Revised_Drawing_AD101.pdf
PDF 183 KB Posted
- Attached to
- Repair of Bldg 1/1A Federal contract opportunity
- Solicitation number
- FA8201-15-B-0003
About this file
Revised Drawing AD101
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UPUP
A
B
C
E
F
H
I
K
L
2 3 4 5 6
65'-4" 3'-10"
5'-2 7/8"
6 1/8"
3'-4" 48'-5 1/4"
15'-4"
3'-10"
117'-10"
'-0
'-0
76'-0"
7 8 9 10 11 12 13
AA
BB
2A1A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A
7A.2 7A.7
REFERENCE CIVIL DRAWINGS FOR WORK AT EXTERIOR OF BUILDING
'-2
'-1
" 3
26'-8" 24'-8" 24'-8" 24'-8" 24'-8" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 21'-1 3/4"
'-8
'-8
'-8
'-8
'-8
'-8
'-8
'-8
'-1
6'-0" 27'-4 1/2" 9'-0" 21'-6" 21'-6" 21'-6" 21'-6" 22'-6" 22'-5 1/8" 21'-6" 21'-6" 21'-6" 21'-6" 9'-0" 28'-8 1/2" 6'-0"
CENTER
STICSI
GLO
AIR
OGDEN
GO
VE
RN
M
EN
T
RE
VI
EW
ER
DE
SI
GN
ED
B
Y:
DR
AW
N B
Y:
PR
O
JE
C T N U M B
ER
D E P A R
TM
E N T O F
TH
E
A
IR
F O R C E
TH
C
IV
IL
E N G
IN
E E R
IN
G
S Q U A D R O N
H I L L A
IR
F O R C E
B A S E
O G D E N
A
IR
LO
G
IS
TI
C S
C E N
TE
R
C H
EC
K
ED
B
Y:
D E S C R
IP
TI
O N
D A
TE
A P P R M A R K
SHEET OF 136
AD101
M
AI
N L
EV
EL
D
EM
O
LI
TI
O
N F
LO
O
R P
LA
N
BL
D
G
A W
S E P
M
AJ
O R
R E N
O V A
TI
O
N S
D e si g n e r
K R S M
A u th o r
C h e c ke r
GENERAL NOTES AND LEGEND:
KEYED NOTES:
� SEE SHEET G003 FOR GENERAL NOTES.
� SEE SHEET G002 FOR DRAWING INDEX.
� DO NOT SCALE DRAWINGS.
� CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS
AND CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT
TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR
OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
� REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR
ADDITIONAL COORDINATION OF DEMOLITION.
� SOME LOCATIONS HAVE BATT INSULATION LAYING-ON OR ABOVE
EXISTING CEILINGS THAT ARE TO BE REMOVED. THE INSULATION
IS TO BE REMOVED AND LEGALLY DISPOSED OF.
1 EXISTING DOOR, DOOR FRAME & HARDWARE TO
BE REMOVED, DISPOSE.
2 EXISTING STUD AND GYP WALL TO BE
REMOVED, DISPOSE.
3 EXISTING MASONRY WALL TO BE REMOVED AS
INDICATED, DISPOSE.
4 EXISTING PRE-MANUFACTURED VAULT TO BE
REMOVED, DISPOSE.
5 EXISTING STUD AND GYP. BD FURRING TO BE
REMOVED, DISPOSE.
6 SAW-CUT EXISTING CONCRETE FLOOR SLAB AS
NEEDED FOR ACCESS TO EXISTING PLUMBING
LINES. COORDINATE WITH
MECHANICAL.PLUMBING DRAWINGS.
7 SAW-CUT HOLE IN EXISTING MASONRY WALL,
FOR NEW PIPE PENETRATION, COORDINATE
LOCATION WITH MECHANICAL/PLUMBING
DRAWINGS.
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n AD101 1/16" = 1'-0"
A4MAIN LEVEL DEMOLITION FLOOR PLAN
1272619251C Callout
3. Remomve and replace window stytem
1272619251C Line
1272619251C Line
File details come from the government source that posted it. Updated .