Diagram_3.pdf
PDF 205 KB Posted
- Attached to
- Air Conditioning Unit Federal contract opportunity
- Solicitation number
- FA5587-16-Q-0032
About this file
Diagram 3
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 16-Q-0032_HVAC_Solicitation.pdf | ||
| Diagram_5.pdf | ||
| 16-Q-0032_HVAC_Solicitation.pdf | ||
| SITE_VISIT_QUESTIONS.pdf | ||
| 16-Q-0032_HVAC_Solicitation.pdf | ||
| Diagram_2.pdf | ||
| 16-Q-0032_HVAC_Combo.pdf | ||
| SOW_bldg_439_ac_system_replacement.pdf | ||
| Diagram_4.pdf | ||
| Diagram_1.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTES
1. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH ALL RELEVANT
ARCHITECTS AND ENGINEERS
DRAWINGS,DETAILS AND SPECIFICATIONS.
HTG
CT
VT
HWS
F&R
SV
IV
NRV
DRV
DOC
STR
DCV
MWS
DPS
P
T
ST
HL
ST
SC
IMM
HTR
AAV
PRV
LSV
CV
LEGEND
HEATING
CONSTANT TEMPERATURE
VARIABLE TEMPERATURE
HOT WATER SWRVICE
FLOW & RETURN
SAFETY VALVE
ISOLATING VALVE
NON-RETURN VALVE
DOUBLE REGULATING VALVE
DRAIN OFF COCK
STRAINER
DOUBLE CHECK VALVE
MAINS WATER SERVICE
DIFFERENTIAL PRESSURE SWITCH
PRESSURE GAUGE
TEMPERATURE GAUGE
THERMOSTAT
HIGH LIMIT THERMOSTAT
STOP COCK
IMMERSION HEATER
AUTOMATIC AIR VENT
PRESSURE REDUCING VALVE
LOCK SHIELD VALVE
CHECK VALVE
BOILER N°2
4 2
P2
P
DPS
P
BOILER N°1
3 1
P1
P
P
DPS
AHU HTG COIL
CONNECTIONS
AHU FROST COIL
CONNECTIONS
92 91
84 90
DPS
P
P
P1
T
ST
P2
P
P
DPS
HLST
DPS
P
P
P1
T
ST
P2
P
P
DPS
11 Ltr
DOSSING
POT
T
ST
T
ST
T
ST
200 Ltr
VESSEL
PRESS
UNIT
QFVS
P
EXP
VESSEL
72 71
ST
P
P
ACCESS
PANEL
ST
HWS
CHLORIFIER
H L
S T
DPS
HWS
ZONE
22Ø
VT HTGZONE
40Ø
40Ø
40Ø
15Ø
22Ø
35Ø
40Ø
ZONE
QFILL
CT HTG
ZONE
ZONE
ZONE
ZONE
HWS
HWS
CT HTG
VT HTG
35Ø
106 35Ø
54Ø
22Ø
40Ø
40Ø
35Ø
HWSZONE
ZONE
ZONE
ZONE
MWS
MWS
HWS
ZONE
ZONE
ZONE
VT HTG
VT HTG
HWS
HWS
IV
15Ø83
40Ø
40Ø
22Ø
42Ø
40Ø
15Ø
40Ø
40Ø
MWS
IV
ZONE
ZONE
ZONE
VT HTG
VT HTG
MWS
CTRL
DOC
IV
STR
CT HTG
CT HTG
CT HTG
CT HTG
40Ø
15Ø
40Ø
40Ø
40Ø
40Ø
40Ø
40Ø
STR
IV
IV
CTRL
DOC
CT HTG
CT HTG
CT HTG
CT HTG
DRV
IV
IV
CT HTG
CT HTG
CT HTG
CT HTG
SERVICEREF
22Ø
15Ø
SIZE
IV
IV
TYPE
HWS
HWS
SERVING
IV
FLOW
15Ø20AAV
CT HTG
15Ø
IV CT HTG
40Ø
15Ø
22Ø
25Ø
HWS
HWS
HWS
DOC
IV
SV
15Ø
40Ø
40Ø
40Ø
54Ø
54Ø
15Ø
22Ø
DOC CT HTG
CT HTG
CT HTG
CT HTG
CTRL
STR
DRV
HWS
HWS
HWS
HWS
CV
IV
DOC
LSV
67Ø
15Ø
67Ø
67Ø
67Ø
15Ø
67Ø
15Ø
STR
MWS
MWS
MWS
MWS
MWS
DOC
IV
PRV
DCV
MWS
MWS
MWS
IV
SC
IV
VT HTG
50Ø
3PORT
DRV
50Ø
50Ø
50Ø VT HTG
VT HTG
VT HTGIV
IV
DOC
CTRL
15Ø
50Ø
50Ø
15Ø
15Ø
15Ø
65Ø
15Ø
IV CT HTG
CT HTG
VT HTG
VT HTG
IV
CT HTG
CT HTG
CT HTG
CT HTG
IV
IV
IV
IV
DOC
NRV
NRV
65Ø24
65Ø
65Ø
65Ø
65Ø
15Ø
15Ø
15Ø
IV CT HTG
CT HTG
CT HTG
CT HTG
CT HTG
IV
IV
INLET
RETURNIV
IV
IV
VT HTG
50Ø43
STR VT HTG52
65Ø
15Ø
15Ø
65Ø
65Ø
15Ø
50Ø
50Ø
STR CT HTG
CT HTG
CT HTG
CT HTG
IV
DOC
IV
CT HTG
CT HTG
VT HTG
DRV
DOC
IV
15Ø
50Ø
15Ø
50Ø
15Ø
15Ø
15Ø
50Ø
VT HTG
VT HTG
VT HTG
VT HTG
DOC
DRV
IV
IV
VT HTG
VT HTG
VT HTG
VT HTG
IV
IV
IV
IV
TYPEREF
50Ø
50Ø
SIZE SERVICE
VT HTG
VT HTG
NRV
NRV
SERVING
*IV
80Ø
*80Ø12 NRV
DOC
DOC
AAV
15Ø
15Ø
80Ø
15Ø
80Ø
OIL
OILIV
IV
CT HTG
IV
IV *
NRV
15Ø
80Ø
15Ø
15Ø
25Ø
25Ø
15Ø
80Ø
IV *
IV
IV
SV
SV
IV
IV
TYPE
REF
80Ø
80Ø
SIZE SERVICE
*IV
IV *
SERVING
AS INSTALLED
File details come from the government source that posted it. Updated .