Questions – RFQ IHS1426354
1) Is there enough space in the current rack system for the equipment to be installed? That equipment would need to be rack mounted and I was wondering how much space was available in the current rack cabinet? Cameras are installed in different ZONES and there is enough space in each closet. The pharmacy department cameras will need extra cisco switch with 10‐ Gig LC/LC fiber SFP.
2) Is there a part# for the video intercom to be installed? Also, is there a particular workstation preferred? Dell, IBM...ect Dell Computers are required.
3) Does this system need to be added to the current UPS? If so, can the current UPS handle an additional 47 cameras, 1 server and (2) PoE switches? Yes current UPS can handle more equipment.
4) Are we to provide the ethernet switch or switches that will be needed to network the CCTV system? If so, is there a specific brand or model we need to provide? 3 extra switches will need to be provided by contractor. CISCO catalyst 9300 48 port UPOE with 10g fiber LC/LC uplinks SFP 10‐g for switch and for Core switch.
5) What FPS (frames per second) do you want set for recording? This will determine the size of storage required for 30 days of storage requested. The more FPS, the more storage required for 30 days retention. 30FPS
6) Are there 2 video intercom systems to be installed? If the Requested Door locations are not where the video intercom is to be installed, can you show the location(s) 1‐system
7) Is the pharmacy in the same building as the Medstations? If so, can you show where it is on drawing 2? Yes in the same building on bottom of page next to the octagon entrance.
8) Where is the room that will house the NVR and cabling patch panel? It will be in the main data center.
9) Performance Standards, Section 1.3 states “System shall include NVR allowing for recoding capability up to 30 days of storage.”
‐ Will each system (Pharmacy and CCHCF) require a separate NVR? It can but expansion of current system would be better.
10) Performance Standards, Section 1.3 states “The Contractor shall provide all network infrastructure to ensure the entire system is operable. This includes providing cable and pulling and installing cabling. Cables shall be in cable trays when installed in the ceiling space.”
‐ Do the existing facilities have existing cable trays installed above the ceiling? Not all areas, some will need J‐Hooks.
‐ Is it assumed we would be utilizing existing or providing new cable trays? Utilize existing where trays are used, the use of J‐Hooks to red iron will be the other option.
11) Special Requirements for Completion, states “This system shall be an expansion of the WiseNet
WAVE system currently in place at CCHCF, Chinle AZ”
‐ How old is this system? 3years old ‐ Is this existing system in a rack or cabinet? Rack mounted in telecom 4 post rack with round screw holes.
‐ Will the existing CCHCF NVR have space for the additional 21 Cameras? No It will need to be expanded.
12) Special Requirements for Completion, states “The Pharmacy security cameras shall be added to the present WiseNet WAVE system for monitor for security operations.”
‐ How old is this system? 3years old ‐ Is this existing system in a rack or cabinet? Rack mounted in telecom 4 post rack with round screw holes.
‐ Will the existing Pharmacy NVR have space for the additional 23 Cameras? No It will need to be expanded.