QUESTIONS.docx

DOCX document 23 KB Posted

Attached to
Firing Range Cleaning Federal contract opportunity
Solicitation number
FA6670-14-R-0005
Issued by
Department of the Air Force Reserve Command

About this file

QUESTIONS/ANSWERS SITE VISIT 2 dated 18 June 14 in 1 page

View the file

Other files for this federal contract opportunity

Other files attached to Firing Range Cleaning, newest first.
File Type Posted
SITE_VISIT_QUESTIONS.docx DOCX document
U.S_Small_Business_Administration_Size_Standards_Exception.pdf PDF
DSC00050.JPG JPG image
DSC00048.JPG JPG image
DSC00045.JPG JPG image
DSC00047.JPG JPG image
DSC00054.JPG JPG image
DSC00052.JPG JPG image
DSC00045_(1).JPG JPG image
DSC00051.JPG JPG image
DSC00053.JPG JPG image
DSC00049.JPG JPG image
DSC00055.JPG JPG image
QUESTIONS_AND_ANSWERS_________________________________5_June_2014.docx DOCX document
DSC00046.JPG JPG image
DSC00056.JPG JPG image
Wage_Determination.pdf PDF
FA6670-14-R-0005.pdf PDF
STATEMENT_OF_OBJECTIVE_B-427_Small_Arms_Range_FY14_Cleaning_Services.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUESTIONS/ANSWERS SITE VISIT #2

QUESTION: Contractor supplied equipment. Does the contractor have to provide explosion proof equipment (Wet Vac’s/Dry Vacs) inside the firing range?

ANSWER: In the Statement of Objective, under Paragraph 9, "Government Furnished Items:", and specifically in paragraph 9.2 it is stated that "the Contractor may choose to provide their own explosion-proof HEPA vacuum(s) with equivalent performance to the government's explosion-proof HEPA vacuum unit, in any amount desired." The Contractor may choose not to provide any additional vacuum equipment, and use just the single government-provided Ruwac unit at no cost. This vacuum meets all the contract-specified requirements. It is not a "wet" vacuum, however, and will not be used as one. Use of a single vacuum may be considered a limiting factor, as we are talking about a large area. Should a Contractor desire to use more than one HEPA vacuum to perform the "dry" portion of this work, it will be of "explosion-proof" construction and equivalent in performance to the Ruwac, and will be inspected by 914 AW environmental personnel to ensure it complies with this requirement. "Wet" vacuums used to collect water/TSP soap solution or rinse water do not have to be explosion-proof, or even be HEPA-filter equipped, the reason being that dry-HEPA vacuuming with an explosion-proof unit(s) has already removed the vast majority of unexpended propellant (along with the leaded dust) that was originally present. Chances of any remaining unexpended propellant being inadvertently ignited when wet is negligible. Likewise, the remaining wet leaded dust or unexpended propellant do not pose the same inhalation hazards dry versions in much larger quantities of the same present.