CED 1E10: SAFE LARGE

SAFE, LARGE

9 Generalized Operating Specifications:

9.1 Dimensions:

9.1.1 41 inches long / wide, 32 inches deep, 78 inches high (exterior dimensions).

9.1.2 Dimensional sizes, such as length, depth, and height are not critical to this equipment so long as minimum cubic foot and minimum stacked drawer requirements are met. Safe must fit through a standard doorway with a

34.5 inch opening when fully assembled.

9.2 Construction:

9.2.1 Commercial off the shelf (COTS) standard unit, no unique DeCA requirements.

9.3 Operating Characteristics that shall be provided:

9.3.1 Minimum 29 cubic feet capacity.

9.3.2 Welded ball bearing hinges with adjustment screws.

9.3.3 Underwriters Laboratory (UL) approved Group 1R anti-manipulative lock.

9.3.4 Equipped with a spy-proof dial.

9.3.5 UL approved locking and re-locking devices.

9.3.6 Equipped with full-length dead bar or equivalent technology to prevent entry into the safe by removing the hinges.

9.3.7 Door hinged (LH / RH) as specified on an individual basis.

9.3.8 5 heavy-duty adjustable shelves.

9.3.9 Shelves shall accommodate up to 50 stacked cash register drawers with nominal dimensions of 14.5 inches wide, 13.5 inches deep, 2 inches high.

9.3.10 Accommodates a standard internal alarm system.

10 Operating Options: (MARK ONE)(Commissary)

10.1 _____ Right hand hinged door

10.2 _____ Left hand hinged door

11 Color Requirements: Beige or neutral colors

12 Maintenance Requirements: Continued parts support for equipment is required for the projected total life cycle of the equipment plus 5 years.

13 Industry Standards and Contractor Requirements:

13.1 Industry Standards: Underwriters Laboratory (UL) listed or equivalent minimum

Tool Resistant (TL) rating of TL-30. Class-350 fire rating.

13.2 Contractor Requirements:

13.2.1 Must be shipped ready to use.

13.2.2 No additional work shall be required on the part of the government.

14 Special / Specific Equipment Safety Requirements: N / A

15 Information To Be Provided By The Contractor To The Commissary At Time of

Delivery:

15.1 Commercial Warranty and Point of Contact for Warranty Service.

15.2 Installation and Operating Instructions.

15.3 Parts List.

16 Federal Supply Class: 7110

17 Special Considerations For Installation/De-installation Of Equipment:

(NOTICE/WARNING)

17.1 Contractor:

17.1.1 New safe installation: Ground floor delivery, setup and bolt down.

17.1.2 Old safe removal: Unbolt existing safe and remove from premises.

17.2 Store: Door measurements must be verified to ensure the safe will fit through the door opening.