 and provide post-install inspection, testing as specified in section 1.03.E unless otherwise required to comply with governing regulations.
C. Install each hardware item in compliance with manufacturer's instructions and recommendations, using only fasteners provided by manufacturer.
D. Do not install surface mounted items until finishes have been completed on substrate. Protect all installed hardware during painting.
E. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate as necessary for proper installation and operation.
F. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.
G. Install operating parts so they move freely and smoothly without binding, sticking, or excessive clearance.
H. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than quantity recommended by manufacturer for application indicated.
I. Lock Cylinders:
1. Install construction cores to secure building and areas during construction period.
2. Replace construction cores with permanent cores as indicated in keying section.
3. Furnish permanent cores to Owner for installation.
J. Continuous Hinges: Re-locate the door and frame fire rating labels where they will remain visible so that the hinge does not cover the label once installed.
K. Door Closers & Auto Operators: Mount closers/operators on room side of corridor doors, inside of exterior doors, and stair side of stairway doors from corridors. Mount closers/operators so they are not visible in corridors, lobbies and other public spaces unless approved by Architect.
L. Overhead Stops/Holders: Mount overhead stops/holders on room side of corridor doors, inside of exterior doors, and stair side of stairway doors.
M. Thresholds: Set thresholds in full bed of sealant complying with requirements specified in Division 07 Section ''Joint Sealants.''
N. Stops: Provide floor stops for doors unless wall or other type stops are indicated in door hardware schedule. Do not mount floor stops where they may impede traffic or present tripping hazard.
O. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.
P. Door Bottoms and Sweeps: Apply to bottom of door, forming seal with threshold when door is closed.
3.03 ADJUSTING
087100 - 18
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended.
Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
1. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.
B. Occupancy Adjustment: Approximately three to six months after date of Substantial Completion, examine and readjust each item of door hardware, including adjusting operating forces, as necessary to ensure function of doors and door hardware.
3.04 CLEANING AND PROTECTION
A. Clean adjacent surfaces soiled by door hardware installation.
B. Clean operating items per manufacturer's instructions to restore proper function and finish.
C. Provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of Substantial Completion.
3.05 DOOR HARDWARE SCHEDULE
A. The intent of the hardware specification is to specify the hardware for interior and exterior doors, and to establish a type, continuity, and standard of quality. However, it is the door hardware supplier's responsibility to thoroughly review existing conditions, schedules, specifications, drawings, and other Contract Documents to verify the suitability of the hardware specified.
B. Discrepancies, conflicting hardware, and missing items are to be brought to the attention of the architect with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application.
C. Hardware items are referenced in the following hardware schedule. Refer to the above specifications for special features, options, cylinders/keying, and other requirements.
D. Hardware Sets:
Hardware Group No. 01
For use on Door #(s):
101 102A
Provide each RU door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
DOOR/HARDWARE BY OVERHEAD DOOR
MANUFACTURER
087100 - 19
Hardware Group No. 02
For use on Door #(s):
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
BALANCE OF EXISTING
HARDWARE
TO REMAIN
1 EA STOREROOM LOCK T581BDC LAT 622 FAL
1 EA SFIC CORE C607 622 FAL
1 EA DEADBOLT FILLER PLATE BF135/BF161 BLK DON
GENERAL CONTRACTOR AND HARDWARE SUPPLIER TO FIELD VERIFY EXISTING CONDITIONS TO
ENSURE THE COMPATIBILITY OF NEW HARDWARE WITH EXISTING PREPS PRIOR TO ORDER OF NEW
MATERIALS
Hardware Group No. 03
100 109
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
1 EA CONT. HINGE 112HD 693 IVE
1 EA PANIC HARDWARE 25-R-NL-OP 622 FAL
1 EA RIM HOUSING C953 622 FAL
1 EA SFIC CORE C607 622 FAL
1 EA SFIC CONST. CORE 1408BDC FAL
1 EA 90 DEG OFFSET PULL 8190EZHD 12" O BLK IVE
1 EA SURFACE CLOSER SC71A SS 622 FAL
1 EA MOUNTING PLATE SC70A-XX (AS REQ'D) 622 FAL
1 EA GASKETING/SEALS BY DOOR/FRAME
MANUFACTURER
B/O
1 EA DOOR SWEEP 39BK BK ZER
1 EA THRESHOLD 654A-223 A ZER
087100 - 20
Hardware Group No. 04
For use on Door #(s):
102B
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
1 EA CONT. HINGE 112HD 693 IVE
1 EA PANIC HARDWARE 25-R-NL-OP 622 FAL
1 EA RIM HOUSING C953 622 FAL
1 EA SFIC CORE C607 622 FAL
1 EA SFIC CONST. CORE 1408BDC FAL
1 EA 90 DEG OFFSET PULL 8190EZHD 12" O BLK IVE
1 EA SURFACE CLOSER SC71A FA 622 FAL
1 EA MOUNTING PLATE SC70A-XX (AS REQ'D) 622 FAL
1 EA WALL STOP WS406/407CCV BLK IVE
1 EA GASKETING/SEALS BY DOOR/FRAME
MANUFACTURER
B/O
1 EA DOOR SWEEP 39BK BK ZER
Hardware Group No. 05
107 108
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA HINGE 5BB1 4.5 X 4.5 FBLK/6
IVE
1 EA PUSH PLATE 8200 6" X 16" BLK IVE
1 EA PULL PLATE 8302 10" 4" X 16" BLK IVE
1 EA SURFACE CLOSER SC81A RW/PA FC (PULL SIDE
MOUNT)
622 FAL
1 EA KICK PLATE 8400 10" X 2" LDW B-CS BLK IVE
1 EA WALL STOP WS406/407CCV BLK IVE
087100 - 21
Hardware Group No. 06
For use on Door #(s):
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA HINGE 5BB1 4.5 X 4.5 FBLK/6
IVE
1 EA STOREROOM LOCK W581BDC LAT 622 FAL
1 EA SFIC CORE C607 622 FAL
1 EA SURFACE CLOSER SC81A RW/PA FC (PULL SIDE
MOUNT)
622 FAL
1 EA KICK PLATE 8400 10" X 2" LDW B-CS BLK IVE
1 EA WALL STOP WS406/407CCV BLK IVE
1 EA GASKETING 488SBK PSA BK ZER
Hardware Group No. 07
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA HINGE 5BB1 4.5 X 4.5 NRP FBLK/6
IVE
1 EA PRIVACY LOCK W301S LAT 622 FAL
1 EA SURFACE CLOSER SC81A SS FC 622 FAL
Hardware Group No. 08
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA PREHUNG HINGES BY DOOR/FRAME
MANUFACTURER
B/O
1 EA STOREROOM LOCK W581BDC LAT 622 FAL
1 EA SFIC CORE C607 622 FAL
1 EA SURFACE CLOSER SC81A SS FC 622 FAL
087100 - 22
Hardware Group No. U1
For use on Door #(s):
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA PREHUNG HINGES BY DOOR/FRAME
MANUFACTURER
B/O
1 EA PASSAGE SET F10 LAT 622 SCH
1 EA OH STOP 450S 622 GLY
Hardware Group No. U2
Provide each SGL door(s) with the following:
QTY DESCRIPTION CATALOG NUMBER FINISH MFR
3 EA PREHUNG HINGES BY DOOR/FRAME
MANUFACTURER
B/O
1 EA PASSAGE SET F10 LAT 622 SCH
1 EA DOOR BOLT W/ TRIM IS B581 622 SCH
1 EA OH STOP 450S 622 GLY
1 EA…