SALIENT CHARACTERISTICS 15PA-02-01 Transmitter Refresh

CLIN 0001: 100W FM 107.9MHz, Main/Alt configuration (AFN-E/Netherlands/Volkel/AFN Benelux)

1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration

2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator

9. Front Panel Control

10. Automatic transmitter switcher

11. RF switch

12. RF output Low Pass Filter

13. Rack cabinets

14. Remote Control Unit that is GSM (cellular) Modem Compatible

Frequency 107.9MHz

CLIN 0002: 2000W FM 101.7MHz, Main/Alt configuration (AFN-E/Belgium/Brussels/Everberg/AFN Benelux)

1. Two 1000-5000W FM Digital transmitters/exciters in Main/Alternate configuration

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator

9. Front Panel Control

10. Automatic transmitter switcher

11. RF switch

12. RF output Low Pass Filter

13. Rack cabinets

Frequency 101.7MHz

CLIN 0003: 250W FM 106.2MHz, Main/Alt configuration (AFN-E/Belgium/Kleine Brogel/AFN Benelux)

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator

9. Front Panel Control

10. Automatic transmitter switcher

11. RF switch

12. RF output Low Pass Filter

13. Rack cabinets

Frequency 106.2MHz

CLIN 0004: 250W FM 106.5MHz, Main/Alt configuration (AFN-E/Belgium/Shape/AFN Benelux)

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator

9. Front Panel Control

10. Automatic transmitter switcher

11. RF switch

12. RF output Low Pass Filter

13. Rack cabinets

Frequency 106.5MHz

CLIN 0005: 250W FM 107.3MHz, Main/Alt configuration (AFN-E/Greece/Souda Bay, Crete/AFN Souda Bay)

1. Two 100W - 300W FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

15. Low Pass Filter

16. Rack cabinets

17. Remote Control Unit that is GSM (cellular) Modem Compatible

Frequency 107.3MHz

CLIN 0006: 5000W FM 105.9MHz, Main/Alt configuration (AFN-E/Italy/Sigonella/AFN Sigonella)

1. Two 5000W FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

15. Low Pass Filter

16. Rack cabinets

Frequency 105.9MHz

CLIN 0007: 5000W FM 106.0MHz, Main/Alt configuration (AFN-E/Italy/Vicenza/AFN Vicenza)

1. Two 5000W FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

15. Low Pass Filter

16. Rack cabinets

17. Remote Control Unit that is GSM (cellular) Modem Compatible

Frequency 106.0MHz

CLIN 0008: 500W FM 106.5MHz, Main/Alt configuration (AFN-E/Honduras/Soto Cano Honduras/AFN Honduras)

1. Two 500W-1KW FM Digital transmitters/exciters in Main/Alternate configuration

3. Power Factor: 0.90 or better

4. Output Impedance: 50 ohms

5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations

6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

7. Analog, composite, and AES inputs.

a. AES Impedance: 100-110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

8. Stereo generator

9. Front Panel Control

10. Automatic transmitter switcher

11. RF switch

12. RF output Low Pass Filter

13. Rack cabinets

Frequency 106.5MHz

CLIN 0009: 500W FM 102.1MHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)

1. Two 500W-1KW FM transmitters in Main/Alternate configuration

2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

15. Low Pass Filter

16. Rack cabinets

Frequency 102.1MHz

CLIN 0010: 500W FM 103.1MHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)

1. Two 500W-1KW FM transmitters in Main/Alternate configuration

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

Frequency 103.1MHz

CLIN 0011: 1kW AM 1340KHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)

1. Two 1KW AM transmitters in Main/Alternate configuration

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

15. Remote Control Unit that is GSM (cellular) Modem Compatible

Frequency 1340KHz

CLIN 0012: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Iwakuni/AFN Iwakuni)

2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

Frequency 1575KHz

CLIN 0013: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Misawa/AFN Misawa)

2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

CLIN 0014: 1kW FM 89.1MHz, Main/Alt configuration (AFN-P/Japan/Camp Foster/AFN Okinawa)

1. Two 1KW FM transmitters in Main/Alternate configuration

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

Frequency 89.1MHz

CLIN 0015: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Sasebo/AFN Sasebo)

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

CLIN 0016: 10kW AM 648KHz, Main/Alt configuration (AFN-P/Japan/Okinawa-Camp Kinzer/AFN Okinawa/)

3. Efficiency: 60% or better

4. Power Factor: 0.70 or better

5. Output Impedance: 50 ohms

6. Redundant Power Supplies

7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

10. Analog, composite

a. Impedance: 600 Ohm Balanced

11. Automatic transmitter switcher

12. Front Panel Metering

13. RF switch.

14. Rack cabinets

Frequency 648KHz

CLIN 0017: 250W FM 99.1MHz, Main/Alt configuration (AFN-P/AFN Diego Garcia)

1. Two 100-300W FM transmitters in Main/Alternate configuration

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

14. RF switch

15. Low Pass Filter

16. Rack cabinets

Frequency 99.1MHz

CLIN 0018: 250W FM 101.9MHz, Main/Alt configuration (AFN-P/AFN Diego Garcia)

1. Two 100-300W FM transmitters in Main/Alternate configuration

3. Efficiency: 50% or better

4. Power Factor: 0.90 or better

5. Output Impedance: 50 ohms

6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.

7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements

8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions

9. Analog, composite, and AES inputs

a. AES Impedance: 110 Ohm balanced

b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced

10. Stereo generator

11. IP Connectivity

12. Front Panel Control and Metering

13. Automatic transmitter switcher

Frequency 101.9MHz

CLIN 0019: Antenna Tuning Unit (AFN-P/Japan/Sasebo/AFN Sasebo)

1. Transmitter Frequency is 1575KHz

2. Transmitter Power is 1000W

3. The measured impedance is 87 +j60 ohms

4. The tower height is 45 meters self-supporting type with a triangular cross section

5. The tower Face Width is proportional with a 5.6 meters triangular section at the bottom and a 70 centimeters top triangular section.

6. The tower is shunt fed. (Folded Type Down Lead Antenna or Folded Unipole)

7. The unipole skirt kit height on the tower is 45 meters

8. The level of the lower shorting ring is 20m

9. The tower has 9 skirt wires, 22 square gauge, straight off the face centers

10. The standoff distance of the wires from the tower is 2.5m diameter at the top and 5m at the bottom

11. The shorting stub wires level is 40m L1, 20m L2 shorting ring

12. No specific existing restrictions for isolation

13. The Input Transmission line impedance is 50ohms using RG-218/U(RG-17A/U) as a transmission line

14. The connection type and size is open wire

15. The required RF current metering is a Toroidal style out RF current meter

16. The current transmission line length from transmitter output to ATU input is ~60m

17. There is a need to use the existing mounting steel plate (400mmx400mmx4.5mm) and cable feed.

CLIN 0020: Antenna Tuning Unit (AFN-P/Korea/Camp Carroll/AFN Daegu)

1. Transmitter Frequency: 1440 KHz

2. Transmitter Power: 5000W

3. The measured impedance: Not at This Time

4. The tower height is 180 ft. guyed tower type with a triangular cross section

5. The tower Face Width is 18 inches

6. The tower is Series Fed Base Isolated.

7. Restrictions for isolation: See below picture

8. The Input Transmission line impedance is 50 ohms nominal.

9. The connection type and size is 1 7/8 inch.

10. The required RF current metering is a Toroidal style out RF current meter

11. The current transmission line length from transmitter output to ATU input is ~100 ft.

12. The dimensions are 52”L x 34” W x 42” H It has 34.5” legs and sits on a concrete base of 68” x 44”