Attachment_4_SOMS_CZQZ_11-0099_rev1.pdf
PDF 12 KB Posted
- Attached to
- Cannon AFB Fire Station overhead garage doors Federal contract opportunity
- Solicitation number
- FA4855-16-B-0019
About this file
Attachment 4 SOMSCZQZ11-0099
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LI
N
E N
U M
B
ER
ITEM, DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF
SUBMITTAL
C
ER
TI
F
O F
C O
M
PL
IA
N
C E
SC
H
ED
U
LE
S/
PL
A
N S
SH
O
P D
R A
W
IN
G S
SA
M
PL
ES
C
O
LO
R S
EL
EC
T
TE
ST
R
ES
U
LT
S
M A
N F'
R R
EC
O
M M
EN
D
A
TI
O N
S
M A
N F'
R . W
A R
R A
N
TY
LI
C
EN
SE
D A
PP
LI
C A
TO
R
M A
N U
F' S
TE
C
H N
IC
A
L D
A
TA
O
M M
A N
U A
LS
O
TH
ER
R
EQ
U
IR
ED
S
U B
M
IS
SI
O
N D
A
TE
D A
TE
R
EC
EI
VE
D
IN
C O
N
TR
A C
TI
N
G
D A
TE
T
O C
IV
IL
E N
G
IN
EE
R
IN
G
R
ET
U R
N S
U
SP
EN
SE
D A
TE
FO
LL
O W
-U P
C O
N
TR
A C
TO
R
N O
TI
FI
ED
A pp ro va l D at e
C O
N
TR
A C
TO
R
N O
TI
FI
ED
D is
A pp ro va l D at e
C O
N
TR
A C
TO
R
R E-
SU
B
M
IT
TA
L
FI
N
A L
A
PP
R O
VA
L
R
EM
A R
K S
Attachment 1, 01 33 00.Paragraph
1.11 Quality Control Plan(QCP) 3
14 days after PRE-CON
Attachment 1, 01 32 01.00 10 Paragraph 3.1 subparagraphs .1 thru .5 Project Schedule -
14 days after PRE-CON
3 Attachment 1, 01 35 40.00 20 paragraph 1.8 Environmental Protection Plan
3 14 days after PRE-CON
4 Attachment 1, 01 74 19 Paragraph
1.6 Waste Management Plan
3 15 Days after Award
Attachment 1, 01 35 26.paragraph 1.7 Accident Prevention Plan -Ref. EM385 1- 1 Section:3, 4, 5, 6, 7,9,10,11,13,14,15, 16,21,22,24,25,27,32, Appendix A
3 14 days after PRE-CON
Attachment 1, 01 35 26 Paragraph 1.9 Activity Hazard Anaysis Ref. EM385-1- 1 Section 28 and fig. 1-2 3
15 days Prior to Each Phase/Definable feature of Work
Attachment 1, 01 01 00.Paragraph
1.9 - AF Form 103 - Work Clearance Request
3 2 Weeks after Award
Attachment 1, 01 32 16.00 20 Paragraph
1.2 Construction Progress Schedule
14 Days After Notice To Proceed and when changes to Schedule Occur
9 Attachment 1, 01 01 00 Paragraph 1.8 Utility Outage Request
3 3 NLT 10 days prior to Outage
Attachment 1, 01 35 26 Pargraph 1.13.B Accident Report-Ref EM385-1- 1 section D
As Incident Occurs
11 Attachment 1, 01 35 26 Paragraph
1.14 Hot Work Permit Ref EM385-1-1 section
6-C
3 As Incident Occurs
Attachment 1, 01 30 00 Paragraph 1.8 DD
1354 TRANSFER AND ACCEPTANCE OF
MILITARY REAL PROPERTY 3
14 Days After Final Inspection
NUMBER OF COPIES REQUIRED
AF FORM 66 SCHEDULE OF MATERIALS SUBMITTALS
PROJECT # CZQZ 11-0099 PROJECT TITLE: RPR FIRE STATION
GARAGE DOOR
SOLICITATION/CONTRACT NO.
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR
13 Attachment 1, 01 78 23 Paragraph
1.5.5 Electronic As-Builts
3 2 Weeks after BOD
14 Attachment 1, 01 78 23 paragraph 1.5.5.b Hardcopy/ Electronic As-Builts
3 NLT 2 Weeks Ater Project Completion
15 Attachment 1, 01 33 00 paragraph 1.1.A.10 & 01 78 23 paragraph 1.2 O&M manuals
3 NLT 2 Weeks Ater Project Completion
16 Attachment 1, 01 33 00 paragraph 1.1.A.4 Product Data for radios(long lead item for approving frequency)
3 10 Days after Award
17 Attachment 1, 01 33 00 paragraph 1.1.A.4 Product Data 3 14 days Prior to Construction Start
18 SOW paragraph 3.3 Survey reports of Existing Electrical systems to include controls
3 10 Days after Award
19 Attachment 1, 01 33 00 paragraph 1.1.A.4 Product Data 3 14 days Prior to Construction Start
20 SOW, paragraph 3.6 Warranty for doors, motors and accessories.
3 3 14 days Prior to Construction Start
File details come from the government source that posted it. Updated .