Attachment_2_-_Gunfighter_Club_Floor_Plans.pdf

PDF 3 MB Posted

Attached to
Renovate Restrooms, Gunfighter Club
Solicitation number
FA4897-16-B-0013
Issued by

About this file

Attachment 2 - Gunfighter Club Floor Plans

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing Number:

A B C D E F G H

FILENAME: PLOT DATE: PLOT TIME:$FILENAME $PLOTDATE $PLOTTIME

SHEET of 4

PROJECT SCOPE

GENERAL NOTES

1.

2.

FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.

ALL WORK SHALL BE IN ACCORDANCE WITH UFC 1-200-01

GENERAL BUILDING REQUIREMENTS.

THE SCOPE OF WORK FOR THIS PROJECT IS TO RENOVATE

TWO EACH MEN'S AND WOMEN'S EXISTING RESTROOMS PER

ADA REQUIREMENTS, AND TO UPDATE THE FINISHES. THE

WORK REQUIRES UNDER-FLOOR PLUMBING WITHIN THE

BOUNDARIES OF WORK TO BE REMOVED AND REPLACED WITH

NEW. SOME INTERIOR WALLS MUST BE DEMOLISHED, AND

SOME NEW INTERIOR WALLS MUST BE CONSTRUCTED. PART

OF THE ADA UPGRADE WORK IS TO REPLACE ONE EXISTING

FREE-STANDING DRINKING FOUNTAIN IN THE MAIN CORRIDOR

WITH TWO HI-LO ADA APPROVED DRINKING FOUNTAINS. THE

WORK ALSO INCLUDES THE REPLACEMENT AND RELOCATION

OF A SERVICE SINK IN THE JANITOR ROOM. SOME EXISTING

FIRE SPRINKLERS MAY HAVE TO BE RELOCATED TO SERVE THE

NEW FLOOR PLAN LAYOUTS IN THE LOUNGE RESTROOMS. AS

OF THE DATE OF THIS DRAWING, SAMPLING AND TESTING FOR

ASBESTOS AND LEAD BASED PAINT IS UNDERWAY IN THIS

FACILITY. PROVIDE ASBESTOS AND/OR LEAD BASED PAINT

ABATEMENT IF INDICATED.

A-1.0

OVERALL FLOOR PLAN, GUNFIGHTER CLUB

3/32"=1'-0"

N

N

TRUE

NORTH

PLAN

NORTH

SEE DETAILS 1 & 2 SHT. A-2.0

SEE DETAIL 5 SHT. A-2.0

SEE DETAILS 3 & 4 SHT. A-2.0

O V

E R

A L L

F

L O

O R

P

L A

N

LINE INDICATES BOUNDARY OF WORK

FA4897-16-B-0013 ATTACHMENT 2 11 MAY 2016

Drawing Number:

A B C D E F G H

FILENAME: PLOT DATE: PLOT TIME:$FILENAME $PLOTDATE $PLOTTIME

SHEET of 4

RESTROOM DEMO PLAN KEY NOTES

GENERAL NOTES

A.

B.

C.

D.

E.

F.

G.

H.

J.

K.

L.

M.

N.

P.

R.

S.

T.

U.

V.

W.

X.

1.

2.

3.

FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.

ALL WORK SHALL BE IN ACCORDANCE WITH UFC 1-200-01 GENERAL BUILDING

REQUIREMENTS.

PROVIDE ASBESTOS AND/OR LEAD BASED PAINT ABATEMENT IF INDICATED.

REMOVE ALL PLUMBING FIXTURES. REMOVE SINK BASE CABINETS WHERE THEY

OCCUR.

REMOVE TOILET PARTITIONS AND URINAL SCREENS. PATCH AND REPAIR

MOUNTING HOLES AS REQUIRED.

REMOVE WALL-MOUNTED MIRRORS. PATCH AND REPAIR MOUNTING HOLES AS

REQUIRED.

REMOVE NON-BEARING FRAMED WALL FULL HEIGHT TO DIMENSION SHOWN.

REMOVE AFFECTED SWITHES, OUTLETS AND ASSOCIATED WIRING BACK TO

NEAREST JUNCTION BOX. PATCH AND REPAIR PLASTER CEILINGS AND ADJACENT

SURFACES TO MATCH SURROUNDING AREAS.

REMOVE ALL FLOOR TILE AND WALL TILE.

REMOVE CONCRETE FLOOR AND ALL EXISTING PLUMBING DRAIN PIPING BELOW

THE FLOOR AND IN THE WALLS.

REMOVE EXISTING FLOOR DRAINS.

REMOVE DOOR & FRAME.

REMOVE EXISTING CEILING MOUNTED RESTROOM EXHAUST FAN.

REMOVE TILE BACKING MATERIAL AT TILE WAINSCOT, ALL METALLIC

WAINSCOTING MATERIAL WHERE IT OCCURS, AND ALL GYP BOARD AND/OR

PLASTER AT WALLS FULL HEIGHT DOWN TO STUDS IN PREPARATION TO RECEIVE

WATERPROOF MEMBRANE, 5/8" CEMENTITIOUS BACKER UNITS AND FULL HEIGHT

WALL TILE.

REMOVE ALL SURFACE MOUNTED OVERHEAD AND WALL MOUNTED LIGHT

FIXTURES. DO NOT REMOVE CEILING RECESSED FIXTURE IN ENTRY OF WOMEN'S

MAIN RESTROOM.

REMOVE CEILING SURFACE MOUNTED JUNCTION BOXES AND CONDUIT WHERE

THEY OCCUR. PATCH, REPAIR AND FINISH PLASTER AND/OR GYP. BOARD

CEILINGS TO MATCH SURROUNDING SURFACES.

REMOVE CARPET AND WALL BASE.

REMOVE DRINKING FOUNTAIN, WATER SUPPLY, DRAIN LINE, AND POWER SUPPLY.

PATCH AND REPAIR ADJACENT FINISHES TO MATCH SURROUNDING SURFACES.

REMOVE WALL MOUNTED BABY CHANGING STATION. PATCH AND REPAIR

MOUNTING HOLES.

RETAIN AND PROTECT EXISTING CEILING MOUNTED SPEAKERS AND FIRE

SPRINKLERS FOR REUSE. SOME FIRE SPRINKLERS IN LOUNGE RESTROOMS MAY

HAVE TO BE RELOCATED TO ACCOMMODATE NEW FLOOR PLAN LAYOUTS.

SAW-CUT AND REMOVE A SECTION OF BRICK MASONRY UNIT WALL 7'-4" H x 4'-4 1/2"

W. SEE DETAIL 10/A-3.0.

SAW-CUT AND REMOVE THIS SECTION OF BRICK MASONRY WALL FULL HEIGHT

AND LENGTH TO DIMENSION SHOWN.

VERIFY OR PROVIDE METAL STUD, OR APPROVED EQUAL, KNEE BRACE FROM TOP

OF MASONRY WALL TO ROOF STRUCTURE FOR LATERAL SUPPORT.

REMOVE EXISTING ELECTRICAL OUTLETS, TYP.

FULLY PROTECT AND RETAIN EXISTING CARPET DURING DEMO & CONSTRUCTION.

THIS CARPET IS TO REMAIN AS PART OF THE COMPLETED PROJECT.

PROVIDE NEW DRAIN LINES BELOW FLOOR TO NEW PLUMBING FIXTURE

LOCATIONS. POUR NEW 4" CONCRETE FLOOR SLAB OVER 4" CRUSHED GRAVEL

OVER COMPACTED FILL. PREP NEW FLOOR SLAB TO RECEIVE NEW FLOOR FINISH.

CONSTRUCT 3 5/8" METAL STUD WALLS FROM FLOOR TO 6" ABOVE CEILING.

BRACE TOP OF WALLS TO STRUCTURE ABOVE. PROVIDE ACOUSTICAL INSULATION

BATTS BETWEEN STUDS FULL HEIGHT. AT TILED WALLS, PROVIDE ACOUSTICAL

BATT INSULATION FULL HEIGHT, WATERPROOF MEMBRANE, AND 5/8"

CEMENTITIOUS BACKER UNITS PER TILE COUNCIL OF AMERICA (TCA) DETAIL W244.

SEE RESTROOM ACCESSORIES ELEVATIOS, SHEET A-3.0, FOR WALL FINISHES. AT

NON-TILED WALLS, PROVIDE 5/8" TYPE "X" GYP. BOARD BOTH SIDES FULL HEIGHT,

TAPED, WITH ORANGE PEEL TEXTURE AND PAINT.

PROVIDE 3 FIXED PAINTED SHELVES SPACED 1'-6" O.C WITH BOTTOM SHELF AT

2'-6" A.F.F.

REPLACE EXISTING CEILING MOUNTED EXHAUST FAN WITH NEW FAN OF LIKE KIND

OR EQUAL. POWER FOR FANS TO BE CONNECTED TO LIGHT SWITCHES. REPLACE

ALL CEILING MOUNTED MECHANICAL GRILLES AND DIFFUSERS WITH NEW.

STRUCTURAL STEEL COLUMNS AND LINTEL. SEE DETAIL1/A-4.0.

PROVIDE 1 3/4" THK, SOLID CORE OAK VENEER WOOD DOOR (SEE PLAN FOR

WIDTH AND HEIGHT), STAINED TO MATCH OTHER OTHER WOOD DOORS IN THE

FACILITY, WITH PAINTED HM FRAME AT MAIN RESTROOMS AND LOUNGE

RESTROOMS. ON DOORS AT MAIN RESTROOMS: PROVIDE PUSH/PULL DOOR

HARDWARE, 12" HIGH BRUSHED STAINLESS STEEL KICK PLATES, AND AUTOMATIC

CLOSURES WITH BRUSHED STAINLESS STEEL FINISH. ON DOORS AT LOUNGE

RESTROOMS: PROVIDE PRIVACY FUNCTION ADA LEVER LOCKSET WITH BRUSHED

STAINLESS STEEL FINISH.

PROVIDE 120 VAC GFI DUPLEX OUTLET 37 1/2" A.F.F. TO CENTERLINE. SEE

KEYNOTE 17/A-3.0, AND INTERIOR ELEVATIONS ON SHEET A-3.0 FOR ADDITIONAL

INFORMATION.

PROVIDE NEW FLOOR DRAIN.

PROVIDE SOLID SURFACE COUNTERTOP WITH 4" HIGH SOLID SURFACE

BACKSPLASH, CORIAN OR APPROVED EQUAL.

PROVIDE ACOUSTICAL LAY-IN CEILING SYSTEM AT 7'-6" A.F.F. TO MATCH

ADJACENT EXISTING CEILING.

EXTEND EXISTING SUSPENDED ACOUSTICAL CEILING INTO NEWLY CREATED

ALCOVE WITH GRID AND LAY-IN PANELS TO MATCH EXISTING GRID AND LAY-IN

PANELS.

INFILL VOID IN WALL TO MAKE WALL FLUSH WITH ADJACENT SURFACES.

PROVIDE HORN STROBE, TO BE COMPATIBLE WITH EXISTING BUILDING FIRE

ALARM SYSTEM, MOUNTED 90" ABOVE FLOOR.

BABY CHANGING STATION SEE TA-7/A-3.0.

A-2.0

RESTROOM FLOOR PLAN KEY NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

MAIN RESTROOM DEMO PLAN

1/4"=1'-0"

N

N

TRUE

NORTH

PLAN

NORTH

MAIN RESTROOM FLOOR PLAN

1/4"=1'-0"

LOUNGE RESTROOM DEMO

1/4"=1'-0"

LOUNGE RESTROOM FLOOR

1/4"=1'-0"

1 2

3 4

DRINKING FOUNTAIN DEMO

1/4"=1'-0"

P A

R T

I A

L

F

L O

A

N S

A

A

B

B

CC

C

C

A

B

A

B

H

H

H

E

E

D

D

T

D

D

G

G

F

J

J

K

A

E

F

K

L

M

L

M

C

N

D

D

U

E

F

F

J

J

K

K

L

M

L

M

P

4 4

S

S

S

S

R

F

SAW-CUT

SAW-CUT

SAW-CUTSAW-CUT

WOMEN

MEN

WOMEN

MEN

JANITOR

V

12 12

W

W

Y

TYP

Y

TYP

Y

TYP

X

X

TYP

X

TYP

CLEAR

C L E

A R

NOTE: FLUSH VALVE SHALL BE

LOCATED ON WIDE SIDE OF STALLS

12" MIN

36" MIN

C

L

24" MIN.

TOILET

PAPER

54" MIN

42" MIN

12" MAX.

M

I N

9" MAX.

7" MIN.

M

I N

39"-41"

C

L

CLEAR

FLOOR

SPACE

48" MIN

19" MAX

17" MIN

M

I N

CLEAR

FLOOR

SPACE

36" IF IN ALCOVE

GREATER THAN 24"

DEEP

30" TYP

T

Y P

MIN.

13 1/2" .

M

A X

M

A X

BACKSPLASH

COUNTER

SIGN

M

A X

8" MAX

T

Y P

C

L

FRONT VIEW

(DOUBLE)

FACE OF

ADJACENT

WALL

SIDE VIEW

EDGE OF WALL

BEYOND

WIDTH OF ALCOVE

48" MIN

24" MIN CLR

F

E A

D I N

G

E

D G

E

T

O

B

O T

T O

M

DEPTH OF

24" MAX

ALCOVE

15" MIN.

C

L

T

S

O

U T

M

A X

I M

M

A X

S

O

U T

M

A X

F

A

D I N

G

E

D G

E

T

O

B

O T

T O

M

CLEAR FLOOR

SPACE

60" MIN

M

I N

C

L

16" - 18"

KNEE

CLEARANCE

8" MIN

17" MIN

11" MIN

M

A X

M

A X

M

A X

M

I N

MIN.

13 1/2" .

CLEARANCE TO

OBSTRUCTION

COAT

HOOK

GRAB BAR

TOILET

PAPER

DISPENSER

M

I N

R E

A C

H

R

A N

G E

M

A X

MIRROR

F

L E

C T

I N

G

S

U R

F A

C E

M

A X

C

L R

C L

R

M

I N

T O

P

O

F

G

R A

B

B

A R

M

A X

PAPER

TOWEL

DISPENSER

SOAP

DISPENSER

M

A X

35 1/4"

4" 15"

FACE OF WALL

FRONT VIEW SIDE VIEW

SOLID SURFACE COUNTER

TOP AND BACKSPLASH ON

3/4" WATER-RESISTANT

PLYWOOD BACKING

3x3x1/4 STEEL ANGLE

COUNTERTOP SUPPORT

FRAME - PROVIDE 1 UPRIGHT

PER STUD

TYPICAL STEEL STUD

FRAMED WALL

1'-10"

WALL FINISH

WALL FINISH

TYPICAL STEEL STUD

FRAMED WALL

3x3x1/4 STEEL ANGLE

COUNTERTOP SUPPORT

FRAME - PROVIDE 1 UPRIGHT

PER STUD

M I N

(5) 1/4 - 20 SELF-DRILLING

SCREWS EQUALLY SPACED

PLAN SECTION

Drawing Number:

A B C D E F G H

FILENAME: PLOT DATE: PLOT TIME:$FILENAME $PLOTDATE $PLOTTIME

SHEET of 4

STEEL FABRICATION GENERAL NOTES

1.

2.

3.

4.

5.

6.

FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.

ALL WORK SHALL BE IN ACCORDANCE WITH UFC 1-200-01

GENERAL BUILDING REQUIREMENTS.

TOOL ALL MATING PARTS AS REQUIRED FOR SNUG FIT, TYP.

REMOVE ALL BURRS AND SHARP EDGES.

FINISH ALL FABRICATED STEEL PARTS WITH ONE PRIME COAT

AND TWO FINISH COATS.

DIMENSIONAL TOLERANCES FOR STEEL FABRICATIONS:

.XX = +/- .02 "

.XXX = +/- .010"

A-4.0

D E

T A

I L S

STRUCTURAL SUPPORT AT MASONRY OPENING

A

3/8"=1'-0"

ELEVATION

A

SECTION

1"=1'-0"

EXISTING BRICK

MASONRY WALL

L 4 x 4 x 5/16

LINTEL EACH SIDE

STEEL TUBE

COLUMN BEYOND

1/4" x 2"

STEEL BAR

CLOSURE

FULL LENGTH

D

B

BASE ANCHOR DETAIL

3"=1'-0"

B

COLUMN BASE

CONNECTOR

SEE DETAIL C

BRICK MASONRY WALL

8 x 2 x 1/8 TUBE

STEEL COLUMN

EXISTING CONCRETE

FLOOR

HILTI HLC-H

3/8 x 1 7/8

SLEEVE ANCHOR

OR APPROVED

EQUAL

C

3"=1'-0"

1/8" THICK STEEL

.500" DIA, 2 HOLES

BRICK MASONRY WALL

STEEL LINTEL

TUBE STEEL COLUMN

D

TYPICAL COLUMN

3"=1'-0"

ACCESSIBLE TOILET

3/8"=1'-0"

CLEAR FLOOR SPACE AT

GRAB BARS

3/8"=1'-0"

BACK WALL

GRAB BARS

3/8"=1'-0"

SIDE WALL

CLEARANCES

3/8"=1'-0"

ACCESSIBLE SINK

NOTE: PROVIDE INSULATION GUARD

FOR ALL UNDER-SINK PIPING.

FLOOR SPACE

3/8"=1'-0"

ACCESSIBLE SINK

ACCESSIBLE URINAL

3/8"=1'-0"

CLEAR FLOOR SPACE AT

ACCESSIBLE URINAL

3/8"=1'-0"

WALL MOUNTED

STANDARD URINAL

3/8"=1'-0"

WALL MOUNTED

ELECTRIC WATER COOLER

3/8"=1'-0"

TOILET ACCESSORIES

3/8"=1'-0"

SIGNS & COUNTERS

3/8"=1'-0"

VERIFY FIT OF COLUMNS AND

COLUMN BASE CONNECTORS

BEFORE DRILLING MOUNTING

HOLES IN CONCRETE

BASE CONNECTOR

TYPICAL COLUMN

LINTEL CONNECTION

TYPICAL COLUMN TO

TUBE STEEL

COLUMNS

STEEL LINTEL

EXISTING

BRICK

MASONRY

WALL

BABY CHANGING STATION

3/8"=1'-0"

COLUMN SHALL BEAR ON

COLUMN BASE CONNECTOR

ALL AROUND

A-4.0

COUNTERTOP DETAILS

1/2"=1'-0"