Camera Maintenance SOW_Final 18 Feb 2020.pdf

PDF 231 KB Posted

Attached to
SFS CCTV CAMERA MAINTENANCE Federal contract opportunity
Solicitation number
FA820120Q0002
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

This statement of work outlines the requirements for a closed circuit television camera maintenance contract to be awarded by the Department of the Air Force Materiel Command Air Force Sustainment Center. The contractor shall provide quarterly preventative maintenance inspections of over three hundred CCTV cameras and associated equipment located across Hill Air Force Base in Utah. Services include inspecting, testing, cleaning and servicing cameras and components according to manufacturer specifications, as well as restoring unscheduled outages within defined timelines. The contract term is for one base year plus four option years. The contractor must have qualified personnel and follow all applicable regulations to perform technical services and repairs as specified in the statement of work.

View the file

Other files for this federal contract opportunity

Other files attached to SFS CCTV CAMERA MAINTENANCE, newest first.
File Type Posted
Contractor question Gov responses.pdf PDF
Solicitation Amendment - FA820120Q00020003.pdf PDF
Solicitation Amendment - FA820120Q00020001.pdf PDF
SBA.pdf PDF
Camera Maintenance SOW_Final.pdf PDF
Solicitation - FA820120Q0002.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date: 2/18/2020

STATEMENT OF WORK (SOW)

For

Installation Closed Circuit Television (CCTV) Camera Maintenance Located on Hill AFB, Utah

1. GENERAL: This is a non-personal services, to be on a firm-fixed price, contract to provide quarterly Preventive Maintenance Inspection (PMI) of Hill AFB cameras system to include all associated equipment such as cameras, camera housing units and cabling from the camera to the Network Switch, to include Ethernet/power extenders. The contractor shall also be responsible for service responses for unscheduled camera and associated equipment outages as outlined in this SOW. The government shall not exercise any supervision or control over the contract service providers performing the services herein. Video recorder, software, and camera connection to video recorder from the Network Switch will be managed by the Government. This contract will be funded for a base year and four option years.

1.1 Description of Services/Introduction: The contractor shall provide all personnel, expertise, equipment (to include lifts and ladders), supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform quarterly PMI as defined in this SOW except for those items specified as government furnished property and services. The contractor shall perform to the standards in this Statement of Work. The government will procure the cameras and parts and the contractor shall provide everything else required to PMI and repair/replace equipment. See paragraph 1.8.14 for further information.

1.2 Background: The Base Camera System is an enhanced security measure. The cameras provide security monitoring for gates and facilities on Hill AFB. The cameras also assist the Emergency Communications Center (ECC) in monitoring gates and facilities during and after normal duty hours.

1.3 Objectives: Inspect, test, clean and service all CCTV cameras and associated equipment. PMI work shall be accomplished in accordance with (IAW) manufacturer and maintenance manuals specifications for that specific equipment. Restore unscheduled service outages with the timelines outlined in this Statement of Work (SOW). All the required work shall be accomplished in accordance with United States Air Force regulations (AFI 31-101, Integrated Defense, and AFMAN 31-113, Installation Perimeter Access Control) and industry standards.

1.4 Scope: This SOW provides information for a contractor to provide the necessary trained and fully qualified personnel, supervision, task management, hardware, materials, tools, and technical services required for the successful accomplishment of the requirements and tasks set forth herein. Contractor shall be responsible for providing personnel with the necessary expertise to complete the assigned tasks satisfactorily. Personnel shall be capable of working independently and with demonstrated working knowledge of the equipment required by this SOW. Tasks include:

1) Notify Contracting Officer Representative (COR) if cameras need to be repaired or replaced. The contractor shall not be reimbursed in the event they purchase replacement parts or cameras. If the contractor procures replacement parts or cameras, and installs them on the base, it then becomes government property.

2) Inspect cabling and Ethernet and/or power extenders. Cabling consists of CAT VI, outdoor rated (outdoors and up to fifty (50) feet inside buildings) cabling from the camera to the switch, to include Ethernet and/or power extenders.

3) Inspect all camera angles of view to ensure unobstructed, clear view of intended visual assessment area.

4) Install new cameras, configure with IP address, run cables to connect to network switch, including necessary Ethernet and/or power extenders.

5) Perform an end-to-end power test of each camera location.

6) Inspect all power cables, fuses, circuit breakers, and lightning protection devices at each camera location.

7) Inspect the camera mounts at each location, repair, or replace as needed.

8) Inspect the lightning protection and grounding, repair as necessary.

9) Perform a complete system check upon completion of PMI Camera Assemblies.

10) Disassemble, visually inspect for cracks and corrosion, clean and repair all camera and housing assemblies.

11) Clean all contacts and connectors on the inside of the camera housings.

12) Test and repair interior heaters.

13) Replace desiccant packages within the camera housings.

14) Replace humidity detectors within camera housings.

15) Reassemble and weatherproof camera housings.

16) Recharge housings with Nitrogen after reassembly.

17) Repair and/or replace all broken/failing cameras.

18) Adhere to all safety rules and guidelines.

1.4.1 Scheduled Maintenance and Repair: The PMI shall be completed quarterly. The contractor shall notify and obtain approval from the on-site COR or designated representative in advance of scheduled PMI.

1.4.2 Service Calls: All camera systems shall be operational 24-hours-per-day, 7-days-per-week. The contractor shall provide a centralized call-in number and e-mail address for reporting outages or service issues.

It is not necessary that the centralized call-in number be manned 24/7, only that the contractor telephonically respond within 24 hours from the placement of the outage service call to begin troubleshooting the issue.

When telephone trouble-shooting is unable to resolve the problem, the Contractor shall dispatch a service technician to the site within one (1) duty day of the service call to begin repair of the system. The service technician must arrive on-site within the next business day to begin servicing/repairing of the system. Upon arrival at the site/location the Contractor is required to report in with the COR. Only the services specified by this agreement are authorized, the Contractor is cautioned that ONLY the Contracting Officer (CO) may authorize additional services and that any authorized services provided by the Contractor without proper authorization from the CO is done at Contractor’s risk and may not be reimbursed. The COR must be briefed on any work that needs to be accomplished and provided with a written work order documenting all work performed or services provided. All service calls shall be responded to without undue delay. The Contractor shall be responsible for ensuring that their personnel are instructed on performing service on Government property and are properly badged and easily identifiable. The contractor shall specify the starting time and duration of any interruptions along with what cameras will be affected. The contractor shall provide verbal notification to the on-site COR or designated representative immediately after service has been restored.

1.4.3 Replacement Parts: The contractor shall provide the COR a list of defective parts or stipulate if camera(s) need to be replaced. All equipment must meet the Air Force Security Forces Center Non-Nuclear Intrusion Detection System (IDS) Equipment Approval applications and configurations, including any model updated versions to the authorized Air Force list. All replaced equipment or parts remain the property of the Government. The Government retains the right to either approve or disapprove all parts, which are other than new Original Equipment Manufacturing (OEM), used in performance of this contract.

1.4.3.1 The cameras listed below are from the most current Air Force approved list, effective 15 August 2019. Cameras not on the approved list shall be replaced with cameras from the list as they require replacement. The Contractor shall contact the COR regarding an updated list as necessary.

• Aventura CAM -IPE-2XW Internet Protocol (11))

• Aventura CAM-IPM-8ZA-36X-1R (PTZ)

• + Bosch NWC-04-95-20P Internet Protocol (Il)) Camera

• + Bosch NWC-04-95-20P (1/3 Format)

• + Bosch NBN-498-21 P Internet Protocol (11)) Camera

• + Bosch Auto Dome VG 4-322-ECEIM

• + Bosch Auto Dome VG5-623-ECS

• + Bosch Auto Dome VG5-624-ECS

• + Bosch Auto Dome VG5-724-ECE2

• Bosch Auto Dome 7000 Internet Protocol (Il)) Camera with environmental housing

• + Bosch Dinion Internet Protocol (Il)) 7000 Camera with environmental housing Bosch DINION

Internet Protocol (Il)) Starlight 7000 HD (NBN-73013-BA)

• Bosch

• Bosch NBN-63023-B

• Bosch NBN-71013-13

• Bosch NBN-71022-13

• + Burle 300H Camera

• + Burle TC 351 Camera (1/2 inch format)

• + Cohu 4865 Camera (WS3) (2/3 inch format)

• + Cohu 48x Camera (KUMMSC) (2/3 inch format)

• + Cohu 4915/4912-3000 Camera (1/2 inch format)

• Cohu 3930HD

• Indigo Vision 512147 (PTZ)

• Indigo Vision 11650-Audio-HD

• + IQ Eye 752 Internet Protocol (IP) Camera

• + Lumenera Le 165M-DN Internet Protocol (IP) Camera

• Lumenera Le 165ME-DN Internet Protocol (IP) Camera with environmental housing

• + Lumenera Le 165MP-DN Internet Protocol (IP) Camera with environmental housing

• + Pelco ES3 ICBW35-2N Pan Tilt Zoom (PTZ) System

• + Pelco ES30C/ES31 C Pan Tilt Zoom (PTZ) System (1/4 inch format) with/ without optional

Wiper

• Pelco ES4136-2N Esprit ES system Pan Tilt Zoom (PTZ) System (1/4 inch format) with/ without optional Wiper

• + Pelco MC36511-1-2 Interior Camera (1/3 inch format)

• + Pelco IXE20 IP Camera

• Pelco ES4036-5W Esprit Series, with and without wiper, standard and pressurized

• + Pelco ES40E36-5W Esprit Series, with and without wiper, standard and pressurized Pelco

ES40/41 Series Positioning System, Analog, PTZ, w/wo wiper Esprit SE Standard & pressurized, model ES4036-5W

• Pelco ES40E/41E Series Positioning System, IP, PTZ, w/wo wiper Esprit SE Standard &

• Pressurized, Model ES40E36-5W

• Pelco IXE21 Internet Protocol (IP)

• Pelco P1220-ESR1 (PTZ)

• Pelco Sarix IXE Series Box Cameras w/ SureVision 3.0

• VICON SN680D-B-WNIR (PTZ)

• VICON IQ762W1-V6 Internet Protocol (11))

• + Vivotek IP 7151

• Vivotek SD8364E (PTZ)

• Vivotek IP816A-HP (interior only)

+ Indicates item is no longer procurable and/or supported by OEM; however it is still approved for use.

1.5 Original Equipment Manufacturer (OEM) Parts: Only new OEM parts or parts of equal quality (when authorized by the Government in advance) shall be used for repair. All replacement parts used for maintenance activities under this contract become the property of the Government. The faulty parts, which were replaced, shall be turned over to the COR and remain the property of the Government. The contractor may submit a listing of all anticipated parts which will not be new OEM but of equal quality to the COR for review and approval in advance of the work requirements or obtain the approval of the on-site COR or designated representative prior to installation of the parts. The Government retains the right to either approve or disapprove all parts, which are other than new OEM, used in performance of this contract.

1.6 Documentation: Contractor shall provide the following documentation: as-built drawings and descriptions, maintenance records and any manufacturer warranty information in .pdf format. Additionally, the contractor shall maintain and provide an up-to-date listing of all cameras and associated equipment locations.

1.7 Period of Performance: The period of performance will be for (1) base year and (4) option years.

1.8 General Information.

1.8.1 Quality Control (QC): The contractor shall develop and maintain an effective quality control program, to ensure services are performed in accordance with this SOW. The contractor shall develop and implement procedures to identify, prevent, and ensure non-recurrence of defective services. The contractor’s quality control program is the means by which he assures himself that his work complies with the requirements of the contract. A written quality control plan (QCP) shall be submitted within 30 days after contract award for acceptance. After acceptance of the quality control plan the contractor shall receive the contracting officer’s acceptance in writing of any proposed change to his QC system.

1.8.2 Quality Assurance: The government shall evaluate the contractor’s performance under this contract in accordance with the Quality Assurance Surveillance Plan. This plan is primarily focused on what the Government must do to ensure that the contractor has performed in accordance with the performance standards. It defines how the performance standards will be applied, the frequency of surveillance, and the minimum acceptable defect rate (s).

1.8.3 Recognized Holidays: The contractor is not required to perform PMI services on holidays.

New Year’s Day Labor Day Martin Luther King Jr.’s Birthday Columbus Day President’s Day Veteran’s Day Memorial Day Thanksgiving Day Independence Day Christmas Day

1.8.4 Hours of Operation: The contractor is responsible for conducting business, between the hours of 0730-

1630 Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies, administrative closings, or similar Government directed facility closings. For other than firm fixed price contracts, the contractor shall not be reimbursed when the government facility is closed for the above reasons. The Contractor must at all times maintain an adequate workforce for the uninterrupted performance of all tasks defined within this SOW when the Government facility is not closed for the above reasons.

1.8.5 Place of Performance: See attached equipment list. Work shall also be performed at Building 408/Emergency Communications Center (ECC) to verify all systems are operational.

1.8.6 Contractor Consent to Background Checks: The contractor and, as applicable, subcontractor shall not employ persons for work on this contract if such employee is identified as a potential threat to the health, safety, security, general well-being or operational mission of the installation and its population, nor shall the contractor or subcontractor employ persons under this contract who have an outstanding criminal warrant as identified by Utah Criminal Justice Information System (UCJIS) through the National Crime Information Center. UCJIS checks will verify if a person is wanted by local, state, and federal agencies. All contractor and subcontractor personnel must consent to UCJIS background checks.

Contractor and subcontractor personnel who do not consent to an UCJIS check will be denied access to the installation. Information required to conduct an UCJIS check includes: full name, driver’s license number, and/or social security number, date of birth of the person entering the installation, and completion of a background check questionnaire. The contractor shall provide this information using the Hill AFB Form 496, Application for Installation Access Control, to the COR no later than five business days prior to expected arrival to the installation. Completion of a successful UCJIS check does not invalidate the requirement for an escort when contractor or subcontractor personnel are working within controlled or restricted areas. Contractors shall ensure their employees and those of their subcontracts have the proper credentials allowing them to work in the United States. Persons later found to be undocumented or illegal aliens will be remanded to the proper authorities. The contractor shall not be entitled to any compensation for delays or expenses associated with complying with the provisions of this clause. Furthermore, nothing in this clause shall excuse the contractor from proceeding with the contract as required.

1.8.7 Access to Installation during Force Protection Conditions (FPCONs): Contractor access during FPCONs Charlie and Delta can be denied or limited as determined appropriate by the COR or higher authority.

1.8.8 Contractors Working in Controlled or Restricted Areas: Only contractor personnel with proper authority and qualifications shall enter a controlled or restricted area unless escorted. The unit requesting contract support will provide escort (s) for contractors at all times when within a controlled area.

Contractors shall not escort other contractor employees within controlled or restricted areas. The 75 SFS ESS will coordinate escort requirements as needed. In addition, contractors shall fulfill, maintain, and comply with all security requirements IAW AFI 31-101, Integrated Defense, and command/local directives. Due to specific mission requirements inherent in the nature of controlled or restricted areas on Hill AFB, the government may direct the contractor to leave the controlled or restricted areas at any given time.

1.8.9 Contracting Officer Representative (COR): The COR will be 75 SFS ESS or representative located in building 408, contact information is outlined below in 1.8.12. The COR monitors all technical aspects of the contract and assists in contract administration. The COR is authorized to perform the following functions: assure that the Contractor performs the technical requirements of the contract, perform inspections necessary in connection with contract performance, maintain written and oral communications with the Contractor concerning technical aspects of the contract, issue written interpretations of technical requirements, including Government drawings, designs, specifications, monitor Contractor's performance and notifies both the Contracting Officer and Contractor of any deficiencies, coordinate availability of government furnished property, and provide site entry of Contractor personnel. A letter of designation issued to the COR, a copy of which is sent to the Contractor, states the responsibilities and limitations of the COR, especially with regard to changes in cost or price, estimates or changes in delivery dates. The COR is not authorized to change any of the terms and conditions of the resulting order.

1.8.10 Key Personnel: The follow personnel are considered key personnel by the government:

Installation Security Section Electronic Systems Security Manager 75th Security Forces Squadron 75th Security Forces Squadron Phone: 801-777-6615 Currently:

Phone: 801-777-5532 Currently:

Email: robert.nolan.1@us.af.mil Email: robert.james.43@us.af.mil

1.8.11 The contractor shall provide a contract manager who shall be responsible for the performance of the work. The name of this person and an alternate who shall act for the contractor when the manager is absent shall be designated in writing to the contracting officer. The contract manager or alternate shall have full authority to act for the contractor on all contract matters relating to daily operation of this contract. The contract manager or alternate shall be available between 0730-1630, Monday thru Friday except Federal holidays or when the government facility is closed for administrative reasons.

1.8.12 Identification of Contractor Employees: All contract personnel attending meetings, answering Government telephones, and working in other situations where their contractor status is not obvious to third parties are required to identify themselves as such to avoid creating an impression in the minds of members of the public that they are Government officials. They must also ensure that all documents or reports produced by contractors are suitably marked as contractor products or that contractor participation is appropriately disclosed.

1.8.13 Administrator and Operator Passwords: All passwords (i.e. for Administrator and Operator) for the systems of operation shall be turned over to 75 SFS ESS upon completion of project.

1.8.14 Government Furnished Items and Services:

• Facilities: Security Forces will coordinate escorts, building access, communication room access and access to additional rooms and facilities as required.

• Utilities: The Contractor shall instruct employees in utilities conservation practices. The contractor shall be responsible for operating under conditions that preclude the waste of utilities.

• Equipment: The Government will not provide any equipment for this contract.

• Materials: The Government will not provide any materials for this contract.

Attachment: List of Equipment

A1.1 This list may not be all inclusive and is fluid in nature.

Camera

ID

Location Responsible Org PTZ Existing make and model, proposed replacement, added notes.

Survey Notes

Little

Mountain

LM1 Compound Gate Slide 4 Camera 1, SW External 4301

SFS No Axis P3364-L Corner Mount, Cat 5E Outdoor Rated; 100'

LM2 Building 4301 External NW corner Slide 4 Camera 2

SFS Yes Axis Q6045-E High Zoom Camera, Parapet Mount, Cat 5E Outdoor Rated; 200'

LM3 Building 850 West side External Slide 4 Camera 3

SFS Yes Axis Q6045-E High Zoom Camera, Tripod w/ Brace, Cat 5E Outdoor Rated; 200';

Needs 12 Port Switch

LM4 Building 850 external East side Slide 4 Camera 4

SFS Yes Axis Q6045-E Parapet Mount, Cat 5E Outdoor Rated; 200'

LM5 Building 4301 internal Slide 4 Camera 5

SFS No Axis P3364-L Interior Camera with Standard Lighting; replace with new dome and new wall mount; needs encoder/decoder

LM6 Building 4301 internal vault Slide 4 Camera

SFS No Axis P3364-L 2MP IR dome camera with mount;

needs encoder/decoder

LM7 Building 501 external South Slide 4 Camera

SFS Yes Axis Q6045-E Mount below existing camera;

Parapet Mount, Cat 5E Outdoor Rated; 200'; Needs 12 Port Switch

LM8 Main Gate inbound Slide 4 Camera 8

SFS No Axis P3364-L Requires encoder to switch; Cat 5E Indoor; Contractor shall run; * needs to be split one for network and the other to monitor

LM9 Main Gate outbound Slide 4 Camera 9

SFS No Axis P3364-L Requires encoder to switch; Cat 5E Indoor; Contractor shall run; * needs to be split one for network and the other to monitor

LM10 Building 2103 (water tower) external Slide 4 Camera 10

SFS Yes Axis Q6045-E Semi harsh conditions with possibility of lightning strike, Parapet Mount with brace for high winds, Cat 5E; 150'

LM11 North fence light post to watch the fence line and the exposed hiding spots from other cameras

SFS Yes

Requires 110 power supply, will require trenching, PTZ pole mount;

*Need Measurement*

UTTR

(ANALOG)(n o service)

UT1 Munitions Storage area gate Slide 5 Camera 1

Cisco Point-to-Point Wireless, Parapet mount; *Possible Pole Mount, does it need power*

UT2 Building 40020 VCC internal Slide 5 Camera

SFS No

Ceiling Dome; 50' Cat 5E Indoor Rated

UT3 Main gate inbound Slide 5 Camera 3

Encoder/Decoder

UT4 Main gate outbound Slide 5 Camera 4

SFS No

Fixed; Encoder/Decoder

Flight Line

FL1 Building 1477 Hotpad Slide 9 Camera 1

SFS, OSS Yes

Bosch

Pole Mount, Requires cable and power from wireless to camera; Cat 5E Outdoor; 25'

FL2 Building 772 Zulu area Slide 9 Camera 3

SFS, OSS Yes Axis Q6045-E Pole mount, requires 30' trench from building to pole, Cat 5E Outdoor, 100'

FL3 778 Zulu SFS, OSS Yes Axis Q6045-E Pole mount, requires 30' trench from building to pole, Cat 5E Outdoor, 100'

FL4 Building 772 Zulu area OSS Alert light pole camera Slide 9 Camera 4

OSS Yes Axis 6032-E

FL5 Hot Pad 1 Pole Mount Slide 9 Camera 5

OSS Yes Axis 6032-E

FL6 Building 900 NW Tarmac Slide 10 Camera 1

SFS, OSS, Fuels, LRS

Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 200'

FL7 Building 900 NE Tarmac Slide 10 Camera 2

SFS, OSS, Fuels, LRS

Yes Axis Q6032-E

FL7.5 Building 45 NW corner

SFS, OSS Yes Axis Q6045-E Corner mount and camera need to be purchased and provided to the PM. Will not be installed at this time due to construction on the building.

FL8 Building 43 Tarmac Slide 10 Camera 4

SFS, OSS Yes Axis Q6045-E Cat 5E Outdoor; 250', use existing conduit

FL9 Building 37 Tarmac Slide 10 Camera 5

SFS, OSS Yes Axis Q6045-E Cat 5E Outdoor; 250', use existing conduit

FL10 Building 25 Tarmac Slide 10 Camera 6

SFS, OSS Yes Axis Q6045-E Cat 5E Outdoor; 250', use existing conduit

FL11 Building 1 west to watch gate 52-P and hush houses Slide 10 Camera 7

SFS, OSS Yes Axis Q6045-E Cat 5E Outdoor; 200'

FL12 Building 5053 Tarmac Slide 10 Camera 8

Bosch

Pole mount, Cat 5E Outdoor; 40'

?? Building 5053 Tarmac OSS Slide 10 Camera 8b (not shown)

SFS, OSS Yes

Axis

FL13 Building 10 Tower North Slide 10 Camera 9

SFS, OSS Yes Axis Q6045-E Requires tie in to existing lightning protection, use existing BNC

FL14 Building 10 Tower North Slide 10 Camera 9b

(OSS)

SFS, OSS Yes Axis Q6032-E

FL15 Building 10 Tower South Slide 10 Camera 10

SFS Yes Axis Q6045-E Requires tie in to existing lightning protection, use existing BNC

FL16 Building 10 Tower South Slide 10 Camera 10b

(OSS)

SFS, OSS Yes Axis Q6032-E

FL17 Building 233 Northeast corner Slide 10 Camera 11

SFS, OSS Yes Axis Q6045-E Mk II Corner mount, Cat 5E Outdoor; 200'

FL18 Building 220 NE Tarmac Slide 10 Camera 12

SFS, OSS Yes Axis Q6045-E Encoder/Decoder required use existing BNC

FL19 Building 225 SW corner area to watch personnel gate and Building 237 Slide 10 Camera 14

SFS, OSS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 200'

FL20 Hanger 1 West, roof mount Slide 10 Camera 23

SFS, OSS Yes Axis Q6055-E

FL21 Hanger 1 East, roof mount Slide 10 Camera 24

SFS, OSS Yes Axis Q6032-E

FL22 Building 270 NW corner Slide 10 Camera 25

SFS, OSS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 250'

FL23 Building 590

SE

Tarma c Slide 11 Camera 6

SFS, OSS Yes Axis Q6045-E Parapet Mount, Cat 5E; 150' outdoor; *remove old camera*

FL24 Building 590 NE Tarmac Slide 11 Camera 7

SFS, OSS Yes Axis Q6045-E Parapet Mount, Cat 5E; 150' outdoor; *remove old camera*

FL25 Building 295 Tarmac. Slide 11 Camera 8

SFS, OSS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 200'

FL26 Building 578 NE corner Slide 11 Camera 11

OSS Yes

Axis

FL27 Building 680 SW corner Slide 9

SFS, OSS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 350' + signal booster

FL28 Building 680 SW corner Slide 9 Camera

OSS Yes Axis Q6032

FL29 Building 674 SW corner Slide 9

SFS, OSS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 300'

Command Center Building 133

CC1 Building 133 NW Outside Slide 10 Camera 15

SFS, CC Yes Axis Q6045-E MK II Pole mount, Cat 5E; 125' in conduit

CC2 Building 133 North, Northwest

DOOR

Outside Slide 10 Camera 16

SFS, CC Yes Axis Q6045-E MK II Parapet Mount, Cat 5E; 150' in conduit

CC3 Building 133 North, Northeast DOOR Outside Slide 10 Camera 17

SFS, CC Yes Axis Q6045-E MK II Parapet Mount, Cat 5E; 150' in conduit

CC4 Building 133 Southwest Outside Slide 10 Camera 18

SFS, CC Yes Axis Q6045-E MK II Parapet Mount, Cat 5E; 150' in conduit

CC5 Building 133 South door Outside Slide 10 Camera 19

SFS, CC Yes Axis Q6045-E MK II Parapet Mount, Cat 5E; 150' in conduit

Gates

G1 Building 541 South gate Slide 11 Camera 3

SFS Yes Axis Q6045-E MKII Pole mount, encoder/decoder required

G2 Building 542 Lobby Slide 11 Camera 4

SFS No Axis M3005 Interior mini dome in ceiling, Cat 5E interior, 50'

G3 Building 542 Parking Slide 11 Camera 5

SFS No Axis P3364-L Parapet Mount, Cat 5E Outdoor;

100'

G4 Building 886 SW Gate inbound Slide 12 Camera 2

SFS Yes Axis Q6045-E Pole mount, 50' trench, Cat 5E Outdoor; 100'

G5 Building 886 SW Gate outbound Slide 12 Camera 3

SFS Yes Axis 6045-E Pole mount, encoder/decoder required, use existing BNC

G6 Building 1299 West Gate VCC Parking lot Slide 12 Camera 4

SFS No Axis 6045-E

G7 Building 1299 West Gate Slide 12 Camera 5

SFS Yes Axis Q6045-E Pole mount use existing Cat 6 cable

G8 Building 1298 West Gate personnel revolving gate Slide 12 Camera 7

SFS No Axis P3364-L tie into existing system and need license

G9 Building 1299 VCC Lobby West Gate Slide 12 Camera 6

SFS No Axis P3364-L Interior mini dome in ceiling; Cat 6 interior; 30'

G10 Building 1964 Roy gate Truck traffic Slide 7 Camera 1

SFS Yes Axis Q6045-E Mk II Parapet Mount extension, Cat 5E Outdoor; 50'

G11 Building 1964 Roy Gate Commercial drivers VCC lobby internal Slide 7 Camera

SFS No Axis P3364-L Interior mini dome in ceiling; Cat 5E interior; 25'

G12 Building 1964 Roy Gate inbound and outbound traffic (light pole north mount) Slide 7 Camera 3

SFS Yes Axis Q6045-E Requires existing cable to be moved to self-contained box; hand hole;

Pole mount

G13 West Gate Outbound bldg

SFS Axis Q6045-E

G14 MSA I V-105

Gate

SFS No Axis P3364-L

G15 MSA I V-105

Gate Access Point

SFS No Axis P3364-L

LRS Fuels

LRS1 Tank Farm Tank 873 Slide 14 Camera 1

LRS Yes Axis Q6045-E Pole mount, Cat 5E Outdoor in explosive sealed conduit; 75'

LRS2 Tank Farm Tank 882 Slide 14 Camera 2

LRS Yes

Pole Mount, Point-to-Point Cisco Wireless (reuse firtide)

LRS3 Hydrant Building 905 NW corner Slide 14 Camera 3

LRS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor in explosive sealed conduit; 100'

LRS4 Hydrant Building 905 SE corner Slide 14 Camera 4

LRS Yes Axis Q645-E Corner mount, Cat 5E Outdoor in explosive sealed conduit; 100'

LRS5 Building 914 North Slide 14 Camera 5

LRS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor in explosive sealed conduit; 100'

LRS6 Building 911 NE Slide 14 Camera 6

LRS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor in explosive sealed conduit; 100'

LRS7 Building 911 SW Slide 14 Camera 7

LRS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor in explosive sealed conduit; 50'

LRS8 Building 911 SW side, lower mount to watch service station

LRS No Axis Q1765-LE-PT Telephoto camera, wall mount, Cat 5E Outdoor in explosive sealed conduit; 50'

LRS9 Building 911 LRS Axis Q1765-LE-PT

Buildings

B1 Building 1211 NW External Slide 8

SFS, SC Yes Bosch tie in to existing VMS, license required

B2 Building 1211 NE External Slide 8

SFS, SC Yes Bosch tie in to existing VMS, license required

B3 Building 1211 SW external Slide 8

SFS, SC Yes tie in to existing VMS, license required

B4 Building 1211 SE External Slide 8

SFS, SC Yes Bosch tie in to existing VMS, license required

B5 Building 1211 North Hallway internal Slide 8

SFS, SC No Bosch tie in to existing VMS, license required

B6 Building 1211 North Computer door Slide 8

SFS, SC No Bosch tie in to existing VMS, license required

B7 Building 1211 South Computer room door Slide 8

SFS, SC No Bosch tie in to existing VMS, license required

B7.5 Building 1211 SIPR Room

SFS, SC No Axis M3005

B8 Building 1214 NE External Slide 8

SFS, SC Yes Axis M7001 Video Encoder tie in to existing VMS, license required

B9 Building 1214 SW External Slide 8

SFS, SC Yes tie in to existing VMS, license required

B10 Building 1214 Computer Room East internal Slide 8

SFS, SC No Axis M7001 Video Encoder tie in to existing VMS, license required

B11 Building 1214 Computer Room West internal Slide

SFS, SC No Axis M7001 Video Encoder tie in to existing VMS, license required

B12 Building 533 Warrior Fitness Center Slide 11 Camera 2

SFS, FSS Yes AXIS Q6045 Cat 5E Outdoor; 100'

B13 Building 533 Warrior Fitness Center internal cameras Slide 11 Camera(s)

SFS, FSS No Axis M7016 Video Encoder Encoder/Decoder

B14 Building 520 Hess Fitness Center Slide 11 Camera(s)

SFS, FSS No Axis M7016 Video Encoder Encoder/Decoder, requires T-connection for multi streaming

B15 Building 850, Bay G Slide 13

SFS No Axis M3005 Ceiling Mount, Cat 6 Indoor; 100'

B16 Building 850, Bay F Slide 13 Camera 1

SFS, SC No Axis P3364-L Parapet Mount, Cat 6 Outdoor, requires conduit; 50'

B17 Building 850, Bay F Slide 13 Camera 2

SFS, SC No Axis P3364-L Corner Mount, Cat 6 Indoor; 250'

B18 Building 850, Bay F Slide 13

SFS, SC No Axis P3364-L Corner mount, Cat 6 Indoor; 100'

B19 Building 850, Bay F Slide 13 Camera 4

SFS, SC No Axis P3364-L Pole Mount, Cat 6 Indoor; 50'

B20 Building 850, Bay F Slide 13 Camera 5

SFS, SC No Axis P3364-L Ceiling Mount, Cat 6 Indoor; 75'

B21 Building 850, Bay F Slide 13 Camera 6

SFS, SC No Axis P3364-L Ceiling Mount, Cat 6 Indoor; 150'

B22 Building 5 SE corner External (to watch traffic and Gate 44-V Slide 10 Camera 20

SFS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 260'

B23 Building 36 NE Corner External (to watch Canterbury gate) Slide 10 Camera 21

SFS, OSS No Axis P3364 Corner mount, Cat 5E Outdoor; 80'

B24 Building 36 SW corner (to watch traffic) Slide 10 Camera 22

SFS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 200'

B25 Building 238 SW corner External (for watching traffic) Slide 11 Camera 1

SFS Yes Axis Q6045 Mk II Corner mount, Cat 5E Outdoor; 200'

B26 Building 845 NW corner External (for watching traffic) Slide 12 Camera 1

Corner mount, Cat 5E Outdoor; 450' + signal booster

B27 Building 900 South (for watching door entry and traffic) Slide 10 Camera 3

SFS, LRS Yes Axis Q6045-E Corner mount, Cat 5E Outdoor; 250'

B28 Building 408 North External Slide 10 Camera 25

SFS Yes Axis Q6032-E requires licenses

B29 Building 408 Lobby 1 Slide 10 Camera 25

SFS Yes Axis M5013 requires licenses

B30 Building 408 Lobby 2 Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B31 Building 408 Lobby 3/Hallway Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B32 Building 408 Armory Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B33 Building 408 Main hall East/West Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B34 Building 408 Main hall North/South Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B35 Building 408 OSI lobby Slide 10 Camera 25

SFS No Axis M5013 requires licenses

B36 Building 408 Interrogation Room

SFS Yes Axis M5013

B37 408 Warehouse

SFS

B38 408 Warehouse

SFS

B39 408 Warehouse

SFS

B40 Building 1217 Entry

SFS, ICBM Axis P3228-LV

729 ACS

ACS1 Bldg 1926 - 1926 01

729 ACS No HIKVision DS-2CD2131F-I

ACS2 Bldg 1926 - 1926 02

729 ACS No HIKVision DS-2CD2131F-I

ACS3 Bldg 1926 - 1926 03

729 ACS No HIKVision DS-2CD2131F-I

ACS4 Bldg 1926 - 1926 04

729 ACS No HIKVision DS-2CD2131F-I

ASC5 Bldg 1926 - 1926 05

729 ACS No HIKVision DS-2CD2131F-I

ACS6 Bldg 1926 - 1926 06

729 ACS No HIKVision DS-2CD2131F-I

ACS7 Bldg 1926 - 1926 07

729 ACS No HIKVision DS-2CD2131F-I

ACS8 Bldg 1926 - 1926 08

729 ACS No HIKVision DS-2CD2131F-I

ACS9 Bldg 1926 - 1926 09

729 ACS No HIKVision DS-2CD2131F-I

ACS10 Bldg 1926 - 1926 10

729 ACS No HIKVision DS-2CD2131F-I

ACS11 Bldg 1930 - 1930 01

729 ACS No HIKVision DS-2CD2131F-I

ACS12 Bldg 1930 - 1930 02

729 ACS No HIKVision DS-2CD2131F-I

ACS13 Bldg 1930 - 1930 03

729 ACS No HIKVision DS-2CD2131F-I

ACS14 Bldg 1930 - 1930 04

729 ACS No HIKVision DS-2CD2131F-I

ACS15 Bldg 1938 - 1938 01 Inside Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS16 Bldg 1938 - 1938 02 Outside

729 ACS No HIKVision DS-2CD2131F-I

ACS17 Bldg 1938 - 1938 03 Outside

729 ACS No HIKVision DS-2CD2131F-I

ACS18 Bldg 1938 - 1938 04 Exercise Rm

729 ACS No HIKVision DS-2CD2131F-I

ACS19 Bldg 1938 - 1938 05 Outside

729 ACS No HIKVision DS-2CD2131F-I

ACS20 Bldg 1938 - 1938 06 Inside Break rm

729 ACS No HIKVision DS-2CD2131F-I

ACS21 Bldg 1938 - 1938 07 Outside

729 ACS No HIKVision DS-2CD2131F-I

ACS22 Bldg 1938 - 1938 08 Inside Exercise Rm

729 ACS No HIKVision DS-2CD2131F-I

ACS23 Bldg 1938 - 1938 09 Inside Entry

729 ACS No HIKVision DS-2CD2131F-I

ACS24 Bldg 1938 - 1938 10 Inside Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS25 Bldg 1938 - 1938 11 Inside Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS26 Bldg 1938 - 1938 12 Outside Gate

729 ACS No HIKVision DS-2CD2131F-I

ACS27 Bldg 1938 - 1938 13 Inside Entry/Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS28 Bldg 1938 - 1938 14 Outside

729 ACS No HIKVision DS-2CD2131F-I

ACS29 Bldg 1938 - 1938 15 Outside Parking

729 ACS No HIKVision DS-2CD2131F-I

ACS30 Bldg 1938 - 1938 16 Inside Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS31 Bldg 1938 - 1938 17 Inside Hall

729 ACS No HIKVision DS-2CD2131F-I

ACS32 Bldg 1938 - 1938 18 Outside

729 ACS No HIKVision DS-2CD2131F-I

Museum

MU1 B1955 -

Lindquist Stewart Gallery

SE

No Axis P3225-LV Mk II

MU2 B1955 -

Lindquist Stewart Gallery SE Corner

No Axis P3225 LV Mk II

MU3 B1955 -

Lindquist Stewart Gallery S mid

No Axis P3225 LV Mk II

MU4 B1955 -

Lindquist Stewart Gallery

NE

No Axis P3225 LV Mk II

MU5 B1955 -

Lindquist Stewart Gallery NE Corner

No Axis P3225 LV Mk II

MU6 B1955 -

Lindquist Stewart Gallery NE Outside

No Axis P3225 LVE Mk II

MU7 B1955 -

Lindquist Stewart Gallery N. Mid

No Axis P3225 LV Mk II

MU8 B1955 -

Lindquist Stewart Gallery SE Outside

No Axis P3225 LVE Mk II

MU9 B1955 -

Lindquist Stewart Gallery 1st flr Class W

No Axis M3045-V

MU10 B1955 -

Lindquist Stewart Gallery NW Exit

No Axis M3045-V

MU11 B1955 -

Lindquist Stewart Gallery 2nd flr stair

No Axis M3045-V

MU12 B1955 -

Lindquist Stewart Gallery

NW

No Axis P3225 LV Mk II

MU13 B1955 -

Lindquist Stewart Gallery 1st flr Class E

No Axis M3045-V

MU14 B1955 -

Lindquist Stewart Gallery 2nd flr Comp lab E

No Axis M3045-V

MU15 B1955 -

Lindquist Stewart Gallery 1st flr Classroom Hall

No Axis M3045-V

MU16 B1955 -

Lindquist Stewart Gallery NW Corner

No Axis P3225 LV Mk II

MU17 B1955 -

Lindquist Stewart Gallery 2nd flr class W

No Axis M3045-V

MU18 B1955 -

Lindquist Stewart Gallery

SW

No Axis P3225 LV Mk II

MU19 B1955 -

Lindquist Stewart Gallery SW Corner

No Axis P3225 LV Mk II

MU20 B1955 -

Lindquist Stewart Gallery Walkway

No Axis M3045-V

MU21 B1955 - Hadley Gallery SE Corner

No Axis P3225 LV Mk II

MU22 B1955 - Hadley Gallery Center

No Axis P3225 LV Mk II

MU23 B1955 - Hadley Gallery NE Corner

No Axis P3225 LV

MU24 B1955 - Hadley Gallery NE Corner Outside

No Axis P3225 LVE

MU25 Spare

MU26 B1955 - Hadley Gallery NW Corner Outside

No Axis Q6055

MU27 B1955 - Hadley Gallery SW Corner

No Axis P3225 LV Mk II

MU28 B1955 - Hadley Gallery NW Corner

No Axis P3225 LV Mk II

MU29 B1955 - Hadley Gallery Walkway

No Axis M3045-V

MU30 B1955 -

Theater

No Axis M3045-V

MU31 Spare

MU32 B1955 - Lobby No Axis M3045-V

MU33 B1955 - North Entrance

No Axis P3225 LV Mk II

MU34 B1955 - Gift Shop Mid

No Axis M3045-V

MU35 B1955 - SE

Entrance - Admin Area

No Axis M3045-V

MU36 B1955 - NW

Gallery

No Axis M3045-V

MU37 B1955 - West Entrance

No Axis M3045-V

MU38 B1955 -

Outside North

No Axis P3225-LVE Mk II

MU39 B1955 - Gift Shop Counter

No Axis M3045-V

MU40 B1955 -

Outside NW

No Axis P3225-LVE Mk II

MU41 B1955 -

Outside SE

No Axis P3225-LVE Mk II

MU42 B1955 - Gift Shop South End

No Axis M3045-V

MU43 B1955 -

Outside SW

No Axis P3225-LVE Mk II

MU44 B1955 -

Parking

Yes Axis P3225-LVE

Building 1515 all cameras 50-

Building 1160 16 cameras

DLA

Building 849 multiple cameras DLA, some 309th. No numbers known

Hospital, unknown number of cameras

BX and Commissary unknown number of cameras or responsibility

Building 1246 8 cameras

UT5 Newfoundland Mtn West Slide 6 Camera

UTTR Security Yes

UT6 Newfoundland Mtn East Slide 6 Camera 2

UT7 UTTR North, North Lake location Slide 6

UT8 UTTR North, South lake location Slide 6 Camera 4

UT9 Grassy Mountain Complex Slide 6 Camera 5

UTTR Security Yes Remote location, electricity available, probably relay back via Microwave

UT10 UTTR South Knolls area Slide 6 Camera

UTTR Security Yes

UT11 UTTR South Gate 41 or also referred to as the UTTR South, North gate Slide 6 Camera 7

UTTR Security Yes

UT12 UTTR South HMOTS Site 87 Slide 6 Camera 8

UT13 S6 Gate (not shown on slides)

SFS Yes Pelco

UT14 S1 Gate (not shown on slides)

SFS Yes Pelco

UT15 Bravo Gate (not shown on slides)

SFS Yes Pelco