B1654_Asbestos_and_Lead-Based_Paint_Sampling_Report_(April_18,_2017).pdf
PDF 3 MB Posted
- Attached to
- Building 1654 Renovation Federal contract opportunity
- Solicitation number
- FA667519RA005
About this file
B1654 Asbestos & Lead-Based Paint Sampling Report
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_Responses-V5.pdf | ||
| RFI_Responses-V4.pdf | ||
| RFI_Responses-V3.pdf | ||
| RFI_Responses-V2.pdf | ||
| RFI_Responses.pdf | ||
| RFI_Responses.pdf | ||
| B1654_Pre-bid_Site_Visit_Sign-in_Sheet.pdf | ||
| DOL_Wage_Determination.pdf | ||
| B1654_Past_Perf_Questionnaire.pdf | ||
| SPEC_SECT_12_24_13_WINDOW_SHADES_(A001).pdf | ||
| NASJRB-1654Renovation_Specifications_27July2018.pdf | ||
| NASJRB_B1654_SubmittalRegister.xls | XLS spreadsheet | |
| NASJRB-1654Renovation_Drawings_27July2018.pdf | ||
| RFI_-RFC_FORM.pdf | ||
| SPEC_SECT_12_59_00_FURNITURE_SPECS_(A001).pdf | ||
| Solicitation_-_FA667519RA005.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey and Lead-Based Paint Sampling Report
Naval Air Station Joint Reserve Base (NASJRB)
Building 1654
Fort Worth, Texas
April 18, 2017
Terracon Project No. 95167571
Prepared for:
Blair Remy Architects
Oklahoma City, Oklahoma 73104
Prepared by:
Terracon Consultants, Inc.
Fort Worth, Texas 76118
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
2.0 SITE DESCRIPTION
3.0 ASBESTOS FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 LEAD-BASED PAINT FIELD ACTIVITIES
4.1 Site Limitations
4.2 Methodology and Analysis
5.0 REGULATORY OVERVIEW
5.1 Asbestos Regulations
5.2 Lead-Based Paint Regulations
6.0 FINDINGS AND RECOMMENDATIONS
7.0 GENERAL COMMENTS
APPENDIX A CONFIRMED ASBESTOS CONTAINING MATERIALS
APPENDIX B ASBESTOS SURVEY SAMPLE SUMMARY
APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA
APPENDIX D LEAD-BASED PAINT SAMPLE RESULTS
APPENDIX E LEAD-BASED PAINT ANALYTICAL LABORATORY DATA
APPENDIX F LICENSES AND CERTIFICATIONS
Responsive ■ Resourceful ■ Reliable 1
ASBESTOS SURVEY AND LEAD-BASED PAINT
SAMPLING REPORT
Naval Air Station Joint Reserve Base (NASJRB)
Building 1654
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey and lead-based paint (LBP) chip sampling prior to the proposed renovation of Building 1654 at the Naval
Air Station Joint Reserve Base (NASJRB) in Fort Worth, Texas. The asbestos survey and lead-based paint sampling was conducted on March 22 – 24, 2017 and March 31, 2017 by a State of Texas licensed Asbestos Inspector/Lead Risk Assessor in general accordance with Terracon Proposal No. P95167571 dated September 28, 2016.
Interior and exterior building components were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented.
Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids, or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in Environmental Protection Agency (EPA) regulation 40 CFR 763
(Asbestos Hazard Emergency Response Act, AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).
1.1 Project Objective
The objective of the asbestos survey was to identify the presence and location of accessible friable and nonfriable ACM present on the interior and exterior of Building
1654 located at the NASJRB.
The Texas Asbestos Health Protection Rules (TAHPR) and EPA regulation 40 CFR 61, Subpart M, The National Emission Standards for Hazardous Air Pollutants (NESHAP) requires that an asbestos survey be performed prior to renovation or demolition activities.
The objective of the LBP sampling was to identify accessible LBP on the interior and exterior of the Building 1654. The LBP sampling was limited to readily observable and accessible surfaces. Based on information provided by the client, the building is proposed for renovation.
Asbestos Survey and Lead-Based Paint Sampling NASJRB ■ Building 1654 ■ Fort Worth, Texas April 18, 2017 ■ Terracon Project No. 95167571
Responsive ■ Resourceful ■ Reliable 2
Regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than 0.5% of lead by weight for buildings that meet the definition of target housing. The Occupational Safety and Health Administration (OSHA) define LBP as a paint which contains lead, regardless of the concentration. Due to the nature of the site, the OSHA regulations will apply to the construction and/or demolition activities, since the site does not meet the definition of a child occupied facility or target housing.
2.0 SITE DESCRIPTION
Building 1654 is a single-story structure that measures approximately 26,300 square feet. The exteriors walls consist of textured cementitious wall panels and textured brick.
The building has a pitched membrane roof over an existing tar and gravel roof on a metal deck.
The interior walls consist of textured drywall, ceramic tile on drywall, and unfinished concrete masonry unit (CMU) block. The floors consist of carpet, ceramic floor tile, and vinyl floor tile on a concrete substrate. The ceilings consist of a lay-in ceiling tile system suspended from the metal deck. No fireproofing was observed on the metal deck on the day of the survey
3.0 ASBESTOS FIELD ACTIVITIES
The asbestos survey and LBP sampling was conducted by Mr. Chad Champagne, a
Texas Department of State Health Services (TDSHS) licensed Asbestos Inspector
(License No. 60-3112). Copies of licenses and certifications are attached in Appendix E.
The asbestos survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the Asbestos Hazard Emergency
Response Act (AHERA). A summary of survey activities is provided below.
3.1 Visual Assessment
Our survey activities began with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, texture, and date of application. The assessment was conducted throughout visually accessible areas of the building. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.
Responsive ■ Resourceful ■ Reliable 3
3.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Asbestos Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. Sample team members collected bulk samples using wet methods as applicable to reduce the potential for fiber release.
Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
One hundred fifty-nine (159) bulk samples were collected from forty-seven (47) homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix A.
3.4 Sample Analysis
Suspect ACM samples were delivered under proper chain of custody to Cates
Laboratories, of Dallas, Texas, an accredited National Voluntary Laboratory
Accreditation Program (NVLAP) (Lab No. 200569-0) and TDSHS (License No. 30-0287) licensed laboratory for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA Method 600/R-93/116. The percentage of asbestos where applicable, was determined by microscopic visual estimation.
4.0 LEAD-BASED PAINT FIELD ACTIVITIES
4.1 Site Limitations
It should be noted that suspect LBP, other than those identified during the sampling, may exist within the building and/or on the building exterior that was inaccessible. If suspect
LBP is identified, those materials should be assumed to LBP until testing can be performed to determine if lead is present in the paint.
4.2 Methodology and Analysis
The LBP sampling was conducted by Mr. Chad Champagne, a TDSHS certified Lead Risk
Assessor (Certification No. 2071012). The LBP sampling was conducted by scraping
Responsive ■ Resourceful ■ Reliable 4 approximately one square inch of paint from the supporting substrate. Ten (10) samples were submitted to Environmental Hazards Services, L.L.C. of Richmond, VA, a National
Environmental Laboratory Accreditation Program (NELAP) certified (Certificate No.
T104704248-11-3) and AIHA accredited (Lab ID: 100420) accredited laboratory. The analysis was performed by Flame Atomic Absorption Spectrophotometry, EPA method
(EPA SW846 7000B). The limit of detection (LOD) for this analytical method ranged from
<37 ppm to <3400 ppm based on the weight of the sample. Sample results reported below the LOD may contain lead at a concentration below the analytically defined LOD.
A summary of the lead based paint samples and analysis is included in Appendix D.
No materials were assumed to be LBP. Any inaccessible areas that contain painted surfaces should be tested when access permits or should be assumed to be positive for
Lead-Based Paint.
5.0 REGULATORY OVERVIEW
5.1 Asbestos Regulations
The State of Texas has established the TAHPR which requires any asbestos-related activity to be performed by an individual licensed by the State of Texas, through the
TDSHS. An asbestos related activity consists of the disturbance (whether intentional or unintentional), removal, encapsulation, or enclosure of asbestos, including preparations or final clearance, the performance of asbestos surveys, the development of management plans and response actions, asbestos project design, the collection or analysis of asbestos samples, monitoring for airborne asbestos, bidding for a contract for any of these activities, or any other activity required to be licensed under TAHPR.
Abatement must be performed by a State of Texas licensed asbestos abatement contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be conducted during the abatement activities.
The asbestos NESHAP (40 CFR Part 61 Subpart M) regulates asbestos fiber emission and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity.
Under NESHAP, asbestos containing building materials are classified as either friable, Category I nonfriable or Category II nonfriable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure.
Category I nonfriable ACM includes packing, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II nonfriable ACM are any materials other than Category I materials that contain more than 1% asbestos.
Responsive ■ Resourceful ■ Reliable 5
Friable ACM, Category I and II nonfriable ACM in poor condition and has become friable or which will be subject to drilling, sanding, grinding, cutting, or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM). The TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any asbestos-containing material (ACM) in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least 10 working days prior to the commencement of asbestos abatement or demolition activities. Removal of RACM must be conducted by a State of Texas licensed asbestos contractor. In addition, third party air monitoring must be performed during the abatement.
The Occupational Safety and Health Administration (OSHA) Asbestos standard for the construction industry (29 CFR 1926.1101) regulates workplace exposure to asbestos.
The OSHA standard requires employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc).
The OSHA standard classifies construction and maintenance activities which could disturb
ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States that administer their own federally approved state OSHA programs may require other precautions.
5.2 Lead-Based Paint Regulations
The State of Texas has established the Texas Environmental Lead Reduction Rules
(TELRR) to establish the means to control and minimize public exposure to lead by regulating lead-based paint activities in target housing and child-occupied facilities. The
TELRR contains procedures and requirements for the accreditation of lead training providers, procedures and requirements for the certification of individuals and firms engaged in lead-based paint activities and standards for performing such activities in target housing and child-occupied facilities. The TELRR also requires that all lead-based paint activities in target housing and child-occupied facilities be performed by certified individuals.
As a point of reference, regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than
0.5% of lead by weight for buildings that meet the definition of target housing. OSHA, however, defines LBP as a paint which contains lead, regardless of the concentration.
The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint.
OSHA considers paint containing any level of lead above the analytical method detection
Responsive ■ Resourceful ■ Reliable 6 limit a potential hazard which should be communicated to any employees or contractors who may disturb the materials in the course of their assigned work.
6.0 FINDINGS AND RECOMMENDATIONS
Asbestos
Based on the results of the laboratory analyses, asbestos was confirmed in the following materials:
Carpet mastic
Floor tile with mastic under carpet (2 types)
Exterior window caulk
Exterior soffit
The identified asbestos containing materials were assessed to be nonfriable and in good condition on the day of the survey. The identified asbestos containing materials must be abated prior to renovation activities if those materials will potentially be disturbed.
The asbestos abatement must be performed by a State of Texas licensed asbestos contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be performed during the abatement.
It is important to note the TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any
ACM in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least ten (10) working days prior to the commencement of asbestos abatement or demolition activities. These activities must be performed in accordance with the current TDSHS, EPA, and OSHA guidelines.
Lead-Based Paint
A total of ten (10) paint chip samples were collected and none of the samples contained lead above the HUD standard of 5,000 ppm, which would render the material “Lead-
Containing” (considered a potential hazard by OSHA). A summary of the components tested, location of the measurement, and results are provided in Appendix D.
Any renovation activities conducted in Building 1654 would be subject to OSHA regulations (29 CFR 1926.62 – Lead Exposure in Construction). The OSHA regulation defines specific training requirements, engineering controls and working practices for construction personnel subject to this standard.
Responsive ■ Resourceful ■ Reliable 7
It is unlikely component removal and/or painting activities planned would present a lead hazard to personnel, however, it is recommended that contracting personnel who may disturb the paint as part of the planned renovations should be made aware of the lead content in the materials so that they may exercise proper OSHA procedures for personnel protection or possibly employ protective procedures when working with the materials.
Compliance with applicable OSHA lead regulations is the responsibility of the contractor performing the work and it is recommended that they be required to communicate potential lead hazards to their workforce and utilize lead-safe work practices such as outlined in the EPA Renovation, Repair, and Painting Final Rule (40 CFR 745) or applicable portions of the Structural Steel Painting Council (SSPC) Guidelines. It is further recommended that activities such as flame/torch dismantling, dry sanding and/or dry grinding of any components with lead-containing materials applied should be prohibited as part of any repair, renovation or demolition activity.
7.0 GENERAL COMMENTS
This asbestos survey/LBP sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Blair
Remy Architects for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
CONFIRMED ASBESTOS-CONTAINING MATERIALS
Naval Air Station Joint Reserve Base (NASJRB)
Building 1654
Sample No.
Material Location (Area) Friable/
Nonfriable Assessed Condition
Estimated Quantity
32, 33, 34 Carpet Mastic (Brown) associated with Northwest Renovation Area
Rooms 113, 113.1, 113.4, 113,5, Corridor 113.2, and Adjacent
Closed 113.3 Nonfriable Good
1,870 square feet
64, 65, 66 Floor Tile under Carpet with Mastic (Black) associated with East Addition
Rooms 147, 148, 154, 156, 157, 159, 160, 161, 162, 163, 165, 166, 167, 174, 175, 176, 177, 178, 179, 179.1, 180, and Corridor 115
Nonfriable Good 5,830 square feet
122, 123, Floor Tile under Carpet with Mastic (Black) associated with Main Building
Rooms 104, 105, 106, 106.1, 107, 108, 109, 110, 111, 120, 121, 122, 123, 140, 141, 142, 143, 144, 145, 146, 149, 149.1, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, and 195
Nonfriable Good 8,370 square feet
148, 149, Exterior Window Caulk (Gray) South Windows Nonfriable Good 240 linear feet
(6 square feet)
154, 155, Exterior Soffit (Gray) Perimeter of Building Exterior Nonfriable Good 1,550 square feet
APPENDIX B
ASBESTOS SURVEY SAMPLE SUMMARY
Naval Air Station Joint Reserve Base (NASJRB)
Building 1654
Material Asbestos Containing Sample Numbers
2’ x 2’ Ceiling Tile (White, Pinholes, Rough)
No 1, 2, 3
2’ x 4’ Ceiling Tile (White, Pinholes, Rough)
No 4, 5, 6
2’ x 2’ Ceiling Tile (White, Heavy Rough) associated with Northwest Renovated Area
No 7, 8, 9
Wall Texture (White, Orange Peel) with Drywall and Joint Compound
No 10, 11, 12, 13, 14, 15, 16
4” x 4” Ceramic Wall Tile (White) with Grout (Gray) and Thinset (Tan)
No 17, 18, 19
Cove Base Mastic (Tan) No 20, 21, 22
2’ x 2’ Ceiling Tile (White, Pinholes and Pockmarks)
No 23, 24, 25
Thermal System Insulation Mastic (White)
No 26, 27, 28
Carpet Mastic (Green) associated with Blue Carpet Squares
No 29, 30, 31
Carpet Mastic (Brown) associated with Northwest Renovation Area
Yes 32, 33, 34
24” x 24” Ceramic Floor Tile (Gray, Mottled) with Grout (Gray) and Thinset (White)
No 35, 36, 37
2” x 2” Ceramic Floor Tile (Gray) with Grout (Gray) and Thinset (Tan)
No 38, 39, 40
12” x 12” Ceramic Floor Tile (Tan and Gray, Mottled) with Grout (Gray) and Thinset (White)
No 41, 42, 43
12” x 12” Ceramic Floor Tile (Brown, Mottled) with Grout (Brown) and Thinset (Tan)
No 44, 45, 46
Sink Undercoating (White) No 47, 48, 49
Wall Texture (White, Semi-Smooth) with Drywall and Joint Compound associated with Northwest Renovation
No 50, 51, 52, 53, 54
12” x 12” Vinyl Floor Tile (White with Blue and Gray Streaks) with Mastic (Brown)
No 55, 56, 57
Wall Covering (Gray) No 58, 59, 60
Interior Building Caulk (White) associated with Plumbing Fixtures
No 61, 62, 63
Floor Tile under Carpet with Mastic (Black) associated with East Addition
Yes 64, 65, 66
Interior Window Caulk (White) No 67, 68, 69
Interior Door Caulk (White) associated with Office Doors
No 70, 71, 72
Interior Door Caulk (White) associated with Entry Doors
No 73, 74, 75
Interior Door Caulk (Black) associated with Corridor Security Doors
No 76, 77, 78
Wall Texture (White, Semi-Smooth) with Drywall and Joint Compound
No 79, 80, 81, 82, 83
Carpet Mastic (Green) associated with Command Post
No 84, 85, 86
Duct Mastic (White) No 87, 88, 89
Duct Mastic (Gray) No 90, 91, 91
Thermal System Pipe Insulation associated with Mechanical Room
No 93, 94, 95
Thermal System Pipe Insulation Fittings associated with Mechanical Room
No 96, 97, 98
Wall Texture (White, Orange Peel) with Drywall and Joint Compound associated with East Addition
No 99, 100, 101, 102, Cove Base Mastic (Tan) associated with East Addition
No 104, 105, 106
Floor Tile under Carpet with Mastic (Yellow)
No 107, 108, 109
Deck Insulation (Yellow) No 110, 111, 112
Interior Building Caulk associated with Janitor Sink
No 113, 114, 115
Thermal System Pipe Insulation (Brown)
No 116, 117, 118
Floor Tile under Carpet (Blue) with Mastic (Yellow) associated with Break Room
No 119, 120, 121
Floor Tile under Carpet with Mastic (Black) associated with Main Building
Yes 122, 123, 124
Exterior Building Texture (Tan) No 125, 126, 127, 128, 129, 130, 131
Exterior Building Texture (White) associated with Brick
No 132, 133, 134, 135, 136, 137, 138
Expansion Joint Caulk (Tan) No 139, 140, 141
Exterior Door/Window Caulk (Tan) No 142, 143, 144
Exterior Door Caulk (White) No 145, 146, 147
Exterior Window Caulk (Gray) Yes 148, 149, 150
Expansion Joint Caulk (White) No 151, 152, 153
Exterior Soffit (Gray) Yes 154, 155, 156
Roof Membrane No 157, 158, 159
APPENDIX C
ASBESTOS LABORATORY ANALYTICAL REPORTS
PLM REPORT SUMMARY
Cates Laboratories NVLAP Lab No. 200569-0
1339 Motor Circle TDSHS License No. 30-0287
Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-14221
Project: NASJRB - Building 1654 Set No.: 21319
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 1 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Lab
Sample No.
Client
Field I.D.
Sample Description/Location Asbestos Content
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced except in full.
CL527032
2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, East
None Detected
CL527033
2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, Center
CL527034
2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, West
CL527035
2' X 4' Ceiling Tile (white, pinholes, rough) - Corridor 115
CL527036
2' X 4' Ceiling Tile (white, pinholes, rough) - Room 160
CL527037
2' X 4' Ceiling Tile (white, pinholes, rough) - Room 161
CL527038
2' X 2' Ceiling Tile (white, heavy rough) associated w/Post Renovation
Areas - Room 113.5
CL527039
Areas - Room 113
CL527040
Areas - Room 113.1
CL527041
Wall Texture (white, orange peel) w/Drywall & Joint Compound -
Corridor 127
None Detected - Paint Texture
None Detected - Joint Tape
None Detected - Joint Compound
None Detected - Paper
None Detected - Wallboard Material
CL527042
Wall Texture (white, orange peel) w/Drywall & Joint Compound - Room
None Detected - Joint Compound
CL527043
Vestibule 126
None Detected - Joint Compound
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 2 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527044
None Detected - Joint Compound
CL527045
104, Lobby
None Detected - Joint Compound
CL527046
Corridor 127, West
None Detected - Joint Compound
CL527047
None Detected - Joint Compound
CL527048
4" X 4" Ceramic Wall Tile (white) w/Grout (gray) & Thinset (tan) -
Room 101
None Detected - Ceramic Tile
None Detected - Grout
None Detected - Thinset
CL527049
CL527050
CL527051
Cove Base Mastic (tan) - Room 160
CL527052
Cove Base Mastic (tan) - Room 159
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 3 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527053
Cove Base Mastic (tan) - Room 154.1
CL527054
2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 101
CL527055
2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 101
CL527056
2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 102
CL527057
Thermal System Insulation Mastic (white) - Room 160
None Detected - White Mastic
None Detected - Wrap
None Detected - Insulation
CL527058
Thermal System Insulation Mastic (white) - Room 151
CL527059
Thermal System Insulation Mastic (white) - Restroom 101
CL527060
Carpet Mastic (green) associated w/Blue Carpet Squares - Auditorium
CL527061
CL527062
CL527063
Carpet Mastic (brown) associated w/Northwest Renovation Area - Room
113.1, Closet
5% Chrysotile
CL527064
113, Closet
CL527065
113.5
CL527066
24" X 24" Ceramic Floor Tile (gray, mottled) w/Grout (gray) & Thinset
(white) - Corridor 127, East
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 4 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527067
(white) - Corridor 127, Center
CL527068
(white) - Corridor 127, West
CL527069
2" X 2" Ceramic Floor Tile (gray) w/Grout (gray) & Thinset (tan) -
Restroom 101
None Detected - Grout/Thinset
CL527070
CL527071
Restroom 102
CL527072
12" X 12" Ceramic Floor Tile (tan & gray, mottled) w/Grout (gray) &
Thinset (white) - Room 182
CL527073
Thinset (white) - Room 104, Lobby, East
CL527074
Thinset (white) - Room 104, Lobby, West
CL527075
12" X 12" Ceramic Floor Tile (brown, mottled) w/Grout (brown) &
Thinset (tan) - Room 125
CL527076
CL527077
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 5 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527078
Sink Undercoating (white) - Room 125
CL527079
CL527080
CL527081
Wall Texture (white, semi-smooth) w/Drywall & Joint Compound associated w/Northwest Renovation Area - Room 113
None Detected - Joint Compound
CL527082
associated w/Northwest Renovation Area - Room 113.1, Closet
None Detected - Joint Compound
CL527083
associated w/Northwest Renovation Area - Room 113, Closet
None Detected - Joint Compound
CL527084
associated w/Northwest Renovation Area - Room 113.4
None Detected - Joint Compound
CL527085
associated w/Northwest Renovation Area - Room 113.5
None Detected - Joint Compound
CL527086
12" X 12" Vinyl Floor Tile (white w/blue & gray streaks) w/Mastic
(brown) - Janitor's Closet 103
None Detected - Floor Tile
None Detected - Yellow Mastic
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 6 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527087
CL527088
CL527089
Wall Covering (gray) - Restroom 101
CL527090
CL527091
CL527092
Interior Building Caulk (white) associated w/Plumbing Fixtures -
CL527093
CL527094
CL527095
Floor Tile under Carpet w/Mastic (black) associated w/East Addition -
Room 160
5% Chrysotile - Floor Tile
5% Chrysotile - Black Mastic
CL527096
Corridor 115
CL527097
Room 157
CL527098
Interior Window Caulk (white) - Room 165
CL527099
Interior Window Caulk (white) - Room 183
CL527100
Interior Window Caulk (white) - Room 113.1
CL527101
Interior Door Caulk (white) associated w/Office Doors - Room 161, Entry
Door
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 7 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527102
Interior Door Caulk (white) associated w/Office Doors - Room 181, Entry
CL527103
Interior Door Caulk (white) associated w/Office Doors - Room 191, Entry
CL527104
Interior Door Caulk (white) associated w/Entry Doors - East Entry Door
CL527105
Interior Door Caulk (white) associated w/Entry Doors - North Entry Door
CL527106
Interior Door Caulk (white) associated w/Entry Doors - West Entry Door
CL527107
Interior Door Caulk (black) associated w/Corridor Security Door -
Corridor 124, Security Door
CL527108
Corridor 124, Security Door
CL527109
Command Center Corridor
CL527110
Wall Texture (white, semi-smooth) w/Drywall & Joint Compound -
Janitor's Closet 103
None Detected - Joint Compound
CL527111
None Detected - Joint Compound
CL527112
None Detected - Joint Compound
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 8 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527113
Mechanical Room 119
None Detected - Joint Compound
CL527114
None Detected - Joint Compound
CL527115
Carpet Mastic (green) associated w/Command Post - Room 138
CL527116
Carpet Mastic (green) associated w/Command Post - Room 139
CL527117
Carpet Mastic (green) associated w/Command Post - Room 132
CL527118
Duct Mastic (white) - Corridor adjacent to North Entry
CL527119
CL527120
CL527121
Duct Mastic (gray) - Corridor 127, East
CL527122
Duct Mastic (gray) - Room 160
CL527123
Duct Mastic (gray) - Restroom 101
CL527124
Thermal System Pipe Insulation associated w/Mechanical Room -
CL527125
CL527126
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 9 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527127
Thermal System Pipe Insulation Fittings associated w/Mechanical Room -
CL527128
CL527129
CL527130
Wall Texture (white, orange peel) w/Drywall & Joint Compound associated w/East Addition - Corridor 115
None Detected - Joint Compound
CL527131
associated w/East Addition - Room 165
None Detected - Joint Compound
CL527132
associated w/East Addition - Room 162
None Detected - Joint Compound
CL527133
associated w/East Addition - Room 167
None Detected - Joint Compound
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 10 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527134
associated w/East Addition - Room 160
None Detected - Joint Compound
CL527135
Cove Base Mastic associated w/East Addition - Room 160
CL527136
Cove Base Mastic associated w/East Addition - Room 161
CL527137
Cove Base Mastic associated w/East Addition - Room 167
CL527138
Floor Tile under Carpet w/Mastic (yellow) - Room 170
CL527139
Floor Tile under Carpet w/Mastic (yellow) - Corridor 114
CL527140
Floor Tile under Carpet w/Mastic (yellow) - Room 179
CL527141
Deck Insulation (yellow) w/White Powder - Corridor 127, East
None Detected - Powder Material
CL527142
Deck Insulation (yellow) w/White Powder - Corridor 127, Center
CL527143
Deck Insulation (yellow) w/White Powder - Classroom 151
CL527144
Interior Building Caulk associated w/Janitor Sinks - Janitor's Closet 103
CL527145
CL527146
CL527147
Thermal System Pipe Insulation (brown) - Corridor 127, North
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 11 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527148
CL527149
CL527150
Floor Tile under Carpet (blue) w/Mastic (yellow) associated w/Break
Room - Break Room 154.1
CL527151
CL527152
CL527153
Floor Tile under Carpet w/Mastic (black) associated w/Main Building -
Room 181
CL527154
Room 104
CL527155
Room 123
CL527156
Exterior Building Texture (tan) - Southwest Corner
None Detected - Stucco
CL527157
Exterior Building Texture (tan) - North Exterior Wall
CL527158
Exterior Building Texture (tan) - North Exterior Wall
CL527159
Exterior Building Texture (tan) - Northeast Corner
CL527160
Exterior Building Texture (tan) - East Exterior Wall
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 12 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527161
Exterior Building Texture (tan) - East Exterior Wall
CL527162
Exterior Building Texture (tan) - Southeast Corner
CL527163
Exterior Building Texture (white) associated w/Brick - South Exterior
Wall, Southwest Corner
None Detected - Brick
CL527164
Wall, West
CL527165
Wall, Center
CL527166
Wall, Center
CL527167
Wall, East
CL527168
Wall, East
CL527169
Wall, Southeast Corner
CL527170
Expansion Joint Caulk (tan) - Southwest Corner
CL527171
Expansion Joint Caulk (tan) - Northwest Corner
CL527172
Expansion Joint Caulk (tan) - North Exterior Wall
CL527173
Exterior Door/Window Caulk (tan) - East Entry Doors
CL527174
Exterior Door/Window Caulk (tan) - Northeast Windows
CL527175
Exterior Door/Window Caulk (tan) - West Windows
CL527176
Exterior Door Caulk (white) - Command Post, Exterior Entry Door
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 13 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by
CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL527177
Exterior Door Caulk (white) - Room 123, Exterior Entry Door
CL527178
Exterior Door Caulk (white) - Mechanical Room 119, Exterior Entry
CL527179
Exterior Window Caulk (gray) - South Windows
3% Chrysotile
CL527180
CL527181
CL527182
Expansion Joint Caulk (white) - South Exterior Wall
CL527183
CL527184
CL527185
Exterior Soffit (gray) - Southeast Soffit
20% Chrysotile
CL527186
Exterior Soffit (gray) - Southwest Soffit
CL527187
Exterior Soffit (gray) - Southwest Soffit
CL527188
Roof Membrane - South Roof
None Detected - Roofing Membrane 1
None Detected - Roofing Membrane 2
None Detected - Roofing Insulation
None Detected - Roofing Foam
CL527189
Roof Membrane - Southeast Roof
None Detected - Roofing Membrane
None Detected - Roofing Tar
CL527190
Roof Membrane - North Roof
None Detected - Roofing Membrane 1
None Detected - Roofing Membrane 2
Project No: 95167571 Report Date: 4/5/2017
Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017
Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 14 of 14
On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein.
STATEMENT OF LABORATORY ACCREDITATION
The samples were analyzed in general accordance with the procedures outlined in the Method for the
Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116 or the U.S. Environmental
Protection Agency method, under AHERA (EPA 600/M4-82-020), for the analysis of asbestos in building materials by polarized light microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Specific questions concerning bulk sample results shall be directed to the Laboratory Director.
Analyst:
Jessica Scott
Laboratory Director: John R. Cates, P.G.
Approved Signatory:
NVLAP LAB CODE 200569-0
APPENDIX D
Lead Based Paint Sample Results
Naval Air Station Joint Reserve Base (NASJRB)
Building 1654
Sample Number
Sample Location
Component Lead
Concentration
(ppm)
South Exterior
Wall White Paint on Metal Conduit <670
South Exterior
Wall Brown Paint on Metal Downspout <420
South Exterior
Wall White Paint on Brick Exterior Wall <37
East Exterior
Wall Tan Paint on Textured Exterior Wall 58
5 East Entry Brown Paint on Metal Guardrail <110
6 East Corridor Gray Paint on Metal Door Frame <1700
7 Room 160 White Paint on Drywall <46
8 Room 113 White Paint on Drywall <48
9 Room 113.5 White Paint on Metal Door Frame <38
South Exterior
Mechanical Room
Gray Paint on Metal Exterior Door <3400
APPENDIX E
LEAD-BASED PAINT ANALYTICAL LABORATORY DATA
Analysis Report
Client:
Project/Test Address:
Terracon - Ft. Worth
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
NASJRB; Building 1654; 1510 Chennault Ave; Fort Worth, Texas
Client Number:
45-5814
Fax Number:
817-268-8602Laboratory Results
Analyzed Date:
Client Sample Number
Lab Sample Number
Pb (ug/g) ppm
Lead Paint Chip
04/06/2017
04/05/2017
17-04-00433
Reported Date:
Received Date:
Report Number:
2501 E. Loop 820, North Ft. Worth, TX 76118
Narrative
ID
04/06/2017
Collection Location % Pb by Wt.
03/31/2017Collection Date:
117-04-00433-001 L03CONDUIT <670 <0.067
217-04-00433-002 L03DOWNSPOUT <420 <0.042
317-04-00433-003 WALL <37 <0.0037
417-04-00433-004 WALL 58 0.0058
517-04-00433-005 L03GUARDRAIL <110 <0.011
617-04-00433-006 L03DOOR <1700 <0.17
717-04-00433-007 L04WALL <46 <0.0046
817-04-00433-008 WALL <48 <0.0048
917-04-00433-009 L03DOOR FRAME <38 <0.0038
1017-04-00433-010 L03DOOR <3400 <0.34
Page 2of1
Report Number:
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: 17-04-00433
NASJRB; Building 1654; 1510 Chennault Ave; Fort Worth, Texas
45-5814
Collection LocationClient Sample Number
Lab Sample Number
% Pb by Wt.
Narrative
ID
Pb (ug/g) ppm
Missy Kanode
QA/QC Clerk
Analysis Method: EPA SW846 7000B
The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) for samples prepared by ASTM E-1979-12 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 3050B is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.
LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight
Reviewed By Authorized Signatory:
L03: Sample submitted was less than the…