SALIENT CHARACTERISTICS 15PA-02-01 Transmitter Refresh
CLIN 0001: 100W FM 107.9MHz, Main/Alt configuration (AFN-E/Netherlands/Volkel/AFN Benelux)
1. Two 100W - 300W FM Digital transmitters/exciters in Main/Alternate configuration
2. AC Input Voltage: 110/220VAC, 50/60Hz, Single-Phase
3. Power Factor: 0.90 or better
4. Output Impedance: 50 ohms
5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations
6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
7. Analog, composite, and AES inputs.
a. AES Impedance: 100-110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
8. Stereo generator
9. Front Panel Control
10. Automatic transmitter switcher
11. RF switch
12. RF output Low Pass Filter
13. Rack cabinets
14. Remote Control Unit that is GSM (cellular) Modem Compatible
Frequency 107.9MHz
CLIN 0002: 2000W FM 101.7MHz, Main/Alt configuration (AFN-E/Belgium/Brussels/Everberg/AFN Benelux)
1. Two 1000-5000W FM Digital transmitters/exciters in Main/Alternate configuration
3. Power Factor: 0.90 or better
4. Output Impedance: 50 ohms
5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations
6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
7. Analog, composite, and AES inputs.
a. AES Impedance: 100-110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
8. Stereo generator
9. Front Panel Control
10. Automatic transmitter switcher
11. RF switch
12. RF output Low Pass Filter
13. Rack cabinets
Frequency 101.7MHz
CLIN 0003: 250W FM 106.2MHz, Main/Alt configuration (AFN-E/Belgium/Kleine Brogel/AFN Benelux)
3. Power Factor: 0.90 or better
4. Output Impedance: 50 ohms
5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations
6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
7. Analog, composite, and AES inputs.
a. AES Impedance: 100-110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
8. Stereo generator
9. Front Panel Control
10. Automatic transmitter switcher
11. RF switch
12. RF output Low Pass Filter
13. Rack cabinets
Frequency 106.2MHz
CLIN 0004: 250W FM 106.5MHz, Main/Alt configuration (AFN-E/Belgium/Shape/AFN Benelux)
3. Power Factor: 0.90 or better
4. Output Impedance: 50 ohms
5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations
6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
7. Analog, composite, and AES inputs.
a. AES Impedance: 100-110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
8. Stereo generator
9. Front Panel Control
10. Automatic transmitter switcher
11. RF switch
12. RF output Low Pass Filter
13. Rack cabinets
Frequency 106.5MHz
CLIN 0005: 250W FM 107.3MHz, Main/Alt configuration (AFN-E/Greece/Souda Bay, Crete/AFN Souda Bay)
1. Two 100W - 300W FM transmitters in Main/Alternate configuration
2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
15. Low Pass Filter
16. Rack cabinets
17. Remote Control Unit that is GSM (cellular) Modem Compatible
Frequency 107.3MHz
CLIN 0006: 5000W FM 105.9MHz, Main/Alt configuration (AFN-E/Italy/Sigonella/AFN Sigonella)
1. Two 5000W FM transmitters in Main/Alternate configuration
2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
15. Low Pass Filter
16. Rack cabinets
Frequency 105.9MHz
CLIN 0007: 5000W FM 106.0MHz, Main/Alt configuration (AFN-E/Italy/Vicenza/AFN Vicenza)
1. Two 5000W FM transmitters in Main/Alternate configuration
2. AC Input Voltage: 220VAC, 50/60Hz, Three-Phase
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
15. Low Pass Filter
16. Rack cabinets
17. Remote Control Unit that is GSM (cellular) Modem Compatible
Frequency 106.0MHz
CLIN 0008: 500W FM 106.5MHz, Main/Alt configuration (AFN-E/Honduras/Soto Cano Honduras/AFN Honduras)
1. Two 500W-1KW FM Digital transmitters/exciters in Main/Alternate configuration
3. Power Factor: 0.90 or better
4. Output Impedance: 50 ohms
5. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations
6. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
7. Analog, composite, and AES inputs.
a. AES Impedance: 100-110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
8. Stereo generator
9. Front Panel Control
10. Automatic transmitter switcher
11. RF switch
12. RF output Low Pass Filter
13. Rack cabinets
Frequency 106.5MHz
CLIN 0009: 500W FM 102.1MHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)
1. Two 500W-1KW FM transmitters in Main/Alternate configuration
2. AC Input Voltage: 220VAC, 50/60Hz, Single-Phase
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
15. Low Pass Filter
16. Rack cabinets
Frequency 102.1MHz
CLIN 0010: 500W FM 103.1MHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)
1. Two 500W-1KW FM transmitters in Main/Alternate configuration
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
Frequency 103.1MHz
CLIN 0011: 1kW AM 1340KHz, Main/Alt configuration (AFN-E/Guantanamo Bay (GTMO)/AFN Guantanamo Bay)
1. Two 1KW AM transmitters in Main/Alternate configuration
3. Efficiency: 60% or better
4. Power Factor: 0.70 or better
5. Output Impedance: 50 ohms
6. Redundant Power Supplies
7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
10. Analog, composite
a. Impedance: 600 Ohm Balanced
11. Automatic transmitter switcher
12. Front Panel Metering
13. RF switch.
14. Rack cabinets
15. Remote Control Unit that is GSM (cellular) Modem Compatible
Frequency 1340KHz
CLIN 0012: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Iwakuni/AFN Iwakuni)
2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase
3. Efficiency: 60% or better
4. Power Factor: 0.70 or better
5. Output Impedance: 50 ohms
6. Redundant Power Supplies
7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
10. Analog, composite
a. Impedance: 600 Ohm Balanced
11. Automatic transmitter switcher
12. Front Panel Metering
13. RF switch.
14. Rack cabinets
Frequency 1575KHz
CLIN 0013: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Misawa/AFN Misawa)
2. AC Input Voltage: 208VAC, 50/60Hz, Single-Phase
3. Efficiency: 60% or better
4. Power Factor: 0.70 or better
5. Output Impedance: 50 ohms
6. Redundant Power Supplies
7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
10. Analog, composite
a. Impedance: 600 Ohm Balanced
11. Automatic transmitter switcher
12. Front Panel Metering
13. RF switch.
14. Rack cabinets
CLIN 0014: 1kW FM 89.1MHz, Main/Alt configuration (AFN-P/Japan/Camp Foster/AFN Okinawa)
1. Two 1KW FM transmitters in Main/Alternate configuration
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
Frequency 89.1MHz
CLIN 0015: 1kW AM 1575KHz, Main/Alt configuration (AFN-P/Japan/Sasebo/AFN Sasebo)
3. Efficiency: 60% or better
4. Power Factor: 0.70 or better
5. Output Impedance: 50 ohms
6. Redundant Power Supplies
7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
10. Analog, composite
a. Impedance: 600 Ohm Balanced
11. Automatic transmitter switcher
12. Front Panel Metering
13. RF switch.
14. Rack cabinets
CLIN 0016: 10kW AM 648KHz, Main/Alt configuration (AFN-P/Japan/Okinawa-Camp Kinzer/AFN Okinawa/)
3. Efficiency: 60% or better
4. Power Factor: 0.70 or better
5. Output Impedance: 50 ohms
6. Redundant Power Supplies
7. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
8. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
9. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
10. Analog, composite
a. Impedance: 600 Ohm Balanced
11. Automatic transmitter switcher
12. Front Panel Metering
13. RF switch.
14. Rack cabinets
Frequency 648KHz
CLIN 0017: 250W FM 99.1MHz, Main/Alt configuration (AFN-P/AFN Diego Garcia)
1. Two 100-300W FM transmitters in Main/Alternate configuration
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
14. RF switch
15. Low Pass Filter
16. Rack cabinets
Frequency 99.1MHz
CLIN 0018: 250W FM 101.9MHz, Main/Alt configuration (AFN-P/AFN Diego Garcia)
1. Two 100-300W FM transmitters in Main/Alternate configuration
3. Efficiency: 50% or better
4. Power Factor: 0.90 or better
5. Output Impedance: 50 ohms
6. RF Harmonics Suppression: Must meet all FCC/DOC requirements and CCIR recommendations.
7. Must meet all FCC, DOC, CE, and IEC 215 safety requirements
8. Must Conform to all European Community Radio and telecommunications terminal equipment standards and have all required CE Conformity Markings and Inscriptions
9. Analog, composite, and AES inputs
a. AES Impedance: 110 Ohm balanced
b. L&R Impedance: 600 Ohm or 10K Ohm selectable, Balanced
10. Stereo generator
11. IP Connectivity
12. Front Panel Control and Metering
13. Automatic transmitter switcher
Frequency 101.9MHz
CLIN 0019: Antenna Tuning Unit (AFN-P/Japan/Sasebo/AFN Sasebo)
1. Transmitter Frequency is 1575KHz
2. Transmitter Power is 1000W
3. The measured impedance is 87 +j60 ohms
4. The tower height is 45 meters self-supporting type with a triangular cross section
5. The tower Face Width is proportional with a 5.6 meters triangular section at the bottom and a 70 centimeters top triangular section.
6. The tower is shunt fed. (Folded Type Down Lead Antenna or Folded Unipole)
7. The unipole skirt kit height on the tower is 45 meters
8. The level of the lower shorting ring is 20m
9. The tower has 9 skirt wires, 22 square gauge, straight off the face centers
10. The standoff distance of the wires from the tower is 2.5m diameter at the top and 5m at the bottom
11. The shorting stub wires level is 40m L1, 20m L2 shorting ring
12. No specific existing restrictions for isolation
13. The Input Transmission line impedance is 50ohms using RG-218/U(RG-17A/U) as a transmission line
14. The connection type and size is open wire
15. The required RF current metering is a Toroidal style out RF current meter
16. The current transmission line length from transmitter output to ATU input is ~60m
17. There is a need to use the existing mounting steel plate (400mmx400mmx4.5mm) and cable feed.
CLIN 0020: Antenna Tuning Unit (AFN-P/Korea/Camp Carroll/AFN Daegu)
1. Transmitter Frequency: 1440 KHz
2. Transmitter Power: 5000W
3. The measured impedance: Not at This Time
4. The tower height is 180 ft. guyed tower type with a triangular cross section
5. The tower Face Width is 18 inches
6. The tower is Series Fed Base Isolated.
7. Restrictions for isolation: See below picture
8. The Input Transmission line impedance is 50 ohms nominal.
9. The connection type and size is 1 7/8 inch.
10. The required RF current metering is a Toroidal style out RF current meter
11. The current transmission line length from transmitter output to ATU input is ~100 ft.
12. The dimensions are 52”L x 34” W x 42” H It has 34.5” legs and sits on a concrete base of 68” x 44”