BUS DUCT
#1D2
I c
I
BI ;<1
I
REAL-TIME
X-RAY MACHINE
ROOM
NDI
~I tjD g:: D
I
I c
I
I
BI 17
ROTARY
TABLE
~:;;;-i ~---(
~ UTDMATE ,,,., I
~~ TRASDNI =
~ - SCANNING - 1~~
~ 'f ~ I t.. 1v1
GANTRY
f-- ~ - H o_
BUS DUCT #1D2
c
CRr c1t' zr p Fl ffi
CD
CONTROL
ROOM
COMPUTER
CONSOLE
ELECTRICA
CABINET
I CABINET I
LDAD/LJNL ~ AD/STAGING
I
I
N
PLAN VIEW
SCALE: 3/16"= 1'
SHEET NOTES:
A THIS PROJECT IS A TWO PART PROJECT:
1. FIRST PART IS TO INSTALL TEMP POWER TO TITAN X-RAY MACHINE (OC17387), AT THE FLOOR LEVEL, SO THAT
AIRCRAFT CAN TEST THE MACHINE. (MACHINE MIGHT NEED TO GO OUT FOR REPAIRS)
2. THE SECOND IS TO PERMANENTLY INSTALL THE X-RAY MACHINE TO THE LOW BAY FESTOONING TROLLEY SYSTEM
WITH NEW CABLE CARRIER ABOVE AND INSTALL WATER COOLER MACHINE ON INSIDE WALL.
B POINT OF CONTACT IS STEVE WEST AT 736-5020.
C CONTACT JONATHAN CRUZ AND GREGG ROBERTS FOR PRE-CONSTRUCTION MEETING TO DISCUSS PROJECT.
<I>
(J)
PHASE 1 KEYED NOTES:
EXISTING 120/208V PANEL #B16 WITH EXISTING 3P-60A-208V BREAKER #38-40-42.
DEMO EXISTING 3P-60A-208V NON-FUSED SAFETY SWITCH AND REPLACE WITH 1 EA NEW 3P-60A-208V FUSED DISCONNECT SWITCH, SQ D #H322N. INSTALL 3EA NEW 25 AMP FUSES, #LPN-RK25 WITH 3 SETS NEW FUSE
REDUCERS.
INSTALL EXISTING CUSTOMER PROVIDED 6KVA TRANSFORMER ONTO WALL IN THE NORTHEAST CORNER AT ~1 O' AFF
BETWEEN EXISTING CONDUITS USING NEW UNISTRUT AS NEEDED. INSTALL NEW 3/4" EMT/SEAL-TITE C/ 3#10 AND
1 #1 OGND FROM DISCONNECT SWITCH IN NOTE #2 TO LINE SIDE OF TRANSFORMER.
INSTALL NEW 3/4" EMT/SEAL-TITE C/ 3#10, 1#10N AND 1#10GND FROM LOAD SIDE OF TRANSFORMER TO 1EA CUSTOMER PROVIDED 400V 5-WIRE RECEPTACLE WITH RAISED METAL COVER. TEMPORARILY INSTALL RECEPTACLE AT
18" AFF ONTO WALL USING 1 EA NEW 4 SQ BOX.
TEMPORARILY INSTALL X-RAY MACHINE ON THE FLOOR AND INSTALL CUSTOMER PROVIDED SIGNAL CABLES FROM X-RAY MACHINE TO CONTROL ROOM FOR TESTING. AIRCRAFT TO TERMINATE CABLES IN CONTROL ROOM. SHEET METAL
SHOP WILL CUT IN NEW CABLE PORT IN LEAD WALL AS NEEDED.
PHASE 2 KEYED NOTES:
NEW CABLE CARRIER FESTOON SYSTEM WILL BE INSTALLED BY MECHANICAL SHOP AND USED FOR THE TRANSPORTATION OF LOW VOLTAGE SIGNAL CABLES AND X-RAY MACHINE POWER. SEE MECHANICAL DRAWING FOR
DETAILS.
INSTALL X-RAY EQUIPMENT ONTO EXISTING OVERHEAD LOW-BAY TROLLEY SYSTEM.
RELOCATE RECEPTACLE IN NOTE #4 AND INSTALL ON TROLLEY PLATFORM RACK ABOVE USING NEW 3/4" EMT C/ 3#10, 1 #1 ON AND 1 #1 OGND ON THE WALL FROM LOAD SIDE OF TRANSFORMER IN NOTE #3. INSTALL 4 SQ JUNCTION BOX AND TRANSITION TO NEW #10-5 SOOW TYPE CORD/CABLE ROUTED THROUGH NEW CABLE CARRIER FESTOON SYSTEM USING 2EA NEW STRAIGHT MALE THREAD CORD GRIPS, KELLUMS #074011249 AND NYLON TIE TO FESTOON
RACK.
RELOCATE EXISTING 20A-120V RECEPTACLE FED FROM PANEL #B16 CIRCUIT #8, CURRENTLY PROVIDING POWER TO TROLLEY, TO NEW LOCATION ABOVE EXISTING DISCONNECT SWITCH IN NOTE #2 AT ~11' AFF. INSTALL RECEPTACLE USING NEW 1/2" EMT C/ 1 #12, 1 #12N AND 1 #12GND FROM EXISTING LOCATION TO NEW LOCATION. PLUG IN AT NEW LOCATION AND RUN EXISTING TROLLEY POWER CORD THROUGH NEW CABLE CARRIER FESTOON SYSTEM AND
NYLON TIE TO FESTOON AS NEEDED.
INSTALL SIGNAL WIRING FROM WATER COOLER MACHINE TO OVERHEAD X-RAY MACHINE AS NEEDED, INSTALL CUSTOMER PROVIDED SIGNAL CABLES FROM TROLLEY X-RAY MACHINE TO CONTROL ROOM. INSTALL EACH CABLE INTO NEW WALL MOUNTED FESTOON SYSTEM AND THROUGH LEAD WALL OPENING TO CONTROL ROOM. INSTALL CABLES THROUGH NEW CABLE CARRIER FESTOON SYSTEM USING NYLON TIES TO PROTECT CABLES. CABLES TO BE
TERMINATED BY AIRCRAFT TECH IN CONTROL ROOM LOCATIONS.
RELOCATE EXISTING 3P-208V RECEPTACLE APPROX 3' NORTH OF CURRENT LOCATION AT SAME HEIGHT ON STEEL WALL USING NEW 3/4" EMT AND #10 WIRE. RECEPTACLE IS FED FROM PANEL #B-16 CIRCUIT #32-34-36.
12012•
1 BLACK
3 RED
" BLUE
7 BLACK
9 RED
1 1 BLUE
13 BL.ACK
15 RED
17 BLUE
19 BL.ACK
21 RED
23 BLUE
BL.ACK
27 RED
29 BLUE
31 BLACK
33 RED
35 BLUE
37 BLACK
39 RED
41 BLUE
I
1 BROWN
3 RANG
' 'l'ELLOY.
7 BROWN
9 RANG
1 1 '!'ELLO\\
13 BROWN
RANG
17 'r'ELLOY.
19 BROWN
21 RANG
23 YELLO'A
25 BROWN
27 RANG
29 'r'ELLOY.
31 BROWN
33 RANG
35 YELLO'A
BROWN
39 RANG ., \'ELLO\\
v
" 8
'" 28 32 ,.
" 8 " 18
" 40
U.S Air Force Tinker AFB
Okla homo City, OK m
" c N
I c c c c w
-"' ID -a
"' D x
D N D
"' I
"' " c " "" f-c VJ w w - ;,o u ~ w u G:i 0 ~ f-
Q_ "' v;
Q
C§ ___, i--: i--: [;l c::; ;::, "' "' 85 ~ " v;
""~ tl 0S ;"<:
{.,!)a ~ i"=5~ :::::i
~8Q-~ ::::;;. --J Q.. <:
Lu~a
::c "' ~ ~ 1-- CJ ::I:: I~~ g§§a8
CQGL...I~
~ ""'C ~ u f::;::::C:: ----Jua ~ G kl f:::: (.) A: f-: (..,) L.J ~ ~ ~ L:d::da.._a :o;:. ~ "' <: Li.J -.J a_ ~ 1-- ~ -.J
G§~~ a Q:: L.iJ I
~ ~ CL CJ
~ c:i Lu LC cj~~lJi -'.~r--5~ u
• D • z ~ N o a ' u 00 D ,., c 0)
I "" c ,,,.. w r::2 • c ·" "" > ~ k? • O'. <( es u
N w ca w u D D O'. C) x x 0
" Q:: " '-'
Project Number c c :g_ u m • D
-' c D c c •• '5 • "' c • m " c • c c c , ~ c u c -, ~ -•• • • " , 0 u m
" c N c
L
' • L
0 -c ii E • E • c
"' a u -0 D _, D ~ "' u ID ·a ~ u Q_ iii c
ID
c c a a:
m m m D x
16B005 Sheet E1 of 1