Attachment 8 - AF IMT 813 Environmental Impact Analysis
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI___2,_Utility_&_Paving_DWG.PNG | PNG image | |
| RFI___2_Response_to_Questions.pdf | ||
| RFI___2_1245_C-2_Plot_Plan_with_Topo_Lines_-_1968.pdf | ||
| LPS_for_B475_RFI_Dwgs_28MAR17.zip | ZIP file | |
| 09-1371C_RFIs_28MAR17.pdf | ||
| Amend_02.pdf | ||
| LPS_Amend_02.pdf | ||
| 09-1371C_Site_Visit_Attendance_Roster.pdf | ||
| FA4610-17-R-0008-LPS.pdf | ||
| Amendment_1_to_09-1371C.pdf | ||
| Attachment_3_-_SB_County_WD_Mod_3_2017-02-17.pdf | ||
| Attachment_1_-__Statement_of_Work.pdf | ||
| Attachment_6_-_LPS_Design_Checklist.pdf | ||
| Attachment_7_-_General_Requirements.pdf | ||
| Attachment_2_-_30_CES_VAFB_LPS_Design_Guidelines.pdf | ||
| Attachment_5_-__Environmental_Specs.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
30 CES/CEIEA 30 CES CENMP 6062079
XUMU 09-1371C Construct Lightning Protection for Comm. Hub Bldg. 475.
Install new catenary lightning protection system for Bldg. 475. This is a mission critical comm. facility on a high hill which has no
LPS.
See page 2.
Richard Heslop 20161207
Report Control Symbol
RCS: REQUEST FOR ENVIRONMENTAL IMPACT ANALYSIS
INSTRUCTIONS: Section I to be completed by Proponent; Sections II and III to be completed by Environmental Planning Function. Continue on separate sheets as necessary. Reference appropriate item number(s).
SECTION I - PROPONENT INFORMATION
1. TO (Environmental Planning Function) 2. FROM (Proponent organization and functional address symbol) 2a. TELEPHONE NO.
3. TITLE OF PROPOSED ACTION
4. PURPOSE AND NEED FOR ACTION (Identify decision to be made and need date)
5. DESCRIPTION OF PROPOSED ACTION AND ALTERNATIVES (DOPAA) (Provide sufficient details for evaluation of the total action.)
6. PROPONENT APPROVAL (Name and Grade) 6a. SIGNATURE 6b. DATE
SECTION II - PRELIMINARY ENVIRONMENTAL SURVEY. (Check appropriate box and describe potential environmental effects + 0 U - Including cumulative effects.) (+ = positive effect; 0 = no effect; - = adverse effect; U= unknown effect)
7. AIR INSTALLATION COMPATIBLE USE ZONE/LAND USE (Noise, accident potential, encroachment, etc.)
8. AIR QUALITY (Emissions, attainment status, state implementation plan, etc.)
9. WATER RESOURCES (Quality, quantity, source, etc.)
10. SAFETY AND OCCUPATIONAL HEALTH (Asbestos/radiation/chemical exposure, explosives safety quantity-distance, bird/wildlife aircraft hazard, etc.)
11. HAZARDOUS MATERIALS/WASTE (Use/storage/generation, solid waste, etc.)
12. BIOLOGICAL RESOURCES (Wetlands/floodplains, threatened or endangered species, etc.)
13. CULTURAL RESOURCES (Native American burial sites, archaeological, historical, etc.)
14. GEOLOGY AND SOILS (Topography, minerals, geothermal, Installation Restoration Program, seismicity, etc.)
15. SOCIOECONOMIC (Employment/population projections, school and local fiscal impacts, etc.)
16. OTHER (Potential impacts not addressed above.)
SECTION III - ENVIRONMENTAL ANALYSIS DETERMINATION
17. PROPOSED ACTION QUALIFIES FOR CATEGORICAL EXCLUSION (CATEX) # ; OR
PROPOSED ACTION DOES NOT QUALIFY FOR A CATEX; FURTHER ENVIRONMENTAL ANALYSIS IS REQUIRED.
18. REMARKS
19. ENVIRONMENTAL PLANNING FUNCTION CERTIFICATION 19a. SIGNATURE 19b. DATE (Name and Grade)
THIS FORM CONSOLIDATES AF FORMS 813 AND 814.
PREVIOUS EDITIONS OF BOTH FORMS ARE OBSOLETE.
PAGE 1 OF PAGE(S) AF IMT 813, 19990901, V1
A2.3.8
10 Feb 2017 Tracy Curry, GS-12
Environmental Planner
Proposed Action qualifies for CATEX A2.3.8, which states "Performing interior and exterior construction within the 5 foot line of a building without changing the land use or the existing building." See attached comments for further Environmental requirements that need to be accomplished for this project.
CURRY-
BUMPASS.TRACY.L.130041511
Digitally signed by CURRY-BUMPASS.TRACY.L.1300415110 DN: c=US, o=U.S. Government, ou=DoD, ou=PKI, ou=USAF, cn=CURRY-BUMPASS.TRACY.L.1300415110 Date: 2017.02.16 13:27:48 -08'00'
Attachment 8 16 Feb 17
5. Description of Proposed Action and Alternatives.
Alternative 1) Install new caternary lightning protection system for building 475. This is the preferred option. Include surge arrestors for any antennas which do not currently have them. The site also has a propane tank which supplies fuel to a generator. If this is to remain, it will also need a small LPS.
Alternative 2) Install an LPS system on building 475 with air teminals mounted on the roof. Include surge arrestors for any antennas which do not currently have them. The site also has a propane tank which supplies fuel to a generator. If this is to remain, it will also need a small LPS.
V1
AF IMT 813, SEP 99, CONTINUATION SHEET
PAGE OF PAGE(S)
30 CES/CEIE ENVIRONMENTAL COMMENT FORM
DOCUMENT AUTHOR: 30 CEI Staff DOCUMENT TITLE: 813- COMMENTOR: Multiple DATE OF COMMENTS:
ITEM
NO. STAFF COMMENT
1 Ryan (Cultural) 805-605-0748
No cultural resources issues or concerns.
2 Evans (Natural) 805-606-4198
Trenching comments. OK
3 Lum (Wetlands) 805-606-5299
N/A
4 Harding(Air) 805-606-6863
See General construction comments below
5 Wiskowski (Clean Water Act – 401, 402) 805-606-7541
No concerns
6 Kalata (Drinking Water/Wastewater) 805-605-0342
No comments.
7 Naputi (Greenhouse gases/Ozone Depleting Substances/Tanks) 805-606-2068
No comments.
8 Narciso (Hazardous Materials) 805-605-7573
Contractors and sub-contractors must submit all hazardous materials including pesticides or herbicides with current Safety Data Sheet (SDS) for registration and approval thru HAZMART Environmental Support, Bldg 5500, Bay "C", Room 10, and telephone number
(805) 605-3870, 605-4786 or 605-7573. Current SDS must be a least earlier than five years old. References: AFI 32-7086, VAFB Air permit, EO 13423 and 40 CFR Part 372, Section 313.
9 Carson (Hazardous and Solid Waste) 805-606-2359
No comments or concerns.
10 Newberry (Installation Restoration Program/Military Munitions Response Program) 805-605-0408
Any ground penetrations require Weapons Safety coordination. No IRP concerns.
ITEM
NO. STAFF COMMENT
11 Naputi (asbestos/lead based paint) 805-606-62068
See attachments for information on asbestos in and around building 475
12 Kaisersatt/Curry (Coastal Zone Resources) 605- 0392/606-2044
The proponent for this action is responsible for implementing all applicable management requirements identified in the referenced Environmental comments attached. If the proponent is unable to accommodate these requirements, the proposed action will require additional environmental analysis and this CATEX will not apply.
Air Quality Comments General Construction Activities
1. Any portable equipment powered by an internal combustion engine with a rated horsepower of 50 bhp or greater used for this project must be registered in the California State-wide Portable Equipment Registration Program or have a valid Santa Barbara County Air Pollution Control District Permit to Operate. Examples of such equipment are portable generators, compressors and light-carts. Copies of each registration or permit along with fuel usage and hours of operation must be submitted to the 30 CES/CEIEC Air Quality section at the end of the project or by 15 January, whichever occurs first.
2. Off-road construction equipment must be compliant with all Federal, State and local regulations. A description of each piece of equipment to include make, model, serial number and rated brake- horsepower along with fuel usage and hours of operation must be provided to the 30 CES/CEIEC Air Quality section at the end of the project or by 15 January, whichever occurs first.
3. The following Santa Barbara County APCD Rules apply (copies of these rules can be obtained at www.sbcapcd.org or by contacting the 30 CES/CEIEC Air Quality Section):
201. Permits Required (contact 30 CES/CEIEC Air Quality Section to determine applicability)
302. Visible Emissions;
303. Nuisance;
304. Particulate Matter Northern Zone;
306. Dust and Fumes Northern Zone
311. Sulfur Content of Fuels
317. Organic Solvents
321. Solvent Cleaning Operations
323.1. Architectural Coatings
324. Disposal and Evaporation of Solvents
329. Cutback and Emulsified Asphalt Paving Materials
345. Control of Fugitive Dust from Construction and Demolition Activities
353. Adhesives and Sealants
4. Contractor must be enrolled in the Hazardous Material Pharmacy and all hazardous materials must be barcoded. Hazardous materials include paints, coatings, adhesives, sealants, solvents, asphalt, etc.
5. Abrasive blast materials must be certified by the California Air Resources Board. Total amount of abrasive material used must be submitted to the 30 CES/CEIEC Air Quality Section at the end of the project or by 15 January, whichever occurs first.
Standard Comments, Natural Resources Trenches and Pits
Animals including (but not limited to) the California red-legged frog are protected by the U.S. Endangered Species Act of 1973 (as amended).
“Harm” or “harassment” to these species is a violation of Federal law.
Trenches and pits must be maintained at the end of each work day to prevent wildlife from falling in; three options
Filled in at end of day Covered upon completion of work each day.
Dig or install “ramps” every 50 feet (a sloped cut or board or stick placed to allow animals to climb out)
In areas specifically identified by 30 CES/CEIEA as likely or known occupancy of threatened or endangered species, a biological monitor may be required. Monitor may or may not require pre-approval by 30 CES/CEI and/or the U.S. Fish and Wildlife Service, potentially including possession of a current section 10(a)(1)(A) recovery permit.
Rhys Evans 30 CES/CEIEA Natural Resources
(805) 606-4198
Vandenberg AFB Asbestos Inventory
Report Files: Assessment Area(s):
Facility Summary Report:
Status: Latitude:
Longitude:
Facility Manager:
Environ. Contact:
Phone:
Phone:
Occupied 34.609443
-120.562192
475Photo File Name:
Date Constructed: Square Footage:1964 21,134
Facility Number: Facility Name:475 Msl/Space Rsch Tst
Facility Owner: InDyne, Inc. / WROCI
23 homogeneous sampling areas were identified and 82 samples were collected. Assessment Area A. Administrative Area: 8 Miscellaneous Materials were suspected of containing asbestos; no TSI or Surfacing Material were suspected. Assessment Area B. Communication Room/Television Area: 10 Miscellaneous Materials were suspected of containing asbestos; no TSI or Surfacing Material were suspected. Assessment Area C. Mechanical Room: 2 TSIs were suspected of containing asbestos; no Surfacing or Miscellaneous Material were suspected. Assessment Area D. Boiler Room: No asbestos detected. Assessment Area E. Exterior: 1 TSI and 1 Miscellaneous Material were suspected of containing asbestos; no TSI were suspected.
ID: Location(s):
A Administrative Area
B Communication Room/TV Area
C Mechanical Room D Boiler Room
E Exterior
Asbestos Containing Material (ACM) Results:
Area ID HSA ID: HSA Type: % Asb. Type:Year:
001 7%9 in. x 9 in. Beige Floor Tile ChrysotileA 1995
002 10%Mastic Beneath Beige Floor Tile ChrysotileA 1995
003 3%9 in. x 9 in. Tan Floor Tile ChrysotileA 1995
004 5%Mastic Beneath Tan Floor Tile ChrysotileA 1995
005 0%12 in. x 12 in. Cream Floor Tile None DetectedA 1995
006 0%Mastic Beneath Beige Tile None DetectedA 1995
007 0%9 in. x 9 in. Green Floor Tile None DetectedA 1995
008 1%Mastic Beneath Green Floor Tile ChrysotileA 1995
012 2%12 in. x 12 in. White Floor Tile, Raised Floor ChrysotileB 1995
013 15%Mastic Beneath White Floor Tile ChrysotileB 1995
014 2%1 ft. x 1 ft. Acoustical Tile with Small Holes AmositeB 1995
015 0%2 ft. x 4 ft. Ceiling Tile w/Small Holes None DetectedB 1995
016 0%2 ft. x 4 ft. Fissured Ceiling Tile None DetectedB 1995
017 0%12 in. x 12 in. Tan Floor Tile None DetectedB 1995
018 0%Wallboard None DetectedB 1995
019 1-10%9 in. x 9 in. Camel/Brown Floor Tile ChrysotileB 1995
020 1-10%Mastic Beneath Camel/Brown Floor Tile ChrysotileB 1995
021 0%2 ft. x 2 ft. Fissured Ceiling Tile None DetectedB 1995
009 0%Lagging Over Pipe Insulation None DetectedC 1995
011 20%Fittings on Water Piping ChrysotileC 1995
018 0%Wallboard None DetectedC 1995
Bldg475B.PDF bldg475.pdf
Bldg475.pdf
00475_635.TIF
Reference: Volume 3, Pacific Environmental Services, Inc., April 1993.
000 0%None Suspected None DetectedD 1995
022 40%Transite Panels ChrysotileE 1995
023 0%Pipe Insulation Debris None DetectedE 1995
File details come from the government source that posted it. Updated .