B1654_Asbestos_and_Lead-Based_Paint_Sampling_Report_(April_18,_2017).pdf

PDF 3 MB Posted

Attached to
Building 1654 Renovation Federal contract opportunity
Solicitation number
FA667519RA005
Issued by
Department of the Air Force Reserve Command

About this file

B1654 Asbestos & Lead-Based Paint Sampling Report

View the file

Other files for this federal contract opportunity

Other files attached to Building 1654 Renovation, newest first.
File Type Posted
RFI_Responses-V5.pdf PDF
RFI_Responses-V4.pdf PDF
RFI_Responses-V3.pdf PDF
RFI_Responses-V2.pdf PDF
RFI_Responses.pdf PDF
RFI_Responses.pdf PDF
B1654_Pre-bid_Site_Visit_Sign-in_Sheet.pdf PDF
DOL_Wage_Determination.pdf PDF
B1654_Past_Perf_Questionnaire.pdf PDF
SPEC_SECT_12_24_13_WINDOW_SHADES_(A001).pdf PDF
NASJRB-1654Renovation_Specifications_27July2018.pdf PDF
NASJRB_B1654_SubmittalRegister.xls XLS spreadsheet
NASJRB-1654Renovation_Drawings_27July2018.pdf PDF
RFI_-RFC_FORM.pdf PDF
SPEC_SECT_12_59_00_FURNITURE_SPECS_(A001).pdf PDF
Solicitation_-_FA667519RA005.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Survey and Lead-Based Paint Sampling Report

Naval Air Station Joint Reserve Base (NASJRB)

Building 1654

Fort Worth, Texas

April 18, 2017

Terracon Project No. 95167571

Prepared for:

Blair Remy Architects

Oklahoma City, Oklahoma 73104

Prepared by:

Terracon Consultants, Inc.

Fort Worth, Texas 76118

TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Project Objective

2.0 SITE DESCRIPTION

3.0 ASBESTOS FIELD ACTIVITIES

3.1 Visual Assessment

3.2 Physical Assessment

3.3 Sample Collection

3.4 Sample Analysis

4.0 LEAD-BASED PAINT FIELD ACTIVITIES

4.1 Site Limitations

4.2 Methodology and Analysis

5.0 REGULATORY OVERVIEW

5.1 Asbestos Regulations

5.2 Lead-Based Paint Regulations

6.0 FINDINGS AND RECOMMENDATIONS

7.0 GENERAL COMMENTS

APPENDIX A CONFIRMED ASBESTOS CONTAINING MATERIALS

APPENDIX B ASBESTOS SURVEY SAMPLE SUMMARY

APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA

APPENDIX D LEAD-BASED PAINT SAMPLE RESULTS

APPENDIX E LEAD-BASED PAINT ANALYTICAL LABORATORY DATA

APPENDIX F LICENSES AND CERTIFICATIONS

Responsive ■ Resourceful ■ Reliable 1

ASBESTOS SURVEY AND LEAD-BASED PAINT

SAMPLING REPORT

Naval Air Station Joint Reserve Base (NASJRB)

Building 1654

1.0 INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted an asbestos survey and lead-based paint (LBP) chip sampling prior to the proposed renovation of Building 1654 at the Naval

Air Station Joint Reserve Base (NASJRB) in Fort Worth, Texas. The asbestos survey and lead-based paint sampling was conducted on March 22 – 24, 2017 and March 31, 2017 by a State of Texas licensed Asbestos Inspector/Lead Risk Assessor in general accordance with Terracon Proposal No. P95167571 dated September 28, 2016.

Interior and exterior building components were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented.

Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids, or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in Environmental Protection Agency (EPA) regulation 40 CFR 763

(Asbestos Hazard Emergency Response Act, AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).

1.1 Project Objective

The objective of the asbestos survey was to identify the presence and location of accessible friable and nonfriable ACM present on the interior and exterior of Building

1654 located at the NASJRB.

The Texas Asbestos Health Protection Rules (TAHPR) and EPA regulation 40 CFR 61, Subpart M, The National Emission Standards for Hazardous Air Pollutants (NESHAP) requires that an asbestos survey be performed prior to renovation or demolition activities.

The objective of the LBP sampling was to identify accessible LBP on the interior and exterior of the Building 1654. The LBP sampling was limited to readily observable and accessible surfaces. Based on information provided by the client, the building is proposed for renovation.

Asbestos Survey and Lead-Based Paint Sampling NASJRB ■ Building 1654 ■ Fort Worth, Texas April 18, 2017 ■ Terracon Project No. 95167571

Responsive ■ Resourceful ■ Reliable 2

Regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than 0.5% of lead by weight for buildings that meet the definition of target housing. The Occupational Safety and Health Administration (OSHA) define LBP as a paint which contains lead, regardless of the concentration. Due to the nature of the site, the OSHA regulations will apply to the construction and/or demolition activities, since the site does not meet the definition of a child occupied facility or target housing.

2.0 SITE DESCRIPTION

Building 1654 is a single-story structure that measures approximately 26,300 square feet. The exteriors walls consist of textured cementitious wall panels and textured brick.

The building has a pitched membrane roof over an existing tar and gravel roof on a metal deck.

The interior walls consist of textured drywall, ceramic tile on drywall, and unfinished concrete masonry unit (CMU) block. The floors consist of carpet, ceramic floor tile, and vinyl floor tile on a concrete substrate. The ceilings consist of a lay-in ceiling tile system suspended from the metal deck. No fireproofing was observed on the metal deck on the day of the survey

3.0 ASBESTOS FIELD ACTIVITIES

The asbestos survey and LBP sampling was conducted by Mr. Chad Champagne, a

Texas Department of State Health Services (TDSHS) licensed Asbestos Inspector

(License No. 60-3112). Copies of licenses and certifications are attached in Appendix E.

The asbestos survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, the Asbestos Hazard Emergency

Response Act (AHERA). A summary of survey activities is provided below.

3.1 Visual Assessment

Our survey activities began with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area consists of building materials that appear similar throughout in terms of color, texture, and date of application. The assessment was conducted throughout visually accessible areas of the building. Building materials identified as concrete, glass, wood, masonry, metal or rubber were not considered suspect ACM.

Responsive ■ Resourceful ■ Reliable 3

3.2 Physical Assessment

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.3 Asbestos Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. Sample team members collected bulk samples using wet methods as applicable to reduce the potential for fiber release.

Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

One hundred fifty-nine (159) bulk samples were collected from forty-seven (47) homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix A.

3.4 Sample Analysis

Suspect ACM samples were delivered under proper chain of custody to Cates

Laboratories, of Dallas, Texas, an accredited National Voluntary Laboratory

Accreditation Program (NVLAP) (Lab No. 200569-0) and TDSHS (License No. 30-0287) licensed laboratory for analysis by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA Method 600/R-93/116. The percentage of asbestos where applicable, was determined by microscopic visual estimation.

4.0 LEAD-BASED PAINT FIELD ACTIVITIES

4.1 Site Limitations

It should be noted that suspect LBP, other than those identified during the sampling, may exist within the building and/or on the building exterior that was inaccessible. If suspect

LBP is identified, those materials should be assumed to LBP until testing can be performed to determine if lead is present in the paint.

4.2 Methodology and Analysis

The LBP sampling was conducted by Mr. Chad Champagne, a TDSHS certified Lead Risk

Assessor (Certification No. 2071012). The LBP sampling was conducted by scraping

Responsive ■ Resourceful ■ Reliable 4 approximately one square inch of paint from the supporting substrate. Ten (10) samples were submitted to Environmental Hazards Services, L.L.C. of Richmond, VA, a National

Environmental Laboratory Accreditation Program (NELAP) certified (Certificate No.

T104704248-11-3) and AIHA accredited (Lab ID: 100420) accredited laboratory. The analysis was performed by Flame Atomic Absorption Spectrophotometry, EPA method

(EPA SW846 7000B). The limit of detection (LOD) for this analytical method ranged from

<37 ppm to <3400 ppm based on the weight of the sample. Sample results reported below the LOD may contain lead at a concentration below the analytically defined LOD.

A summary of the lead based paint samples and analysis is included in Appendix D.

No materials were assumed to be LBP. Any inaccessible areas that contain painted surfaces should be tested when access permits or should be assumed to be positive for

Lead-Based Paint.

5.0 REGULATORY OVERVIEW

5.1 Asbestos Regulations

The State of Texas has established the TAHPR which requires any asbestos-related activity to be performed by an individual licensed by the State of Texas, through the

TDSHS. An asbestos related activity consists of the disturbance (whether intentional or unintentional), removal, encapsulation, or enclosure of asbestos, including preparations or final clearance, the performance of asbestos surveys, the development of management plans and response actions, asbestos project design, the collection or analysis of asbestos samples, monitoring for airborne asbestos, bidding for a contract for any of these activities, or any other activity required to be licensed under TAHPR.

Abatement must be performed by a State of Texas licensed asbestos abatement contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be conducted during the abatement activities.

The asbestos NESHAP (40 CFR Part 61 Subpart M) regulates asbestos fiber emission and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity.

Under NESHAP, asbestos containing building materials are classified as either friable, Category I nonfriable or Category II nonfriable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure.

Category I nonfriable ACM includes packing, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II nonfriable ACM are any materials other than Category I materials that contain more than 1% asbestos.

Responsive ■ Resourceful ■ Reliable 5

Friable ACM, Category I and II nonfriable ACM in poor condition and has become friable or which will be subject to drilling, sanding, grinding, cutting, or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated ACM (RACM). The TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any asbestos-containing material (ACM) in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least 10 working days prior to the commencement of asbestos abatement or demolition activities. Removal of RACM must be conducted by a State of Texas licensed asbestos contractor. In addition, third party air monitoring must be performed during the abatement.

The Occupational Safety and Health Administration (OSHA) Asbestos standard for the construction industry (29 CFR 1926.1101) regulates workplace exposure to asbestos.

The OSHA standard requires employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc).

The OSHA standard classifies construction and maintenance activities which could disturb

ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States that administer their own federally approved state OSHA programs may require other precautions.

5.2 Lead-Based Paint Regulations

The State of Texas has established the Texas Environmental Lead Reduction Rules

(TELRR) to establish the means to control and minimize public exposure to lead by regulating lead-based paint activities in target housing and child-occupied facilities. The

TELRR contains procedures and requirements for the accreditation of lead training providers, procedures and requirements for the certification of individuals and firms engaged in lead-based paint activities and standards for performing such activities in target housing and child-occupied facilities. The TELRR also requires that all lead-based paint activities in target housing and child-occupied facilities be performed by certified individuals.

As a point of reference, regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than

0.5% of lead by weight for buildings that meet the definition of target housing. OSHA, however, defines LBP as a paint which contains lead, regardless of the concentration.

The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint.

OSHA considers paint containing any level of lead above the analytical method detection

Responsive ■ Resourceful ■ Reliable 6 limit a potential hazard which should be communicated to any employees or contractors who may disturb the materials in the course of their assigned work.

6.0 FINDINGS AND RECOMMENDATIONS

Asbestos

Based on the results of the laboratory analyses, asbestos was confirmed in the following materials:

Carpet mastic

Floor tile with mastic under carpet (2 types)

Exterior window caulk

Exterior soffit

The identified asbestos containing materials were assessed to be nonfriable and in good condition on the day of the survey. The identified asbestos containing materials must be abated prior to renovation activities if those materials will potentially be disturbed.

The asbestos abatement must be performed by a State of Texas licensed asbestos contractor in accordance with a project design prepared by a State of Texas licensed asbestos consultant. In addition, third party air monitoring must be performed during the abatement.

It is important to note the TAHPR and NESHAP require that written notification be submitted before beginning renovation projects which include the disturbance of any

ACM in a building or facility, or before the demolition of a building or facility, even when no asbestos is present. This written notification must be provided to the TDSHS at least ten (10) working days prior to the commencement of asbestos abatement or demolition activities. These activities must be performed in accordance with the current TDSHS, EPA, and OSHA guidelines.

Lead-Based Paint

A total of ten (10) paint chip samples were collected and none of the samples contained lead above the HUD standard of 5,000 ppm, which would render the material “Lead-

Containing” (considered a potential hazard by OSHA). A summary of the components tested, location of the measurement, and results are provided in Appendix D.

Any renovation activities conducted in Building 1654 would be subject to OSHA regulations (29 CFR 1926.62 – Lead Exposure in Construction). The OSHA regulation defines specific training requirements, engineering controls and working practices for construction personnel subject to this standard.

Responsive ■ Resourceful ■ Reliable 7

It is unlikely component removal and/or painting activities planned would present a lead hazard to personnel, however, it is recommended that contracting personnel who may disturb the paint as part of the planned renovations should be made aware of the lead content in the materials so that they may exercise proper OSHA procedures for personnel protection or possibly employ protective procedures when working with the materials.

Compliance with applicable OSHA lead regulations is the responsibility of the contractor performing the work and it is recommended that they be required to communicate potential lead hazards to their workforce and utilize lead-safe work practices such as outlined in the EPA Renovation, Repair, and Painting Final Rule (40 CFR 745) or applicable portions of the Structural Steel Painting Council (SSPC) Guidelines. It is further recommended that activities such as flame/torch dismantling, dry sanding and/or dry grinding of any components with lead-containing materials applied should be prohibited as part of any repair, renovation or demolition activity.

7.0 GENERAL COMMENTS

This asbestos survey/LBP sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Blair

Remy Architects for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

APPENDIX A

CONFIRMED ASBESTOS-CONTAINING MATERIALS

Naval Air Station Joint Reserve Base (NASJRB)

Building 1654

Sample No.

Material Location (Area) Friable/

Nonfriable Assessed Condition

Estimated Quantity

32, 33, 34 Carpet Mastic (Brown) associated with Northwest Renovation Area

Rooms 113, 113.1, 113.4, 113,5, Corridor 113.2, and Adjacent

Closed 113.3 Nonfriable Good

1,870 square feet

64, 65, 66 Floor Tile under Carpet with Mastic (Black) associated with East Addition

Rooms 147, 148, 154, 156, 157, 159, 160, 161, 162, 163, 165, 166, 167, 174, 175, 176, 177, 178, 179, 179.1, 180, and Corridor 115

Nonfriable Good 5,830 square feet

122, 123, Floor Tile under Carpet with Mastic (Black) associated with Main Building

Rooms 104, 105, 106, 106.1, 107, 108, 109, 110, 111, 120, 121, 122, 123, 140, 141, 142, 143, 144, 145, 146, 149, 149.1, 181, 182, 183, 184, 185, 186, 187, 188, 189, 190, 191, 192, 193, 194, and 195

Nonfriable Good 8,370 square feet

148, 149, Exterior Window Caulk (Gray) South Windows Nonfriable Good 240 linear feet

(6 square feet)

154, 155, Exterior Soffit (Gray) Perimeter of Building Exterior Nonfriable Good 1,550 square feet

APPENDIX B

ASBESTOS SURVEY SAMPLE SUMMARY

Naval Air Station Joint Reserve Base (NASJRB)

Building 1654

Material Asbestos Containing Sample Numbers

2’ x 2’ Ceiling Tile (White, Pinholes, Rough)

No 1, 2, 3

2’ x 4’ Ceiling Tile (White, Pinholes, Rough)

No 4, 5, 6

2’ x 2’ Ceiling Tile (White, Heavy Rough) associated with Northwest Renovated Area

No 7, 8, 9

Wall Texture (White, Orange Peel) with Drywall and Joint Compound

No 10, 11, 12, 13, 14, 15, 16

4” x 4” Ceramic Wall Tile (White) with Grout (Gray) and Thinset (Tan)

No 17, 18, 19

Cove Base Mastic (Tan) No 20, 21, 22

2’ x 2’ Ceiling Tile (White, Pinholes and Pockmarks)

No 23, 24, 25

Thermal System Insulation Mastic (White)

No 26, 27, 28

Carpet Mastic (Green) associated with Blue Carpet Squares

No 29, 30, 31

Carpet Mastic (Brown) associated with Northwest Renovation Area

Yes 32, 33, 34

24” x 24” Ceramic Floor Tile (Gray, Mottled) with Grout (Gray) and Thinset (White)

No 35, 36, 37

2” x 2” Ceramic Floor Tile (Gray) with Grout (Gray) and Thinset (Tan)

No 38, 39, 40

12” x 12” Ceramic Floor Tile (Tan and Gray, Mottled) with Grout (Gray) and Thinset (White)

No 41, 42, 43

12” x 12” Ceramic Floor Tile (Brown, Mottled) with Grout (Brown) and Thinset (Tan)

No 44, 45, 46

Sink Undercoating (White) No 47, 48, 49

Wall Texture (White, Semi-Smooth) with Drywall and Joint Compound associated with Northwest Renovation

No 50, 51, 52, 53, 54

12” x 12” Vinyl Floor Tile (White with Blue and Gray Streaks) with Mastic (Brown)

No 55, 56, 57

Wall Covering (Gray) No 58, 59, 60

Interior Building Caulk (White) associated with Plumbing Fixtures

No 61, 62, 63

Floor Tile under Carpet with Mastic (Black) associated with East Addition

Yes 64, 65, 66

Interior Window Caulk (White) No 67, 68, 69

Interior Door Caulk (White) associated with Office Doors

No 70, 71, 72

Interior Door Caulk (White) associated with Entry Doors

No 73, 74, 75

Interior Door Caulk (Black) associated with Corridor Security Doors

No 76, 77, 78

Wall Texture (White, Semi-Smooth) with Drywall and Joint Compound

No 79, 80, 81, 82, 83

Carpet Mastic (Green) associated with Command Post

No 84, 85, 86

Duct Mastic (White) No 87, 88, 89

Duct Mastic (Gray) No 90, 91, 91

Thermal System Pipe Insulation associated with Mechanical Room

No 93, 94, 95

Thermal System Pipe Insulation Fittings associated with Mechanical Room

No 96, 97, 98

Wall Texture (White, Orange Peel) with Drywall and Joint Compound associated with East Addition

No 99, 100, 101, 102, Cove Base Mastic (Tan) associated with East Addition

No 104, 105, 106

Floor Tile under Carpet with Mastic (Yellow)

No 107, 108, 109

Deck Insulation (Yellow) No 110, 111, 112

Interior Building Caulk associated with Janitor Sink

No 113, 114, 115

Thermal System Pipe Insulation (Brown)

No 116, 117, 118

Floor Tile under Carpet (Blue) with Mastic (Yellow) associated with Break Room

No 119, 120, 121

Floor Tile under Carpet with Mastic (Black) associated with Main Building

Yes 122, 123, 124

Exterior Building Texture (Tan) No 125, 126, 127, 128, 129, 130, 131

Exterior Building Texture (White) associated with Brick

No 132, 133, 134, 135, 136, 137, 138

Expansion Joint Caulk (Tan) No 139, 140, 141

Exterior Door/Window Caulk (Tan) No 142, 143, 144

Exterior Door Caulk (White) No 145, 146, 147

Exterior Window Caulk (Gray) Yes 148, 149, 150

Expansion Joint Caulk (White) No 151, 152, 153

Exterior Soffit (Gray) Yes 154, 155, 156

Roof Membrane No 157, 158, 159

APPENDIX C

ASBESTOS LABORATORY ANALYTICAL REPORTS

PLM REPORT SUMMARY

Cates Laboratories NVLAP Lab No. 200569-0

1339 Motor Circle TDSHS License No. 30-0287

Dallas, Texas 75207 (214) 920-5006

Client: Terracon Lab Job No.: PLM-14221

Project: NASJRB - Building 1654 Set No.: 21319

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 1 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Lab

Sample No.

Client

Field I.D.

Sample Description/Location Asbestos Content

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced except in full.

CL527032

2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, East

None Detected

CL527033

2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, Center

CL527034

2' X 2' Ceiling Tile (white, pinholes, rough) - Corridor 127, West

CL527035

2' X 4' Ceiling Tile (white, pinholes, rough) - Corridor 115

CL527036

2' X 4' Ceiling Tile (white, pinholes, rough) - Room 160

CL527037

2' X 4' Ceiling Tile (white, pinholes, rough) - Room 161

CL527038

2' X 2' Ceiling Tile (white, heavy rough) associated w/Post Renovation

Areas - Room 113.5

CL527039

Areas - Room 113

CL527040

Areas - Room 113.1

CL527041

Wall Texture (white, orange peel) w/Drywall & Joint Compound -

Corridor 127

None Detected - Paint Texture

None Detected - Joint Tape

None Detected - Joint Compound

None Detected - Paper

None Detected - Wallboard Material

CL527042

Wall Texture (white, orange peel) w/Drywall & Joint Compound - Room

None Detected - Joint Compound

CL527043

Vestibule 126

None Detected - Joint Compound

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 2 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527044

None Detected - Joint Compound

CL527045

104, Lobby

None Detected - Joint Compound

CL527046

Corridor 127, West

None Detected - Joint Compound

CL527047

None Detected - Joint Compound

CL527048

4" X 4" Ceramic Wall Tile (white) w/Grout (gray) & Thinset (tan) -

Room 101

None Detected - Ceramic Tile

None Detected - Grout

None Detected - Thinset

CL527049

CL527050

CL527051

Cove Base Mastic (tan) - Room 160

CL527052

Cove Base Mastic (tan) - Room 159

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 3 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527053

Cove Base Mastic (tan) - Room 154.1

CL527054

2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 101

CL527055

2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 101

CL527056

2' X 2' Ceiling Tile (white, pinholes & pockmarks) - Restroom 102

CL527057

Thermal System Insulation Mastic (white) - Room 160

None Detected - White Mastic

None Detected - Wrap

None Detected - Insulation

CL527058

Thermal System Insulation Mastic (white) - Room 151

CL527059

Thermal System Insulation Mastic (white) - Restroom 101

CL527060

Carpet Mastic (green) associated w/Blue Carpet Squares - Auditorium

CL527061

CL527062

CL527063

Carpet Mastic (brown) associated w/Northwest Renovation Area - Room

113.1, Closet

5% Chrysotile

CL527064

113, Closet

CL527065

113.5

CL527066

24" X 24" Ceramic Floor Tile (gray, mottled) w/Grout (gray) & Thinset

(white) - Corridor 127, East

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 4 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527067

(white) - Corridor 127, Center

CL527068

(white) - Corridor 127, West

CL527069

2" X 2" Ceramic Floor Tile (gray) w/Grout (gray) & Thinset (tan) -

Restroom 101

None Detected - Grout/Thinset

CL527070

CL527071

Restroom 102

CL527072

12" X 12" Ceramic Floor Tile (tan & gray, mottled) w/Grout (gray) &

Thinset (white) - Room 182

CL527073

Thinset (white) - Room 104, Lobby, East

CL527074

Thinset (white) - Room 104, Lobby, West

CL527075

12" X 12" Ceramic Floor Tile (brown, mottled) w/Grout (brown) &

Thinset (tan) - Room 125

CL527076

CL527077

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 5 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527078

Sink Undercoating (white) - Room 125

CL527079

CL527080

CL527081

Wall Texture (white, semi-smooth) w/Drywall & Joint Compound associated w/Northwest Renovation Area - Room 113

None Detected - Joint Compound

CL527082

associated w/Northwest Renovation Area - Room 113.1, Closet

None Detected - Joint Compound

CL527083

associated w/Northwest Renovation Area - Room 113, Closet

None Detected - Joint Compound

CL527084

associated w/Northwest Renovation Area - Room 113.4

None Detected - Joint Compound

CL527085

associated w/Northwest Renovation Area - Room 113.5

None Detected - Joint Compound

CL527086

12" X 12" Vinyl Floor Tile (white w/blue & gray streaks) w/Mastic

(brown) - Janitor's Closet 103

None Detected - Floor Tile

None Detected - Yellow Mastic

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 6 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527087

CL527088

CL527089

Wall Covering (gray) - Restroom 101

CL527090

CL527091

CL527092

Interior Building Caulk (white) associated w/Plumbing Fixtures -

CL527093

CL527094

CL527095

Floor Tile under Carpet w/Mastic (black) associated w/East Addition -

Room 160

5% Chrysotile - Floor Tile

5% Chrysotile - Black Mastic

CL527096

Corridor 115

CL527097

Room 157

CL527098

Interior Window Caulk (white) - Room 165

CL527099

Interior Window Caulk (white) - Room 183

CL527100

Interior Window Caulk (white) - Room 113.1

CL527101

Interior Door Caulk (white) associated w/Office Doors - Room 161, Entry

Door

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 7 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527102

Interior Door Caulk (white) associated w/Office Doors - Room 181, Entry

CL527103

Interior Door Caulk (white) associated w/Office Doors - Room 191, Entry

CL527104

Interior Door Caulk (white) associated w/Entry Doors - East Entry Door

CL527105

Interior Door Caulk (white) associated w/Entry Doors - North Entry Door

CL527106

Interior Door Caulk (white) associated w/Entry Doors - West Entry Door

CL527107

Interior Door Caulk (black) associated w/Corridor Security Door -

Corridor 124, Security Door

CL527108

Corridor 124, Security Door

CL527109

Command Center Corridor

CL527110

Wall Texture (white, semi-smooth) w/Drywall & Joint Compound -

Janitor's Closet 103

None Detected - Joint Compound

CL527111

None Detected - Joint Compound

CL527112

None Detected - Joint Compound

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 8 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527113

Mechanical Room 119

None Detected - Joint Compound

CL527114

None Detected - Joint Compound

CL527115

Carpet Mastic (green) associated w/Command Post - Room 138

CL527116

Carpet Mastic (green) associated w/Command Post - Room 139

CL527117

Carpet Mastic (green) associated w/Command Post - Room 132

CL527118

Duct Mastic (white) - Corridor adjacent to North Entry

CL527119

CL527120

CL527121

Duct Mastic (gray) - Corridor 127, East

CL527122

Duct Mastic (gray) - Room 160

CL527123

Duct Mastic (gray) - Restroom 101

CL527124

Thermal System Pipe Insulation associated w/Mechanical Room -

CL527125

CL527126

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 9 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527127

Thermal System Pipe Insulation Fittings associated w/Mechanical Room -

CL527128

CL527129

CL527130

Wall Texture (white, orange peel) w/Drywall & Joint Compound associated w/East Addition - Corridor 115

None Detected - Joint Compound

CL527131

associated w/East Addition - Room 165

None Detected - Joint Compound

CL527132

associated w/East Addition - Room 162

None Detected - Joint Compound

CL527133

associated w/East Addition - Room 167

None Detected - Joint Compound

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 10 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527134

associated w/East Addition - Room 160

None Detected - Joint Compound

CL527135

Cove Base Mastic associated w/East Addition - Room 160

CL527136

Cove Base Mastic associated w/East Addition - Room 161

CL527137

Cove Base Mastic associated w/East Addition - Room 167

CL527138

Floor Tile under Carpet w/Mastic (yellow) - Room 170

CL527139

Floor Tile under Carpet w/Mastic (yellow) - Corridor 114

CL527140

Floor Tile under Carpet w/Mastic (yellow) - Room 179

CL527141

Deck Insulation (yellow) w/White Powder - Corridor 127, East

None Detected - Powder Material

CL527142

Deck Insulation (yellow) w/White Powder - Corridor 127, Center

CL527143

Deck Insulation (yellow) w/White Powder - Classroom 151

CL527144

Interior Building Caulk associated w/Janitor Sinks - Janitor's Closet 103

CL527145

CL527146

CL527147

Thermal System Pipe Insulation (brown) - Corridor 127, North

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 11 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527148

CL527149

CL527150

Floor Tile under Carpet (blue) w/Mastic (yellow) associated w/Break

Room - Break Room 154.1

CL527151

CL527152

CL527153

Floor Tile under Carpet w/Mastic (black) associated w/Main Building -

Room 181

CL527154

Room 104

CL527155

Room 123

CL527156

Exterior Building Texture (tan) - Southwest Corner

None Detected - Stucco

CL527157

Exterior Building Texture (tan) - North Exterior Wall

CL527158

Exterior Building Texture (tan) - North Exterior Wall

CL527159

Exterior Building Texture (tan) - Northeast Corner

CL527160

Exterior Building Texture (tan) - East Exterior Wall

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 12 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527161

Exterior Building Texture (tan) - East Exterior Wall

CL527162

Exterior Building Texture (tan) - Southeast Corner

CL527163

Exterior Building Texture (white) associated w/Brick - South Exterior

Wall, Southwest Corner

None Detected - Brick

CL527164

Wall, West

CL527165

Wall, Center

CL527166

Wall, Center

CL527167

Wall, East

CL527168

Wall, East

CL527169

Wall, Southeast Corner

CL527170

Expansion Joint Caulk (tan) - Southwest Corner

CL527171

Expansion Joint Caulk (tan) - Northwest Corner

CL527172

Expansion Joint Caulk (tan) - North Exterior Wall

CL527173

Exterior Door/Window Caulk (tan) - East Entry Doors

CL527174

Exterior Door/Window Caulk (tan) - Northeast Windows

CL527175

Exterior Door/Window Caulk (tan) - West Windows

CL527176

Exterior Door Caulk (white) - Command Post, Exterior Entry Door

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 13 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:

Client

These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by

CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced

CL527177

Exterior Door Caulk (white) - Room 123, Exterior Entry Door

CL527178

Exterior Door Caulk (white) - Mechanical Room 119, Exterior Entry

CL527179

Exterior Window Caulk (gray) - South Windows

3% Chrysotile

CL527180

CL527181

CL527182

Expansion Joint Caulk (white) - South Exterior Wall

CL527183

CL527184

CL527185

Exterior Soffit (gray) - Southeast Soffit

20% Chrysotile

CL527186

Exterior Soffit (gray) - Southwest Soffit

CL527187

Exterior Soffit (gray) - Southwest Soffit

CL527188

Roof Membrane - South Roof

None Detected - Roofing Membrane 1

None Detected - Roofing Membrane 2

None Detected - Roofing Insulation

None Detected - Roofing Foam

CL527189

Roof Membrane - Southeast Roof

None Detected - Roofing Membrane

None Detected - Roofing Tar

CL527190

Roof Membrane - North Roof

None Detected - Roofing Membrane 1

None Detected - Roofing Membrane 2

Project No: 95167571 Report Date: 4/5/2017

Identification: Asbestos, Bulk Sample Analysis Sample Date: 3/22-31/2017

Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)

EPA Method 600/R-93/116 Page 14 of 14

On 4/4/2017, one-hundred fifty-nine (159) bulk samples were submitted by Mr. Chad Champagne of Terracon for asbestos analysis by PLM/DS.

Copies of the lab data sheets are attached; additional information may be found therein.

STATEMENT OF LABORATORY ACCREDITATION

The samples were analyzed in general accordance with the procedures outlined in the Method for the

Determination of Asbestos in Bulk Building Materials, EPA/600/R-93/116 or the U.S. Environmental

Protection Agency method, under AHERA (EPA 600/M4-82-020), for the analysis of asbestos in building materials by polarized light microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Specific questions concerning bulk sample results shall be directed to the Laboratory Director.

Analyst:

Jessica Scott

Laboratory Director: John R. Cates, P.G.

Approved Signatory:

NVLAP LAB CODE 200569-0

APPENDIX D

Lead Based Paint Sample Results

Naval Air Station Joint Reserve Base (NASJRB)

Building 1654

Sample Number

Sample Location

Component Lead

Concentration

(ppm)

South Exterior

Wall White Paint on Metal Conduit <670

South Exterior

Wall Brown Paint on Metal Downspout <420

South Exterior

Wall White Paint on Brick Exterior Wall <37

East Exterior

Wall Tan Paint on Textured Exterior Wall 58

5 East Entry Brown Paint on Metal Guardrail <110

6 East Corridor Gray Paint on Metal Door Frame <1700

7 Room 160 White Paint on Drywall <46

8 Room 113 White Paint on Drywall <48

9 Room 113.5 White Paint on Metal Door Frame <38

South Exterior

Mechanical Room

Gray Paint on Metal Exterior Door <3400

APPENDIX E

LEAD-BASED PAINT ANALYTICAL LABORATORY DATA

Analysis Report

Client:

Project/Test Address:

Terracon - Ft. Worth

7469 Whitepine Rd

Telephone: 800.347.4010

Richmond, VA 23237

Environmental Hazards Services, L.L.C.

NASJRB; Building 1654; 1510 Chennault Ave; Fort Worth, Texas

Client Number:

45-5814

Fax Number:

817-268-8602Laboratory Results

Analyzed Date:

Client Sample Number

Lab Sample Number

Pb (ug/g) ppm

Lead Paint Chip

04/06/2017

04/05/2017

17-04-00433

Reported Date:

Received Date:

Report Number:

2501 E. Loop 820, North Ft. Worth, TX 76118

Narrative

ID

04/06/2017

Collection Location % Pb by Wt.

03/31/2017Collection Date:

117-04-00433-001 L03CONDUIT <670 <0.067

217-04-00433-002 L03DOWNSPOUT <420 <0.042

317-04-00433-003 WALL <37 <0.0037

417-04-00433-004 WALL 58 0.0058

517-04-00433-005 L03GUARDRAIL <110 <0.011

617-04-00433-006 L03DOOR <1700 <0.17

717-04-00433-007 L04WALL <46 <0.0046

817-04-00433-008 WALL <48 <0.0048

917-04-00433-009 L03DOOR FRAME <38 <0.0038

1017-04-00433-010 L03DOOR <3400 <0.34

Page 2of1

Report Number:

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: 17-04-00433

NASJRB; Building 1654; 1510 Chennault Ave; Fort Worth, Texas

45-5814

Collection LocationClient Sample Number

Lab Sample Number

% Pb by Wt.

Narrative

ID

Pb (ug/g) ppm

Missy Kanode

QA/QC Clerk

Analysis Method: EPA SW846 7000B

The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) for samples prepared by ASTM E-1979-12 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 3050B is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.

LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight

Reviewed By Authorized Signatory:

L03: Sample submitted was less than the…