FA5000-19-Q-0010-U00009_-_Attachment_1_Pricing_Schedule.pdf
PDF 337 KB Posted
- Attached to
- ECU's Federal contract opportunity
- Solicitation number
- FA5000-19-Q-0010
About this file
Attachment 1, Pricing Schedule
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA5000-19-Q-0010-U00009_-_Amendment_Purpose-Description.pdf | ||
| FA5000-19-Q-0010-U00009_-_Combined_Synopsis-Solicitation.pdf | ||
| FA5000-19-Q-0010_-_Questions_and_Answers_Jan_19.pdf | ||
| Questions_Regarding_ECU.docx | DOCX document | |
| Attachment_1_Pricing_Schedule_V2.docx | DOCX document | |
| RFQ_-_Amendment_7.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| Attachment_1_Pricing_Schedule.docx | DOCX document | |
| Questions_Regarding_ECU.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| Attachment_1_Pricing_Schedule.docx | DOCX document | |
| Questions_Regarding_ECU.docx | DOCX document | |
| Questions_Regarding_SShelters.docx | DOCX document | |
| Attachment_1_Pricing_Schedule.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| Attachment_1_Pricing_Schedule.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| RFQ.docx | DOCX document | |
| RFQ_CO_Reviewed.docx | DOCX document | |
| Attachment_1_Pricing_Schedule.docx | DOCX document |
Show all 21
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 Pricing Schedule
Request for Quote# FA5000-19-Q-0010 Amendment 9
Company Name: Cage: DUNS:
Company Address:
Point of Contact: Email: Phone:
Date Submitted: Date Quote Expires:
CLIN Description QTY U/I Unit Price Extended Price
0001 5-Ton Environmental Control Units
(ECU) with the following MINIMUM specifications (unless stated otherwise):
- Operational Temperature
Range: -25 deg Fahrenheit to
125 deg Fahrenheit
- Cooling Capacity: 60,000 BTU per hour
- Heat Output Capacity: 50,000
BTU per hour
- Air Duct Diameter: 16” (exact)
- Power Requirements:
o 5 kW minimum- 11kW maximum o 208V (exact) o 50/60Hz, 3-phase
(exact)
- Color: Tan or subdued green
- Power Cable: 25 ft long
- Dimension: 52”w x 42”d x 33”l
(maximum)
- ECUs must be stackable and able to lock together
- Drain hose is required
- Operation and maintenance manual is required
- Standard commercial warranty
- Noise level: 85 dBA
(maximum)
10 EA
Delivery Date: 90 Days After Date of Award
By signing below the contractor is verifying the intent to comply will all clauses in the resulting contract.
Name of Individual authorized to sign for company Signature
File details come from the government source that posted it.