This document is an asbestos and lead-based paint inspection report for Building 1705 at Malmstrom Air Force Base in Montana. The report identifies four homogeneous areas containing asbestos above 1% by volume in flooring materials throughout the building. It also notes two materials containing measurable asbestos below 1%.
The related federal contract opportunity is a solicitation to demolish Building 1705. The contractor will provide all labor, supplies and supervision to perform the demolition as defined in the statement of work. As the requirement is solely for structure removal and land restoration, it is subject to the Service Contract Labor Standards Act rather than the Davis-Bacon Act. The solicitation was issued by the Department of the Air Force Global Strike Command.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| COMBO_Amended_15 July 22.pdf | ||
| MFR_Amendment 002.pdf | ||
| COMBO_Extended.pdf | ||
| MFR_Amendment 001.pdf | ||
| QA_6 July 2022.xlsx | XLSX spreadsheet | |
| QA_24 June 2022.xlsx | XLSX spreadsheet | |
| QA_14 June 2022.xlsx | XLSX spreadsheet | |
| Atch 5_Drawings_Combined.pdf | ||
| COMBO.pdf | ||
| Atch 2-BidSched_Bldg1705Demo_23 May 22.xlsx | XLSX spreadsheet | |
| Atch 1_Specs Combined.pdf | ||
| Atch 3-PastPerformance.xlsx | XLSX spreadsheet | |
| Atch 4-InstalPerimAccessControl.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos and Lead Based Paint Study for
BUILDING 1705
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 341ST MISSILE WING (AFGSC)
MALMSTROM AFB, MONTANA
CONTRACT NO: FA 4626-12-D-0004
DELIVERY ORDER NO: 0002
PROJECT NO: NZAS 11-1004
PURCHASE REQUEST NO: F2W3D22208A001
December 4, 2012
BY: ARCHITECTS DESIGN GROUP, pc
Asbestos and Lead Based Paint Study for Building 1705
Report Index
EXECUTIVE SUMMARY
APPENDIX A
Documentation of Accreditation
APPENDIX B
Asbestos Laboratory Reports
APPENDIX C
Asbestos Sample Locations
APPENDIX D
Lead Based Paint Sample Results
APPENDIX E
Lead Based Paint Sample Locations
Asbestos and Lead Based Paint Study for Building 1705
1800 River Drive North Great Falls, MT 59401 (406) 761-3010 FAX (406) 727-2872
December 3, 2012
Mr. Glen Anacker
Architect Design Group
No. 1 Sunset Plaza, Kalispell, MT 59901
RE: Pre- Demolition Asbestos and Lead Paint Inspection
Building 1705
Malmstrom A.F.B., Montana
TD&H Project No. 12-270-073
Dear Mr. Anacker, In accordance with our Agreement for Engineering Services, Thomas, Dean, & Hoskins, Inc.
(TD&H) performed a pre-demolition asbestos and lead paint inspection of MAFB Building 1705 in October and November 2012. The entire building is proposed for demolition.
PROJECT DESCRIPTION
The building is an approximately 13,166 square foot, single story building. The building consists of offices, storage areas, truck loading docks, and maintenance rooms. The interior walls of the building are drywall, concrete and CMU block with wall panels in the rest rooms, ceilings are drywall or drop-in panels. The flooring is sheet vinyl flooring, tile, or carpet over concrete. The exterior consists of CMU block or concrete walls with concrete sidewalks and foundation. The roofing consists of a membrane over the majority of the building with some asphalt shingles over the entryway to the office area.
ASBESTOS INSPECTION
Administrative Rules of Montana (ARM) 17.74.354 requires an asbestos inspection be completed for all building materials prior to scheduled demolition activities to determine if asbestos-containing building materials (ACBM) are present. The National Emissions Standards for Hazardous Air Pollutants (NESHAP – 40 CFR 61) and the ARM regulate asbestos due to the respiratory hazard that airborne asbestos fibers present. The inspections were performed by
Montana-accredited asbestos inspectors in accordance with the Environmental Protection
Agency (EPA) – Asbestos Hazards and Emergency Response Act (AHERA) regulation 40 CFR
763. Documentation of accreditation is provided in Appendix A.
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
12-3-2012 .doc
Building materials were identified, categorized, numbered, and placed into homogeneous areas for sample collection and laboratory analysis. The number of samples collected from building materials identified in the inspection is based on the following:
Surfacing Materials: three samples for surfacing materials between 1 and 1,000 square feet (SF), five samples for surfacing materials between 1,000 and 5,000 SF, seven samples for surfacing materials over 5,000 SF.
Thermal System Insulation: three samples from each homogeneous area (HA) of thermal system insulation, which may include boiler insulation, mudded fittings, and/or expanded vermiculite insulation.
Miscellaneous Materials: At least three samples from each homogeneous area of miscellaneous material, such as ceiling tile, plaster, sheetrock (drywall), cove base, electrical wiring insulation, concrete, roofing, and brick and mortar.
Patching Materials: At least one sample from each homogeneous area of patching material, such as replacement floor tiles or patching plaster, or materials of less than 3 SF in total area.
A total of twenty-seven suspect building materials were identified during the inspection. Bulk samples were collected from the building in accordance with the currently recognized standard protocol developed under AHERA. Bulk samples were placed into containers and shipped to
Pace Analytical in Billings, Montana, for analysis using Polarized Light Microscopy (PLM) in accordance with the EPA Method 600/R4-93-116. Pace Analytical is accredited through the
National Institute of Standards and Technology’s (NIST) National Voluntary Laboratory
Accreditation Program (NVLAP). The limit of detection for this method is approximately 1% by volume.
Four homogenous areas (HAs) sampled during the inspection were determined by laboratory analysis to contain asbestos in quantities greater than 1% and are shown in Table 1. Also listed in Table 1 are two materials that contained measurable concentrations of asbestos that were less than 1% by volume. These Has are not an asbestos-containing material (i.e. non ACM) and requires no special treatment for disposal, but does require additional measures to comply with
Occupational Safety and Health Administration (OSHA) regulations.
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Table 1
Asbestos-Containing Building Materials
MAFB Building 1705
Homogeneous
Area (HA)
Sample
Description
Asbestos
Content
NESHAP
Category
Approximate
Area (sf)
Location-
Room
F3.4 dark brown sheet flooring under F6.1
10% chrysotile
(white) 4% chrysotile
(black) I 1,590 23,24,25,26
F3.3
6x6 green tile w/ black streaks 10% chrysotile I 340
1/2 of Room
F3.2
6x6 alternating white & black floor tiles with streaks
3% & 4% chrysotile
(black) 10% chrysotile
(white) I 2,030 19,21,22
M2.5*
4" rust cove base-mastic <1% chrysotile Non-ACM --- 21A,19
M6.1* window glazing trace chrysotile Non-ACM --- 28
F3.5
12x12 wood like floor tile w/ mastic
12% chrysotile
(white) 8% chrysotile
(black) I 325 27,21
*Subject to OSHA regulations during removal.
All other HA’s are listed as “None Detected” and are shown in Table 2. The analytical reports provided by Pace Analytical are provided in Appendix B. Sample identification and locations are shown on the figure in Appendix C.
Following receipt of the laboratory report, the building materials containing asbestos were placed into one of the following three categories using NESHAP criteria:
Category I: non-friable asbestos-containing packings, gasket, resilient floor covering, and asphalt roofing products – all containing more than 1% asbestos.
Category II: All non-friable materials containing more than 1% asbestos except those found in Category I.
Regulated Asbestos-Containing Materials (RACM): friable materials, Category I non-friable materials that will or may be subjected to sanding, grinding, cutting, or abrading; or Category II non-friable materials that have a high probability of becoming or have become crumbled, pulverized, or reduced to powder by forces expected to act on the material in the course of demolition operations.
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Table 2
Non-Asbestos-Containing Building Materials
MAFB Building 1705
Homogenous
Area (HA) Sample Description Location-Room
F1.1/F5.1 cream w/ tiny blue specks sheet flooring w/ mastic 7,28
F3.1
8x8 floor tile mastic - cream w/ brown & white streaks 30,6,15
F3.6/F5.6 4x4 tile like sheet flooring mastic - tans/browns 15
F6.1 carpet mastic blue/tan weave pattern 24,25,26,22,23,12,13
F6.2 carpet mastic blue/tan/maroon specks 27
F6.3 maroon tan carpet mastic 16,17,18
F6.4 gold carpet mastic under F6.1 22
M1.1 drywall throughout
M16.1 concrete exterior & interior floors/walls
M17.1 CMU mortar exterior & interior walls
M2.1 6" dark brown cove base mastic 12,13,23,24,25,26
M2.2 4" gray cove base mastic 27
M2.3 4" tan cove base mastic 7,28,15,16,17,18
M2.4 4" brown cove base mastic 6,9,15,30,12,13
M4.1 2x4 white ceiling tiles w/ fissures & pinholes throughout
M4.2 2x4 white ceiling panels pinholes with short fissures throughout
M8.1 white wall panel mastic 7,28
R1.1 roofing throughout
R1.2 shingles with black backing over 23
T4.1 vibration collar 1
T2.1 mudded fittings 1
According to the NESHAP regulation 40 CFR 61.145 (c)(1)(i) and ARM 17.74, any Category I or II ACM that may be rendered friable during demolition must be properly abated prior to demolition. However, NESHAP also requires that when ACM is present, there must be no visible dust caused by general demolition activities. All building materials should be adequately wetted to prevent release of particulate. Depending on the type of demolition planned, OSHA and state regulations may require personal air monitoring and the use of engineering controls.
It is also a requirement under the NESHAP regulation that at least ten working days prior to an asbestos abatement project, a written notification must be provided to the EPA. In the State of
Friable means able to be crushed or reduced to powder by hand pressure when dry, or similarly broken or pulverized mechanically.
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Montana, notification of asbestos abatement is sent to the Montana Department of
Environmental Quality (MDEQ), Permitting and Compliance Division – Asbestos Control
Program.
LEAD-BASED PAINT INSPECTION
Lead-based paint (LBP) surveys were conducted to identify painted components that may require specialized handling to comply with the requirements of OSHA or special disposal under the
Resource Conservation and Recovery Act (RCRA), which is administered by the EPA. The surveys were performed by an experienced technician with training as a LBP risk assessor.
Lead-Based Paint
Lead-based paint (LBP) is of concern both as a source of direct exposure through ingestion of paint chips and as a contributor to lead in interior dust and exterior soil. Regulatory agencies, which have addressed lead-based paint, include the Environmental Protection Agency (EPA), Department of Housing and Urban Development (HUD), OSHA, and the Consumer Products
Safety Commission (CPSC). There is no state program for lead.
HUD guidelines define lead-based paint as:
Paint in liquid form which contains 0.06%, by weight, calculated as lead metal in total nonvolatile content of the liquid paint, or
Paint already applied which tests equal to or greater than 1.0 milligrams per square centimeter (mg/cm ) when using X-Ray Fluorescence (XRF) technology, or 5,000 milligrams per kilogram (mg/kg) (0.5% by weight) when using atomic absorption spectroscopic analysis (AA).
Lead-Containing Paint (LCP)
The term “lead-containing paint” is used for paint that has lead concentrations at less than the
HUD guidelines or EPA disposal regulations. The OSHA standard for lead in the construction industry does not recognize a minimum safe concentration of lead. If any painted surface has any detectable level of lead, it must be presumed to present an occupational exposure to lead for
OSHA-regulated construction work until a negative exposure assessment or exposure monitoring establishes otherwise.
Methods
A Niton X-ray fluoroscope (XRF) was used to test paint for lead. The XRF instrument provided a real concentration of LBP based on the generated spectra and an algorithm programmed into the instrument. The XRF was standardized prior to the start, mid-day, and after the conclusion each day of LBP surveying against lead-based paint standards provided by the manufacturer of the XRF.
Results
Forty-five painted surfaces tested positive for lead-based paint and are listed in Table 3 below.
Thirty-three surfaces were analyzed as lead-containing. Results of all painted surfaces analyzed
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report are contained in Attachment D, and XRF sample locations are shown in Figures 1 – 3 in
Attachment E.
Table 3
Samples Testing Positive For Lead Paint
MAFB Building 1705
Sample
No. Substrate Color Sample Description Location
XRF
Reading
(mg/cm
Area or
Length of
LBP (sf, lf)
3 metal tan roof vent air intake east side 0.05
5 metal light gray door Rm 31 west side 1.30 20 sf
6 metal light gray door casing Rm 31 west side 1.70 100 sf
8 concrete gray lower wall Rm 31 north side 0.15
10 CMU gray lower wall Rm 31 south side 0.24
11 concrete white ceiling Rm 31 center 0.02
12 metal white roof truss Rm 31 center 0.05
13 metal light gray door Rm 31 east side 1.60 120 sf
29 metal white roof truss Rm 24 center 0.02
30 wood white door Rm 25 east side 0.04
31 wood white door jamb Rm 25 east side 0.02
36 metal white door casing Rm 27 north side 0.05
38 CMU white wall Rm 27 west side 1.30 64 sf
39 concrete white wall Rm 27 west side 0.40
40 metal brown door Rm 28 west side 3.30 45 sf
41 metal brown door casing Rm 28 west side 1.50 15 sf
43 metal white window frame Rm 28 north side 1.10 3 lf
45 concrete white wall under metal panels Rm 28 north side 2.30 150 sf
48 metal white HVAC ceiling duct Rm 6 center 0.70
49 metal white roof support I beam Rm 6 center 3.40 150 lf
51 concrete white wall Rm 6 west side 0.17
59 metal white vault frame Rm 6 west side 1.50 30 sf
60 metal white vault door Rm 6 west side 2.30 25 sf
61 metal white vault frame Rm 6 west side 2.70 30 sf
62 wood white vault door Rm 6 west side 0.13
63 metal dark brown door
Rm 6 southwest side 2.30 50 sf
64 metal dark brown door casing
Rm 6 southwest side 2.00 15 sf
66 metal dark brown door casing Rm 6 south side 5.20 15 sf
67 metal dark brown door Rm 6 west side 2.20 50 sf
68 metal dark brown door casing Rm 6 west side 2.40 15 sf
69 metal dark brown door casing Rm 6 north side 5.60 15 sf
73 CMU white wall Rm 30 east side 0.17
74 metal white breaker box Rm 30 east side 0.02
76 concrete white wall Rm 5 south side 0.03
78 wood dark brown door Rm 3 west side 0.01
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Table 3 (cont.)
Samples Testing Positive For Lead Paint
MAFB Building 1705
Sample
No. Substrate Color Sample Description Location
XRF
Reading
(mg/cm
Area or
Length of
LBP (sf, lf)
79 wood dark brown door casing Rm 3 west side 0.01
80 CMU white wall Rm 3 north side 0.03
81 metal white door Rm 1 east side 5.40 100 sf
82 metal white door casing Rm 1 east side 5.60
84 CMU white wall Rm 1 west side 0.01
86 metal gray breaker box Rm 1 west side 0.05
87 metal gray electrical panel Rm 1 west side 0.05
88 metal light tan HVAC air exchanger Rm 1 south side 4.60 250 sf
89 metal white HVAC ceiling duct Rm 1 south side 0.12
90 metal black condensate tank Rm 1 west side 1.20 50 sf
91 metal light gray air exchanger - stand Rm 1 south side 0.03
92 CMU red lower wall Rm 1 west side 0.13
93 metal dark blue HVAC ceiling duct Rm 1 center 0.19
94 metal silver roof stringer - I-Beam Rm 1 west side 2.50 25 lf
97 metal dark brown door Rm 1 east side 0.03
98 metal dark brown door casing Rm 1 east side 0.15
99 concrete off-white wall Rm 1 west side 0.07
103 metal off-white roll-up door - casing Rm 9 - east side 0.27
104 metal off-white roll-up door - frame Rm 9 - west side 5.20 100 sf
105 metal dark brown roll-up door Rm 9 - west side 4.80 250 sf
106 metal off-white roof stringer - H-Beam Rm 9 - center 8.20 80 lf
107 metal off-white roof truss Rm 9 - center 0.20
108 metal off-white ceiling deck Rm 9 - center 0.14
109 CMU off-white wall Rm 9 - south side 0.07
118 metal white HVAC ceiling duct Rm 15 - middle 0.03
119 metal white roof truss Rm 15 - middle 3.80 140 lf
120 concrete white ceiling deck Rm 15 - south side 0.03
121 concrete white wall (behind sheetrock) Rm 15 - south side 0.03
124 metal off-white roll-up door frame Rm 21 - east side 8.00 100 sf
126 concrete off-white wall Rm 21 - north side 0.05
127 metal dark brown roll-up door frame Rm 21 - north side 10.80 30 sf
128 metal dark brown roll-up door frame Rm 21 - north side 6.10 65 sf
129 metal dark brown door Rm 21 - north side 3.60 30 sf
130 metal dark brown door casing Rm 21 - north side 2.90 15 sf
131 metal dark brown door Rm 21 - west side 0.09
132 metal dark brown door casing Rm 21 - west side 0.08
134 metal off-white roll-up door frame Rm 21 - west side 0.17
136 metal off-white roof stringer (H-beam) Rm 21 - center 11.70 60 lf
137 metal off-white roof truss Rm 21 - center 0.02
138 metal off-white ceiling deck Rm 21 - center 0.21
141 concrete gray floor Rm 21 - center 0.30
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Table 3 (cont.)
Samples Testing Positive For Lead Paint
MAFB Building 1705
Sample
No. Substrate Color Sample Description Location
XRF
Reading
(mg/cm
Area or
Length of
LBP (sf, lf)
147 metal white roof truss Rm 12 - center 3.10 140 lf
148 concrete off-white wall Rm 19 - west side 0.10
149 metal dark brown roll-up door casing Rm 19 - west side 5.70 25 sf
150 metal dark brown roll-up door casing Rm 19 - west side 3.60 65 sf
151 metal off-white support column (H-beam) Rm 19 - south side 0.02
153 metal dark brown door casing Rm 19 - north side 4.50 15 sf
155 metal off-white HVAC ceiling duct Rm 19 - center 0.60
156 metal off-white roof stringer (I-Beam) Rm 19 - center 2.90 120 lf
157 concrete off-white ceiling deck Rm 19 - center 0.01
158 metal off-white overhead hoist - support frame Rm 19 - center 2.20 100 lf
159 metal off-white roof truss Rm 19 - center 1.60 320 lf
160 metal dark beige door casing Rm 19 - west side 3.10 15 sf
165 wallboard white wall Rm 22 - west 0.01
168 metal dark brown door casing Rm 23 - north side 3.90 15 sf
169 metal dark brown door casing Rm 23 - west side 3.80 15 sf
171 CMU off-white wall Rm 23 - north side 0.16
172 concrete off-white wall Rm 11 - north side 0.03
173 concrete dark gray floor Rm 11 - center 0.11
174 metal off-white HVAC ceiling duct Rm 11 - center 0.40
175 metal off-white roof truss Rm 11 - center 1.40 280 lf
177 concrete off-white wall Rm 10 - south side 0.13
179 metal choc. brown exterior roll-up door west side - south 0.07
189 fiberglass off-white storage shed - walls east side - north 0.03
190 metal choc. brown storage shed - doors east side - north 23.00 30 sf
191 metal silver exterior storage shed door casing east side - north 1.50 15 sf
195 metal choc. brown exterior roll-up door east side - south 0.06
RECOMMENDATIONS
The following recommendations for materials containing asbestos or lead are based on our observations and the anticipated scope of demolition.
Asbestos
Four areas of ACM and two materials contaminated with asbestos were identified. The Category
I ACM are nonfriable materials and if maintained in a nonfriable state may be removed in an unregulated fashion under state and federal law and disposed of as general construction waste.
Any grinding, sawing, abrading, or pulverizing of the asbestos containing material will render those materials friable and regulated (RACM).
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Asbestos abatement for RACM must be performed by an EPA certified abatement contractor. All personnel involved in the disturbance or removal of building components assumed to contain asbestos or identified as asbestos-containing must be trained according to the requirements set forth in 29 CFR 1926.1101 (k)(9) and 75-2-511, Montana Code Annotated (MCA).
Asbestos removal for ACM in a nonfriable “intact” condition must be overseen by a “competent person” holding current Montana accreditation as an Asbestos Contractor/Supervisor. If these materials are removed in a nonfriable manner, asbestos abatement permitting will not be required. Limited air monitoring may be necessary for OSHA compliance.
While federal law permits disposal of Category I and II nonfriable ACM in a Class II landfill as general waste, all categories of ACM must be segregated from the general demolition waste for disposal in the designated asbestos disposal area at the High Plains Sanitary Landfill located north of Great Falls. RACM materials must be double-wrapped in 6 mil plastic sheeting; non-
RACM may be single-wrapped. All material must be wrapped “burrito style” with taped seams.
The name and contact information of the owner must be provided in each waste package. We recommend that contractors contact Montana Waste Systems for clarification prior to bidding.
Lead
Work involving components covered with paint containing lead is governed by regulations of the
Occupational Safety and Health Administration (OSHA). Disposal of lead, paint containing lead, or building materials covered with paint containing lead is governed by regulations of the
U.S. Environmental Protection Agency (EPA).
Environmental Protection Agency. EPA’s Lead-Based Paint Renovation, Repair and Painting
Program Rule contained in 40 CFR Part 745, Subpart E, requires workers to be trained to use lead-safe work practices and requires renovation firms to be EPA-certified; these requirements became effective April 22, 2010. Since the building involved in the demolition is not a child occupied facility or pre 1978 housing, only the EPA regulations described below will apply.
EPA Regulations for Disposal of Lead-Based Paint Components. If a waste stream with a concentration of 5 milligrams per liter or more when tested using the Toxicity Characteristic
Leaching Procedure (TCLP) exceeds the Resource Conservation and Recovery Act (RCRA)
TCLP Rule (40 CFR261.24) regulatory standard for hazardous waste disposal, then disposal of lead-based painted components requires special handling and disposal in landfills classified to accept the hazardous waste.
Occupational Safety and Health Administration The lead-based/lead-containing surfaces found in this survey are intact and if not disturbed do not present a hazard to employees involved in the renovation. If these components are disturbed in a manner such as described below, then a hazardous condition may result and will need to be addressed according to OSHA regulations.
The OSHA standard for Lead in Construction, 29 CFR 1926, does not recognize a safe level of lead in dried paint to which workers may be exposed in an occupational setting. Consequently, J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report any disturbance to painted surfaces which contain a measurable quantity of lead must be considered as having the potential to create a risk to workers.
The OSHA standard cites a Permissible Exposure Level (PEL) of 50 micrograms of lead per cubic meter of air (μg/m ) and an Action Level (AL) of 30 μg/m
. Any amount above these levels triggers several safety and health provisions, including, but not limited to:
1. A respiratory protection program
2. Personal protective clothing and equipment
3. Changing areas including segregated storage of work and non-work clothing
4. Hand-washing facilities
5. Blood testing
6. Employee training
If an employee is performing any of the following tasks:
1. Manual demolition, dry scraping, or dry sanding
2. Heat gun applications
3. Power tool cleaning
4. Other industrial operations involving lead as specified in the OSHA standard, then all of the above-mentioned safety items must be provided to the employees. If it is found that either the AL or the PEL is being exceeded, then other safety requirements must be met.
A negative exposure assessment (NEA) should be completed on employees that are performing the work. The NEA would ensure that good work practices may prevent employee exposure to elevated concentrations of airborne lead. The NEA should be performed on the same employees, using the same methods, and using the same tools that will be used for the duration of the project.
Recommended Response Actions. The level of hazardous materials for the composite waste stream from the project can be lowered by separating all painted metal components from all other waste. Recycling of the metal will result in a scrap metal waste stream requiring no further segregation or treatment in respect to lead; however, LPB surfaces should not be sanded or handled in such a way that lead could be liberated from the painted surfaces. Most steel recyclers are equipped to properly recycle lead-painted components. The recycler should be informed of the test results reported herein before transporting the materials to the recycling center. A receipt must be obtained from the recycling facility that is detailed enough to explain what was delivered to the facility.
TCLP sampling of the remaining waste stream will be required by High Plains Sanitary Landfill which serves the Great Falls area. Wooden or other components with LBP that fail TCLP testing are generally more difficult to deal with than steel. The LBP may be removed from these substrates to reduce the amount of hazardous waste generated. Chemical fixation of the LBP may be feasible to render the components nonhazardous. If neither of these solutions is practical, the components must be disposed of in a Class I landfill.
J:\2012\12-270 Architects Design Group\INDUSTRIAL HYGIENE\BLDG 1705\073 Building 1705\MAFB Bldg 1705 Asbestos_Lead Report
Any work with LBP and LCP that has the potential to expose workers to airborne lead at or above the PEL should be performed by a certified lead abatement contractor.
LIMITATIONS
This asbestos and lead paint inspection report was prepared based on information gathered during several site visits and interpretations of laboratory analytical results provided by Pace
Analytical. The inspection report has been prepared to provide information concerning the various types of building materials that were considered suspect for containing asbestos and lead paint and to inform the owner of the building materials that tested positive.
Most building components were visible and accessible at the time of our site visits with the exception of Room #8 which was locked and not available for inspection. However, additional suspect materials may be encountered during demolition. This asbestos and lead paint inspection report is intended for use by the Architect Design Group and their clients. The scope of services performed by Thomas Dean & Hoskins, Inc., may not be appropriate to satisfy the needs of other users, and any use or re-use of this document, or the findings presented herein is at the sole risk of the user.
We appreciate this opportunity to provide these industrial hygiene-consulting services to you and look forward to assisting you through the remainder of the project. Should you have questions or need further clarification about information contained herein, please feel free to contact us at
761-3010.
Debi Pace, E.I. Peter Klevberg, P.E.
MTA-373 Exp. 5/04/2013 MTA-0627 Exp. 5/04/2013
Industrial Hygiene Technician Project Manager
Oran Grotbo
MTA-2256 Exp. 5/04/2013
Industrial Hygiene Technician
Appendices: A Documentation of Accreditation
B Asbestos Laboratory Reports
C Asbestos Sample Locations
D Lead Based Paint Sample Results
E Lead Based Paint Sample Locations
APPENDIX A
DOCUMENTATION OF
ACCREDITATION
APPENDIX B
ASBESTOS LABORATORY
REPORTS
REPORT OF:
Peter Klevberg Thomas, Dean & Hoskins, Inc.
1800 River Drive North Great Falls, MT 59401
Bulk Material Analysis - 12-270 Building 1705
DATE:
PACE PROJECT NO:
PAGE:
November 16, 2012
10211214
CASE NARRATIVE:
REPORT TO:
On November 2, 2012, our laboratory received 6 bulk material sample(s) from the client. The asbestos analysis was performed in accordance with EPA 600/M4-82-020 and EPA/600/R-93/116 official test methods as outlined in 40CFR763.109 appendix A.
The samples will be held for sixty (60) days from the date of this report.
A < sign indicates the value reported was the practical quantitation limit for this sample using the method described.
Concentrations of analyte, if present, below this were not quantifiable.
Pace Analytical Services, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for conducting asbestos analysis (NVLAP Lab Code 101292-0). Each result listed in the report applies only to the sample analyzed. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government nor may it be reproduced except in full without written approval of Pace Analytical Services, Inc.
Project Manager Analyst/Approved Signatory
Sarah Bleyer - Project Coordinator Michael Otness - Laboratory Analyst
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
Pace Analytical Services, Inc.
602 S 25th Street
Billings, MT 591014549
(406)254-7226
Building Material Analysis
Asbestos Content
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
10211214001 11/16/2012 R1.1A 1/4 Black Tarpaper (5%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (65%) None Detected 100% Nonfibrous Binder
3/4 White Fibrous (25%) None Detected 10% Fibrous Glass
White Solid 90% Nonfibrous Binder
4/4 Black Rubber (5%) None Detected 100% Nonfibrous Binder
10211214002 11/16/2012 R1.1B 1/4 Black Tarpaper (5%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (70%) None Detected 100% Nonfibrous Binder
3/4 White Fibrous (20%) None Detected 20% Fibrous Glass
White Solid 80% Nonfibrous Binder
4/4 Black Rubber (5%) None Detected 100% Nonfibrous Binder
10211214003 11/16/2012 R1.1C 1/4 Black Tarpaper (20%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (35%) None Detected 100% Nonfibrous Binder 3/4 White Fibrous (30%) None Detected 20% Fibrous Glass
White Solid 80% Nonfibrous Binder
4/4 Black Rubber (15%) None Detected 100% Nonfibrous Binder
10211214004 11/16/2012 R1.2A 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
10211214005 11/16/2012 R1.2B 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
10211214006 11/16/2012 R1.2C 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
Michael Otness, analyst
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification and Estimated Quantity
Thomas, Dean & Hoskins, Inc.
1800 River Drive North Great Falls, MT 59401
Bulk Material Analysis - 12-270 Building 1705
DATE:
PACE PROJECT NO:
PAGE:
November 14, 2012
10211079
CASE NARRATIVE:
REPORT TO:
On November 1, 2012, our laboratory received 69 bulk material sample(s) from the client. The asbestos analysis was performed in accordance with EPA 600/M4-82-020 and EPA/600/R-93/116 official test methods as outlined in 40CFR763.109 appendix A.
The samples will be held for sixty (60) days from the date of this report.
A < sign indicates the value reported was the practical quantitation limit for this sample using the method described.
Concentrations of analyte, if present, below this were not quantifiable.
Pace Analytical Services, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for conducting asbestos analysis (NVLAP Lab Code 101292-0). Each result listed in the report applies only to the sample analyzed. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government nor may it be reproduced except in full without written approval of Pace Analytical Services, Inc.
Project Manager Analyst/Approved Signatory
Sarah Bleyer - Project Coordinator Michael Otness - Laboratory Analyst
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
Pace Analytical Services, Inc.
602 S 25th Street
Billings, MT 591014549
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
10211079001 11/9/2012 M4.1A 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079002 11/9/2012 M4.1B 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079003 11/9/2012 M4.1C 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079004 11/9/2012 M1.1A 1/2 White Compound (10%) None Detected 100% Nonfibrous Binder
White Paint
2/2 White Gypsum (90%) None Detected 11% Cellulose
Tan / White
Paper 89% Nonfibrous Binder
10211079005 11/9/2012 M1.1B 1/2 White Compound (10%) None Detected 100% Nonfibrous Binder
White Paint 2/2 White Gypsum (90%) None Detected 11% Cellulose
Tan / White
Paper 89% Nonfibrous Binder
10211079006 11/9/2012 M1.1C 1/2 White Compound (10%) None Detected 100% Nonfibrous Binder
White Paint
2/2 White Gypsum (90%) None Detected 11% Cellulose
Tan / White
Paper 89% Nonfibrous Binder
10211079007 11/9/2012 M17.1A 1/1 Gray Mortar (100%) None Detected 100% Nonfibrous Binder
White Paint
10211079008 11/9/2012 M17.1B 1/1 Gray Mortar (100%) None Detected 100% Nonfibrous Binder
White Paint
10211079009 11/9/2012 M17.1C 1/1 Gray Mortar (100%) None Detected 100% Nonfibrous Binder
White Paint
10211079010 11/9/2012 F3.4A / F5.4A 1/3 Black Linoleum with ridges (80%) None Detected 100% Nonfibrous Binder
2/3 Tan Mastic (10%) None Detected 100% Nonfibrous Binder
3/3 White Leveling Coumpound (10%)
None Detected 100% Nonfibrous Binder
10211079011 11/9/2012 F3.4B / F5.4B 1/4 Tan Mastic (4%) None Detected 100% Nonfibrous Binder
2/4 White Tile (48%) 10% Chrysotile 90% Nonfibrous Binder
3/4 Black Tile (47%) 4% Chrysotile 96% Nonfibrous Binder
4/4 Black Mastic (1%) None Detected 100% Nonfibrous Binder
10211079012 11/9/2012 F3.4C / F5.4C 1/5 Black Linoleum with ridges (20%) None Detected 100% Nonfibrous Binder
2/5 Brown Mastic (20%) None Detected 100% Nonfibrous Binder
3/5 White Leveling Coumpound (20%)
None Detected 100% Nonfibrous Binder
4/5 Gray Thick Tile (38%) None Detected 100% Nonfibrous Binder
5/5 Black Mastic (2%) <1% Chrysotile 99% Nonfibrous Binder
Tan Mastic
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification and Estimated Quantity dap Rectangle dap Rectangle
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification and Estimated Quantity
10211079013 11/9/2012 F6.4A 1/2 White Mastic (50%) None Detected 5% Synthetic Fibers
95% Nonfibrous Binder
2/2 Clear Mastic (50%)* None Detected 100% Nonfibrous Binder
10211079014 11/9/2012 F6.4B 1/2 White Mastic Top (50%)* None Detected 5% Synthetic Fibers
95% Nonfibrous Binder
2/2 Clear Mastic Bottom (50%) None Detected 100% Nonfibrous Binder
10211079015 11/9/2012 F6.4C 1/2 White Mastic Top (50%)* None Detected 5% Synthetic Fibers
95% Nonfibrous Binder
2/2 Clear Mastic Bottom (50%) None Detected 100% Nonfibrous Binder
10211079016 11/9/2012 M4.2A 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079017 11/9/2012 M4.2B 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079018 11/9/2012 M4.2C 1/1 Gray Ceiling (100%) None Detected 20% Cellulose
White Coating 40% Fibrous Glass
40% Nonfibrous Binder & Perlite
10211079019 11/9/2012 F6.1A 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079020 11/10/2012 F6.1B 1/1 Tan Mastic (100%)** None Detected 2% Synthetic Fibers
98% Nonfibrous Binder
10211079021 11/9/2012 F6.1C 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079022 11/9/2012 M16.1A 1/1 Gray Concrete None Detected 100% Nonfibrous Binder
10211079023 11/9/2012 M16.1B 1/1 Gray Concrete None Detected 100% Nonfibrous Binder
10211079024 11/9/2012 M16.1C 1/1 Gray Concrete None Detected 100% Nonfibrous Binder
10211079025 11/9/2012 F3.3A 1/2 Green Tile (97%) 10% Chrysotile 90% Nonfibrous Binder
2/2 Black Mastic (3%) None Detected 100% Nonfibrous Binder
10211079026 11/9/2012 F3.3B 1/2 Hold - Not analyzed
2/2 Black Mastic (3%) None Detected 100% Nonfibrous Binder
10211079027 11/9/2012 F3.3C Hold - Not analyzed
2/2 Black Mastic (3%) None Detected 100% Nonfibrous Binder
10211079028 11/9/2012 F3.2A 1/2 Black Tile (97%) 3% Chrysotile 97% Nonfibrous Binder
2/2 Tan Mastic (3%) None Detected 100% Nonfibrous Binder
10211079029 11/9/2012 F3.2B 1/2 White Tile (98%) 10% Chrysotile 90% Nonfibrous Binder
2/2 Black Mastic (2%) None Detected 100% Nonfibrous Binder
10211079030 11/9/2012 F3.2C 1/2 Black Tile (95%) 4% Chrysotile 96% Nonfibrous Binder
2/2 Black Mastic (5%) None Detected 100% Nonfibrous Binder
10211079031 11/9/2012 M2.5A 1/1 Tan Mastic (100%)*** < 1% Chrysotile 99% Nonfibrous Binder
10211079032 11/9/2012 M2.5B 1/1 Brown Mastic <1% Chrysotile 99% Nonfibrous Binder
10211079033 11/9/2012 M2.5C 1/2 White Mastic (50%)*** None Detected 100% Nonfibrous Binder
2/2 Tan Mastic (50%) <1% Chrysotile 99% Nonfibrous Binder
10211079034 11/9/2012 M8.1A 1/1 Tan Mastic (100%)**** None Detected 5% Cellulose
95% Nonfibrous Binder dap Rectangle
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification and Estimated Quantity
10211079035 11/9/2012 M8.1B 1/1 Clear Mastic (100%)**** None Detected 5% Cellulose
95% Nonfibrous Binder
10211079036 11/9/2012 M8.1C 1/1 Clear Mastic (100%) None Detected 100% Nonfibrous Binder
10211079037 11/9/2012 F6.3A 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079038 11/9/2012 F6.3B 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079039 11/9/2012 F6.3C 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079040 11/12/2012 M2.4A 1/1 Brown Mastic (100%)*** None Detected 2% Cellulose
98% Nonfibrous Binder
10211079041 11/12/2012 M2.4B 1/1 Tan Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079042 11/12/2012 M2.4C 1/1 White Mastic (100%) None Detected 100% Nonfibrous Binder
10211079043 11/12/2012 M6.1A 1/1 White Green
Caulking (100%) Paint
None Detected 100% Nonfibrous Binder
10211079044 11/12/2012 M6.1B 1/1 White Green
Putty (100%) Paint
None Detected 100% Nonfibrous Binder
10211079045 11/12/2012 M6.1C 1/1 White Green
Caulking (100%) Paint
Trace Chrysotile 100% Nonfibrous Binder
10211079046 11/12/2012 F3.5A/F5.5A 1/5 Brown White
Linoleum (63%) Backing
None Detected 100% Nonfibrous Binder
2/5 Clear Mastic (2%) None Detected 100% Nonfibrous Binder
3/5 White Tile (15%) 12% Chrysotile 88% Nonfibrous Binder
4/5 Black Tile (15%) 8% Chrysotile 92% Nonfibrous Binder
5/5 Black Mastic (5%) None Detected 100% Nonfibrous Binder
10211079047 11/12/2012 F3.5B/F5.5B 1/5 Tan White
Linoleum (63%) Backing
None Detected 100% Nonfibrous Binder
2/5 Clear Mastic (2%) None Detected 100% Nonfibrous Binder
3/5 Hold - Not analyzed
4/5 Hold - Not analyzed
5/5 Black Mastic (5%) None Detected 100% Nonfibrous Binder
10211079048 11/12/2012 F3.5C/F5.5C 1/4 Brown White
Linoleum (93%) Backing
None Detected 100% Nonfibrous Binder
2/4 Clear Mastic (<1%) None Detected 100% Nonfibrous Binder
3/4 Hold - Not analyzed
4/4 White Mastic (1%) None Detected 100% Nonfibrous Binder
10211079049 11/12/2012 F3.6A/F5.6A 1/2 Tan White
Linoleum (99%) Backing
None Detected 100% Nonfibrous Binder
2/2 Clear Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079050 11/12/2012 F3.6B/F5.6B 1/2 Tan White
Linoleum (99%) Backing
None Detected 100% Nonfibrous Binder
2/2 Clear Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079051 11/12/2012 F3.6C/F5.6C 1/2 Tan White
Linoleum (99%) Backing
None Detected 100% Nonfibrous Binder
2/2 Clear Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079052 11/12/2012 F1.1A/F5.1A 1/2 White Linoleum (99%) None Detected 10% Cellulose
White Backing 5% Fibrous Glass
5% Synthetic Fibers
80% Nonfibrous Binder
2/2 Clear Gray
Mastic (<1%) Foam
None Detected 100% Nonfibrous Binder
10211079053 11/12/2012 F1.1B/F5.1B 1/2 White Linoleum (99%) None Detected 10% Cellulose
White Backing 5% Fibrous Glass
5% Synthetic Fibers
80% Nonfibrous Binder
2/2 Clear Gray
Mastic (<1%) Foam
None Detected 100% Nonfibrous Binder
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification and Estimated Quantity
10211079054 11/12/2012 F1.1C/F5.1C 1/2 White Linoleum (99%) None Detected 10% Cellulose
White Backing 5% Fibrous Glass
5% Synthetic Fibers
80% Nonfibrous Binder
2/2 Clear Gray
Mastic (<1%) Foam
None Detected 100% Nonfibrous Binder
10211079055 11/12/2012 M2.2A 1/1 Tan Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079056 11/12/2012 M2.2B 1/1 Tan Brown
Mastic (100%) Mastic
None Detected 100% Nonfibrous Binder
10211079057 11/12/2012 M2.2C 1/1 Tan Mastic (100%) None Detected 100% Nonfibrous Binder
10211079058 11/12/2012 M2.1A 1/1 White Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079059 11/12/2012 M2.1B 1/1 White Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079060 11/12/2012 M2.1C 1/1 White Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079061 11/12/2012 M2.3A 1/1 White Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079062 11/12/2012 M2.3B 1/1 White Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079063 11/12/2012 M2.3C 1/1 Tan Mastic (100%)*** None Detected 100% Nonfibrous Binder
10211079064 11/12/2012 F3.1A 1/2 White Tile (100%) None Detected 100% Nonfibrous Binder
2/2 Tan Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079065 11/12/2012 F3.1B 1/2 White Tile (100%) None Detected 100% Nonfibrous Binder
2/2 Tan Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079066 11/12/2012 F3.1C 1/2 White Tile (100%) None Detected 100% Nonfibrous Binder
2/2 Tan Mastic (<1%) None Detected 100% Nonfibrous Binder
10211079067 11/12/2012 F6.2A 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079068 11/12/2012 F6.2B 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
10211079069 11/12/2012 F6.2C 1/1 Tan Mastic (100%)** None Detected 100% Nonfibrous Binder
* Carpet/ rubber not analyzed.
** Carpet not analyzed.
*** Covebase not analyzed.
**** Wall panels not analyzed.
Michael Otness, analyst
In the case of nonhomogeneous samples (samples which contain more than one visually distinct material which is not mixed), concentrations of materials are given for each layer and, where applicable, composite values are given for the entire sample. The quantification of asbestos in the sample is an estimate only due to the nature of the test method.
Thomas, Dean & Hoskins, Inc.
1800 River Drive North Great Falls, MT 59401
Bulk Material Analysis - 12-270 Building 1705
DATE:
PACE PROJECT NO:
PAGE:
November 13, 2012
10211563
CASE NARRATIVE:
REPORT TO:
On November 7, 2012, our laboratory received 6 bulk material sample(s) from the client. The asbestos analysis was performed in accordance with EPA 600/M4-82-020 and EPA/600/R-93/116 official test methods as outlined in 40CFR763.109 appendix A.
The samples will be held for sixty (60) days from the date of this report.
A < sign indicates the value reported was the practical quantitation limit for this sample using the method described.
Concentrations of analyte, if present, below this were not quantifiable.
Pace Analytical Services, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for conducting asbestos analysis (NVLAP Lab Code 101292-0). Each result listed in the report applies only to the sample analyzed. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government nor may it be reproduced except in full without written approval of Pace Analytical Services, Inc.
Project Manager Analyst/Approved Signatory
Sarah Bleyer - Project Coordinator Michael Otness - Laboratory Analyst
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
Pace Analytical Services, Inc.
602 S 25th Street
Billings, MT 591014549
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
10211563001 11/12/2012 T2.1A 1/1 Gray Insulation (100%) None Detected 95% Cellulose
White Cloth 5% Synthetic Fibers
10211563002 11/12/2012 T2.1B 1/1 White Weave (100%) None Detected 15% Cellulose
Silver Foil 10% Fibrous Glass
5% Wollastonite
70% Nonfibrous Binder
10211563003 11/12/2012 T2.1C 1/1 White Weave (100%) None Detected 15% Cellulose
Silver Foil 25% Fibrous Glass
10% Wollastonite
50% Nonfibrous Binder
10211563004 11/12/2012 T4.1A 1/1 Black Cloth (100%) None Detected 100% Cellulose
10211563005 11/12/2012 T4.1B 1/1 Black Cloth (100%) None Detected 100% Cellulose
10211563006 11/12/2012 T4.1C 1/1 Black Cloth (100%) None Detected 100% Cellulose
Michael Otness, analyst
Non-Asbestos Material
Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date
Analyzed
Sample Description Asbestos Identification
Thomas, Dean & Hoskins, Inc.
1800 River Drive North Great Falls, MT 59401
Bulk Material Analysis - 12-270 Building 1705
DATE:
PACE PROJECT NO:
PAGE:
November 16, 2012
10211214
CASE NARRATIVE:
REPORT TO:
On November 2, 2012, our laboratory received 6 bulk material sample(s) from the client. The asbestos analysis was performed in accordance with EPA 600/M4-82-020 and EPA/600/R-93/116 official test methods as outlined in 40CFR763.109 appendix A.
The samples will be held for sixty (60) days from the date of this report.
A < sign indicates the value reported was the practical quantitation limit for this sample using the method described.
Concentrations of analyte, if present, below this were not quantifiable.
Pace Analytical Services, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for conducting asbestos analysis (NVLAP Lab Code 101292-0). Each result listed in the report applies only to the sample analyzed. This report may not be used to claim product endorsement by NVLAP or any agency of the U.S. Government nor may it be reproduced except in full without written approval of Pace Analytical Services, Inc.
Project Manager Analyst/Approved Signatory
Sarah Bleyer - Project Coordinator Michael Otness - Laboratory Analyst
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
Pace Analytical Services, Inc.
602 S 25th Street
Billings, MT 591014549
Pace Analytical Services, Inc.
Billings Laboratory
602 South 25th Street
Billings, MT 59101
Layers Color Matrix
10211214001 11/16/2012 R1.1A 1/4 Black Tarpaper (5%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (65%) None Detected 100% Nonfibrous Binder
3/4 White Fibrous (25%) None Detected 10% Fibrous Glass
White Solid 90% Nonfibrous Binder
4/4 Black Rubber (5%) None Detected 100% Nonfibrous Binder
10211214002 11/16/2012 R1.1B 1/4 Black Tarpaper (5%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (70%) None Detected 100% Nonfibrous Binder
3/4 White Fibrous (20%) None Detected 20% Fibrous Glass
White Solid 80% Nonfibrous Binder
4/4 Black Rubber (5%) None Detected 100% Nonfibrous Binder
10211214003 11/16/2012 R1.1C 1/4 Black Tarpaper (20%) None Detected 30% Fibrous Glass
70% Nonfibrous Binder
2/4 White Foam (35%) None Detected 100% Nonfibrous Binder 3/4 White Fibrous (30%) None Detected 20% Fibrous Glass
White Solid 80% Nonfibrous Binder
4/4 Black Rubber (15%) None Detected 100% Nonfibrous Binder
10211214004 11/16/2012 R1.2A 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
10211214005 11/16/2012 R1.2B 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
10211214006 11/16/2012 R1.2C 1/1 Black Shingle (100%) None Detected 20% Cellulose
Brown Granules 80% Nonfibrous Binder
Michael Otness, analyst
Non-Asbestos Material Identification
Sample Identification
Thomas, Dean & Hoskins, Inc.
12-270 Building 1705
Lab Number Date Analyzed
Sample Description Asbestos Identification
APPENDIX C
ASBESTOS SAMPLE
LOCATIONS
APPENDIX D
LEAD BASED PAINT
SAMPLE RESULTS
APPENDIX E
LEAD BASED PAINT
SAMPLE LOCATIONS
| COVER 1705 |
| 3--Project Manual Index 1705 |
| MAFB Bldg 1705 Asbestos_Lead Report 12-3-2012 |
File details come from the government source that posted it. Updated .