Questions_and_Answers_2.docx

DOCX document 15 KB Posted

Attached to
Transient Alert Services Tinker AFB - FA8101-15-R-0010 Federal contract opportunity
Solicitation number
FA8101-15-R-0010
Issued by
Department of the Air Force Materiel Command Air Force Sustainment Center

About this file

Responses to Questions 2

View the file

Other files for this federal contract opportunity

Other files attached to Transient Alert Services Tinker AFB - FA8101-15-R-0010, newest first.
File Type Posted
Q A3.docx DOCX document
SITE_VISIT.pdf PDF
Questions_and_Answers.docx DOCX document
Amended_Solicitation.doc DOC document
Amended_Solicitation.doc DOC document
Site_Vist.docx DOCX document
Questions_and_Answers.docx DOCX document
FA8101-15-R-0010_Transient_Alert.pdf PDF
PRICE_LIST_RESPONSE_PAGE.pdf PDF
PRICE_LIST_PAGE.docx DOCX document
FA8101-15-R-0010_Transient_Alert.pdf PDF
QUESTIONAIRE.doc DOC document
WDA.pdf PDF
PWS.pdf PDF
PROPOSED_TEAM_LIST.doc DOC document
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers:

Is there any requirement for Hydrazine response for F-16 aircraft?

A) No

While we understand that the requirement for vehicle not to be older than 10 years old by the end of the contract, is there any chance that the Government would reconsider that requirement for vehicles that are low use such as the Staircase Truck, Tugs, De-icer, and fleet vehicle?

A) No - At this time there will not be a change in the requirement.

Can the Government please define the actual de-iciing requirement? As the PWS is written, it appears that a substantial investment in a de-icing vehicle capable of reaching C-5 aircraft must be purchased while in actuality, this may not be a realistic requirement.

A) 1.1.1.7. The contractor shall provide a minimum of one (1) "Aircraft Deicer" Vehicle possessing the capability to provide aircraft deicing for all aircraft listed in APPENDIX F, Workload Estimates. This vehicle will be no more than 10 years old during the life of the contract.

Is the contractor required to apply both de-icing fluid and anti-icing fluid to the aircraft?

A) PWS has no requirements for Anti-Icing.

What is the largest airframe that the contractor would be required to de-ice/anti-ice?

A) The airframes are listed in the PWS, Appendix F - Workload Estimates.

If the contractor is required to de-ice/anti-ice only smaller airframes, would a unit without a boom to reach high places, satisfy contract requirements?

A) The airframes are listed in the PWS, Appendix F - Workload Estimates.