IQO INQUIRY
FM: PL8211
TO: Contractors
DATE (MM/DD/YYYY): 6/7/2018
SUBJECT: HC101318QB031-0001 Amend: 0001
A. TYPE ACTION: ADMIN AMEND
1. PURPOSE: *** The purpose of amend 0001 is to update the proposal due date, the service date and to add the following reaward language.
THIS IS A REAWARD OF A CURRENT SERVICE, (CSA: CTLL 000060EBM ). IF THE
INCUMBENT QUOTE IS EVALUATED AS THE LOWEST PRICE TECHNICABLLY ACCEPTABLE,
THE CURRENT CSA WILL BE ADMINISTRATIVELY DISCONTINUED WITHIN 30 DAYS OF
INCUMBENT CONTRACTOR RECEIVING AWARD. INCUMBENT CONTRACTORS SHALL
SUBMIT NOTICE OF COMPLETION (NOC) WITHIN 30 DAYS.
All else remains unchanged.***
1. A. SUMBIT QUOTE TO PROVIDE, INSTALL AND MAINTAIN A 10GB WAVE SERVICE
BETWEEN BLDG 1645,
ROOM 10 (SWITCH ROOM), 1645 RANDOLPH ROAD, FORT SILL, OK., AND BLDG 200,
COMPUTER ROOM #2, 3326
GENERAL HUDNELL DRIVE, SAN ANTONIO, TX.
-CONTRACTORS SHALL MEET RTD OF 10 MILLISECONDS. SEE UNIQUE INSTALL FACTORS.
VENDORS MUST CLEARLY STATE IN QUOTES THEIR COMPLIANCE WITH GOVERNMENT
TESTING AND ACCEPTANCE REQUIREMENTS
2. ESTABLISH TSP.
3. THIS REQUIREMENT MUST BE WORKED IN CONJUNCTION WITH SOLICITATION
HC101318QB030 /TSR SG13APR185824 AND MUST BE ENGINEERED AND PROVISIONED
TOTALLY DIVERSE END TO END FROM THE GOVERNMENT SERVICE DELIVERY POINTS
(SDP) FROM TSR SG13APR185824; MEANING THE PHYSICAL PATHS ARE TOTALLY
SEPARATE INCLUDING MAN HOLES, CONDUIT, CENTRAL OFFICE LOCATIONS, AND FIBER
BUILDS. ADDITIONALLY AS A MINIMUM MUST HAVE 50 METERS PHYSICAL SEPARATION
FROM TSR SG13APR185824.
4. EACH CONTRACTOR IS RESPONSIBLE FOR READING AND COMPLYING WITH ALL
TECHNICAL ASPECTS OF THIS SOLICITATION, TO INCLUDE READING AND AGREEING
WITH THE STANDARD PROVISIONS, ATTACHMENTS LISTING SPECIFIC TECHNICAL
REQUIREMENTS, PRICE QUOTE REQUIREMENTS, AND REQUESTED SERVICE DATE.
FAILURE TO READ AND ADHERE TO ANY PORTION OF THE INQUIRY SHALL RENDER THE
HC101318QB031-0001
QUOTE NON-COMPLIANT AND RESULT IN IT BEING EXCLUDED FROM EVALUATION AND
AWARD.
5. THE SERVICE DATE TO BE MET IS: 26 NOV 18 (SIP). THE GOVERNMENT ASSUMES
THAT CONTRACTORS HAVE CONSIDERED ALL ISSUES THAT MAY IMPACT THE SERVICE
DATE. THE GOVERNMENT MAY CANCEL, TERMINATE, OR REQUEST CONSIDERATION
IAW STANDARD PROVISION 42 FOR FAILURE TO MEET CONTRACTUAL SERVICE DATE OR
COMPLY WITH ANY CONTRACT TERMS OR CONDITIONS.
6. CONTRACTORS SHALL SUBMIT QUOTES IAW STANDARD PROVISION 04.
QUOTES SHALL INCLUDE SUFFICIENT DETAIL FOR EFFECTIVE EVALUATION AND SHOULD
NOT SIMPLY REPHRASE OR RESTATE THE GOVERNMENT REQUIREMENTS. RATHER,
THEY MUST PROVIDE CONVINCING RATIONALE TO ADDRESS HOW THE CONTRACTOR
INTENDS TO MEET THE REQUIREMENT. IN RESPONSE TO THIS SOLICITATION, NO
TERMS OR CONDITIONS PLACED UPON THE GOVERNMENT, NOR ASSUMPTIONS WILL BE
ACCEPTED. CONTRACTORS ARE ENCOURAGED TO SUBMIT QUESTIONS AND REQUEST
CLARIFICATIONS OF THE REQUIREMENT (S) BEFORE SUBMITTING QUOTES. QUESTIONS
SHALL BE SUBMITTED TO CONTRACT SPECIALIST AND CONTRACTING OFFICER DURING
THE SOLICITATION PHASE ONLY, AND RESPONSES FOR ALL INTERESTED PARTIES WILL BE
POSTED TO FEDBIZOPPS. QUOTES MUST BE UPLOADED TO IDEAS.
7. CONTRACTOR SHALL PROVIDE COLOR POWERPOINT DRAWINGS SHOWING THE ROUTES
FROM THE COMMERCIAL DEMARKS TO THE SUPPORTING CENTRAL OFFICES AND/OR
WIRING CENTERS, ENSURING THE PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE
BEING MET. DRAWINGS MUST INCLUDE SEPARATION DISTANCES, TOTAL FIBER MILES
AND ROUND TRIP DELAY BASED ON ACTUAL DISTANCE IN MILES. REFER TO STANDARD
PROVISION 39 FOR SPECIFIC DOCUMENTATION REQUIREMENTS. SAMPLE DRAWINGS ARE
INCLUDED THE ATTACHMENTS.
8. WAVE SERVICE TESTING MUST BE COORDINATED WITH CUSTOMER ACCEPTANCE
AUTHORITY AT BOTH LOCATIONS BEFORE NOTICE OF COMPLETION IS SUBMITTED
TO DITCO. FOR DISA WAVE REQUIREMENTS THE ACCEPTING AUTHORITY IS:MICHAEL
REEVES, MICHAEL.B.REEVES.CTR@MAIL.MIL (618) 220-8973 OR CLARENCE
MOORE, CLARENCE.S.MOORE.CTR@MAIL.MIL, (618) 220-9935 DISA CONUS/
D312-770-8691,C618-220-8691
9. COMPLETION REPORT: SERVICE WILL BE ACCEPTED ON BEHALF OF THE U.S.
GOVERNMENT BY DISA CONUS/D770-8691,C618-220-8691 WHO WILL SUBMIT A COMPLETION
REPORT IAW DISAC 310-130-1, CHAP 2 OF DISAC 310-70-1, CHAP 8. REPORT WILL BE
ADDRESSED TO THE ORGINATOR AND ALL ADDRESSEES OF THIS TSO. IMPLEMENTATION
ASSISTANCE: FOR DISN CORE CIRCUIT ACTIVATION ASSISTANCE OR SERVICE
IMPLEMENTATION INQUIRIES/SCHEDULING, CONTACT DISA CONUS DISN CORE
IMPLEMENTATION TEAM AT DSN 312-770-8751; COML 618-220-8751.. SINGLE MODE FIBER
MUST BE ENGINEERED/PROVISIONED IN SUCH A WAY THAT THE GOVERNMENT CAN
CHANGE/REVISE CHANNELIZATION WITHOUT TELECOMM PROVIDER INTERVENTION. A.
NOTE 1 (JITTER).: IN A STEADY-STATE CONDITION, THE PATTERN OF SYNCHRONOUS
TRANSPORT SIGNAL (STS) POINTER ADJUSTMENTS, SDN TO SDN (END-TO-END THROUGH
THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE NO MORE STRESSFUL (I.E.,
CREATE MORE JITTER THROUGH THE DESYNCHRONIZER AS DESCRIBED IN TABLE 6 OF
ANSI T1.105.03-1994) THAN THE POINTER ADJUSTMENT SEQUENCE IN FIGURE 5 OF ANSI
T1.105.03-1994. DURING TRANSIENT EVENTS (WHICH SHALL OCCUR NO MORE THAN 2
TIMES PER DAY), THE PATTERN OF STS POINTER ADJUSTMENTS, SDN TO SDN (END-
TO-END THROUGH THE SERVICE PROVIDED NETWORK OUTPUTS), SHALL BE FOUR OR
LESS PER HOUR. ADDITIONALLY, THE MAXIMUM TIME INTERVAL ERROR (MTIE) OVER A
PERIOD OF S SECONDS, OR WANDER, SHALL NOT EXCEED (.01S + 10000) NANOSECONDS
FOR VALUES OF S GREATER THAN 10,000. B. WAVELENGTH TRANSMISSION SERVICES:
WAVELENGTH TRANSMISSION SERVICES FOR RATES OF 10GBPS SHALL BE IN
ACCORDANCE WITH ITU-T RECOMMENDATIONS G.709(03/2003), G.707(12/03), G.957(03/06), G.692(10/98) & TELCORDIA GR253-IE4. THE PROVIDED WAVELENGTH TRANSMISSION
SERVICE SHALL NOT INHIBIT GOVERNMENT OPERATION OFUNDERLYING PROTOCOLS
AND TRANSPORT SYSTEMS SUCH AS, BUT NOT LIMITED TO, SONET/SDH, IP, ATM,
GIGABIT ETHERNET, AND ENCRYPTION. THE WAVELENGTH TRANSMISSION SERVICE
PROVIDED SHALL PASS ALL PAYLOAD, PATH AND LINE OVERHEAD BYTETRANSPARENTLY
(UNTOUCHED/UNALTERED) AND WITHOUT MONITORING SDP TO SDP. THERE SHALL NOT
BE ANY LINE TERMINATING EQUIPMENT (LTE) BETWEEN SDP AND SDP.
ONCE TELECOMM PROVIDER HAS COMPLETED INSIDE WIRING FROM THE DWDM
EQUIPMENT SUITE TO THE GOVERNMENT SERVICE DELIVERY POINT (SDP) AT EACH
LOCATION, THEY MUST ENSURE THE LIGHT LEVEL READINGS (DB LOSS) ARE ADJUSTED
TO READ -3 TO -9 LOSS. ADDITIONALLY, THESE LEVELS MUST BE DOCUMENTED ON THE
NOTICE OF COMPLETION (NOC) SENT TO DITCO 2. CIRCUIT REQUIRES THE FOLLOWING
PARAMETERS: (A) FIBER TERMINATION: SINGLE-MODE INTERFACE REQUIREMENT/
INTERFACE DATA RATE: LINE CODING, FRAME FORMAT, PHYSICAL CONNECTOR, 10 GBPS,
NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL OPTIONS DEFINED SC CONNECTOR,
SINGLE-MODE FIBER PER ANSI T1.105.06-2002 (SR-0, SR-1, IR-1, IR-2, LR-1, LR-2, LR-3).
M. ADDITIONAL INFORMATION:
3. TSR NUMBER: SG13APR185825
4. CCSD: 69F5
Z. DITCO CONTACT:
Gabriel Zuccarelli gabriel.f.zuccarelli.civ@mail.mil
Angelina Hutson
DITCO Contracting Officer
Unless otherwise specified, all other terms and conditions are unchanged.
Paragraph E.SERVICE DATE change from:
Nov 19, 2018
To:
Nov 26, 2018
Paragraph V.QUOTE DUE DATE AND TIME change from:
Jun 13, 2018 12:30:00 PM CDT
To:
Jun 20, 2018 12:30:00 PM CDT