Environmental Report
Asbestos Containing Materials and Lead Based Paint Inspection for
Pittsburgh IAP 911th Airlift Wing at
Visiting Quarters – Building 209
Prepared for:
Pittsburgh IAP Air Reserve Station Coraopolis, PA
Prepared for:
L.Robert Kimball and Associates Inc.
415 Moon Clinton Road Coraopolis, PA
November 2009 ©
Asbestos Containing Materials and Lead based Paint Inspection Report for
Visiting Quarters – Building 209
911th Airlift Wing Coraopolis, Pennsylvania
Prepared for:
Pittsburgh IAP Air Reserve Station
Coraopolis, Pennsylvania
Prepared by:
L. Robert Kimball & Associates, Inc.
415 Moon Clinton Road
Coraopolis, Pennsylvania 15108
November 2009
Prepared by:
Richard C. Mance, PG Environmental Scientist Civil & Environmental Division
Reviewed by:
Steven D. Stockton
Assistant Operations Manager Civil & Environmental Division
911th Airlift Wing – VQ Building 209 Coraopolis, Pennsylvania Environmental Inspection
K:\MOON_SHARED\CE\ENVIRON\911th Air Lift VQ Bldgs\Bldg. 209\ACM Report.doc
The following materials have been sampled and found to be ACM.
Friable ACM
• Pipe Fitting Insulation
• Pipe Insulation Debris - observed in the front portion of the crawlspace on soil crawlspace floor. Debris appears to be residual from previous removal of thermal system pipe insulation and may be mixed with soil flooring.
Non-Friable ACM
• Older Drywall Joint Compound
• Basement Window Caulking
• Older Roof Flashing
The following materials have been assumed to be ACM. These materials were not sampled due to inaccessibility to materials, or because sampling would have damaged the function of the component associated with the material:
• Fire Door Insulation
Table 1
Cost Estimate Asbestos-Containing Materials
ACM LOCATION APPROXIMATE
QUANTITY
COST
ESTIMATE
Older Drywall Joint Compound
Basement Walls and Ceilings 7,000 Sq. Ft. $70,000.00
Pipe Fitting Insulation Basement Mechanical Room 2 Fittings $500.00
Pipe Insulation Debris2 Basement Crawlspace 1,000 Sq. Ft. $7,000.00
Basement Window Caulking Exterior Windows 6 Windows $600.00
Older Roof Flashing Original Main Roof - Attic 450 Sq. Ft. $1,800.00
Fire Doors Throughout Building 65 Doors $6500.00
TOTAL $86,400.00
1 Cost includes the removal of drywall sheeting associated with the joint compound.
2 Cost includes the asbestos abatement contractor cleaning entire crawlspace soil floor and if necessary, the removal of soil where debris has been observed to be mixed with soil in the affected areas.
Note: Cost estimates reflect unit pricing averages from select Pittsburgh base asbestos abatement firms. Costs may vary based on the magnitude of materials removed, and whether competitive bidding is used.
3.0 LEAD BASED PAINT
Four (4) paint systems were sampled throughout the building. Three (3) of the four (4) samples collected were found to contain lead above the laboratory limit of detection, at concentrations
1035668990C Highlight
911th Airlift Wing – VQ Building 209 Coraopolis, Pennsylvania Environmental Inspection
K:\MOON_SHARED\CE\ENVIRON\911th Air Lift VQ Bldgs\Bldg. 209\ACM Report.doc ranging from 0.041% to 0.46% lead by weight, and is therefore considered regulated under the Occupational Safety and Health Administration (OSHA).
Table 2 Lead Based Paint Sample Results
Substrate / Component Color Results
% By Weight Parts Per Million (ppm)
North Exterior Emergency Stair Tower Gray over Red 0.041 41
Basement Stairwell Door Jamb Salmon over Green 0.46 460
First Floor Window Sill Pink <0.0082 <8.2
Exterior Building NW Stairs Brown over White 0.089 89
The OSHA Lead in Construction Standard (29 CFR 1926.62) requires all contractors performing demolition or renovation activities to notify and provide training for their employees involved in the alteration and/or repair of lead-containing building components. The contractor is also required to conduct an initial Employee Exposure Assessment. There are no requirements for removing lead based paint during renovation or demolition of buildings however means of minimizing the migration of lead dust must be implemented. In addition, waste stream sampling of renovation waste materials is required under the Resource Conservation and Recovery Act
(RCRA).
The sample was analyzed by International Asbestos Testing Laboratories, Inc. of Mt. Laurel, New Jersey, using ASTM D3335-85A Atomic Absorption Spectrophotometry (AAS). IATL is accredited by the American Industrial Hygiene Association (AIHI) for metals analysis. The paint chip sampling form and the laboratory analysis are found in Appendix D – Lead-based Paint Sample Results.
4.0 MISCELLANEOUS MATERIALS
During the course of Kimball’s asbestos inspection, several other environmental factors were observed:
• Fluorescent light tubes potentially containing mercury were found throughout the building;
• Refrigerators and vending machines possibly containing regulated chlorofluorocarbon refrigerant; and
• Suspect Polychlorinated biphenyl (PCB) containing light ballasts are also present throughout the building.
1035668990C Highlight
PAINT CHIP SAMPLING FORM
BUILDING NAME: Visiting Quarters – Building 209
ADDRESS: 911 Air Wing Coraopolis, PA
SAMPLED BY: Richard Mance/Amanda Neary
DATE: October 13 and 28, 2009
K:\MOON_SHARED\CE\ENVIRON\911TH AIR LIFT VQ BLDGS\BLDG. 209\BLDG 209 PAINT CHIP FORM.DOC
REVISED 01/2004
Sample
No.
TESTING COMBINATION RESULTS
Location
Substrate/
Component
Color
% By
Weight
PPM
0808-209-01P North Exterior Emergency Stair Tower North Exterior
Emergency Stair Tower
Gray over Red 0.041 41
0808-209-01P Basement Stairwell Door Jamb Basement Stairwell Door Jamb
Salmon over Green 0.46 460
0808-209-01P First Floor Window Sill First Floor Window Sill Pink <0.0082 <8.2
0808-209-01P Exterior Building NW Stairs Exterior Building NW Stairs
Brown over White 0.089 89
Appendix D
Lead-Based Paint Chip Laboratory Sample Results
| Report Cover |
| ACM Report |
| 1.0 INTRODUCTION |
| 2.0 ASBESTOS INSPECTION |
| 2.1 Asbestos Sampling |
| 4.0 MISCELLANEOUS MATERIALS |
| 5.0 SUMMARY |
| divider sheets |
| List of Homogenous Areas |
| HA# |
| YES |
| Bldg. 209 Bulk Sampling Form |
| SAMPLE |
| MATERIAL |
| HA # |
| Bldg 209 Paint Chip form |
| Location |
| ACM Photograph Log |
| ACM Photograph Information |
| IATL2 |
| Certs |