QA-21QC003 RANS Trailers.pdf
PDF 75 KB Posted
- Attached to
- RANS Trailers Federal contract opportunity
- Solicitation number
- FA489721QC003
About this file
This solicitation requests quotes for the purchase and delivery of six trailers by the Department of the Air Force Air Combat Command. Quotes are due by 1:00 PM MST on June 7, 2021 and shall be submitted electronically to thomas.goolsby.1@us.af.mil and carmela.hornbeck@us.af.mil. Award is anticipated as a firm fixed-price contract. Evaluation will consider price, conformance to salient characteristics, and past performance. The trailers must meet specifications including insulated floors, access doors, D-rings for lifting, and a minimum 19-20 inch ground clearance. This is a 100% small business set-aside with a NAICS code of 333924 and size standard of 750 employees. The ship-to address is 266 Range Squadron at Mountain Home AFB in Idaho.
The solicitation includes standard federal acquisition clauses on representations and certifications, place of manufacture, terms and conditions, and prohibited sources. Additional provisions address past performance, subcontracting, small business, and transportation of supplies by sea. Questions are due by May 17, 2021 and shall be submitted electronically to the addresses indicated. Funds are not presently available and no award will be made until funding is in place.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| QA-21QC003 Amendment 02.pdf | ||
| SPECS-RANS Trailers Amendment 01.pdf | ||
| QA-21QC003 RANS Trailers.pdf | ||
| ATTACH01-Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FA489721QC003
Questions and Answers
366 RANS TRAILERS
25 May 2021
1) Insulation - Would the Government be interested in an insulated floor as well? This would greatly enhance the ability to localize the condition space within the trailer.
a. YES.
2) Could the Government provide the exact dimensions for the location of the 14” x 14” access doors?
a. YES, Front lower corner of trailer, forward of main door. The intent is to have the access door under the fold down table in the front to allow cables to connect to the work station.
3) What is the intended layout of the 22 recessed D-Rings?
a. 3 rows down the length of the trailer, (one in the center and one along each side wall). Spaced roughly 3 feet apart
4) Is the intent of the 47,000lb D-Rings to be able to support aerial lift of the trailer?
a. YES, we plan to air lift the trailers
5) Is there a specific ground clearance requirement, from Frame to Ground?
a. 19-20”
6) Would the Government accept a spray-in polyurea/polyurethane liner in lick of the tread plate floor and kickplate? Spray-in liners are becoming the standard in reinforced flooring as they are stringer and water/fluid resistant.
a. No.