Drawing.pdf
PDF 13 MB Posted
- Attached to
- Construct Medical Reference Laboratory
- Solicitation number
- IFBP04141600001
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_003.pdf | ||
| meeting_minutes.pdf | ||
| Amend_2.pdf | ||
| 0001_2-4.pdf | ||
| Spec_1.pdf | ||
| wage_determination.pdf | ||
| Missouri_Limited_Exemption.pdf | ||
| Bid_bond.pdf | ||
| Spec_2.pdf | ||
| Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
U.S. Department of Justice Federal Bureau of Prisons
U.S. Medical Center for Federal Prisoners 1900 West Sunshine
Springfield, MO 65807
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
SHEET NAME
SHEET NUMBER
PROPERTY OF THE UNITED STATES GOVERNMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS,
SPECIFICATIONS, OR INFORMATION TO UNAUTHORIZED PERSONS IS PROHIBITED.
Do not remove this notice
Properly destroy documents / media when no longer needed.
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
SPG PROJECT
/3
0/
0:
:4
AM
G000
Medical Reference Lab
4B2J
1900 West Sunshine
COVER SHEET
11/25/2015 Final Construction Documents
Springfield, Missouri, 65807
Medical Reference Laboratory
1900 West Sunshine Springfield Missouri, 65807
SITE ORIENTATION MAP
N.T.S.
NN
MEDICAL REFERENCE LABORATORY
FEDERAL BUREAU OF PRISONS
NEW FACILITY
1 NORTH - EXTERIOR VIEW
W. SUNSHINE ST.
S.
S
C
EN
IC
A
VE
PROJECT SITE
MARK DATE DESCRIPTION
DRAWING INDEX
Sheet
Number Sheet Name
GENERAL
G000 COVER SHEET
G001 CODE PLAN
CIVIL
C100 GENERAL NOTES
C200 SURVEY
C300 SITE DEMOLITION & EROSION CONTROL
C400 SITE PLAN
C500 GRADING
C600 UTILITIY PLAN
C700 DETAILS
STRUCTURAL
S000 GENERAL NOTES
S100 FOUNDATION PLAN
S200 FOUNDATION DETAILS
S300 ROOF FRAMING PLAN
S400 FRAMING DETAILS
ARCHITECTURAL
A101 FLOOR PLAN
A102 CLERESTORY PLAN
A103 ROOF PLAN
A104 REFLECTED CEILING PLAN
A201 EXTERIOR ELEVATIONS
A202 EXTERIOR ELEVATIONS
A210 INTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A302 BUILDING SECTIONS
A310 WALL SECTIONS / DETAILS
A311 WALL SECTIONS
A401 ACCESSORY SCHEDULE & RESTROOM LAYOUT
A411 ENLARGED FLOOR PLANS & MILLWORK DETAILS
A501 PARTITION TYPES & NOTES
A601 DOOR & HARDWARE SCHEDULE
A611 FINISH PLAN & LEGEND
A612 EQUIPMENT PLACEMENT PLAN
A913 PARTITION DETAILS
A914 PARTITION DETAILS
FIRE PROTECTION
FA001 GENERAL NOTES & DETAILS
FA101 FIRE ALARM FLOOR PLAN
FS001 FIRE SPRINKLER GENERAL NOTES AND DETAILS
FS101 FIRE SPRINKLER FLOOR PLAN
PLUMBING
P000 PLUMBING SYMBOLS AND LEGENDS
P100 PLUMBING WATER AND GAS PLAN
P101 PLUMBING WASTE AND VENT PLAN
P200 PLUMBING DETAILS
P201 PLUMBING DETAILS
P300 PLUMBING SCHEDULES
MECHANICAL
M000 MECHANICAL SYMBOLS AND LEGENDS
M100 MECHANICAL HVAC FLOOR PLAN
M101 MECHANICAL PIPING PLAN
M300 MECHANICAL DETAILS
M301 MECHANICAL DETAILS
M302 MECHANICAL SECTIONS
M400 MECHANICAL SCHEDULES
M401 MECHANICAL SCHEDULES
M500 MECHANICAL CONTROL DIAGRAMS AND SEQUENCES
M501 MECHANICAL CONTROL DIAGRAMS AND SEQUENCES
M502 MECHANICAL CONTROL DIAGRAMS AND SEQUENCES
M503 MECHANICAL CONTROL DIAGRAMS AND SEQUENCES
ELECTRICAL
E000
ES100
EL100
EP100
E300 E400 E501
ELECTRICAL LEGEND AND GENERAL NOTES
ELECTRICAL SITE PLAN
LIGHTING PLAN
POWER PLAN
ELECTRICAL DETAILS
ELECTRICAL ONE-LINE DIAGRAM
ELECTRICAL SCHEDULES
DRAWING INDEX
Sheet
Number Sheet Name
REF.
1 2 3
A
B
C
TRAINING
ROOM
MOLECULAR
LAB
MICROBIOLOGY
LAB
GENERAL
LAB
HALLWAY
MEN'S
RESTROOM
WOMEN'S
RESTROOM
ENTRANCE
HALL
VESTIBULE
MRL
RECEPTION
MRL MGR
OFFICE
STORAGE
DATA &
PHONE
LAB
OFFICE
LAB
OFFICE
JANITOR
RECEIVING
MECH
ROOM
LAB
WORKROOM
PRIMARY BUILDING EGRESS
EGRESS WIDTH = 34"
MAXIMUM ALLOWABLE COMMON PATH OF TRAVEL = 100'
MAXIMUM ALLOWABLE EXIT ACCESS TRAVEL DISTANCE = 300'
ACTUAL EXIT ACCESS TRAVEL DISTANCE = 97'
EGRESS WIDTH = 68.5"
MAXIMUM ALLOWABLE COMMON PATH OF TRAVEL = 100'
MAXIMUM ALLOWABLE EXIT ACCESS TRAVEL DISTANCE = 300'
ACTUAL EXIT ACCESS TRAVEL DISTANCE = 119'
EGRESS WIDTH = 72"
EGRESS WIDTH = 72"
MAXIMUM ALLOWABLE COMMON PATH OF TRAVEL = 100'
MAXIMUM ALLOWABLE EXIT ACCESS TRAVEL DISTANCE = 300'
ACTUAL EXIT ACCESS TRAVEL DISTANCE = 108'
101A
101B
116A
113 114
111110
116B
115B 115A
C.P.O.T = 58'-10"
C.P.O.T = 45'-3"
MAX. TRAVEL DISTANCE = 119'118
106105
SEMI RECESSED FIRE
EXTINGUISHER
SURFACE MOUNTED FIRE
EXTINGUISHER CABINET
SURFACE MOUNTED FIRE
EXTINGUISHER CABINET
FIRE EXTINGUISHER
CODE SUMMARY:
BUILDING: 2012 INTERNATIONAL BUILDING CODE
MECHANICAL: 2012 INTERNATIONAL MECHANICAL CODE
PLUMBING: 2012 NATIONAL PLUMBING CODE
ELECTRICAL: 2010 NATIONAL ELECTRICAL CODE
FIRE/LIFE SAFETY: 2010 NATIONAL FIRE PROTECTION ASSOCIATION
ENERGY: 2012 IECC
ACCESSIBILITY: ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
(ABAAS) CURRENT EDITION
CODE ANALYSIS: USE / OCCUPANCY
OCCUPANCY GROUP: B
CONSTRUCTION TYPE: 5B (FULLY SPRINKLERED)
ALLOWABLE AREA: 2 STORY / 9,000 GSF (UNSPRINKLERED)
300% INCREASE FOR FULLY SPRINKLERED = 27,000GSF
ACTUAL BUILDING AREA: 1 STORY / 6,745 GSF
PER IBC TABLE2902.1
BUSINESS AREA: 6,204 GSF
@ 100 GSF / OCCUPANT = 63 OCCUPANTS
ACCESSORY USE AREA:541 GSF
@ 300 GSF / OCCUPANT = 2 OCCUPANTS
TOTAL OCCUPANCY = 65 OCCUPANTS
CODE ANALYSIS: FIXTURE COUNT IBC 2902.1
TOILETS: 1PER 25 OCCUPANTS FOR THE FIRST 50 OCCUPANTS = 2
1 PER 50 FOR REMAINDER EXCEEDING 50 = 1
TOTAL REQUIRED = 3
PROVIDED = 4
LAVATORIES: 1 PER 40 OCCUPANTS FOR THE FIRST 80 OCCUPANTS = 2 REQUIRED
PROVIDED = 4
DRINKING FOUNTAIN: 1 PER 100 OCCUPANTS REQUIRED = 1 REQUIRED
PROVIDED = 2
SERVICE SINK: 1 REQUIRED, 1 PROVIDED
TOILET FIXTURES DIVIDED EVENLY BETWEEN MEN'S AND WOMEN'S RESTROOMS
UP TO 50 PERCENT OF THE MEN'S TOILET FIXTURES CAN BE URINALS, 1 PROVIDED
CODE ANALYSIS: EGRESS
COMMON PATH OF TRAVEL PER IBC TABLE 1014.3 =100' MAXIMUM.
EXIT ACCESS TRAVEL DISTANCE PER IBC TABLE 1016.2 = 300' MAXIMUM
CORRIDOR WIDTH PER IBC TABLE 1018.2 = 44" MINIMUM
MINIMUM EGRESS WIDTH PER IBC 1005.3.2:
OCCUPANT LOAD x 0.2" = 13" MINIMUM
ACTUAL EGRESS WIDTH = 174.5" (SEE CODE PLAN)
REQUIRED EXITS = 2
ACTUAL PROVIDED = 3
RE
VI
SI
ON
B
LO
CK
CO
NT
RA
CT
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
ST
AM
P
OR
S
EA
L
OW
NE
R
ID
EN
TIF
IC
AT
IO
N
BU
ILD
IN
G
PR
OJ
EC
T
SH
EE
T
U.S. Department of Justice Federal Bureau of Prisons
U.S. Medical Center for Federal Prisoners 1900 West Sunshine
Springfield, MO 65807
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
PROPERTY OF THE UNITED STATES GOVERNMENT
SENSITIVE BUT UNCLASSIFIED
Properly destroy documents / media when no longer needed.
DE
SI
GN
ER
ID
EN
TIF
IC
AT
IO
N
SPG PROJECT
/3
0/
0:
:4
AM
G001
Medical Reference Lab
4B2J
1900 West Sunshine
CODE PLAN
11/25/2015 Final Construction Documents
Springfield, Missouri, 65807
Medical Reference Laboratory
1/4" = 1'-0"1 CODE PLAN
1/4" = 1'-0"
CODE SUMMARY
MARK DATE DESCRIPTION
11/24/2015
R
E
V
I
S
I
O
N
B
L
O
C
K
C
O
N
T
R
A
C
T
D
E
S
I
G
N
I
D
E
N
T
I
F
I
C
A
T
I
O
N
S
T
A
M
P
S
A
L
O
W
N
E
N
T
I
F
I
C
A
T
I
O
N
B
U
I
L
D
I
N
G
P
R
O
J
E
C
T
S
H
E
E
T
U.S. Department of Justice Federal Bureau of Prisons
U.S. Medical Center for Federal Prisoners 1900 West Sunshine
Springfield, MO 65807
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
S E
N S
IT
IV
E B
U T
U N
C L
A S
S
IF
IE
D
P ro p e rl y d e s tr o y d o c u m e n ts m e d ia w h e n n o l o n g e r n e e d e d
D
E
S
I
G
N
E
N
T
I
F
I
C
A
T
I
O
N
Medical Reference Laboratory
Springfield, Missouri, 65807
Final Construction Documents
11/25/2015
Wallace Engineering - Structural Consultants, Inc.
Professional Engineering Corporation Missouri Certificate of Aurthorization #001268
SPG PROJECT 4B2J
/2
/2
:3 :2
P
M
S000
Construct Medical Reference Lab
JJM
DLS
1900 West Sunshine
GENERAL NOTES
DESIGN PARAMETERS
1. BUILDING CODE IBC 2012
RISK CATEGORY II
2. LIVE LOADS
A. ROOF 20 PSF
3. ROOF SNOW LOAD
A. GROUND SNOW LOAD, Pg 20 PSF
B. FLAT ROOF SNOW LOAD, Pf 20 PSF
C. SNOW EXPOSURE FACTOR, Ce 1.0
D. SNOW LOAD IMPORTANCE FACTOR, I 1.0
E. THERMAL FACTOR, Ct 1.0
4. WIND DESIGN DATA
A. BASIC WIND SPEED (3 SECOND GUST), Vult 115 MPH
B. WIND EXPOSURE CATEGORY C
C. INTERNAL PRESSURE COEFFICIENT, GCpi +/- 0.18
D. DESIGN WIND PRESSURE ON COMPONENTS AND CLADDING (ASD)
1.) WALLS (200 SQUARE FEET EFFECTIVE WIND AREA)
END ZONES 15.1 PSF
INTERIOR ZONES 14.1 PSF
2.) PARAPETS (50 SQUARE FEET EFFECTIVE WIND AREA)
END ZONES 32.6 PSF
INTERIOR ZONES 32.6 PSF
3.) ROOF, ASD (NET UPLIFT)
CORNER ZONES 14.0 PSF
END ZONES 14.0 PSF
INTERIOR ZONES 11.1 PSF
E. WIDTH OF END ZONE 4.5 FT
5. EARTHQUAKE DESIGN DATA
A. SEISMIC IMPORTANCE FACTOR, Ie 1.0
B. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETER, Ss 0.193
C. MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETER, S1 0.103
D. SITE CLASS C
E. DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETER, Sds 0.154
F. DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETER, Sd1 0.117
G. SEISMIC DESIGN CATEGORY B
H. STRUCTURAL SYSTEM
1.) BASIC SEISMIC FORCE-RESISTING SYSTEM TYPE BEARING WALL SYSTEM
2.) VERTICAL ELEMENT TYPE INTERMEDIATE REINFORCED
MASONRY SHEAR WALLS
3.) DESIGN BASE SHEAR, ASD 0.027 W
4.) RESPONSE MODIFICATION FACTOR, R 4
J. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
GENERAL NOTES
MASONRY
1. CONCRETE MASONRY UNITS SHALL MEET ASTM SPECIFICATION C90, GRADE N TYPE I BLOCK WITH A MINIMUM UNIT COMPRESSIVE STRENGTH = 2800 PSI. THE SPECIFIED DESIGN COMPRESSIVE STRENGTH OF THE CONCRETE MASONRY ASSEMBLY (f'm) SHALL BE 2000 PSI.
2. MORTAR SHALL MEET ASTM SPECIFICATION C270 FOR TYPE "S" MORTAR.
3. GROUT SHALL MEET ASTM SPECIFICTION C476 AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH
OF 2000 PSI.
4. GROUT PLACED BY THE LOW LIFT GROUTING METHOD SHALL BE MECHANICALLY CONSOLIDATED USING A VIBRATOR WITH A MAXIMUM 3/4 INCH DIAMETER HEAD. REFERENCE THE CONCRETE UNIT MASONRY
SPECIFICATION FOR HIGH LIFT GROUTING PROCEDURES.
5. HORIZONTAL JOINT REINFORCEMENT SHALL BE LADDER TYPE (REFERENCE THE CONCRETE UNIT MASONRY SPECIFICATION). JOINT REINFORCEMENT SHALL BE SPACED AT 8 INCHES ON CENTER BELOW
FINISHED FLOOR AND IN PARAPETS, AND 16 INCHES ON CENTER ABOVE FINISHED FLOOR.
6. CONCRETE MASONRY SHALL BE LAID IN RUNNING BOND.
7. CONCRETE MASONRY BELOW FINISHED FLOOR SHALL BE NORMAL WEIGHT UNITS AND SHALL HAVE ALL THE CELLS FULLY GROUTED. CONCRETE MASONRY ABOVE FINISHED FLOOR SHALL BE MEDIUM WEIGHT OR LIGHT WEIGHT AND IS TO BE GROUTED ONLY AT REINFORCED CELLS AND BOND BEAMS. ALL CELLS
WITH REINFORCING SHALL BE GROUTED SOLID.
8. REFER TO WALL SECTIONS AND DETAILS FOR MISCELLANEOUS BOND BEAM LOCATIONS AND EMBEDDED ITEMS. USE OPEN KNOCK OUT BOND BEAM BLOCK. DO NOT USE TROUGH TYPE BLOCKS FOR BOND
BEAMS. DO NOT CONTINUE BOND BEAM REINFORCING THROUGH CONTROL JOINTS.
9. REINFORCING STEEL SHALL MEET ASTM SPECIFICATION A615, GRADE 60.
10. ANCHORS INSTALLED IN GROUT FILLED CONCRETE MASONRY UNITS SHALL ONLY BE USED WHERE SPECIFIED IN THE CONTRACT DOCUMENTS . ANCHORS MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. USE HILTI HIT-HY 150 MAX ADHESIVE ANCHORING SYSTEM (OR HILTI HIT ICE ADHESIVE ANCHORING SYSTEM OR HILTI KWIK BOLT 3 EXPANSION ANCHOR). REFERENCE CONTRACT DOCUMENTS FOR ANCHOR SIZE AND EMBEDMENT. SUBSTITUTIONS TO
THE SPECIFIED ANCHORS MUST BE APPROVED BY THE ENGINEER-OF-RECORD.
11. CONSTRUCTION BRACING FOR MASONRY WALLS SHALL BE DESIGNED AND DETAILED BY A
PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED. MASONRY SUBMITTALS SHALL CONTAIN A LETTER, SEALED BY THE PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION, STATING DESIGN LOADS AND CRITERIA WHICH WERE USED IN BRACING DESIGN.
THE BRACING DESIGN DRAWINGS SHALL BE SIGNED AND SEALED BY THE PROFESSIONAL ENGINEER
RESPONSIBLE FOR THEIR PREPARATION AND SHALL BE ISSUED TO THE AUTHORITY HAVING
JURISDICTION AFTER SUBMITTAL REVIEW AND PRIOR TO STARTING MASONRY CONSTRUCTION.
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL MEET THE FOLLOWING MINIMUM YIELD STRESS (Fy):
. YIELD ASTM SPECIFICATION
A. W, WT SHAPES: 50 KSI A992
B. BARS, PLATES, CHANNELS, ANGLES: 36 KSI A36
C. SQUARE, RECTANGULAR HSS: 46 KSI A500, GRADE B
D. ROUND HSS: 42 KSI A500, GRADE B
E. STRUCTURAL STEEL PIPE: 35 KSI A53, GRADE B
F. ANCHOR RODS: 36 KSI F1554
G. ALL-THREAD RODS: 36 KSI A36
H. HEADED STUD ANCHORS: 65 KSI TENSILE STRESS A108, GRADES 1010-1020
2. BOLTS FOR STEEL BEAM AND COLUMN CONNECTIONS SHALL BE 3/4-INCH DIAMETER ASTM A325-N
HIGH-STRENGTH BOLTS UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. ALL BOLTED
CONNECTIONS ARE BEARING TYPE UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. ALL BOLTS
SHALL BE TIGHTENED SNUG TIGHT UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS . FOR
PRETENSIONED OR SLIP-CRITICAL JOINTS, THE METHOD OF INSTALLATION SHALL BE TURN-OF-NUT WITH MATCH MARKING, TWIST-OFF-TYPE TENSION CONTROL BOLT ASSEMBLIES (ASTM F1852), OR DIRECT
TENSION INDICATORS (ASTM F959).
3. WELDING SHALL MEET ANSI / AWS D1.1, STRUCTURAL WELDING CODE LATEST REVISION. ELECTRODES
SHALL BE 70 KSI, LOW HYDROGEN.
4. PROVIDE DOUBLE NUTS AND DOUBLE WASHERS FOR STEEL COLUMN ANCHOR BOLTS TO ALLOW FOR ADJUSTMENT IN BASE PLATE ELEVATION. PROVIDE 1 1/2 INCH NON-SHRINK GROUT UNDER BASE PLATE AFTER ERECTION. USE 2 1/2 INCH NON-SHRINK GROUT WHEN COLUMN ANCHOR BOLTS ARE 1 1/4 INCH DIAMETER OR LARGER. NON-SHRINK GROUT SHALL BE NON-METALLIC WITH A MINIMUM COMPRESSIVE
STRENGTH OF 5,000 PSI AT 28 DAYS.
5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INCLUDING THE COSTS FOR ALL
MISCELLANEOUS STEEL SHOWN IN THE CONTRACT DOCUMENTS. THESE COSTS SHALL INCLUDE, BUT ARE NOT LIMITED TO, MISCELLANEOUS STEEL ITEMS SHOWN ON THE STRUCTURAL, ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.
6. PROVIDE GALVANIZED L7x4x1/2 (LLH) CONT FOR ALL BRICK LINTELS, UNO. EXTEND ANGLE 2'-0" BEYOND
EDGES OF OPENING TO BEAR ON BRICK
STEEL JOISTS
1. STEEL JOISTS SHALL BE AS INDICATED ON THE PLANS AND SHALL BE IN ACCORDANCE WITH THE
SPECIFICATIONS OF THE STEEL JOIST INSTITUTE (SJI) AND MEET THE FOLLOWING:
A. JOISTS SHALL BE DESIGNED FOR THE UNIFORM LOAD CAPACITY (AS SPECIFIED IN THE SJI STANDARD LOAD TABLES) IN ADDITION TO THE CONCENTRATED LOADS SHOWN IN THE CONTRACT DOCUMENTS.
B. JOISTS THAT SUPPORT CONCENTRATED LOADS SHALL HAVE THEIR CHORDS DESIGNED TO
WITHSTAND ALL BENDING STRESSES, OR THE LOADS SHALL OCCUR WITHIN 3 INCHES OF JOIST PANEL POINTS, OR THE JOIST SHALL BE REINFORCED PER THE "JOIST REINFORCING DETAIL" SHOWN HEREIN.
CONCENTRATED LOADS SHALL BE CENTERED ON JOISTS AND NOT ATTACHED TO THE EDGE OF CHORD
ANGLES.
C. JOISTS SHALL RESIST THE NET UPLIFT PRESSURE AS INDICATED ON THE "ROOF (NET UPLIFT)"
SECTION OF THE DESIGN PARAMETERS FOR "DESIGN WIND PRESSURE ON COMPONENTS AND
CLADDING". THIS PRESSURE SHALL ACT ALONE. AN ALLOWABLE STRESS INCREASE IS NOT PERMITTED.
D. FOR ALL MEMBERS THAT REQUIRE SPECIFIC ORIENTATION, PROVIDE TAG AT ONE END AND DEFINE
LOCATION OF TAGGED END ON ERECTION DRAWINGS.
E. JOIST MANUFACTURER SHALL DETERMINE THE SEAT DEPTH AND WIDTH OF BEARING AND
COORDINATE THE SAME WITH THE STEEL FABRICATOR. THE FOLLOWING SEAT DEPTHS ARE ASSUMED IN
THE CONTRACT DOCUMENTS: 2 1/2 INCH FOR K-SERIES JOISTS.
2. K-SERIES JOISTS SHALL BE WELDED TO SUPPORTING STEEL WITH MINIMUM 1/8 INCH FILLET WELDS 2 INCHES LONG EACH SIDE OR WITH TWO 1/2 INCH DIAMETER ASTM A307 BOLTS OR THE EQUIVALENT, UNLESS NOTED OTHERWISE IN CONTRACT DOCUMENTS. WHEN NEAR OR AT A COLUMN, BOLT JOIST TO
SUPPORTING STEEL IN CONFORMANCE WITH OSHA.
3. JOIST BRIDGING AND ERECTION STABILITY SHALL BE PROVIDED IN ACCORDANCE WITH THE OCCUPATIONAL SAFETY AND HAZARD ADMINISTRATION (OSHA) AND THE SPECIFICATIONS OF THE STEEL
JOIST INSTITUTE (SJI).
4. JOIST RTU LOADS ARE PROVIDED ON THE ROOF FRAMING PLAN, REFERENCE CONTRACT DOCUMENTS
FOR LOAD LOCATIONS, VALUES AND SUPPORT FRAMING.
5. JOIST MANUFACTURER SHALL DESIGN THE COMPRESSION CHORD OF ALL JOISTS SUPPORTING ROOF TOP UNITS, SKY LIGHTS, AND OTHER STRUCTURES FOR AN UNBRACED LENGTH APPLICABLE TO THE CONDITIONS AT THE PROJECT WHERE THE UNBRACED LENGTH IS GREATER THAN THE SJI MAXIMUM.
(REFERENCE ARCHITECTURAL AND MECHANICAL DRAWINGS)
6. DESIGN JOISTS FOR INTERNAL ROOF DRAINLINE LOCATIONS, IF REQUIRED. ADD 50 PLF FOR 8 INCH DIAMETER AND SMALLER, ADD 75 PLF FOR 10 INCH DIAMETER, ADD 102 PLF FOR 12 INCH DIAMETER, ADD 122 PLF FOR 14 INCH DIAMETER, ADD 200 PLF FOR 18 INCH DIAMETER. REFERENCE MECHANICAL AND
PLUMBING DRAWINGS FOR EXACT LOCATION.
7. JOIST DESIGNS SHALL BE PERFORMED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE WHERE
THE PROJECT IS LOCATED, EMPLOYED OR RETAINED BY THE JOIST MANUFACTURER.
8. SHOP DRAWING SHALL BE REVIEWED BY THE ARCHITECT AND THE ENGINEER-OF-RECORD PRIOR TO
JOIST FABRICATION.
STEEL DECK
1. ROOF DECK
A. ROOF DECK SHALL BE GALVANIZED TYPE "B". DEPTH SHALL BE AS SHOWN IN THE CONTRACT
DOCUMENTS.
B. ROOF DECK IS REQUIRED TO ACT AS A DIAPHRAGM. CONNECTIONS SHALL BE IN ACCORDANCE WITH STEEL DECK INSTITUTE SPECIFICATIONS. REFER TO THE ROOF DIAPHRAGM CONNECTION DIAGRAM FOR
ATTACHMENT.
C. DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF (2) SPANS UNLESS NOTED OTHERWISE IN THE
CONTRACT DOCUMENTS.
2. NON-COMPOSITE DECK
A. COMPOSITE ROOF DECK SHALL BE GALVANIZED NON-COMPOSITE STEEL DECK. DEPTH SHALL BE AS
SHOWN IN THE CONTRACT DOCUMENTS.
B REFER TO THE ROOF DIAPHRAGM CONNECTION DIAGRAM FOR ATTACHMENT.
C DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF (2) SPANS, UNLESS NOTED OTHERWISE IN
CONTRACT DOCUMENTS.
3. PROVIDE L5x3x1/4 (LLV) FIELD FABRICATED FRAME BETWEEN SUPPORTS AT ROOF OPENINGS LARGER
THAN 10", UNO
4. NO HANGING LOADS SHALL BE ATTACHED TO ROOF DECK.
GENERAL NOTES
GENERAL
1. STRUCTURAL ELEMENTS ARE NON-SELF SUPPORTING AND REQUIRE INTERACTION WITH OTHER ELEMENTS FOR STABILITY AND RESISTANCE TO LATERAL FORCES. FRAMING AND WALLS SHALL BE TEMPORARILY BRACED BY THE CONTRACTOR UNTIL PERMANENT BRACING, FLOOR AND ROOF DECKS, AND WALLS HAVE BEEN INSTALLED AND CONNECTIONS BETWEEN THESE ELEMENTS HAVE BEEN MADE.
2. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OF CONSTRUCTION, UNLESS NOTED OTHERWISE. THE CONTRACTOR IS SOLELY RESPONSIBLE
FOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES, AND OPERATION OF CONSTRUCTION AND
SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO.
3. THE SIZE AND LOCATION OF EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FOR
MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHALL BE VERIFIED BY THE CONTRACTOR.
PENETRATIONS SHALL BE SUBJECT TO APPROVAL BY THE ENGINEER-OF-RECORD. REFER TO
MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR OPENING LOCATIONS NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
4. USE ONLY DIMENSIONS INDICATED IN THE CONTRACT DOCUMENTS. DO NOT SCALE CONTRACT
DOCUMENTS OR USE ANY DIMENSIONS TAKEN FROM ELECTRONIC DRAWING FILES.
5. ASSUME EQUAL SPACING IF NOT INDICATED IN CONTRACT DOCUMENTS.
6. THE SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT DOCUMENTS AND SHALL BE USED IN CONJUCTION WITH THE CONTRACT DRAWINGS. WHERE REQUIREMENTS INDICATED ON THE CONTRACT
DRAWINGS DIFFER FROM THE SPECIFICATIONS, NOTIFY THE ARCHITECT AND THE
ENGINEER-OF-RECORD.
7. ARCHITECTURAL, MECHANICAL AND ELECTRICAL COMPONENTS AND SYSTEMS SHALL BE DESIGNED AND
CONSTRUCTED TO RESIST SEISMIC FORCES AS DETERMINED IN CHAPTER 13 OF ASCE 7.
8. DURING WELDING OR ANY OTHER CONSTRUCTION ACTIVITY THAT GENERATES SPARKS OR INTENSE
HEAT, THE CONTRACTOR SHALL PROVIDE ADEQUATE FIRE PROTECTION TO THE STRUCTURE AND
CONTENTS.
FOUNDATIONS
1. FOUNDATION DESIGNS, SUBGRADE PREPARATION NOTES, AND EARTH MOVING SPECIFICATION ARE
BASED ON THE RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT, BY: TERRACON
CONSULTANTS, INC. DATED: JANUARY 7, 2015
2. FOOTING DESIGNS ARE BASED ON A NET ALLOWABLE SOIL BEARING PRESSURE OF 2800 PSF. FOOTINGS SHALL BEAR IN 30 INCHES MINIMUM BELOW ADJACENT GRADE AS NOTED IN THE GEOTECHNICAL
REPORT.
3. CONTRACTOR AND TESTING LABORATORY REPRESENTATIVE SHALL READ THE GEOTECHNICAL REPORT AND BECOME THOROUGHLY FAMILIAR WITH SITE AND SUBGRADE INFORMATION GIVEN THEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT QUANTITIES OF CUT AND FILL FOR ESTIMATING AND CONSTRUCTION. SUBGRADE SHALL BE PREPARED AS NOTED IN THE EARTH MOVING
SPECIFICATION.
4. A QUALIFIED AND REGISTERED GEOTECHNICAL ENGINEER, LICENSED IN THE STATE WHERE THE
PROJECT IS LOCATED AND WORKING FOR THE TESTING LABORATORY, SHALL DETERMINE
CONFORMANCE OF THE FOUNDATION BEARING STRATA WITH THE FOUNDATION DESIGN CRITERIA
ABOVE, AND ALL OTHER CONTRACT DOCUMENTS. TESTING LABORATORY SHALL NOTIFY CONTRACTOR, ARCHITECT AND ENGINEER-OF-RECORD OF ANY CONDITIONS NOT IN ACCORDANCE WITH FOUNDATION
DESIGN CRITERIA OR CONTRACT DOCUMENTS.
5. USE ONLY STRUCTURAL FILL MATERIAL AS NOTED IN THE SPECIFICATION FOR FILL BELOW BUILDING AND
FIVE FEET BEYOND THE EDGES OF THE BUILDING.
6. FOOTINGS SHALL BE POURED AGAINST UNDISTURBED SOIL, UNLESS NOTED OTHERWISE IN CONTRACT
DOCUMENTS.
7. AVOID DAMAGE TO UNDERGROUND UTILITIES INCLUDING, BUT NOT LIMITED TO, WATER MAINS, SANITARY
SEWERS AND BURIED CABLES WHICH MIGHT EXTEND ACROSS OR ADJOIN SITE.
CONCRETE
1. MINIMUM COMPRESSIVE STRENGTH (f'c) AT THE END OF 28 DAYS SHALL BE AS FOLLOWS:
A. FOOTINGS 3000 PSI
C. SLABS-ON-GRADE 3000 PSI
D. SLABS ON NON-COMPOSITE DECK 3000 PSI
E. INTERIOR TOPPING SLABS 4000 PSI
F. EXTERIOR STRUCTURAL CONCRETE 4500 PSI
G. SIDEWALKS 3500 PSI
REFER TO SPECIFICATIONS FOR MAXIMUM WATER/CEMENT RATIOS, MINIMUM CEMENT CONTENTS AND OTHER MIX DESIGN REQUIREMENTS. CONCRETE SHALL BE NORMAL WEIGHT (145 PCF), UNLESS NOTED
OTHERWISE.
2. EXTERIOR CONCRETE AND CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL BE AIR-ENTRAINED.
REFER TO CAST-IN-PLACE CONCRETE SPECIFICATION FOR AIR CONTENT.
3. MATERIALS OR ADMIXTURES SHALL NOT CONTAIN ANY CALCIUM CHLORIDE.
4. REINFORCING STEEL SHALL MEET THE FOLLOWING:
A. DEFORMED BARS ASTM A615, GRADE 60
B. WELDABLE DEFORMED BARS ASTM A706, GRADE 60
C. WELDED WIRE FABRIC ASTM A185
D. STEEL FIBERS ASTM A820
5. WHERE DOWELS ARE INDICATED BUT NOT SIZED, PROVIDE DOWELS THAT MATCH SIZE AND LOCATION OF MAIN REINFORCING STEEL AND LAP SPLICE WITH THE MAIN REINFORCING STEEL. REINFORCING BARS
SHALL BE SPLICED AS NOTED IN THE REINFORCING LAP SCHEDULE.
6. REFER TO ACI 318 LATEST EDITION FOR CONCRETE COVER, ACI 315 LATEST EDITION FOR DETAILING PRACTICES AND FABRICATION, AND ACI 301 LATEST EDITION FOR STANDARD PRACTICE FOR MIXING AND
PLACING CONCRETE.
7. "C.J." INDICATES SAW CUT CONTRACTION JOINT OR DOWELED CONSTRUCTION JOINT IN SLAB-ON-GRADE.
REFERENCE CAST-IN-PLACE CONCRETE SPECIFICATION FOR ACCEPTED SAW CUT METHODS. SLAB POURS SHALL BE SEPARATED BY A DOWELED CONSTRUCTION JOINT. CONTRACTION/CONSTRUCTION JOINTS SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER-OF-RECORD.
8. PROVIDE CORNER BARS THAT MATCH AND LAP CONTINUOUS REINFORCEMENT SIZE AND QUANTITY AT
INTERSECTIONS AND CORNERS OF WALLS AND FOUNDATIONS.
9. PROVIDE #3 Z-BAR SPACERS AT 24 INCHES ON CENTER EACH WAY FOR CONCRETE WALLS HAVING
REINFORCING STEEL IN BOTH FACES.
10. ANCHORS INSTALLED IN HARDENED CONCRETE SHALL ONLY BE USED WHERE SPECIFIED ON THE CONTRACT DRAWING. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLING POST-INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REINFORCING. HOLES SHALL BE DRILLED, DRY AND CLEANED AND ANCHORS INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S PUBLISHED WRITTEN INSTRUCTIONS AND APPLICABLE ESR REPORT. REFERENCE DETAILS FOR ANCHOR SIZE AND EMBEDMENT. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED ON THE CONTRACT DRAWINGS SHALL BE SUBMITTED BY THE
CONTRACTOR TO THE ENGINEER-OF-RECORD ALONG WITH CALCULATIONS THAT ARE SIGNED AND
SEALED BY THE PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION AND LICENSED IN
THE STATE WHERE THE PROJECT IS LOCATED.
ABBREVIATIONS
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.H. OPPOSITE HAND
P.A.F. POWER ACTUATED FASTENER
P.M.E.J PREMOLDED EXPANSION JOINT
PCF POUNDS PER CUBIC FOOT
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
QTY. QUANTITY
R.O. ROUGH OPENING
RE: REFER
REINF. REINFORCING
REQD. REQUIRED
RTU ROOF TOP UNIT
S.D.S. SELF-DRILLING SCREWS
SCHED. SCHEDULE
SIM. SIMILAR
SPECS. SPECIFICATIONS
STD. STANDARD
STL. STEEL
T&B TOP AND BOTTOM
T.O. TOP OF
T.O.P. TOP OF PIER
T.O.W. TOP OF WALL
TRANS. TRANSVERSE
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
W.P. WORK POINT
W.W.F. WELDED WIRE FABRIC
WT. WEIGHT
ABBREVIATIONS
EQ. EQUAL
EXIST. EXISTING
F.F.E. FINISHED FLOOR ELEVATION
F.S. FAR SIDE
FDN. FOUNDATION
FTG. FOOTING
G.B. GRADE BEAM
GA. GAGE
GALV. GALVANIZED
H.S.A. HEADED STUD ANCHOR
HORIZ. HORIZONTAL
IBC INTERNATIONAL BUILDING
CODE
INFO. INFORMATION
J.B.E. JOIST BEARING ELEVATION
JT. JOINT
K UNIT OF 1,000 POUNDS (KIP)
KSI KIPS PER SQUARE INCH
LBS. POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
MAX. MAXIMUM
MECH. MECHANICAL
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
N.I.C. NOT IN CONTRACT
N.S. NEAR SIDE
N.T.S. NOT TO SCALE
NO. NUMBER
ABBREVIATIONS
A.B. ANCHOR BOLTS
A.F.F. ABOVE FINISHED FLOOR
ACI AMERICAN CONCRETE
INSTITUTE
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
ARCH. ARCHITECTURAL
B.L. BLOCK LINTEL
B.O. BOTTOM OF
B.O.D. BOTTOM OF DECK
BAL. BALANCE
BLDG. BUILDING
BRG. BEARING
C.J. CONTRACTION JOINT
C.L. CENTER LINE
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
D.B.A. DEFORMED BAR ANCHOR
DIA. DIAMETER
DWG. DRAWING
E.F. EACH FACE
E.J. EXPANSION JOINT
E.O.D. EDGE OF DECK
E.O.S. EDGE OF SLAB
E.W. EACH WAY
ELEV. ELEVATION
SPECIAL INSPECTIONS
1. THE GENERAL CONTRACTOR SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS PER SECTION 1704 OF THE IBC. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THESE INSPECTIONS ARE IN
ADDITION TO THE INSPECTIONS SPECIFIED IN THE PROJECT SPECIFICATIONS.
2. SPECIAL INSPECTORS SHALL KEEP RECORDS OF INSPECTIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE AUTHORITY HAVING JURISDICTION, AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. REPORTS SHALL INDICATE THAT WORK INSPECTED WAS DONE IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF THE DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE AUTHORITY HAVING JURISDICTION AND TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE PRIOR TO COMPLETION OF THAT PHASE OF WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS SHALL BE SUBMITTED AT A POINT IN TIME AGREED UPON BY THE PERMIT APPLICANT AND
THE AUTHORITY HAVING JURISDICTION PRIOR TO THE START OF WORK.
3. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE SPECIAL INSPECTOR REGARDING INDIVIDUAL INSPECTION FOR ITEMS LISTED ON THE STATEMENT OF SPECIAL INSPECTIONS AND AS NOTED ON THE AUTHORITY HAVING JURISDICTION APPROVED PLANS. ADEQUATE NOTICE AND ACCESS TO APPROVED PLANS SHALL BE PROVIDED SO THAT THE SPECIAL INSPECTOR HAS TIME TO BECOME FAMILIAR WITH THE PROJECT.
4. FABRICATORS OF STRUCTURAL LOAD-BEARING MEMBERS AND ASSEMBLIES SHALL CONFORM TO THE REQUIREMENTS OF SECTION 1704.2 OF THE
IBC.
STATEMENT OF SPECIAL INSPECTIONS (IBC 2012)
REQUIRED VERIFICATION AND INSPECTION TASK
FREQUENCY OF INSPECTION
CONTINUOUS PERIODIC
I. STEEL CONSTRUCTION (IBC TABLE 1704.3)
1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS AND WASHERS:
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS.
--- X
B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. --- X
2. INSPECTION OF HIGH STRENGTH BOLTING:
A. SNUG-TIGHT JOINT. --- X
B. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITH MATCHMARKING, TWIST-OFF BOLT
OR DIRECT TENSION INDICATOR METHODS OF INSTALLATION.
--- X
C. PRETENSIONED AND SLIP-CRITICAL JOINTS USING TURN-OF-NUT WITHOUT MATCHMARKING OR
CALIBRATED WRENCH METHODS OF INSTALLATION.
X ---
3. MATERIAL VERIFICATION OF STRUCTURAL STEEL AND COLD-FORMED STEEL DECK:
A. FOR STRUCTURAL STEEL, IDENTIFICATION MARKINGS TO CONFORM TO AISC 360. --- X
B. FOR OTHER STEEL, IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE
APPROVED CONSTRUCTION DOCUMENTS.
--- X
C. MANUFACTURER'S CERTIFIED TEST REPORTS. --- X
4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS:
A. IDENTIFICATION MARKINGS TO CONFORM TO AWS SPECIFICATION IN THE APPROVED CONSTRUCTION
DOCUMENTS.
--- X
B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. --- X
5. INSPECTION OF WELDING:
A. STRUCTURAL STEEL AND COLD-FORMED STEEL DECK: --- ---
1) COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS. X ---
2) MULTIPASS FILLET WELDS. X ---
3) SINGLE-PASS FILLET WELDS > 5/16" X ---
4) PLUG AND SLOT WELDS. X ---
5) SINGLE-PASS FILLET WELDS < OR = 5/16" --- X
6) FLOOR AND ROOF DECK WELDS. --- X
B. REINFORCING STEEL: --- ---
1) VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A 706 --- X
2) SHEAR REINFORCEMENT X ---
3) OTHER REINFORCING STEEL. --- X
6. INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE
A. DETAILS SUCH AS BRACING AND STIFFENING. --- X
B. MEMBER LOCATIONS. --- X
C. APPLICATION OF JOINT DETAILS AT EACH CONNECTION. --- X
II. CONCRETE CONSTRUCTION (IBC TABLE 1704.4)
1. INSPECTION OF REINFORCING STEEL AND PLACEMENT. --- X
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1704.3, ITEM 5B. --- ---
3. INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING PLACEMENT OF CONCRETE
WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED.
X ---
4. INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE. --- X
5. VERIFYING USE OF REQUIRED DESIGN MIX. --- X
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
X ---
7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X ---
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. --- X
IV. MASONRY CONSTRUCTION - LEVEL 2 (IBC TABLE 1704.5.2)
1. COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THE
APPROVED SUBMITTALS.
X
2. VERIFICATION OF f'm AND f'aac PRIOR TO CONSTRUCTION AND FOR EVERY 5000 SQUARE FEET DURING
CONSTRUCTION.
X
3. VERIFICATION OF PROPORTIONS OF MATERIALS IN PREMIXED OR PREBLENDED MORTAR AND GROUT AS
DELIVERED TO THE SITE.
X
4. VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED TO THE SITE FOR SELF-CONSOLIDATING GROUT. X ---
5. THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE:
A. PROPORTIONS OF SITE-PREPARED MORTAR, GROUT --- X
B. PLACEMENT OF MASONRY UNITS AND CONSTRUCTION OF MORTAR JOINTS. --- X
C. PLACEMENT OF REINFORCEMENT, CONNECTORS AND ANCHORAGE. --- X
D. GROUT SPACE PRIOR TO GROUTING. X ---
E. PLACEMENT OF GROUT. X ---
F. SIZE AND LOCATION OF STRUCTURAL ELEMENTS. --- X
G. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO
STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION.
X ---
H. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT, ANCHOR BOLTS. --- X
I. WELDING OF REINFORCING BARS. X ---
J. PREPARATION, CONSTRUCTION AND PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE
BELOW 40 DEG. F) OR HOT WEATHER (TEMPERATURE ABOVE 90 DEG. F.)
--- X
6. PREPARATION OF ANY REQUIRED GROUT SPECIMENS AND/OR PRISMS SHALL BE OBSERVED. X ---
V. REQUIRED VERIFICATION AND INSPECTION OF SOILS (IBC TABLE 1704.7)
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING
CAPACITY.
--- X
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. --- X
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. --- X
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
X ---
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY.
--- X
* CONTINUOUS SHALL MEAN: THE FULL-TIME OBSERVATION OF WORK
* PERIODIC SHALL MEAN: THE PART-TIME OR INTERMITTANT OBSERVATION OF WORK AND AT THE
COMPLETION OF WORK
STRUCTURAL STEEL SPECIAL INSPECTIONS (AISC 360-10, SPECIFICATION CHAPTER N)
Verification and Inspection
QUALITY CONTROL (QC) SHALL BE PROVIDED BY THE FABRICATOR AND ERECTOR
A. THE FABRICATOR'S QUALITY CONTROL INSPECTOR (QCI) SHALL INSPECT THE FOLLOWING:
1. SHOP WELDING, HIGH-STRENGTH BOLTING, AND DETAILS PER SECTION N5
2. SHOP CUT AND FINISHED SURFACES PER SECTION M2
3. SHOP HEATING FOR STRAIGHTENING, CAMBERING AND CURVING PER SECTION M2.1
4. TOLERANCES FOR SHOP FABRICATION PER SECTION 6 OF THE CODE OF STANDARD PRACTICE
B. THE ERECTOR'S QUALITY CONTROL INSPECTOR (QCI) SHALL INSPECT THE FOLLOWING:
1. FIELD WELDING, HIGH-STRENGTH BOLTING, AND DETAILS PER SECTION N5
2. STEEL DECK AND HEADED STEEL STUD ANCHOR PLACEMENT AND ATTACHMENT PER SECTION N6
3. FIELD CUT SURFACES PER SECTION M2.2
4. FIELD HEATING FOR STRAIGHTENING PER SECTION M2.1
5. TOLERANCES FOR FIELD ERECTION PER SECTION 7.13 OF THE CODE OF STANDARD PRACTICE
QUALITY ASSURANCE (QA) SHALL BE PROVIDED BY OTHERS WHEN REQUIRED BY THE AUTHORITY HAVING JURISDICTION (AHJ), APPLICABLE BUILDING CODE (ABC), PURCHASER, OWNER, OR ENGINEER OF RECORD (EOR). NONDESTRUCTIVE TESTING (NDT) SHALL
BE PERFORMED BY THE AGENCY OR FIRM RESPONSIBLE FOR QUALITY ASSURANCE
C. QUALITY ASSURANCE (QA) INSPECTION OF FABRICATED ITEMS SHALL BE MADE AT THE FABRICATOR'S PLANT. QA INSPECTION OF THE
ERECTED STEEL SYSTEM SHALL BE MADE AT THE PROJECT SITE
1. QA INSPECTIONS, EXCEPT NDT, MAY BE WAIVED WHEN THE WORK IS PERFORMED IN A FABRICATING SHOP OR BY AN ERECTOR
APPROVED BY THE AHJ TO PERFORM THE WORK WITHOUT QA
2. NDT OF WELDS COMPLETED IN AN APPROVED FABRICATOR'S SHOP MAY BE PERFORMED BY THAT FABRICATOR WHEN APPROVED BY THE AHJ. WHEN THE FABRICATOR PERFORMS THE NDT, THE QA AGENCY SHALL REVIEW THE FABRICATOR'S NDT REPORTS
3. AT COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE AHJ STATING THAT THE MATERIALS SUPPLIED AND WORK PERFORMED BY THE FABRICATOR ARE IN ACCORDANCE WITH THE CONSTRUCTION
DOCUMENTS
4. AT COMPLETION OF ERECTION, THE APPROVED ERECTOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE AHJ STATING THAT THE MATERIALS SUPPLIED AND WORK PERFORMED BY THE ERECTOR ARE IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS
5. THE QUALITY ASSURANCE INSPECTOR (QAI) SHALL REVIEW MATERIAL TEST REPORTS AND CERTIFICATIONS AS LISTED IN SECTION N3.2
FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS
INSPECTION TASKS LISTED IN THE TABLES BELOW SHALL BE PERFORMED BY BOTH THE FABRICATOR'S/ERECTOR'S QUALITY CONTROL INSPECTOR (QCI) AND THE QUALITY ASSURANCE INSPECTOR (QAI) UNLESS NOTED OTHERWISE:
INSPECTION TASKS PRIOR TO WELDING (AISC 360-10, TABLE N5.4-1) PERFORM OBSERVE
1. WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE X ---
2. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE X ---
3. MATERIAL IDENTIFICATION (TYPE/GRADE) --- X
4. WELDER IDENTIFICATION SYSTEM (a) --- X
5. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
A. JOINT PREPARATION --- X
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) --- X
C. CLEANLINESS (CONDITION OF STEEL SURFACES) --- X
D. TACKING (TACK WELD QUALITY AND LOCATION) --- X
E. BACKING TYPE AND FIT (IF APPLICABLE) --- X
6. CONFIGURATION AND FINISH OF ACCESS HOLES --- X
7. FIT-UP OF FILLET WELDS --- X
A. DIMENSIONS (ALIGNMENT, GAPS AT ROOT) --- X
B. CLEANLINESS (CONDITION OF STEEL SURFACES) --- X
C. TACKING (TACK WELD QUALITY AND LOCATION) --- X
8. CHECK WELDING EQUIPMENT (b) --- X
(a) THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS
TYPE.
(b) THIS INSPECTION TASK IS THE SOLE RESPONSIBILITY OF THE FABRICATOR'S/ERECTOR'S QUALITY
CONTROL INSPECTOR (QCI)
INSPECTION TASKS DURING WELDING (AISC 360-10, TABLE N5.4-2) PERFORM OBSERVE
1. USE OF QUALIFIED WELDERS --- X
2. CONTROL AND HANDLING OF WELDING CONSUMABLES --- X
A. PACKAGING --- X
B. EXPOSURE CONTROL --- X
3. NO WELDING OVER CRACKED TACK WELDS --- X
4. ENVIRONMENTAL CONDITIONS --- X
A. WIND SPEED WITHIN LIMITS --- X
B. PRECIPITATION AND TEMPERATURE --- X
5. WELDING PROCEDURE SPECIFICATION (WPS) FOLLOWED
A. SETTINGS ON WELDING EQUIPMENT --- X
B. TRAVEL SPEED --- X
C. SELECTED WELDING MATERIALS --- X
D. SHIELDING GAS TYPE / FLOW RATE --- X
E. PREHEAT APPLIED --- X
F. INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.) --- X
G. PROPER POSITION (F, V, H, OH) --- X
6. WELDING TECHNIQUES --- X
A. INTERPASS AND FINAL CLEANING --- X
B. EACH PASS WITHIN PROFILE LIMITATIONS --- X
C. EACH PASS MEETS QUALITY REQUIREMENTS --- X
INSPECTION TASKS AFTER WELDING (AISC 360-10, TABLE N5.4-3) PERFORM OBSERVE
1. WELDS CLEANED --- X
2. SIZE, LENGTH AND LOCATION OF WELDS X ---
3. WELDS MEET VISUAL ACCEPTANCE CRITERIA
A. CRACK PROHIBITION X ---
B. WELD/BASE-METAL FUSION X ---
C. CRATER CROSS SECTION X ---
D. WELD PROFILES X ---
E. WELD SIZE X ---
F. UNDERCUT X ---
G. POROSITY X ---
4. ARC STRIKES X ---
5. k-AREA (a) X ---
6. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED) X ---
7. REPAIR ACTIVITIES X ---
8. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER X ---
9. ULTRASONIC TESTING (UT) ON ALL CJP GROOVE WELDS IN BUTT, T- AND CORNER JOINTS, IN MATERIALS 5/16 IN. THICK OR GREATER. (required in Risk Category III or IV)
X ---
10. ULTRASONIC TESTING (UT) ON 10% OF CJP GROOVE WELDS IN BUTT, T- AND CORNER JOINTS, IN MATERIALS 5/16 IN. THICK OR GREATER (required in Risk Category II)
X ---
11. THERMALLY CUT SURFACES OF ACCESS HOLES SHALL BE TESTED USING MAGNETIC PARTICLE TESTING (MT) OR PENETRANT TESTING (PT), WHEN FLANGE THICKNESS EXCEEDS 2 IN. FOR ROLLED SHAPES, OR
WHEN THE WEB THICKNESS EXCEEDS 2 IN. FOR BUILT-UP SHAPES.
X ---
12. (see AISC 360-10, section N5-5d for additional special inspections for welded joints subject to fatigue)
(a) WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA FOR CRACKS WITHIN 3 IN. OF THE WELD.
PERFORM - PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER.
OBSERVE - OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED
PENDING THESE INSPECTIONS.
INSPECTION TASKS PRIOR TO BOLTING (AISC 360-10, TABLE N5.6-1) PERFORM OBSERVE
1. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS (QAI ) X (QCI) X
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS --- XXX
3. PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH) --- XXX
4. PROPER BOLTING PROCEDURES SELECTED FOR JOINT DETAIL --- XXX
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE
PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS.
--- XXX
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND
DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED (a)
(QCI) X (QAI) X
7. PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS --- X
(a) NOT APPLICABLE FOR SNUG TIGHT JOINTS
INSPECTION TASKS DURING BOLTING (AISC 360-10, TABLE N5.6-2) (a) PERFORM OBSERVE
1. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS (IF REQUIRED)
ARE POSITIONED AS REQUIRED
--- X
2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION --- X
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING (b) --- X
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES (b)
--- X
(a) NOT APPLICABLE FOR SNUG TIGHT JOINTS
(b) FOR PRETENSIONED JOINTS AND SLIP-CRITICAL JOINTS, WHEN THE INSTALLER IS USING THE TURN-OF-NUT METHOD WITH MATCHMARKING TECHNIQUES, THE DIRECT-TENSION-INDICATOR METHOD, OR THE TWIST-OFF-TYPE TENSION CONTROL BOLT METHOD, THE QCI AND QAI NEED NOT BE PRESENT
DURING THE INSTALLATION OF FASTENERS
INSPECTION TASKS AFTER BOLTING (AISC 360-10, TABLE N5.6-3) PERFORM OBSERVE
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS X ---
PERFORM - PERFORM THESE TASKS FOR EACH BOLTED CONNECTION.
OBSERVE - OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED
PENDING THESE INSPECTIONS.
OTHER INSPECTION TASKS (AISC 360-10, SECTION N5.7) PERFORM OBSERVE
1. INSPECT THE STEEL TO VERIFY COMPLIANCE WITH THE DETAILS SUCH AS BRACES, STIFFENERS, MEMBER LOCATIONS AND PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION
X ---
2. INSPECT THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. THE DIAMETER, GRADE, TYPE AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO
THE CONCRETE, SHALL BE VERIFIED PRIOR TO PLACEMENT OF CONCRETE
X ---
PERFORM - PERFORM THESE TASKS FOR EACH CONNECTION
INSPECTION OF STEEL ELEMENTS OF COMPOSITE CONSTRUCTION PRIOR TO CONCRETE PLACEMENT
(AISC 360-10, TABLE N6.1)
PERFORM OBSERVE
1. PLACEMENT AND INSTALLATION OF STEEL DECK X ---
2. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS X ---
3. DOCUMENT ACCEPTANCE OR REJECTION OF STEEL ELEMENTS X ---
PERFORM - PERFORM THESE TASKS FOR EACH STEEL ELEMENT.
78' - 4 1/2" 20' - 3 1/2"
/1
/1
(2) EQUAL SPACES(5) EQUAL SPACES
(3
E Q
U A
L S
P A
C E
S
CJ
CJ
CJ
C J
C J
C J
C J
C J
C J
C J
C J
C J
C J
4" CONCRETE SLAB ON GRADE
REINFORCED WITH 6x6 W2.9xW2.9
1" CLEAR BELOW SURFACE.
PROVIDE 15 MIL VAPOR RETARDER
BELOW SLAB AND ON TOP OF 4"
DRAINAGE COURSE.
BL
TOF = 98'-8"
S200
TYP
BL BL
S200
TYP
S200
TOF = 99'-4" TYP
TOF = 99'-4" TYP
(6) EQUAL SPACES
(3
E Q
U A
L S
P A
C E
S
S200
TOF = 99'-4 TYP"
B L
B L
S200
TYP
BLBLBLBLBL
TOF = 98'-8 TYP"
S200
TYP
S200
B L
FINISH FLOOR EL, TYP
100'-0"
TOF = 98'-8 TYP"
(2) EQUAL SPACES
S200
B L
B L
S200
C J
S200
(2
E Q
U A
L S
P A
C E
S (2
E
Q U
A L S
P A
C E
S
S200
TYP
S200
TYP
TOF = 98'-8"
S200
TYP
CJ
CJ
CJ
C J
(2) EQUAL SPACES
AA
BB
CC
4' - 0" 8' - 0" 23' - 4" 12' - 0" 4' - 0" 8' - 0" 7' - 4" 8' - 0"
BL BL BL BL BL BL BL BL BL
26' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 2' - 8" 3' - 4" 20' - 8"
RE: MECH FOR HVAC
OPENING LOCATIONS ALONG
THIS WALL. PROVIDE LINTELS
AND JAMBS PER 8-S200.
OPENING LOCATIONS SHALL
NOT INTERUPT JAMB
REINFORCING FOR DOOR
OPENINGS BELOW 6
FUTURE
KNOCKOUT
OPENING.
PROVIDE LINTELS
AND JAMBS PER
SCHEDULE
32' - 0" 31' - 4"
22' - 8"
RE: MECH FOR HVAC
OPENING LOCATIONS
ALONG THIS WALL.
PROVIDE LINTELS AND
JAMBS PER 8-S200.
OPENING LOCATIONS
SHALL NOT INTERUPT JAMB
REINFORCING FOR DOOR
OPENINGS BELOW
A.2A.2
A.3A.3
HSS3-1/2X3-1/2X3/16
HSS3-1/2X3-1/2X3/16HSS3-1/2X3-1/2X1/4
HSS3-1/2X3-1/2X1/4
/4
/4
34' - 5 5/8" 13' - 6 7/8"
S200
TYP
DENOTES CONSTRUCTION OR CONTROL JOINT
(CONTRACTOR'S OPTION), RE: TYPICAL SLAB DETAIL, S200
DENOTES TOP OF FOOTINGTOF
CJ
ELEVATIONS INDICATED ON PLANS ARE TO FINISHED FLOOR, UNO.
DENOTES MASONRY BLOCK LINTEL ABOVE RE: MASONRY DETAILS, S200BL
DEONTES JAMB WIDTH MODIFICATION, RE: 8-S200
DEONOTES CONTROL JOINTS IN MASONRY WALL, RE: 8-S200
R
E
V
I
S
I
O
C
K
C
O
N
T
R
A
C
T
D
E
S
I
G
N
E
N
T
I
F
I
C
A
T
I
O
N
S
T
A
A
L
O
W
N
E
N
T
I
F
I
C
A
T
I
O
N
B
U
I
L
D
I
N
G
P
R
O
J
E
C
T
S
H
E
E
T
U.S. Department of Justice Federal Bureau of Prisons
U.S. Medical Center for Federal Prisoners 1900 West Sunshine
Springfield, MO 65807
CONST. CONTRACT NO.
DELIVER ORDER NO.
A/E CONTRACT NO.
BUILDING NAME
ADDRESS
CITY, STATE, ZIP
BUILDING NO.
PROJECT TITLE
SUBMISSION STAGE
SUBMISSION DATE
DRAWN BY
CHECKED BY
FLOOR NO.
DISCIPLINE
PLAN TYPE
SHEET NUMBER
AND FILENAME
P R
O P
E R
T Y
O F
T H
E U
N
IT
E D
S T
A T
E S
G O
V E
R N
M E
N T
S E
N S
IT
IV
E B
U T
U N
C L
A S
S
IF
IE
D
P ro p e rl y d e s tr o y d o c u m e n ts m e d ia w h e n n o l o n g e r n e e d e d
D
E
S
I
G
N
E
N
T
I
F
I
C
A
T
I
O
N
Medical Reference Laboratory
Springfield, Missouri, 65807
Final Construction Documents
11/25/2015
Wallace Engineering - Structural Consultants, Inc.
Professional Engineering Corporation Missouri Certificate of Aurthorization #001268
SPG PROJECT 4B2J
/2
/2
:3 :2
P
M
S100
Construct Medical Reference Lab
JJM
DLS
1900 West Sunshine
FOUNDATION PLAN
1/4" = 1'-0"1FOUNDATION PLAN
FOUNDATION PLAN NOTES AND LEGEND
-- TOF ARE MAXIMUM ELEVATIONS. AT CONTRACTORS OPTION THESE MAY BE ALTERED AFTER REVIEW OF PROPOSED CHANGES BY THE ENGINEER.
-- RE: ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN.
-- COORDINATE ELEVATION OF BRICK LEDGE WITH ARCHITECTURAL AND FINISH GRADE.
OPENING
PLAN
1/4" JOINT FILLER
#4 BAR AT DOOR
#4 BAR
EDGE OF SLAB
EXTERIOR FACE
OF WALL BEYOND
3"
3"
FF ELEV.
RE: PLAN
GRID
TOP OF FOOTING
RE: FND. PLAN
PLAN
GRID
D O
O R
O P
E N
IN
G
3'-0" TYP.
RE: EXTERIOR WALL
FOOTING DETAIL FOR
INFORMATION
1/4"x1 1/2" DEEP SAWCUT CONTROL JOINT.
(1/4"x3/4" IF SOFT CUT OPTION IS USED). FILL
WITH SEALANT AT EXPOSED JOINTS, AND
FILL WITH SUBFLOOR FILLER UNDER TILE
AND CARPET. RE: SPECIFICATIONS.
CONTROL JOINT (C.J.)
CONSTRUCTION JOINT (CONST.JT.)
AT CONTRACTORS OPTION, PROVIDE
1/2" DIA.x2'-0" SMOOTH DOWELS
GREASED, ONE END OR DIAMOND DOWEL
SYSTEM BY PNA (OR APPROVED EQUAL).
SPACE AT 2'-0" O.C. MAX.
1' - 0" 1' - 0"
2' - 0" 2' - 0"
C L R
CONCRETE REINFORCING
LAP SCHEDULE
BAR NO.
#3
#4
#5
#7
#8
#9
#10
#11
TOP BARS
15"
20"
25"
48"
61"
75"
91"
109"
LAP
OTHERS
15"
19"
23"
47"
58"
70"
84"
12"
#6 29"
37"
CMU REINFORCING
LAP SCHEDULE
BAR NO.
#3
#4
#5
#7
#8
18"
24"
30"
42"
48"
LAP
SPLICES
#6 36"
CORNER BARS TO
MATCH HORIZ REINF.
LAP BARS PER
SCHEDULE.
HORIZ REINF TYP
FF EL
RE: PLAN
TOP OF FOOTING
RE: FND. PLAN
BO FOOTING
97'-0"
(3)-#5 BARS CONT
FOUNDATION DOWELS TO MATCH
SIZE AND SPACING. PLACE HOOKS
DIRECTLY ON TOP OF CONTINUOUS
BARS. ALTERNATE DIRECTION OF
HOOKS. RE: LAP SPLICE SCHEDULE.
ALL MASONRY BELOW GRADE
TO BE GROUTED SOLID.
PROVIDE JOINT FILLER AT
EXTERIOR SLAB.
CL CMU AND FOOTING.
PROVIDE FELT BOND BREAKER
AT INTERIOR SLAB.
C L R
2' - 0"
RE: CMU WALL REINFORCING
DIAGRAM FOR ADDITIONAL
INFORMATION
VENEER, RE: ARCH
TOP OF FOOTING
RE: FND. PLAN
(3)-#5 BARS CONT
FOUNDATION DOWELS. PLACE HOOKS
DIRECTLY ON TOP OF CONTINUOUS
BARS. ALTERNATE DIRECTION OF
HOOKS. RE: LAP SPLICE SCHEDULE.
ALL MASONRY BELOW GRADE
TO BE GROUTED SOLID.
CL CMU AND FOOTING.
PROVIDE FELT BOND BREAKER
TYP
2' - 0"
RE: CMU WALL REINFORCING
DIAGRAM FOR ADDITIONAL
INFORMATION
C L R
(3)-#5 CONTINUOUS
2' - 0"
T.O.S. ELEV.
RE: FND. PLAN
AT OPENING PROVIDE (3)-#5xLENGTH OF
OPENING WITH 5'-0" EXTENSION ON EACH
SIDE OF OPENING.
RE: FOUNDATION PLAN FOR
SLAB AND REINFORCING.
C.L. WALL AND THICKENED SLAB.
RE: FND. PLAN.
#5 AT 12" O.C.x6'-0" LONG
CENTERED ON WALL.
CMU WALL REINFORCING.
RE: MASONRY DETAILS.
NOTES:
1. REFER CMU REINFORCING DIAGRAM FOR SPLICES IN VERTICAL REINFORCING.
2. BOND BEAM.
3. EXTEND GROUTED LINTEL A MINIMUM OF 2'-0" BEYOND FACE OF OPENING EACH
SIDE FOR STRAIGHT LINTEL REINFORCEMENT AND 1'-4" FOR HOOKED LINTEL, UNO
REINFORCEMENT WITH STANDARD ACI HOOK.
4. USE LINTEL BLOCKS ONLY FOR BOTTOM COURSE OF LINTEL BEAMS.
5. CONTINUE VERTICAL REINFORCING INTO LINTEL BEAM WITH STANDARD ACI HOOK.
6. PROVIDE DOWELS TO MATCH ALL VERTICAL REINFORCING LOCATIONS.
7. ALL VERTICAL BARS AT JAMBS AND PILASTERS SHALL EXTEND FROM THE BOND
BEAM BELOW THE OPENING TO THE BOND BEAM ABOVE THE OPENING.
8. CONTINUE HORIZONTAL REINFORCING INTO JAMB AND PROVIDE STANDARD ACI
HOOK INTO END CELL
9. BOND BEAM AT FIRST FULL COURSE BELOW ROOF FRAMING. VERTICALLY
REINFORCE TO TOP OF WALL PER REINFORCING DETAIL
10. BOND BEAM AT TOP OF WALL.
GENERAL NOTES:
12. GROUT SOLID ALL CELLS WITH REINFORCING.
13. USE BOND BEAM BLOCKS WITH OPEN BOTTOMS ONLY AT BOND BEAM LOCATIONS.
DO NOT USE TROUGH-TYPE BLOCKS AT BOND BEAMS.
14. DO NOT CONTINUE BOND BEAM REINFORCING TROUGH CONTROL JOINTS
15. ALL MASONRY SHALL BE LAID IN RUNNING (COMMON) BOND.
16. REFER TO DETAILS FOR LOCATIONS OF ADDITIONAL BOND BEAMS.
17. HORIZ. JOINT REINFORCING SHALL BE GALV. LADDER TYPE SPACED AT 16" OC
ABOVE GRADE AND 8" OC BELOW GRADE AND IN PARAPETS.
18. MASONRY REQUIRES SPECIAL INSPECTION. RE: SPECIFICATIONS.
19. MASONRY DESIGN IS BASED UPON A MINIMUM COMPRESSIVE STRENGTH OF fm =
2000 PSI, ESTABLISHED IN A ACCORDANCE WITH THE UNIT STRENGTH METHOD,
UNO
20. MASONRY UNITS SHALL MEET THE REQUIREMENTS OF ASTM C90 WITH A NET AREA
COMPRESSIVE STRENGTH OF 2800 PSI, UNO. MASONRY UNITS SHALL BE NORMAL
WEIGHT (MORE THAN 125 PCF).
21. MORTAR SHALL BE PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM
C270 (USE STANDARD 21-15) FOR TYPE "S" MORTAR
22. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.
BATCHING AND MIXING SHALL MEET THE REQUIREMENTS OF ASTM C476
23. CONSTRUCTION BRACING FOR MASONRY WALL SHALL BE DESIGNED BY A
PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WITCH THE PROJECT IS
LOCATED. MASONRY SUBMITTALS SHALL CONTAIN A LETTER SEALED BY
ENGINEER, STATING DESIGN LOADS AND SEALED BY THE ENGINEER AND SHALL BE
ISSUED TO THE OWNER AFTER SUBMITTAL REVIEW AND PRIOR TO STARTING
MASONRY CONSTRUCTION.
TOF
RE: FND PLAN
FINISH FLOOR
RE: FND PLAN
TOJ EL
RE: ROOF PLAN
TOP OF PARAPET
RE: ARCH
RE: JAMB
DETAIL
R E
L
IN
T E
L D
E T
A
IL
LAP BARS AT BAR POSITIONER
#3 BAR WITH ACI STANDARD 180
DEGREE HOOK IN EACH VERT. REINF.
CELL, TYP. UNO.
BOND BEAM AT TOP OF WALL
BAR POSITIONER AT 8" MAXIMUM
ABOVE TOP OF GROUT LIFT, TYP.
PROVIDE HORIZONTAL JOINT REINF.
AT 16" OC ABOVE GRADE AND 8" OC
BELOW GRADE AND IN PARAPETS
NORMAL WEIGHT CMU. PROVIDE (1) #5
VERT AT 40" OC, MAX
HOLD TOP OF EACH GROUT LIFT 2" DOWN
BELOW TOP OF BLOCK TO PROVIDE KEY
FOR NEXT LIFT, TYP.
FOUNDATION DOWEL INTO FOOTING
BELOW WITH STD 90 DRG HOOK,
ALTERNATE DIRECTION. DOWEL SIZE
AND SPACING TO MATCH WALL REINF
BOND BEAM
FULLY GROUTED NORMAL
WEIGHT CMU BELOW GRADE
MUST COURSE WITH FINISHED
FLOOR
VERTICAL CONTROL JOISTS SHALL
TERMINATE AT TOP OF FOOTING
LEVELING MORTAR BED
BELOW FIRST COURSE
SECTION
R E
L A
P S
C H
E D
U L E
/2
S L R
FIN FLOOR ELEVATION
FOUNDATION PLAN
8" WALL
W/2W/2
W
ALL BOND BEAMS SHALL HAVE
(1) #5 BAR CONTINUOUS.
PROVIDE VERT. WALL REINF. IN FIRST
CELL EACH SIDE OF CONTROL JOINT
REINF. BARS, JOINT REINF. AND BOND
BEAMS SHALL BE DISCONTINUOUS
DOWN TO TOP OF FOOTING AT
CONTROL JOINTS. RE: FOUNDATION
PLAN FOR CONTROL JOINT
LOCATIONS. DO NOT LOCATE
CONTROL JOINT WITHIN 2'-0" OF
OPENINGS.
PROVIDE VERT. WALL
REINF. IN CORNER
CELL AS SHOWN.
INSTALL CORNER BAR TO
MATCH AND LAP WITH
BOND BEAM
REINFORCING
EXTEND HORIZONTAL
REINFORCING TO END OF
WALL IN BOTH DIRECTIONS.
3/8" JOINT
EXPANSION CONTROL JOINT DETAIL
BOND BEAM STEP (NOT AT CONTROL JOINT)
RE: LAP SCHEDULE
TYPICAL 8" CORNER
CORNER DETAIL
AT OPENING ABOVE FINISH FLOOR
PROVIDE LINTEL AND JAMB PER
SCHEDULE. PROVIDE (1) #5 SILL BAR
IN FIRST FULL COURSE BELOW
OPENING AND GROUT SOLID TO
OPENING. EXTEND SILL REINF 2'-0"
BEYOND EDGES OF OPENING
N O
M
IN
A L
D
(NOM.)
W
LINTEL
EQ EQ
8"
8"
8"
WIDTH
(W)
GROUT ALL REINFORCED
CELLS AND CONTINUE
REINFORCING TO FULL HEIGHT
OF WALL, TYP
SIZE BARS TO MATCH VERTICAL
CMU WALL REINF PROVIDE (1)
BAR EACH CELL FOR LENGTH
REQUIRED
JAMB
CLEAR SPAN
UP TO 4'-8"
UP TO 6-'0"
UP TO 8'-0"
8"
24"
32"
(1) #6 BOTTOM
(1) #6 T&B
(1) #6 T&B
DEPTH
(D)
BOTTOM
REINF.
CMU LINTEL SCHEDULE
E Q
E Q
16" AT OPENING UP TO 8'-0"
8" AT OPENINGS UP TO 8'-0" AT LOCATIONS DENOTED WITH
24" AT OPENINGS LARGER THAN 8'-0"
/2
10"x10"x1/2" BASE PLATE AND 3/4" DIA
ANCHOR RODS, EMBED BOLTS 8",
TYP.
(3) #4 BARS EW
WATERPROOF COLUMN,
ANCHOR BOLTS AND BASE
PLATE WITH ASPHALTIC MASTIC
COLUMN, RE: FND. PLAN
PROVIDE 3/16" WASHERS. WELD
WASHER TO TOP OF BASE
PLATE
CL COLUMN AND FOOTING
TOF EL
99'-0"
FIN. FLOOR
RE: FND PLAN
1 1/2" NON-SHRINK GROUT
C L R
2'-0" (x2'-0")
TYP
1 1/2"
TYP.
R
E
V
I
S
I
O
C
K
C
O
N
T
R
A
C
T
D
E
S
I
G
N
E
N
T
I
F
I
C
A
T
I
O
N
S
T
A
A
L
O
W
N
E
N
T
I
F
I
C
A
T
I
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .