Revised_Drawing_AD101.pdf

PDF 183 KB Posted

Attached to
Repair of Bldg 1/1A Federal contract opportunity
Solicitation number
FA8201-15-B-0003
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Revised Drawing AD101

View the file

Other files for this federal contract opportunity

Other files attached to Repair of Bldg 1/1A, newest first.
File Type Posted
Revised_Drawing_AE610.pdf PDF
FA8201-15-B-0003_Amend_0005.pdf PDF
Revised_Contractor_Questions_and_Addendum_Items.pdf PDF
FA8201-15-B-0003_Amend_04.pdf PDF
Sabol_ _Rice _Inc_equipment_approval.pdf PDF
Pavement_Markings.pdf PDF
JRC_Lighting_equipment_approval.pdf PDF
Revised_Specification_Section_02_41_00_Demolition.pdf PDF
Revised_Schedule_of_Drawings.pdf PDF
Revised_Specification_Section_01_33_00_Submittal_Procedures.pdf PDF
Bldg_1A_Free_Zone.pdf PDF
FA8201-15-B-0003_Amend_0003.pdf PDF
Revised_Specification_Section_01_11_00_Summary_of_Work.pdf PDF
Contractor_Questions_and_Addendum_Items.pdf PDF
SSCO_Lighting_equipment_approval.PDF PDF
Revised_Drawing_AE601.pdf PDF
Amendment_FA8201-15-B-0003-0002.pdf PDF
Site_Visit_Attendance_Sheets.pdf PDF
Specifications_(6th_portion).zip ZIP file
Specifications_(3rd_portion).zip ZIP file
Specifications_(7th_portion).zip ZIP file
Specifications_(8th_portion).zip ZIP file
Specifications_(4th_portion).zip ZIP file
Specifications_(5th_portion).zip ZIP file
Amendment_FA8201-15-B-0003-01.pdf PDF
Specifications_(10th_portion).zip ZIP file
Specifications_(9th_portion).zip ZIP file
Specifications_(2nd_portion).zip ZIP file
Specifications_(1st_portion).zip ZIP file
Civil_Drawings.zip ZIP file
Attachments_1-15.zip ZIP file
FA8201-15-B-0003.pdf PDF
Mech_Drawings.zip ZIP file
Arch_Drawings.zip ZIP file
Structural_Drawings.zip ZIP file
General_Drawings.zip ZIP file
Elec_Drawings.zip ZIP file
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UPUP

A

B

C

E

F

H

I

K

L

2 3 4 5 6

65'-4" 3'-10"

5'-2 7/8"

6 1/8"

3'-4" 48'-5 1/4"

15'-4"

3'-10"

117'-10"

'-0

'-0

76'-0"

7 8 9 10 11 12 13

AA

BB

2A1A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A

7A.2 7A.7

REFERENCE CIVIL DRAWINGS FOR WORK AT EXTERIOR OF BUILDING

'-2

'-1

" 3

26'-8" 24'-8" 24'-8" 24'-8" 24'-8" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 21'-1 3/4"

'-8

'-8

'-8

'-8

'-8

'-8

'-8

'-8

'-1

6'-0" 27'-4 1/2" 9'-0" 21'-6" 21'-6" 21'-6" 21'-6" 22'-6" 22'-5 1/8" 21'-6" 21'-6" 21'-6" 21'-6" 9'-0" 28'-8 1/2" 6'-0"

CENTER

STICSI

GLO

AIR

OGDEN

GO

VE

RN

M

EN

T

RE

VI

EW

ER

DE

SI

GN

ED

B

Y:

DR

AW

N B

Y:

PR

O

JE

C T N U M B

ER

D E P A R

TM

E N T O F

TH

E

A

IR

F O R C E

TH

C

IV

IL

E N G

IN

E E R

IN

G

S Q U A D R O N

H I L L A

IR

F O R C E

B A S E

O G D E N

A

IR

LO

G

IS

TI

C S

C E N

TE

R

C H

EC

K

ED

B

Y:

D E S C R

IP

TI

O N

D A

TE

A P P R M A R K

SHEET OF 136

AD101

M

AI

N L

EV

EL

D

EM

O

LI

TI

O

N F

LO

O

R P

LA

N

BL

D

G

A W

S E P

M

AJ

O R

R E N

O V A

TI

O

N S

D e si g n e r

K R S M

A u th o r

C h e c ke r

GENERAL NOTES AND LEGEND:

KEYED NOTES:

� SEE SHEET G003 FOR GENERAL NOTES.

� SEE SHEET G002 FOR DRAWING INDEX.

� DO NOT SCALE DRAWINGS.

� CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS

AND CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT

TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR

OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND

SPECIFICATIONS.

� REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR

ADDITIONAL COORDINATION OF DEMOLITION.

� SOME LOCATIONS HAVE BATT INSULATION LAYING-ON OR ABOVE

EXISTING CEILINGS THAT ARE TO BE REMOVED. THE INSULATION

IS TO BE REMOVED AND LEGALLY DISPOSED OF.

1 EXISTING DOOR, DOOR FRAME & HARDWARE TO

BE REMOVED, DISPOSE.

2 EXISTING STUD AND GYP WALL TO BE

REMOVED, DISPOSE.

3 EXISTING MASONRY WALL TO BE REMOVED AS

INDICATED, DISPOSE.

4 EXISTING PRE-MANUFACTURED VAULT TO BE

REMOVED, DISPOSE.

5 EXISTING STUD AND GYP. BD FURRING TO BE

REMOVED, DISPOSE.

6 SAW-CUT EXISTING CONCRETE FLOOR SLAB AS

NEEDED FOR ACCESS TO EXISTING PLUMBING

LINES. COORDINATE WITH

MECHANICAL.PLUMBING DRAWINGS.

7 SAW-CUT HOLE IN EXISTING MASONRY WALL,

FOR NEW PIPE PENETRATION, COORDINATE

LOCATION WITH MECHANICAL/PLUMBING

DRAWINGS.

0'

SCALE : 1/8" = 1'-0"

8'4' 24'16' n AD101 1/16" = 1'-0"

A4MAIN LEVEL DEMOLITION FLOOR PLAN

1272619251C Callout

3. Remomve and replace window stytem

1272619251C Line

1272619251C Line

File details come from the government source that posted it. Updated .