SITE_VISIT_QUESTIONS.docx

DOCX document 23 KB Posted

Attached to
Firing Range Cleaning Federal contract opportunity
Solicitation number
FA6670-14-R-0005
Issued by
Department of the Air Force Reserve Command

About this file

SITE VISIT QUESTIONS dated 16 June 14 in 1 page

View the file

Other files for this federal contract opportunity

Other files attached to Firing Range Cleaning, newest first.
File Type Posted
QUESTIONS.docx DOCX document
U.S_Small_Business_Administration_Size_Standards_Exception.pdf PDF
DSC00045.JPG JPG image
DSC00047.JPG JPG image
DSC00054.JPG JPG image
DSC00052.JPG JPG image
DSC00050.JPG JPG image
DSC00048.JPG JPG image
DSC00053.JPG JPG image
DSC00049.JPG JPG image
DSC00055.JPG JPG image
QUESTIONS_AND_ANSWERS_________________________________5_June_2014.docx DOCX document
DSC00046.JPG JPG image
DSC00056.JPG JPG image
DSC00045_(1).JPG JPG image
DSC00051.JPG JPG image
Wage_Determination.pdf PDF
FA6670-14-R-0005.pdf PDF
STATEMENT_OF_OBJECTIVE_B-427_Small_Arms_Range_FY14_Cleaning_Services.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SITE VISIT QUESTIONS/ANSWERS 16 JULY 2014

Regarding questions posed at this morning's walk-through for the range cleaning project:

1. Distance from the outside of the metal legs (closest to the walkway area) supporting the bullet trap conveyor belt system to a point 3-1/2" above the floor level at the sloped bullet-trap ramp is 23'-0". Measurement made by laser rangefinder.

2. "Spun-fiber" acoustical panels behind shooting positions have been identified by the installing contractor as "Tectum Finalé Panels". These are cementitious aspen wood fiber panels. Per the manufacturer, these panels "should be prevented from coming into contact with water if at all possible." The wood binder is water-based, so water may draw or pull the binder out. Otherwise, the panels may also become stained. Given these adverse reactions, the Statement of Objective is hereby modified to specify only dry HEPA-vacuuming of all surfaces covered with acoustic fiber panels. They will not be damp-mopped or damp-wiped with water/TSP solution or otherwise wetted. Panels will be masked or covered with a waterproof barrier if nearby surfaces are to be sprayed or wetted to prevent them from becoming wet.