21-09-02 911th LOX - Specifications 17-0024 (323140).pdf

PDF 82 KB Posted

Attached to
CONSTRUCT SUPPORT EQUIPMENT PARKING SHELTER PROJECT JLSS 17-0024 OPTION FOR CONSTRUCT LIQUID OXYGEN STORAGE FACILITY, PROJECT JLSS 17-0001
Solicitation number
FA671221B0002
Issued by

View the file

Other files

File Type Posted
Solicitation Amendment FA671221B00020006 SF 30 date extend 0921.pdf PDF
Solicitation Amendment FA671221B00020005 SF 30 date extend update clause.pdf PDF
21-09-02 911th LOX - Specifications 17-0001 (323140).pdf PDF
21-09-02 911th LOX - Specifications 17-0001 (087100).pdf PDF
21-09-02 911th LOX - Specifications 17-0024 (087100).pdf PDF
lox Q and A Responses to Contractors Questions and NOTES.docx DOCX document
Solicitation Amendment FA671221B00020004 SF 30 date extend 0902.pdf PDF
Solicitation Amendment FA671221B00020003 SF 30 date extension 0819.pdf PDF
911AW LOX Site photo 5.jpg JPG image
911AW LOX Site photo 2.jpg JPG image
911AW LOX Site photo 9.jpg JPG image
Solicitation Amendment FA671221B00020002 SF 30.pdf PDF
911AW LOX Site photo 3.jpg JPG image
911AW LOX Site photo 7.jpg JPG image
911AW LOX Site photo 4.jpg JPG image
911AW LOX Site photo 8.jpg JPG image
911AW LOX Site photo 6.jpg JPG image
911AW LOX Site photo 1.jpg JPG image
Solicitation Amendment FA671221B00020001 SF 30.pdf PDF
lox 17-0024 and 17-0001 site visit sign in sheet.pdf PDF
0001 12 86 Request for Information Clin 0001 JLSS 0024.doc DOC document
Solicitation - FA671221B0002.pdf PDF
OPTION CLIN 0002 2- 20-09-14 JLSS 17-0001 DRAWINGS 2-17-2021.pdf PDF
OPTION CLIN 0002 1- 20-11-12 JLSS 17-0001 Specs 2-17-2021.pdf PDF
2021 CONTRACTOR-VISITOR ACCESS MEMO.pdf PDF
0002 86 Request for Information OPTION Clin 0002 JLSS 0001.doc DOC document
0001 1- 20-11-12 JLSS 17-0024 Specs 2-17-2021.pdf PDF
0001 2- 20-09-14 JLSS 17-0024 DRAWINGS 2-17-2021.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USAF 911th Airlift Wing 32 31 40 - 1 JLSS 17-0024

SECTION 32 31 40

HIGH SECURITY FENCES AND GATES

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. High security fences, gates and accessories.

1.2 RELATED REQUIREMENTS

A. Temporary Construction Fence: Section 01 00 00, GENERAL REQUIREMENTS.

B. Concrete Footings: Section 03 30 00, CAST-IN-PLACE CONCRETE.

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. ASTM International (ASTM):

1. A653/A653M-15e1 - Steel Sheet, Zinc-Coated (Galvanized) or Zinc Alloy-Coated

(Galvannealed) by Hot-Dip Process.

2. A924/A924M-14e1 - General Requirements for Steel Sheet, Metallic Coated by the Hot-dip

Process.

3. D2794-93(2010) - Test Method for Resistance of Organic Coatings to the Effects of Rapid

Deformation (Impact).

4. F2408-16 - Ornamental Fences Employing Galvanized Steel Tubular Pickets.

C. Master Painters Institute (MPI):

1. No. 18 - Primer, Zinc Rich, Organic.

1.4 SUBMITTALS

A. Submittal Procedures: Section 01 33 00, SUBMITTAL PROCEDURES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication and installation details.

C. Manufacturer's Literature and Data:

1. Description of each product.

D. Certificates: Certify products comply with specifications.

1. Fence alignment.

2. Zinc-coating complies with specifications.

3. Structural characteristics comply with indicated and criteria on Drawings.

4. Connections comply with requirements indicated on Drawings.

E. Qualifications: Substantiate qualifications comply with specifications.

1. Manufacturer.

2. Installer.

3. Welders and welding procedures.

USAF 911th Airlift Wing 32 31 40 - 2 JLSS 17-0024

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications:

1. Regularly manufactures specified products.

2. Manufactured specified products with satisfactory service on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

B. Installer Qualifications: Manufacturer authorized installer.

1. Regularly installs specified products.

2. Installed specified products with satisfactory service on five similar installations for minimum five years.

a. Project Experience List: Provide contact names and addresses for completed projects.

C. Welders and Welding Procedures Qualifications: AWS D1.1/D1.1M. or AWS D1.3/D1.3M.

1.6 DELIVERY

A. Deliver products in manufacturer's original sealed packaging.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.

1.7 STORAGE AND HANDLING

A. Store products indoor in dry, weathertight facility.

B. Protect products from damage during handling and construction operations.

1.8 FIELD CONDITIONS

A. Field Measurements: Verify field conditions affecting high security fence fabrication and installation. Show field measurements on Submittal Drawings.

1. Coordinate field measurement and fabrication schedule to avoid delay.

1.9 WARRANTY

A. Construction Warranty: FAR clause 52.246-21, "Warranty of Construction."

PART 2 - PRODUCTS

2.1 SYSTEM PERFORMANCE

A. System components includes pickets, pales, mesh, fabric, rails, posts, gates and hardware required with following performance requirements:

1. Steel Yield Strength: ASTM A924, minimum 344 MPa (50,000 psi).

2. Impact Resistance: ASTM D2794, over 6.8 Nm (60 in-lb.) when using 0.625 ball forward impact.

B. Gates: Design to meet same forced entry and anti-climb characteristics as other portions of fence.

USAF 911th Airlift Wing 32 31 40 - 3 JLSS 17-0024

2.2 MATERIALS

A. Zinc-Coated Steel: ASTM A653, G90 coating designation.

B. Tubular Steel: ASTM F2408.

C. Concrete: As specified in Section 03 30 00, Cast-in-Place Concrete.

2.3 PRODUCTS - GENERAL

A. Provide fence components from one manufacturer.

1. Steel Recycled Content: 30 percent total recycled content, minimum.

2.4 HIGH SECURITY FENCE

A. Pickets: Hot-dip galvanized steel, nominal 68.75 mm (2 3/4 inches) by 18.75 mm (3/4 inch) by

1.98 mm (0.078 inch) thick.

B. Rails: Hot-dip galvanized steel, nominal 50 mm (2 inch) square.

C. Gate Posts: Tubular steel, nominal 100 mm (4 inch) square.

1. Provide manually operated gates for vehicle access.

2. Provide hinged pedestrian gates with electric strike and card reader.

2.5 FABRICATION

A. Fabricate fence and gate to profile and dimensions indicated on Drawings.

B. Fabricate components with joints tightly fitted and secured.

2.6 FINISHES

A. Steel Paint Finish:

1. Powder-Coat Finish: Manufacturer's standard two-coat finish system as follows:

a. One coat primer.

b. One coat thermosetting topcoat.

c. Dry-film Thickness: 0.05 mm (2 mils) minimum.

d. Color: As selected by Architect.

B. Finish exposed surfaces after fabrication.

2.7 ACCESSORIES

A. Accessories: Manufacturer's required accessories for complete installation.

B. Barrier Coating: ASTM D1187/D1187M.

C. Welding Materials: AWS D1.1/D1.1M, type to suit application.

D. Fasteners: Fasteners as recommended by manufacturer.

E. Gate Hardware: Fence manufacturers standard hardware for manually operated gates.

F. Galvanizing Repair Paint: MPI No. 18.

G. Touch-Up Paint: Match shop finish.

USAF 911th Airlift Wing 32 31 40 - 4 JLSS 17-0024

PART 3 - EXECUTION

3.1 PREPARATION

A. Examine and verify substrate suitability for product installation.

B. Protect existing construction and completed work from damage.

3.2 INSTALLATION - GENERAL

A. Install products according to manufacturer's instructions and approved submittal drawings.

1. When manufacturer's instructions deviate from specifications, submit proposed resolution for

Contracting Officer's Representative consideration.

B. Excavate for concrete-embedded items.

C. Set posts in concrete foundation with a minimum depth of 914 mm (36 inches).

D. Attached fence panel to the line and end posts with manufacturer's standard fasteners.

E. Install gate to gate posts spaced as indicated on Drawings. Install required hardware and adjust for smooth operation.

F. Touch up damaged factory finishes.

1. Repair galvanized surfaces with galvanized repair paint.

2. Repair painted surfaces with touch up primer.

3.3 CLEANING

A. Clean exposed high security fence and gate surfaces. Remove contaminants and stains.

3.4 PROTECTION

A. Protect high security fences and gates from traffic and construction operations.

B. Remove protective materials immediately before acceptance.

C. Repair damage.

- - - E N D - - -