2012_Reference_Drawings_-_Vehicle_maintenance_facility,_Building_920.pdf

PDF 110 KB Posted

Attached to
REPAIR STEEL ROOF B924
Solicitation number
FA667018B0002
Issued by

About this file

There were no questions formally submitted however, our technical experts would like to include the attached drawing for reference.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(F V

'-0

S

LO

P E

S

LO

P E

W

X

W

X

(FV)

6'-0" ± 4'-0" 2'-0"

(FV)

6'-0" ± 2'-0"

(FV)

4'-2 3/8" ±

N E

W V

E H

IC

LE

M A

IN

T

E N

A N

C E

B U

IL

D

IN

G

EXISTING 12"

CMU WALL

4 LINES OF EXISTING

BRIDGING EQUALLY

SPACED

S102

S102

TYP

TYP

S102

S102

S102

TYP @

BRIDGING

(FV)

10'-8" ±

(F V

9' -6

EXISTING CMU

WALL EXISTING 2x8 FRAMING

(TO BE FIELD VERIFIED)

RE: NOTE 2

S

LO

P E

E X

IS

T

4L

H

J O

IS

T

E X

IS

T

4L

H

J O

IS

T

E X

IS

T

4L

H

J O

IS

T

E X

IS

T

4L

H

J O

IS

T

EXIST ROOF

PENETRATION (TYP)

(F

IE

LD

V

E R

IF

Y

6"

WT6X8 (CUT TO MATCH SLOPE OF

EXISTING ROOF) SHIM AS REQUIRED

BELOW EACH FLUTE SO WT FITS SNUG

BELOW EXISTING METAL DECK.

1/8

1/8

EXISTING METAL DECK

3-12 3/16

STAGGERED

BEAM

RE: PLAN

(FV)

(FV)

EXISTING 16" BOND BEAM

EXISTING 8" BOND BEAM

EXISTING 12" CMU WALL

EXISTING L4x4 x CONT

EXISTING METAL DECK

L4x4x1/4 x CONT

BETWEEN BRIDGING

1/2" DIA ADHESIVE

ANCHORS @ 32" OC MAX

INTO GROUTED CELLS

WT6x8 (CUT TO MATCH SLOPE

OF EXISTING ROOF) RE: 4/S102

FOR ADDITIONAL INFORMATION

EXISTING METAL DECK

1/4

3/4"

2" (F

V

3"

SLOPE

T/BOND BEAM

ELEV = 18'-8" AFF

(FIELD VERIFY)

EXISTING L5x3 x CONT

(T Y

P

1/

2"

L4x4x1/4 x 1'-0" w/ (2) 3/4" DIA

ASTM A325-N BOLTS AND

(2) 3/4" DIA ADHESIVE

ANCHORS INTO CMU WALL

EXISTING 12" CMU WALL

REINF @ 32" OC

E Q

8" E Q

3/8" FULL DEPTH STIFFENER

PLATE AT BEAM CENTERLINE

MC12x31 x 6'-0" w/ (2) 3/4" DIA

ADHESIVE ANCHORS @ 32" OC INTO

CENTER OF GROUTED CELLS (2

ROWS OF 3 ANCHORS = 6 ANCHORS

TOTAL. CENTER MOST ANCHORS

SHALL BE LOCATED NO MORE THAN

16" FROM BEAM CENTERLINE)

6"

EXISTING 12" CMU WALL

EXISTING L4x4 x 1'-0"

SLOPED WT

RE: 4/S102

L2x2x1/4

EXISTING METAL

DECK

EXISTING JOIST

(TYP)

1/4" PLATE

(TYP)

L1 1/2x1 1/2x3/16

(TYP, UNO)

BEAM

RE: PLAN

EXISTING L1 1/2x1 1/2

BRIDGING3/16

TYP

RE: PLAN RE: PLAN RE: PLAN RE: PLAN RE: PLAN

RE: 3/S310 FOR NEW L4x4

DECK SUPPORT ANGLE

GABRIEL A. SERNA

OF TEXASSTATE

ALNOISSE

F O

R P

ENGIN

E

E R

NSEDECIL

99793

Sheet

SHEET

IDENTIFICATION

of

Louisville District

P R

O

JE

C T

N U

M B

E R

: R V

K Q

2-

Ja co bs E ng in ee rin g G ro up

In c.

T ex as R eg is te re d E ng in ee rin g F irm F

-2

M ai n

S tr ee t

F or t W or th , T

X

A N

S I D

A S

S H

O W

N

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S B

M T

B Y

P

LO

T S

C A

LE

P

LO

T D

A T

E

LO

U

IS

V

IL

LE

D

IS

T R

IC

T

LO

U

IS

V

IL

LE

, K E

N T

U C

K Y

D

E C

E M

B E

R , 2

X X

X X

R . B

E S

A N

C O

N

U .S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

US Army Corps of Engineers ®

1 2 3 4 5

D

C

B

A

N

IA

G A

R A

F A

LL

S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K V

E H

IC

LE

M A

IN

TE

N A

N C

E F

A C

IL

IT

Y

B U

IL

D

IN

G

B

A

D D

IT

IO

N F:

\A ct ive P ro je ct s\C

O E_

Lo ui sv ille

D ist ric t\F

DW

D9

0-

NF

AR

S Ve hi cle

M ai nt en an ce

Fa cil ity

*** VALUE ENGINEERING - IT PAYS ***

*** SAFETY PAYS ***

CE

RT

IF

IE

D

FI

NA

L

/2

9/

4:

:1

P

M

S102

E X

IS

T

IN

G

B U

IL

D

IN

G

R O

O F

F R

A M

IN

G

A N

D S

E C

T

IO

N S

1/8" = 1'-0"S102 S102

3/4" = 1'-0"S102 S102

3/4" = 1'-0"S102 S102

3/4" = 1'-0"S102 S102

3/4" = 1'-0"S102 S102

NOTES:

1. FIELD VERIFY ALL EXISTING CONDITIONS AS NOTED AND NOTIFY ENGINEER OF ANY DISCREPANCIES

PRIOR TO PROCEEDING WITH ANY PHASE OF WORK.

2. VERIFY SIZE, SPACING, SPECIES AND GRADE OF EXISTING WOOD FRAMING. IF EXISTING MEMBERS ARE

NOT AS INDICATED BELOW, NOTIFY ENGINEER.

A. PLYWOOD DECK - 1/2" MINIMUM THICKNESS WITH FACE GRAIN PERPENDICULAR TO SUPPORT.

B. ROOF JOISTS - NO. 2 - DOUGLAS FIR LARCH - 2x8 AT 16" OC.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

71 29

File details come from the government source that posted it.