Attch_2_Submittal_Schedule.pdf
PDF 177 KB Posted
- Attached to
- MAF WATER WELL II Federal contract opportunity
- Solicitation number
- FA4626-19-R-A016
About this file
Attachment 2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| REPAIR_MAF_WATER_WELLS_II_QUESTIONS_2.pdf | ||
| REPAIR_MAF_WATER_WELLS_II_QUESTIONS_1.pdf | ||
| Amendment_MAF_Water_Wells_II.pdf | ||
| Attch_6_Installation_Perimeter_Access_Control.pdf | ||
| Attch_1_Specifications_Repair_MAF_Water_Wells.pdf | ||
| FA462619RA016.pdf | ||
| Attch_10_-_Section_L_&_M.pdf | ||
| Attch_9_Subcontractor_Consent.doc | DOC document | |
| Attch_7_Special_Contract_Requirements.docx | DOCX document | |
| Attch_2_Submittal_Schedule.pdf | ||
| Attch_4_Drawings_Part_A.pdf | ||
| Attch_5_Wage_Determinations.pdf | ||
| Attch_1_Specifications_Repair_MAF_Water_Wells.pdf | ||
| Attch_3_Schedule_of_Drawings.pdf | ||
| FA462619RA016.pdf | ||
| Attch_3_Schedule_of_Drawings.pdf | ||
| Attch_8_Past_Performance_Questionaire.docx | DOCX document | |
| Attch_4_Drawings_Part_B.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MALMSTROM AFB, MONTANA
SCHEDULE OF MATERIALS SUBMITTALS Project Number Project Title: Solicitation/Contract No.
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
R 'S
E C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
W
A R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
IN
G
ST
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
D
SU
B
M
IS
SI
O
N D
A T
(B Y
C
O N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
IV
IL
N
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
SE
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
L
FI
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
IS
P P
R O
V E
D
DIVISION 01 - GENERAL
REQUIREMENTS
1 01 00 00 General Requirements - 1.8A Contractor Design Drawings 3 30d PTSW
2 01 00 00 General Requirements - 1.8A Shop Drawings 3 30d PTSW
3 01 00 00 General Requirements - 1.8A Final As- Built Drawings 3 45d - AFI
4 01 00 00 General Requirements - 3.3A Schedule of Materials Submittal 3 10 d - ANP
5 01 00 00 General Requirements - 3.4A Manufacturer's Product Brochures & Catalog Data, Components and Materials to be Installed
4 30d -PTSW
6 01 00 00 General Requirements - 3.6D Overall Project Schedule 3 30d - PTSW
7 01 00 00 General Requirements - 3.8A Start of Work Notification 3 5 d - PTE
8 01 00 00 General Requirements - 3.11A Utility Outages 3 10d - PTE
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
AF Form 66 Submittal Schedule-2/20/2019
01330a-1
REQUIRED TECHNICAL SUBMITTALS
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
9 01 00 00 General Requirements - 3.13 Quality Control Plan and Specified Quality Control Submittals
3 10d - ANP
10 01 00 00 General Requirements - 3.16 As-Built Field Data 3 30d - AFI
11 01 00 00 General Requirements - 3.16D & 3.16 E As-Built Field Drawings 4 30d - AFI AutoCAD CD
12 01 00 00 General Requirements - 3.17 O&M Instructions/Manual 5 4 20d - AFI; 1
10d - PTFI 1 hardcopy, 2 CD's
13 01 00 00 General Requirements - 3.20C Size of Storage Area Requested 1 30d - PTSW
14 01 00 00 General Requirements - 3.23A Work Clearance Request (AF Form 103) 3 14d - PTSW AF Form 103 Work Clearance
15 01 00 00 General Requirements - 3.26 Nuclear Densometers 3 30d - PTSW
16 01 00 00 General Requirements - 3.28 Notice of Final Inspection 3 14d - PTE
Red line “As-Built” dwgs shall be provided by the Contractor at final inspection.
17 01 10 00 Site Security - 1.3 Contractor Entry
Authorization List (CEAL) 3 14d - PTSW EAL
18 01 10 00 Site Security - 1.8C Weekly Entry and Exit Times 1 7d - AE
19 01 36 00 Environmental Protection - 1.2.3 Copies of Environmental Permits 3 5d - AE
AF Form 66 Submittal Schedule-2/20/2019
01330a-2
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
20 01 36 00 Environmental Protection - 1.8.1.1 List of Hazardous Materials (1360-5) with MSDSs
3 30d - PTSW
21 01 36 00 Environmental Protection - 1.8.1.1 AF Form 3952 "Authorization Request Worksheets"
3 14d - PTSW
22 01 36 00 Environmental Protection - 1.8.1.4 Actual Hazardous Materials Used 3 30d - AFI
23 01 36 00 Environmental Protection - 1.11.6 Waste Management Plan 3 10d - PTFI
24 01 36 00 Environmental Protection - 1.12.5 Recycled Material Use Report 3 10d - PTFI
25 01 73 29 Cutting and Patching - 1.4A Cutting and Patching Proposal 3 15d - PTE
26 01 73 29 Cutting and Patching - 2.1 Patching Material Product Data 3 30d - PTSW
DIVISION 03 - CONCRETE
27 03 30 00 Cast-in-Place Concrete - 1.2A Shop Drawings 3 30d - PTSW
28 03 30 00 Cast-in-Place Concrete - 1.2B Concrete Mix Design Data 3 30d - PTSW
29 3 30 00 Cast-in-Place Concrete - 1.2C Test Reports 3 7d & 28d -
ATT
AF Form 66 Submittal Schedule-2/20/2019
01330a-3
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
30 3 30 00 Cast-in-Place Concrete - 1.2D Certificates 3 30d - PTSW
31 3 30 00 Cast-in-Place Concrete - 1.3B Installation Plan 3 30d - PTSW
DIVISION 05 - METALS
32 05 05 23 Metal Fastenings - 1.2A Procedure Specifications and Procedure Qualification Test Results
5 7d - ATT
33 05 05 23 Metal Fastenings - 1.2B Performance Qualifications of Welders and Welding Officers 3 30d - PTSW
34 05 05 23 Metal Fastenings - 1.2C Welder's Certificates 3 30d - PTSW
35 05 05 23 Metal Fastenings - 1.2E Welder's Record 3 30d - AFI
36 05 05 23 Metal Fastenings - 2.1 Electrodes Product Data 3 30d - PTSW
37 05 05 23 Metal Fastenings - 2.2 Stainless Steel Fastener Product Data 3 30d - PTSW
38 05 05 23 Metal Fastenings - 3.1D Written Welding Procedure for Well Casing 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-4
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
DIVISION 09 - PAINT
39 09 90 00 Paints and Coatings - 1.2 Shop Drawings 3 30d -PTSW
40 09 90 00 Paints and Coatings - 1.2 Product Certification 3 30d - PTSW
41 9 90 00 Paints and Coatings - 1.2 Product Materials 3 30d -PTSW
42 9 90 00 Paints and Coatings - 1.2 Manufacturer Tech Sheet 3 30d -PTSW
43 9 90 00 Paints and Coatings - 1.2 Color Samples 3 30d -PTSW
44 09 90 00 Paints and Coatings - 1.2 Certificates 3 30d - PTSW
45 9 90 00 Paints and Coatings - 1.2 Application Instructions 3 30d -PTSW
46 9 90 00 Paints and Coatings - 1.2 Manufacturer's Safety Data Sheets 3 30d -PTSW
47 9 90 00 Paints and Coatings - 1.2 Closeout Submittals 3 30d - AFI
48 09 90 00 Paints and Coatings - 1.3 Qualifications Data 3 30d -PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-5
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
DIVISION 22 - PLUMBING
49 22 05 53 Identification for Plumbing Piping and Equipment - 1.2 Product Data and Pipe Label Samples for Color, Letter Style, and Graphic Representation
3 3 30d - PTSW
50 22 05 53 Identification for Plumbing Piping and Equipment - 2.1 Pipe Label Product Data 3 30d - PTSW
51 22 11 00 Facility Water Distribution - 1.1A Detailed Plans of Departure from this Section 3 45d - PTSW
52 22 11 00 Facility Water Distribution - 1.2 Shop Drawings 3 30d - PTSW
53 22 11 00 Facility Water Distribution - 1.3 Certifications 3 30d - PTSW
54 22 11 00 Facility Water Distribution - 2.1 Pipe and Pipe Fittings Product Data 3 30d - PTSW
55 22 11 00 Facility Water Distribution - 2.3 RO Supply Pump 3 30d - PTSW
56 22 11 00 Facility Water Distribution - 2.4A Product Data for Isolation Valves 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-6
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
57 22 11 00 Facility Water Distribution - 2.4B Product Data for Check Valves 3 30d - PTSW
58 22 11 00 Facility Water Distribution - 2.4C Product Data for Throttling Valves 3 30d - PTSW
59 22 11 00 Facility Water Distribution - 2.4D Product Data for Vacuum Breaker Valves 3 30d - PTSW
60 22 11 00 Facility Water Distribution - 2.4E Product Data for Water Level Transducer 3 30d - PTSW
61 22 11 00 Facility Water Distribution - 2.4F Product Data for Other Minor Components 3 30d - PTSW
62 22 11 00 Facility Water Distribution - 2.11 Product Data for Water Storage Tank, Effluent Tank, and Tank Accessories
3 30d - PTSW
63 22 11 00 Facility Water Distribution - 2.5 Product Data for Electromagnetic Flow Meter - Water Treatment Equipment
3 30d - PTSW
64 22 11 00 Facility Water Distribution - 2.6 Product Data for Electromagnetic Flow Meter - Effluent Line Equipment
3 30d - PTSW
65 22 11 00 Facility Water Distribution - 2.7 Product Data for Sample Taps 3 30d - PTSW
66 22 11 00 Facility Water Distribution - 2.8 Product Data for Hose Bibs 3 30d - PTSW
67 22 11 00 Facility Water Distribution - 2.9 Product Data for Pipe Insulation 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-7
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
68 22 11 00 Facility Water Distribution - 2.10 Product Data for Garden Hose and Hanger 3 30d - PTSW
DIVISION 26 - ELECTRICAL
69 26 00 00 General Provisions for Electrical Work - 1.2.A. Qualifications 3 15d ANTP
70 26 05 19 Low Voltage Electrical Power Cables and Conductors - 1.4.A. Qualifications 3 15d ANTP
71 26 05 19 Low Voltage Electrical Power Cables and Conductors - 1.4.B. Quality control test reports
3 3d ATT
72 26 05 26 Grounding and Bonding for Electrical Systems - 1.3.A & B 3 3 15d ANTP
73 26 05 26 Grounding and Bonding for Electrical Systems - 1.3.C 3 3d ATT
74 26 05 33 Raceways and Boxes for Electrical Systems - 1.3. 3 3 15d ANTP
75 26 05 53 Identification for Electrical Systems -
1.3. Product Data 3 15d ANTP
76 26 29 13 Enclosed Controllers - 1.4.A. Product Data 3 15d ANTP
77 26 29 13 Enclosed Controllers - 1.4.B.1.
Tabulations 3 15d ANTP
AF Form 66 Submittal Schedule-2/20/2019
01330a-8
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
78 26 29 13 Enclosed Controllers - 1.4.B.2. Wiring Diagrams 3 15d ANTP
79 26 29 13 Enclosed Controllers - 1.4.C. O&M Data 3 3 PTFI
DIVISION 31 - EARTHWORK
80 31 00 00 Earthwork - 2.1 Borrow Material Product Data 3 30d - PTSW
81 31 00 00 Earthwork - 2.2 Backfill Product Data 3 30d - PTSW
82 31 00 00 Earthwork - 2.3A Field Density Testing Results 3 7d - ATT
83 31 00 00 Earthwork - 2.3B Moisture-Density Curves 3 30d - AFI
84 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 1.2A 3 30d - PTSW
85 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 1.3A Test Results for Pipe Bedding Sieve and Proctor, Pipe Bedding Compaction, Type A Trench Backfill Compaction, Type B Trench Backfill Compaction, and Controlled Low Strength Material
3 1d - ATT
AF Form 66 Submittal Schedule-2/20/2019
01330a-9
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
86 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 1.5 Written Statement of Method of Maintenance 3 30d - PTSW
87 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 1.8A Utility Notices
3 10d - PTSW
88 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.1 Type I Bedding Material Product Data
3 30d - PTSW
89 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.2 Type II Bedding Material Product Data
3 30d - PTSW
90 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.3 Pipe Bedding
3 30d - PTSW
91 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.4 Trench Backfill
3 30d - PTSW
92 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.6 Plastic Marking Tape
3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-10
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
93 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 2.7 Tracer Wire
3 30 d - PTSW
94 31 23 33 Trench Excavation and Backfill for Pipelines and Appurtenant Structures - 3.4 H.
Written Permission for Off-Site Disposal from Owner of Property upon which Material is to be Disposed
3 7d - PTSW
DIVISION 32 - EXTERIOR
IMPROVEMENTS
95 32 92 19 Seeding - 2.1 Certificate of Composition and Weed-Free Certification 3 30d - PTSW
96 32 92 19 Seeding - 2.2 Topsoil 3 30d - PTSW
97 32 92 19 Seeding - 2.3 Fertilizer 3 30d - PTSW
98 32 92 19 Seeding - 2.4 Fiber Mulch 3 30d - PTSW
99 32 92 19 Seeding - 3.4 Warranty 3 30d - PTSW
DIVISION 33 - UTILITIES
100 33 01 10.81 Well Abandonment - 1.1A Proof of Variance 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-11
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
101 33 01 10.81 Well Abandonment - 1.1B Well Abandonment Plan 3 30d - PTSW
102 33 01 10.81 Well Abandonment - 1.1C Well Abandonment Log 3 30d - AFI
103 33 01 10.81 Well Abandonment - 2.1 Bentonite Grout Product Data 3 30d - PTSW
104 33 14 16 Site Water Utility Distribution Piping -
2.1 HDPE Pipe Product Data 3 30d - PTSW
105 33 14 16 Site Water Utility Distribution Piping -
2.2 Product Data for PVC Pipe 3 30d - PTSW
106 33 14 16 Site Water Utility Distribution Piping - 2.3A Butt Fusion Fittings Product Data 3 30d - PTSW
107 33 14 16 Site Water Utility Distribution Piping - 2.3B Electrofusion Fittings Product Data 3 30d - PTSW
108 33 14 16 Site Water Utility Distribution Piping -
2.4 Marking 3 30d - PTSW
109 33 14 16 Site Water Utility Distribution Piping - 2.5B Closed Cell Foam Pipe Insulation Product Data
3 30d - PTSW
110 33 14 16 Site Water Utility Distribution Piping - 2.5B Rigid Insulation Product Data 3 30d - PTSW
111 33 14 16 Site Water Utility Distribution Piping - 3.5A Qualification of Master Plumber 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-12
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
112 33 21 00 Water Supply Wells - 1.2 All Necessary Permits and Certificates 3 3 7d - PTSW
113 33 21 00 Water Supply Wells - 1.4 Well Report 3 60d - ATT
114 33 21 00 Water Supply Wells - 1.7 Documentation of Competence 3 30d - PTSW
115 33 21 00 Water Supply Wells - 1.12 A.
Drawings, Diagrams, Etc. 3 3 30d - PTSW
116 33 21 00 Water Supply Wells - 1.12 B. Name of Laboratory Used for Water Sample Analysis 3 30d - PTSW
117 33 21 00 Water Supply Wells - 1.12 D.
Manufacturer's Certificates 3 30d - PTSW
117 33 21 00 Water Supply Wells - 1.12 E Qualification Statements of Subcontractors 3 30d - PTSW
118 33 21 00 Water Supply Wells - 1.12 G Drilling Equipment Product Data 3 30d - PTSW
118 33 21 00 Water Supply Wells - 1.12 H Closeout Submittals 3 30d - AFI
119 33 21 00 Water Supply Wells - 2.1 Drilling Fluids Product Data 3 30d - PTSW
120 33 21 00 Water Supply Wells - 2.2 Well Casing Product Data 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-13
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
121 33 21 00 Water Supply Wells - 2.3 Conductor Pipe Product Data 3 30d - PTSW
122 33 21 00 Water Supply Wells - 2.4 Well Screen Product Data 3 30d - PTSW
123 33 21 00 Water Supply Wells - 2.5 Sealing Grout Product Data 3 30d - PTSW
124 33 21 00 Water Supply Wells - 2.6 Well Pump Product Data 3 30d - PTSW
125 33 21 00 Water Supply Wells - 2.7 Pitless Unit Product Data 3 30d - PTSW
126 33 21 00 Water Supply Wells - 2.8 Well Cap Product Data 3 30d - PTSW
127 33 21 00 Water Supply Wells - 2.9 Drop Pipe Product Data 3 30d - PTSW
128 33 21 00 Water Supply Wells - 2.10 Check Valves Product Data 3 30d - PTSW
129 33 21 00 Water Supply Wells - 2.11 Torque Arrestor Product Data 3 30d - PTSW
130 33 21 00 Water Supply Wells - 2.12 Coupler Product Data 3 30d - PTSW
131 33 21 00 Water Supply Wells - 3.2A Drilling Fluid Properties Log 3 30d - AFI
132 33 21 00 Water Supply Wells - 3.3A Borehole Log 3 30d - AFI
133 33 21 00 Water Supply Wells - 3.4 Results of Water Sampling 3 60d - ATT
AF Form 66 Submittal Schedule-2/20/2019
01330a-14
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
134 33 21 00 Water Supply Wells - 3.5 Well Log 3 30d - AFI
135 33 21 00 Water Supply Wells - 3.6 Rate of Penetration Log 3 30d - AFI
136 33 21 00 Water Supply Wells - 3.7 Geophysical Log 3 30d - AFI
137 33 21 00 Water Supply Wells - 3.8 Stratigraphic Log 3 30d - AFI
138 33 21 00 Water Supply Wells - 3.14 Video Inspection 3 30d - AFI
139 33 21 00 Water Supply Wells - 3.15D Well Development Records 3 30d - AFI
140 33 21 00 Water Supply Wells - 3.15 C Hydraulic Slug Test Records and Reports 3 30d - AFI
141 33 21 00 Water Supply Wells - 3.16 Performance Testing Records and Reports 3 30d - AFI
142 33 31 13 Effluent Pressure Pipe - 2.2A Effluent Line Pump 3 30d - PTSW
AF Form 66 Submittal Schedule-2/20/2019
01330a-15
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
143 33 31 13 Effluent Pressure Pipe - 2.3A PVC Pipe 3 30d - PTSW
144 33 31 13 Effluent Pressure Pipe - 2.5A Precast Concrete Manhole Sections 3 30d- PTSW
145 33 31 13 Effluent Pressure Pipe - 2.5B Mahole Rings and Covers 3 30d - PTSW
146 33 31 13 Effluent Pressure Pipe - 2.5C Manhole Steps 3 30d- PTSW
147 33 31 13 Effluent Pressure Pipe - 2.5D Manhole Exterior Coating 3 30d - PTSW
148 33 31 13 Effluent Pressure Pipe - 2.5E Manhole Joints 3 30d- PTSW
149 33 31 13 Effluent Pressure Pipe - 2.7A Curb Stop 3 30d- PTSW
150 33 31 13 Effluent Pressure Pipe - 3.5 A Light Test 3 30d - AFI
AF Form 66 Submittal Schedule-2/20/2019
01330a-16
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
151 33 31 13 Effluent Pressure Pipe - 3.5 B Television Inspection 3 30d - AFI
152 33 31 13 Effluent Pressure Pipe - 3.5 C Leakage Test 3 30d - AFI
153 33 31 13 Effluent Pressure Pipe - 3.5 D Deflection Tests 3 30d - AFI
154 33 31 13 Effluent Pressure Pipe - 3.5 E Materials and Equipment for Testing 3 30d - AFI
155 33 38 10 Wastewater Disposal - 1.2 Permits, Certificates, Laws and Ordinances 3 3 30d - PTSW
156 33 38 10 Wastewater Disposal - 1.6 Licensed Septic Hauler 3 30d - PTSW
157 33 38 10 Wastewater Disposal - 1.7 Equipment Used to Perform the Work 3 30d - PTSW
158 33 38 10 Wastewater Disposal - 1.9 B Wastewater Laboratory Results 3 30d - PTSW
159 33 38 10 Wastewater Disposal - 1.9 C Disposal Paperwork 3 30d - PTSW
160 33 38 10 Wastewater Disposal - 1.9 D Name of Wastewater Treatment Plant 3 30d - PTSW
161 33 38 10 Wastewater Disposal - 1.9 E Letter from Wastewater Treatment Plant 3 30d - PTSW
162 33 38 10 Wastewater Disposal - 1.9 F Project Record Documents 3 30d - AE
AF Form 66 Submittal Schedule-2/20/2019
01330a-17
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
DIVISION 46 - WATER AND
WASTEWATER
EQUIPMENT
163 46 07 01 Water Treatment Equipment - 1.4E Modification Requirements 3 3 30 - PTB
164 46 07 01 Water Treatment Equipment - 1.5A Product Data for Sediment Filter, Carbon Filters, Zeolite Filter, RO System and Components, Calcite System, Hypochlorite Disinfection System, Charcoal Filter, Pressure Gauges, and All Appurtenances
3 30d - PTSW
165 46 07 01 Water Treatment Equipment - 1.5B Dimensions and Installation Requirements of Water Treatment Equipment 3 30d - PTSW
166 46 07 01 Water Treatment Equipment - 1.5C Proof of Experience of Manufacturer 3 30d - PTSW
167 46 07 01 Water Treatment Equipment - 1.5D Skid Design 3 3 30d - PTSW
168 46 07 01 Water Treatment Equipment - 1.5E Water Sample Results 3 30d - AFI
169 46 07 01 Water Treatment Equipment - 1.5F User's Manual for RO system 3 30d - AFI
AF Form 66 Submittal Schedule-2/20/2019
01330a-18
FA4626-19-R-A016
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTOR/ADMINISTRATOR
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C O
M
PL
IA
N
C E
SH
O
P D
R A
W
IN
G S
SA
M
PL
E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
FA
C
T U
R E
C
O M
M E
N D
A T
IO
N
S
M A
N U
FA
C
T U
R E
R
R A
N T
Y
C A
T A
L O
G D
A T
A
O
PE
R A
T
R U
C T
IO
N
S
N O
T
IF
IC
A
T
IO
N
O T
H E
R
R E
Q U
IR
M
IS
SI
O
N D
A
N
T R
A C
T O
R
D A
T E
R E
C E
IV
E
N
T R
A C
T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
SP
E
T
E
SU
B
M
IT
T A
L N
U M
B E
R S
C O
N T
R A
C T
SU
B M
IT
T
A L
A
PP
R O
V A
L
REMARKS
A P
P R
O V
E D
D
P
R O
V E
D
Number of Copies Required
NZAS 15-6000A
Repair MAF Water Wells B- 01, F-01, G-01, and L-01
DATE
CONTRACTOR
NOTIFIED
170 46 07 01 Water Treatment Equipment - 1.5F Shop Drawings, Manufacturer's Literature, Certificate of Compliance, Material Samples, Equipment Data, O&M Information, Guarantees, Electrical Schematics, Flow Diagrams, and Sequence of Operation
3 15 ANP
171 46 07 01 Water Treatment Equipment - 3.5 Instruction and Training 3 7d - ATT
AFI = After Final Inspection BD= Before Delivery ANP= After Notice to Proceed PTB= Prior To Bid ATT= After Test Taken PTE=Prior to Event AE= After Event
PTFI= Prior to Final Inspection BBCW= Before Beginning Concrete Work
PTSW= Prior to Start of Work
Schedule of Abbreviations:
AF Form 66 Submittal Schedule-2/20/2019
01330a-19
File details come from the government source that posted it.