Attachment_2_-_Specifications_LOC_Consoles.pdf

PDF 357 KB Posted

Attached to
Alternate Command Post and Link Operating System Console Furniture Federal contract opportunity
Solicitation number
FA4661-16-Q-0091
Issued by
Department of the Air Force Air Combat Command

About this file

Attachment 2 - Specifications LOC Consoles

View the file

Other files for this federal contract opportunity

Other files attached to Alternate Command Post and Link Operating System Console Furniture, newest first.
File Type Posted
FA4661-16-Q-0091_ACP_Console_Furniture.pdf PDF
Attachment_4_-_Question_Form.doc DOC document
Attachment_1_-_Specifications_ACP_Consoles.pdf PDF
Attachment_3_-_Room_Layout_for_LOC_Consoles.pptx PPTX presentation

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

29 June 2016

MEMORANDUM FOR INTERESTED VENDORS

FROM: 7 CONS/LGCB

SUBJECT: Specifications for Link Operations Center Furniture Consoles

1. The 7 BW Link Operations Center (LOC) Building 8032 facility is a mission critical C2 operation with high demands and unique challenges which requires absolute functionality in design and also fit the limited space available. This control room enclosure system must also have the ability to reasonably adapt to future C2 system upgrades and must be designed around the Link-16 Management Control System (four (4) Monitors mounted to Desk and CPU Secured inside desk) and Live-Virtual-Constructive-Simulation (LVC) P5 systems hardware/software suite. Link management consoles must meet rigorous ergonomic standards, easily adapt to changes in layout and equipment, efficiently organize hardware and include structurally superior products that will withstand the stresses of around-the-clock 24/7/365 operations. The LOC will be used to control special use airspace operations and a satellite data network for real-world flight operations and operational flight test/training. LOC will not accept a traditional office furniture solution that is not designed for 24/7/365 operations of Satellite Link management and airspace control.

2. The contractor shall purchase and install ergonomically designed furniture consoles that have positions each for the link operators and a manager at building 8032, Dyess AFB, Texas capable of supporting 24 hour operations. The consoles must have the ability to move from a seated to a standing position and include built-in storage between each position for binders and printing equipment. Each position (7 positions total) on each console, must have enough space for personnel to work with multiple checklist binders open and laid out. The console positions must have the ability to mount as many as 6 monitors to a vertical surface with swing arms to free up counter space. The consoles must be spacious enough to have multiple keyboards and peripheral items. Integrate CPU storage within the frame structure of the console. The computer systems need to be hideaway and be able to be separated by 3 feet due to EMSEC (Emissions Security) requirements. The wiring and cabling must be able to be feed into the console via a raised floor and must not be visible. The furniture will not be located against the walls so the consoles must have built-in power sources, capable of handling the surge placed by the electronic systems they will house. There will also be multiple UPS that will need to be stored in the consoles themselves. The design should be able to accommodate a similar floorplan as the attachment design. Finally, install the new furniture.

3. OPTIONAL: Install all computer and communications equipment into the console furniture if the furniture is not in place prior to the equipment installation. The contractor shall provide a minimum one year service warranty on all products provided. The complete/design setup must look professional and functional.

Attachments:

1. Room Photos/Room Layout

ROOM PHOTOS

- Back door will not be utilized but cannot be blocked due to fire hazards. The left corner should contain a corner unit, for one (1) position, and the right corner should maintain enough space for two (2) positions.

- Corner of room should contain at least two (2) positions.

- Open Area; will not be utilized and will not be blocked off.

- Wall should contain at least two (2) positions.

ROOM LAYOUT: