Garmatz_Electrcial_Upgrades_-_100__submission-Drawings.pdf
PDF 34 MB Posted
- Attached to
- Construction Services for Garmatz Electrical System Renovations Federal contract opportunity
- Solicitation number
- GS-03-P-15-DX-C-7002
About this file
Garmatz Electrical Upgrade 100 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_Seven_Package.pdf | ||
| Amendment_Six_Package.pdf | ||
| Amendment_Five_Package.pdf | ||
| Amendment_Four_Package.pdf | ||
| Amendment_Three_Package.pdf | ||
| Amendment_Two_Package.pdf | ||
| Amendment_One_9.4.2015.pdf | ||
| C201-SB_Garmatz_Electrical_REV8.28.15.pdf | ||
| Solicitation_Package.pdf | ||
| Garmatz_Electrcial_Upgrades_-_100__submission-Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECT MECHANICAL & ELECTRICAL ENGINEER
Garmatz - Electrical Systems Upgrade
Edward A. Garmatz Federal Courthouse
Baltimore, MD
Final Submission
July 30, 2015
GSA Mid Atlantic 20th North 8th St. Philadelphia, PA 19107
OKKS Studios, Inc.
2 Wisconsin Circle / Suite 820
Chevy Chase, Md. 20815-7003
Tel: (301) 718-0080
Fax: (301) 718-9520
Henry Adams, LLC, Consulting Engineers 600 Baltimore Avenue 4th Floor
Baltimore, MD 21204-4079
Tel: (410)296-6500
Fax: (410)296-3156
GENERAL
G-001 COVER SHEET
G-002 LEGEND, ABBREVIATIONS, NOTES
ARCHITECTURAL
AD-101 DEMOLITION PLANS
AD-102 DEMOLITION PLANS
A-101 NEW WORK PLANS
A-102 NEW WORK PLANS
A-500 DETAILS
HAZARDOUS MATERIALS
H-101 ASBESTOS MAINTENANCE PLAN
ELECTRICAL
E-001 ELECTRICAL LEGEND, CONV., NOTES, AND ABBREV.
E-002 ELECTRICAL PROJECT NOTES
ED101 LOWER PARKING LEVEL - ELECTRICAL - DEMOLITION
ED102 PARKING LEVEL - ELECTRICAL - DEMOLITION
ED103 FIRST FLOOR - ELECTRICAL - DEMOLITION
ED104 SECOND FLOOR - ELECTRICAL - DEMOLITION
ED105 THIRD FLOOR - ELECTRICAL - DEMOLITION
ED106 FOURTH FLOOR - ELECTRICAL - DEMOLITION
ED107 FIFTH FLOOR - ELECTRICAL - DEMOLITION
ED108 SIXTH FLOOR - ELECTRICAL - DEMOLITION
ED109 SEVENTH FLOOR - ELECTRICAL - DEMOLITION
ED110 EIGHTH FLOOR - ELECTRICAL - DEMOLITION
ED111 NINTH FLOOR - ELECTRICAL - DEMOLITION
ED112 PENTHOUSE LEVEL - ELECTRICAL - DEMOLITION
ED401 LOWER PARKING LEVEL ENLARGED PART PLAN - ELEC - DEMO
ED402 PARKING LEVEL ENLARGED PART PLAN - ELEC - DEMO
EP101 LOWER PARKING LEVEL - ELECTRICAL - NEW WORK
EP102 PARKING LEVEL - ELECTRICAL - NEW WORK
EP103 FIRST FLOOR - ELECTRICAL - NEW WORK
EP104 SECOND FLOOR - ELECTRICAL - NEW WORK
EP105 THIRD FLOOR - ELECTRICAL - NEW WORK
EP106 FOURTH FLOOR - ELECTRICAL - NEW WORK
EP107 FIFTH FLOOR - ELECTRICAL - NEW WORK
EP108 SIXTH FLOOR - ELECTRICAL - NEW WORK
EP109 SEVENTH FLOOR - ELECTRICAL - NEW WORK
EP110 EIGHTH FLOOR - ELECTRICAL - NEW WORK
EP111 NINTH FLOOR - ELECTRICAL - NEW WORK
EP112 PENTHOUSE LEVEL - ELECTRICAL - NEW WORK
EP401 LOWER PARKING LEVEL ENLARGED PLAN - ELEC - NEW WORK
EP402 PARKING LEVEL ENLARGED PART PLAN - ELECTRICAL - NEW WORK
EP403 LOW VOLTAGE SWITCHGEAR CONDUIT ENTRY DETAILS
E-201 ELEVATIONS OF MEDIUM VOLTAGE SWITCHGEAR
E-501 ELECTRICAL DETAILS
E-601 ELEC SERVICE ENTRANCE EQUIPMENT ONE-LINE - DEMOLITION
E-602 ELEC SERVICE ENTRANCE EQUIPMENT ONE-LINE - NEW WORK
E-603 ELEC SERVICE ENTRANCE EQUIPMENT ONE-LINE - NEW WORK
E-604 POWER MONITORING AND CONTROL RISER - NEW WORK
E-605 PARTIAL NORTH RISER ELEC ONE-LINE DIAGRAM - DEMO
E-606 PARTIAL NORTH RISER ELEC ONE-LINE DIAGRAM - DEMO
E-607 PARTIAL WEST RISER ELEC ONE-LINE DIAGRAM - DEMO
E-608 PARTIAL WEST RISER ELEC ONE-LINE DIAGRAM - DEMO
E-609 PARTIAL EAST RISER ELEC ONE-LINE DIAGRAM - DEMO
E-610 PARTIAL EAST RISER ELEC ONE-LINE DIAGRAM - DEMO
E-611 PARTIAL NORTH RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-612 PARTIAL NORTH RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-613 PARTIAL WEST RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-614 PARTIAL WEST RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-615 PARTIAL EAST RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-616 PARTIAL EAST RISER ELEC ONE-LINE DIAGRAM - NEW WORK
E-701 LV SWITCHGEAR SCHEDULE AND ELEVATION - DEMOLITION
E-702 LV SWITCHGEAR SCHEDULE AND ELEVATION - NEW WORK
E-703 MCC PANEL SCHEDULES - LOWER PARKING LEVEL BASEMENT
E-704 MCC PANEL SCHEDULES - LOWER PARKING LEVEL BASEMENT
E-705 MCC PANEL SCHEDULES - PENTHOUSE
E-706 MCC PANEL SCHEDULES - PENTHOUSE
E-707 PANEL SCHEDULES - LP LEVEL WEST
E-708 PANEL SCHEDULES - LP LEVEL WEST
E-709 PANEL SCHEDULES - LP LEVEL WEST
E-710 PANEL SCHEDULES - P LEVEL NORTH
E-711 PANEL SCHEDULES - P LEVEL NORTH
E-712 PANEL SCHEDULES - P LEVEL NORTH
ELECTRICAL (CONT.)
E-713 PANEL SCHEDULES - P LEVEL EAST
E-714 PANEL SCHEDULES - FIRST FLOOR NORTH
E-715 PANEL SCHEDULES - FIRST FLOOR NORTH
E-716 PANEL SCHEDULES - FIRST FLOOR KITCHEN
E-717 PANEL SCHEDULES - FIRST FLOOR WEST
E-718 PANEL SCHEDULES - FIRST FLOOR EAST A
E-719 PANEL SCHEDULES - FIRST FLOOR EAST
E-720 PANEL SCHEDULES - FIRST FLOOR EAST
E-721 PANEL SCHEDULES- SECOND FLOOR NORTH
E-722 PANEL SCHEDULES- SECOND FLOOR NORTH
E-723 PANEL SCHEDULES - SECOND FLOOR WEST AND AV CLOSET
E-724 PANEL SCHEDULES - SECOND FLOOR EAST CLOSET
E-725 PANEL SCHEDULES - SECOND FLOOR EAST CLOSET
E-726 PANEL SCHEDULES - THIRD FLOOR NORTH
E-727 PANEL SCHEDULES - THIRD FLOOR NORTH
E-728 PANEL SCHEDULES - THIRD FLOOR WEST
E-729 PANEL SCHEDULES - THIRD FLOOR WEST
E-730 PANEL SCHEDULES - THIRD FLOOR EAST
E-731 PANEL SCHEDULES - THIRD FLOOR EAST
E-732 PANEL SCHEDULES - FOURTH FLOOR NORTH
E-733 PANEL SCHEDULES - FOURTH FLOOR NORTH
E-734 PANEL SCHEDULES - FOURTH FLOOR WEST
E-735 PANEL SCHEDULES - FOURTH FLOOR WEST
E-736 PANEL SCHEDULES - FOURTH FLOOR EAST
E-737 PANEL SCHEDULES - FOURTH FLOOR EAST
E-738 PANEL SCHEDULES - FIFTH FLOOR NORTH
E-739 PANEL SCHEDULES - FIFTH FLOOR NORTH
E-740 PANEL SCHEDULES - FIFTH FLOOR WEST
E-741 PANEL SCHEDULES - FIFTH FLOOR WEST
E-742 PANEL SCHEDULES - FIFTH FLOOR EAST
E-743 PANEL SCHEDULES - FIFTH FLOOR EAST
E-744 PANEL SCHEDULES - SIXTH FLOOR NORTH
E-745 PANEL SCHEDULES - SIXTH FLOOR NORTH
E-746 PANEL SCHEDULES - SIXTH FLOOR WEST
E-747 PANEL SCHEDULES - SIXTH FLOOR WEST
E-748 PANEL SCHEDULES - SIXTH FL WEST CRT RMS AND COMM CTR
E-749 PANEL SCHEDULES - SIXTH FLOOR EAST
E-750 PANEL SCHEDULES - SIXTH FLOOR EAST
E-751 PANEL SCHEDULES - SIXTH FLOOR EAST COURTROOMS
E-752 PANEL SCHEDULES - SEVENTH FLOOR NORTH
E-753 PANEL SCHEDULES - SEVENTH FLOOR NORTH
E-754 PANEL SCHEDULES - SEVENTH FLOOR WEST
E-755 PANEL SCHEDULES - SEVENTH FLOOR WEST
E-756 PANEL SCHEDULES - SEVENTH FLOOR EAST
E-757 PANEL SCHEDULES - SEVENTH FLOOR EAST
E-758 PANEL SCHEDULES - EIGHTH FL NORTH AND COMPUTER RM
E-759 PANEL SCHEDULES - EIGHTH FLOOR NORTH
E-760 PANEL SCHEDULES - EIGHTH FLOOR WEST
E-761 PANEL SCHEDULES - EIGHTH FLOOR WEST
E-762 PANEL SCHEDULES - EIGHTH FLOOR EAST
E-763 PANEL SCHEDULES - EIGHTH FLOOR EAST
E-764 PANEL SCHEDULES - NINTH FLOOR NORTH
E-765 PANEL SCHEDULES - NINTH FLOOR NORTH
E-766 PANEL SCHEDULES - NINTH FLOOR WEST
E-767 PANEL SCHEDULES - NINTH FLOOR WEST
E-768 PANEL SCHEDULES - NINTH FLOOR EAST
E-769 PANEL SCHEDULES - NINTH FLOOR EAST
E-770 PANEL SCHEDULES - PENTHOUSE NORTH
E-771 PANEL SCHEDULES - PENTHOUSE NORTH GENERATOR ROOM
E-772 PANEL SCHEDULES - PENTHOUSE WEST
E-773 PANEL SCHEDULES - PENTHOUSE EAST
INDEX OF DRAWINGSVICINITY MAP LOCATION MAP
BUILDING LOCATION
A1
A1
A1
A1
LEGEND & SYMBOLS
EXISTING CONST.
TO REMAIN
EXISTING CONST. TO
BE REMOVED
NEW CONST.
PARTITION TYPE
ELEVATION
INDICATION
DETAIL
INDICATION
SECTION
INDICATION
CONCRETE
MASONRY UNITS
SOLID CMUBRICK
CONCRETE
GYPSUM BOARD,
PLASTER OR GROUT
BATT INSULATION
FINISHED LUMBER
STEEL
ALUMINUM
PLYWOOD
RIGID INSULATION
DISCONTINUOUS
WOOD BLOCKING
CONTINUOUS WOOD
BLOCKING
QUADRAPLEX OUTLET
DUPLEX OUTLET
TELEPHONE OUTLET
EXIT LIGHT
DOWNLIGHT
CEILING GRILLE
KEYNOTE
J JUNCTION BOX
3 1
# # DOOR NUMBER
FLUORESCENT FIXTURES
EXISTING
CONSTRUCTION
ABBREVIATIONS
CARPETCPT
EQ EQUAL
EXISTING
EXISTING TO REMAIN
FIRE EXTINGUISHER CABINET
EQUIPMENT
EXIST
FEC
FT
ETR
EQUIP
FOOT
DIMENSION
DRAWING
DRAWER
ELEVATOR OR ELEVATION
CERAMIC TILE
DETAIL
ELECTRIC
ELECTRICAL OUTLET
DWR
DWG
ELEV
E
ELEC
DIM
DR
CT
DTL
DOOR
SOLID CORE WOOD
STAINLESS STEEL
VINYL COMPOSITION TILE
VINYL WALL COVERING
SEAMLESS SHEET VINYL
FLUORESCENTFLOR
SCW
NIC NOT IN CONTRACT
PAINT
PLUMBING
PLASTIC
REQUIRED
RESILIENT
PLYWOOD
ROOM
ON CENTER
RESILIENT BASE
REFRIGERATOR
OPENING
PAIR
RADIUS
SWITCH
PARTICLE, PARTITION
MAXIMUMMAX
RB
MASONRY OPENINGMO
MET
MIN
MECH
MINIMUM
METAL
MECHANICAL
RM
S
REQD
RESIL
REF
FIRE VALVE CABINET
GYPSUM BOARD
HOLLOW METAL
GENERAL CONTRACTOR
INSUL
LOCK
LAM
HDW
HM
HORIZ
INSULATION
LOCKERS
LAMINATE
HARDWARE
HORIZONTAL
GA
GC
GYP BD
GALV
FVC
FR
GAUGE
GALVANIZED
FRAME
PNT
RAD
PR
PLUMB
PLYWD
OC
OPNG
PART
P
VIF VERIFY IN FIELD
WOOD
WALL BORDER
WITH
WD
WB
W/
VWC
TELEPHONE
VERTICAL
TOILET
TYPICAL
VERT
VCT
T
TOIL
TYP
STEEL
STORAGE
SHEET VINYL
SIMILAR
SSV
STOR
STL
SV
SS
SIM
FD FLOOR DRAIN
ACP
CMU
CONT
CORR
COL
CONC
COM
CH
CLO
CLG
CAB
BLKG
CG
AFF
ALUM
BD
ADJ
ACT
CLOSET
CEILING
BOARD
AT
ACOUSTICAL CEILING PANEL
CONCRETE MASONRY UNIT
ACOUSTICAL CEILING TILE
CONTINUOUS
CORRIDOR
COLUMN
CONCRETE
COMPUTER
CORNER GUARD
CHANNEL
CABINET
BLOCKING
ABOVE FINISH FLOOR
ADJACENT, ADJUSTABLE
ALUMINUM
To best of our knowledge these drawings comply with:
1. The International Building Code, 2009 Edition, published by the International Code Council.
2. The Life Safety Code (NFPA 101) 2009 Edition
3. The Occupational Safety and Health Regulations for Construction; 29 CFR, Parts 1926 and 1910.
4. Environmental Protection Agency Regulations.
5. Applicable local codes and regulations.
6. NFPA Fire Codes, Latest editions
CODE CONFORMANCE CERTIFICATION
EXISTING BUILDING
ZONED
USE GROUP / MIXED USE (IBC)
TYPE OF CONSTRUCTION (IBC)
HIGH RISE? (Y/N)
COVERED MALL? (Y/N)
AUTOMATIC SPRINKLERS
FLOOR AREA (SF)
B
UNKNOWN
YES
NO
YES
- SQ FT
BUILDING CODE ANALYSIS
RENOVATION
B
Type IB
YES
NO
YES
-SQ FT
FIRE EXTINGUISHERFE
WALL COVERINGWC
SUSPECT HAZARDOUS MATERIAL NOTE:
ASBESTOS MATERIALS (ASM'S) AND LEAD BASED PAINT (LBP). ARE ANTICIPATED TO BE FOUND IN THE PROJECT AREA.
1. REFER TO
IF SUSPECT ACM'S OR LBP'S ARE ENCOUNTERED, DEMOLITION ACTIVITIES SHALL CEASE AND BULK ASBESTOS AND/OR LEAD PAINT CHIP
SAMPLING SHALL BE CONDUCTED. IF MATERIALS SAMPLED ARE DETERMINED NECESSARY FOR REMOVAL, UNDER SPECIFICATIONS 015950
AND 017320, THEN THE CONTRACTOR SHALL ADHERE TO THE SPECIFICATION AND THE REQUIREMENTS OF SPECIFICATION FOR ASBESTOS
REMOVAL AND FOR REMOVAL AND DISPOSAL OF LEAD-BASED PAINT.
PCBS MAY BE CONTAINED IN TRANSFORMERS, CAPACITORS, VOLTAGE REGULATORS, OIL SWITCHES, MECHANICAL INSULATION AND OTHER
MATERIALS.
PLASTIC LAMINATEPL
INTEG INTEGRAL
INTER INTERIOR
HAZARDOUS MATERIALS CONSULTANT
Apex Companies, LLC 15850 Crabbs Branch Way, Suite 200 Baltimore Avenue 4th Floor
Rockville, MD 20855
Tel: (301)417-0200
Fax: (301)975-0169
SCALE: 1/8" = 1'-0"
DEMOLITION PLAN - LOWER PARKING LEVEL
SCALE: 1/8" = 1'-0"
DEMOLITION PLAN - PARKING LEVEL
4'-0" 8'-0"0 16'-0"
20'
20'
20'
25'
25'
20'
35'
8'-2"
9'-9
1311 12 14
ELEC.
UP
DN
DN
DN
3 4 5 6 7 8 9 10
UPDN
FEC
CORR.
MAG.
LIBRARY
PROJ.
BOOTH
HOLD.
CELL
T.
OFFICE
RECEPTION/
SECRETARY
CL.
CORRIDOR
MAGISTRATE
COURTROOM 2D
GISTRATE
TROOM 2E
WAIT./
RECEPT.
L.
NESS
ELEVATOR
LOBBY
TEL.
ELECT.
MEN'S
WOMEN'S
JAN.
SERVICE
CLERK
STORAGE
STAFF T.
STOR.
CONFERENCE
COURTROO
VESTIBULE
CONFERENCE LIBRARY
P.
20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"
35'
20'
25'
25'
20'
20'
20'
20'
D N
U P
D N
U P
D N
U P
U P
UPUP
UP
RIDOR
AFETERIA/
KITCHEN
MARSHAL'S
SUPPL.
CLERKS'
AREA
RECEPTION
ALCOVE
MARSHAL'S
STATION
COURTROOM
LOBBY
VEST.
VEST.
ELEVATOR
LOBBY
MAIN
ELEC.
SUPPLIES
CEREMONIAL
JURY ROOM
ATTORNEY/
CONF.
COURTROOM 1A
MUL
ROBING ROOM
COURT ROOM
VESTIBULESOUND
LOCK
20' 20' 20' 20' 20' 20' 20' 20' 20' 20'
VEST.
P
20'
A.4
A
B
C
B.6
F
D
E
G
H
1 2
U P
D N
U P
U
20'20'20'20'20'20'20'20'20'20'20'
SUPL.
DISTRICT
COURTROOM 3B
0FFICE
SUPPORT
LIBRARY
SCTY
PANTRY
COURTROOM 3C
SUPL.HOLD.
JURY
COURTROOM 3D
R E
C E
P T
IO
N
C L
ELEVATOR
LOBBY
COURT
ORRIDOR
LOBBY
COURT
LOBBY
RECEPTION
DESK
CORR
SCALE: 3/32" = 1'-0"
DEMOLITION PLAN - FIRST FLOOR
SCALE: 3/32" = 1'-0"
DEMOLITION PLAN - SECOND FLOOR
SCALE: 3/32" = 1'-0"
DEMOLITION PLAN - THIRD FLOOR (4TH - 9TH FLOORS SIMILAR)
NEW WORK PLAN - LOWER PARKING LEVEL
SCALE: 1/8" = 1'-0"
NEW WORK PLAN - PARKING LEVEL
SCALE: 1/8" = 1'-0"
4'-0" 8'-0"0 16'-0"
SCALE: 1/8" = 1'-0"
NEW WORK PLAN - LOWER PARKING LEVEL - PARTITION FIRE RESISTANCE RATING
NEW WORK PLAN - PARKING LEVEL- PARTITION FIRE RESISTANCE RATING
20'
20'
25'
25'
20'
35'
1311 12 14
ELEC.
UP
DN
DN
DN
3 4 5 6 7 8 9 10
FEC
MAG.
LIBRARY
PROJ.
BOOTH
RECEPTION/
SECRETARY
MAGISTRATE
COURTROOM 2D
GISTRATE
TROOM 2E
WAIT./
RECEPT.
L.
NESS
ELEVATOR
CLERK
STORAGE
STAFF T.
COURTROO
VESTIBULE
CONFERENCE LIBRARY
20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"
35'
20'
25'
25'
20'
20'
20'
20'
D N
U P
D N
U P
D N
U P
UPUP
RIDOR
AFETERIA/
KITCHEN
MARSHAL'S
SUPPL.
CLERKS'
AREA
ALCOVE
MARSHAL'S
STATION
COURTROOM
LOBBY
VEST.
VEST.
ELEVATOR
LOBBY
MAIN
JURY ROOM
ATTORNEY/
CONF.
COURTROOM 1A
MUL
ROBING ROOM
COURT ROOM
VESTIBULESOUND
LOCK
20' 20' 20' 20' 20' 20' 20' 20' 20' 20'
P
20'
A.4
A
B
C
B.6
F
D
E
G
H
U P
D N
U P
U
20'20'20'20'20'20'20'20'20'20'20'
COURTROOM 3B
0FFICE
COURTROOM 3C
SUPL.HOLD.
COURTROOM 3D
R E
C E
P T
IO
N
C L
ELEVATOR
LOBBY
LOBBY
COURT
LOBBY
RECEPTION
DESK
SCALE: 3/32" = 1'-0"
NEW WORK PLAN - FIRST FLOOR
SCALE: 3/32" = 1'-0"
NEW WORK PLAN - SECOND FLOOR
SCALE: 3/32" = 1'-0"
NEW WORK PLAN - THIRD FLOOR (4TH - 9TH FLOORS SIMILAR)
B
A-501
A-501
A
A-501
A-501
A
4" CONCRETE MASONRY
UNIT
"1
HOLLOW METAL FRAME
SEALANT, TYP.
GROUT
"1
CONCRETE MASONRY UNIT,
TYP.
SEALANT, TYP.
HOLLOW METAL FRAME
MTL. ANCHOR, MIN. 3 PER
JAMB
GROUT
STEEL ANGLE LINTELS
MATCH EXISTING
MATCH EXISTING
CONCRETE MASONRY UNIT
EXISTING CONCRETE
MASONRY UNITS ABOVE
DOOR SCHEDULE
HM - HOLLOW METAL
2 - --- PNT -
3 - -
HMA -
ETR --
PNT
A HM 4/A501
4/A501
5/A501
5/A501
HW-2
HW-1
ETR *
ETR *
ETR
* REMOVE AND REINSTALL EXISTING
* REMOVE AND REINSTALL EXISTING
PNT - PAINT
PNT
PNT
8 - - -- --- -- - - -ETR --
5 - - -- --- -- - - -ETR * * REMOVE AND REINSTALL EXISTING-
6 - - -- --- -- - - -ETR * * REMOVE AND REINSTALL EXISTING-
7 - - -- --- -- - - -ETR * * REMOVE AND REINSTALL EXISTING-
A-501
FINISH SCHEDULE
ROOM
NO.
ROOM
NAME BASE
FLOORS
FINISH
REMARKS
FINISH
WALLS
MAT FINISH
CEILING
MAT
ETR ETR *ETR/*PNT ETR -PARKINGB1-3
B1-14 STORAGE
SWITCHGEARB1-15
B1-16 TRANSFORMER VAULT
B1-17 MECHANICAL
* PNT TO MATCH EXISTING ADJACENT
FRAMES
FINISH
PNT-1
ETR ETR ETR - -ETR
PNT-2 ETR ETR/CMU PNT-1 ETR - * PNT TO MATCH EXISTING ADJACENTPNT-1
MAT
ETR
ETR
ETR
ETR/CMU
ETRPNT-2 ETR ETR ETR - ETRETR
ETR
ETRETR ETR ETR -ETR PNT-1
ETR
*ETR/*PNT * PNT TO MATCH EXISTING ADJACENT
B1-13 WORK ROOM ETR ETR ETR - ETRETRETR ETR
B1-12 OFFICE ETR ETR ETR - ETRETRETR ETR
B1-11 WORK ROOM ETR ETR ETR - ETRETRETR ETR
B2-A CORRIDOR
SWITCHGEAR
B2-5
B2-7
ETR ETR ETR - -ETR
PNT-2 ETR ETR ETR - ETRETR
ETR
PNT-2 ETR ETR - ETRETR
ETR ETR
TRANSFORMER VAULT
ETR ETR
ETR
101D ELECTRIC ROOM
141E
154D
ETR ETR ETR - -ETR
ETR - ETR
ETR
ETR - ETR
ETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
201D ELECTRIC ROOM
ETR ETR ETR - -ETR
ETR - ETR
ETRETR PNT-1
-ELECTRIC ROOM ETR ETR ETRETR PNT-1
301D ** ELECTRIC ROOM
331D **
331i **
ETR ETR ETR - ETR
ETR - ETR
ETR
ETR - ETR
ETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1 ** 431i; 531i; 631i; 731i; 831i; 931i SIMILAR
** 431D; 531D; 631D; 731D; 831D; 931D SIMILAR
** 401D; 501D; 601D; 701D; 801D; 901D SIMILAR
NOTE: ROOMS NOT IDENTIFIED ON THIS SCHEDULE, MAY ALSO REQUIRE PAINT FINISH TO MATCH EXISTING.
FINISH SCHEDULE
ROOM
NO.
ROOM
NAME BASE
FLOORS
FINISH
REMARKS
FINISH
WALLS
MAT FINISH
CEILING
MAT
ETR ETR *ETR/*PNT ETR -PARKINGB1-3
B1-14 STORAGE
SWITCHGEARB1-15
B1-16 TRANSFORMER VAULT
B1-17 MECHANICAL
* PNT TO MATCH EXISTING ADJACENT
FRAMES
FINISH
PNT-1
ETR ETR ETR - -ETR
PNT-2 ETR ETR/CMU PNT-1 ETR - * PNT TO MATCH EXISTING ADJACENTPNT-1
MAT
ETR
ETR
ETR
ETR/CMU
ETRPNT-2 ETR ETR ETR - ETRETR
ETR
ETRETR ETR ETR -ETR PNT-1
ETR
*ETR/*PNT * PNT TO MATCH EXISTING ADJACENT
B1-13 WORK ROOM ETR ETR ETR - ETRETRETR ETR
B1-12 OFFICE ETR ETR ETR - ETRETRETR ETR
B1-11 WORK ROOM ETR ETR ETR - ETRETRETR ETR
B2-A CORRIDOR
SWITCHGEAR
B2-5
B2-7
ETR ETR ETR - -ETR
PNT-2 ETR ETR ETR - ETRETR
ETR
PNT-2 ETR ETR - ETRETR
ETR ETR
TRANSFORMER VAULT
ETR ETR
ETR
101D ELECTRIC ROOM
141E
154D
ETR ETR ETR - -ETR
ETR - ETR
ETR
ETR - ETR
ETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
201D ELECTRIC ROOM
ETR ETR ETR - -ETR
ETR - ETR
ETRETR PNT-1
-ELECTRIC ROOM ETR ETR ETRETR PNT-1
301D ** ELECTRIC ROOM
331D **
331i **
ETR ETR ETR - ETR
ETR - ETR
ETR
ETR - ETR
ETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1
ELECTRIC ROOM ETR ETR ETRETR PNT-1 ** 431i; 531i; 631i; 731i; 831i; 931i SIMILAR
** 431D; 531D; 631D; 731D; 831D; 931D SIMILAR
** 401D; 501D; 601D; 701D; 801D; 901D SIMILAR
NOTE: ROOMS NOT IDENTIFIED ON THIS SCHEDULE, MAY ALSO REQUIRE PAINT FINISH TO MATCH EXISTING.
UNLESS SHOWN OTHERWISE, PARTITION TYPES SHALL BE CONTINUOUS IN THE SAME
PLANE FROM ONE CONDITION TO THE NEXT - ABOVE OR BELOW OPENINGS, ETC.
TYPE A1
CONCRETE SLAB
8" CMU
STRUCTURE ABOVE
DESIGN:
RATING:
MAS REINF @ 16"o.c.
VERT
B A
S E
P L A
N H
E A
D
SCALE: 1/4" = 1'-0"
DOOR TYPE AND DOOR FRAME TYPE
SCALE: 3" = 1'-0"
CMU HEAD DETAIL
DOOR SCHEDULE
SCALE: 3" = 1'-0"
CMU JAMB DETAIL
SCALE: 1/4" = 1'-0"
TYPICAL DOOR SECTION
FINISH SCHEDULE
SCALE: 3" = 1'-0"
PARTITION TYPE
PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED. Do not remove this notice. Properly destroy documents when no longer needed.
UPDN
UP DN UP DN
DN
UP
UP UP UP
1 01H
| G-001 |
| G-001 |
| Layout1 |
| AD101 |
| AD101 |
| Layout1 |
| AD102 |
| AD102 |
| Layout1 |
| A-101 |
| A-101 |
| Layout1 |
| A-102 |
| A-102 |
| Layout1 |
| A-501 |
| A-501 |
| Layout1 |
| ED-XXX.pdf |
| ED101-B2 |
| ED102-B1 |
| ED103-01 |
| ED104-02 |
| ED105-03 |
| ED106-04 |
| ED107-05 |
| ED108-06 |
| ED109-07 |
| ED110-08 |
| ED111-09 |
| ED112-P1 |
| ED401-B2 |
| ED402-B1 |
| EP-XXX.pdf |
| EP101-B2 |
| EP102-B1 |
| EP103-01 |
| EP104-02 |
| EP105-03 |
| EP106-04 |
| EP107-05 |
| EP108-06 |
| EP109-07 |
| EP110-08 |
| EP111-09 |
| EP112-P1 |
| EP401 |
| EP402 |
| EP403 |
| E-XXX.pdf |
| E-201 |
| E-501 |
| E-601 |
| E-602 |
| E-603 |
| E-604 |
| E-605 |
| E-606 |
| E-607 |
| E-608 |
| E-609 |
| E-610 |
| E-611 |
| E-612 |
| E-613 |
| E-614 |
| E-615 |
| E-616 |
| E-701 |
| E-702 |
| E-703 |
| E-704 |
| E-705 |
| E-706 |
| E-707 |
| E-708 |
| E-709 |
| E-710 |
| E-711 |
| E-712 |
| E-713 |
| E-714 |
| E-715 |
| E-716 |
| E-717 |
| E-718 |
| E-719 |
| E-720 |
| E-721 |
| E-722 |
| E-723 |
| E-724 |
| E-725 |
| E-726 |
| E-727 |
| E-728 |
| E-729 |
| E-730 |
| E-731 |
| E-732 |
| E-733 |
| E-734 |
| E-735 |
| E-736 |
| E-737 |
| E-738 |
| E-739 |
| E-740 |
| E-741 |
| E-742 |
| E-743 |
| E-744 |
| E-745 |
| E-746 |
| E-747 |
| E-748 |
| E-749 |
| E-750 |
| E-751 |
| E-752 |
| E-753 |
| E-754 |
| E-755 |
| E-756 |
| E-757 |
| E-758 |
| E-759 |
| E-760 |
| E-761 |
| E-762 |
| E-763 |
| E-764 |
| E-765 |
| E-766 |
| E-767 |
| E-768 |
| E-769 |
| E-770 |
| E-771 |
| E-772 |
| E-773 |
File details come from the government source that posted it. Updated .