QA-21QC003 RANS Trailers.pdf
PDF 104 KB Posted
- Attached to
- RANS Trailers Federal contract opportunity
- Solicitation number
- FA489721QC003
About this file
This document contains a combined synopsis and solicitation from the Department of the Air Force seeking quotes for six mobile trailers to be used as mobile command centers. The solicitation requests firm fixed pricing for the trailers and lists required physical characteristics, electrical systems, and other specifications. Quotes are due no later than June 7, 2021 and should be submitted to two named individuals. The award will be made to the responsible vendor offering the best value based on price, meeting specifications, and past performance. The North American Industry Classification code for this project is 333924 and it is set aside 100% for small businesses with less than 750 employees.
The solicitation provides contact information for questions, system for award management registration requirements, and terms and conditions including various FAR and DFARS clauses that will apply to any resulting contract. The government intends to award without discussions and will apply standard commercial items procedures for this acquisition.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| QA-21QC003 Amendment 02.pdf | ||
| SPECS-RANS Trailers Amendment 01.pdf | ||
| QA-21QC003 RANS Trailers.pdf | ||
| ATTACH01-Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA489721QC003
Questions and Answers
366 RANS TRAILERS
25 May 2021
1) Insulation - Would the Government be interested in an insulated floor as well? This would greatly enhance the ability to localize the condition space within the trailer.
a. YES.
2) Could the Government provide the exact dimensions for the location of the 14” x 14” access doors?
a. YES, Front lower corner of trailer, forward of main door. The intent is to have the access door under the fold down table in the front to allow cables to connect to the work station.
3) What is the intended layout of the 22 recessed D-Rings?
a. 3 rows down the length of the trailer, (one in the center and one along each side wall). Spaced roughly 3 feet apart
4) Is the intent of the 47,000lb D-Rings to be able to support aerial lift of the trailer?
a. YES, we plan to air lift the trailers
5) Is there a specific ground clearance requirement, from Frame to Ground?
a. 19-20”
6) Would the Government accept a spray-in polyurea/polyurethane liner in lick of the tread plate floor and kickplate? Spray-in liners are becoming the standard in reinforced flooring as they are stringer and water/fluid resistant.
a. No.
7) 2. Requirements: document references qty. of “seven (6) mobile trailers” is it seven or six?
a. The total number of trailers is 6
8) 2.1 Physical Characteristics: Is the trailer to be Steel or Aluminum frame.
a. Aluminum is preferred to make the trailer lighter/steel is acceptable if the trailer stays within the weight GVWR
9) The specs require a screwless exterior side wall and skins. Aluminum top and Front (NO ABS or FIBERGLASS). Does the NO ABS or FIBERGLASS include the sides?
a. The NO ABS and Fiberglass does include the sides
10) 2.3.3 Trailer Jacks: Are the scissor style stabilizer jack’s manual or electric?
a. The trailer should have an electronic leveling system with the ability to manually override the stabilizer jacks
11) 2.4 Electrical Requirements: There is mention of “countertop receptacles” – I do not see anywhere they request a countertop.
a. The countertop receptacles are to be placed above the fold down work bench table on the front wall of the trailer
12) Are the Interior 48” LED lights 12V or 120V?
a. The LED lights should be 12 v so we can operate them with or without generator power applied (with batteries if needed)
13) Are the exterior “Load Lights” mounted on stainless brackets supposed to be extendable or fix mounted?
a. The exterior lights can be fixed mounted
14) There is mention of a “Passenger Side Awning” – is this 12V or 120V electric operated?
a. The awning can be either 12v or 120v (whichever is more efficient)
File details come from the government source that posted it. Updated .