About this file

Attachment 1- Statement of Work

View the file

Other files for this federal contract opportunity

Other files attached to B4565 Renovation for A6/A9, newest first.
File Type Posted
Questions_1-22-.pdf PDF
Questions_1-21-.pdf PDF
Anticipated_parking_and_lay_down_areas.pdf PDF
Attachment_12-_SPEc_section_075216.pdf PDF
Amendment__1.pdf PDF
Prebid_Attendance_Sheet.pdf PDF
Attachment_8_-_Past_Performance_Questionnaire.pdf PDF
Attachment_9_-_Wage_Determination_LA170034.pdf PDF
Attachment_4_-_AF66.pdf PDF
Attachment_3_-_Environmental_Req'ts_(Jun_16).pdf PDF
Attachment_6_-_Special_Contract_Requirements.pdf PDF
Attachment_5-_Insurance_Form.pdf PDF
Attachment_10_-_Specs_5-1-17.pdf PDF
Attachment_11_-_Water_flow_5-1-17.pdf PDF
Attachment_7_-_PPQ_Letter.pdf.pdf PDF
Attachment_2_-drawing_5-1-17.pdf PDF
FA4608-17-R-0013_Solicitation_A6-A9_.pdf PDF
Attendance_Sheet.pdf PDF
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINAL STATEMENT OF WORK

RENOVATE BUILDING 4565 FOR A6 AND A9

PROJECT NO. AWUB 16-0040

14 APRIL 2017

1. A SYNOPSIS OF THE SCOPE OF THE WORK IS AS FOLLOWS:

THE CONTRACTOR SHALL RENOVATE THE FORMER AIR OPERATIONS CENTER

SPACES AT BUILDING 4565, BARKSDALE AIR FORCE BASE, LOUISIANA, TO HOUSE

ADMINISTRATIVE FUNCTIONS FOR AFGSC A6; AND ADMINISTRATIVE AND

TRAINING FUNCTIONS FOR AFGSC A9. THE APPROXIMATE NET AREA TO BE

RENOVATED IN THESE SPACES IS 20,000 SQUARE FEET. THE A6 AND A9 SPACES AND

COMMON AREAS (RESTROOMS, MECHANICAL ROOM, AND VESTIBULES) OCCUPY

APPROXIMATELY 7,000; 10,700; AND 2,300 SQUARE FEET, RESPECTIVELY. ALL A6

SPACES SHALL BE SECURE OPEN STORAGE WITH SIPRNET RECEPTACLES

SCATTERED THROUGHOUT. A CYBER CAFÉ SHALL BE CONSTRUCTED FOR SIPRNET

SERVICES IN THE A9 SPACES.

EXISTING RAISED (ACCESS) FLOORING COVERS APPROXIMATELY 15,000 SQUARE

FEET OF THE OVERALL FLOOR AREA. APPROXIMATELY 1,800 SQUARE FEET OF

RAISED FLOORING SHALL BE REMOVED. OF THE 13,200 SQUARE FEET REMAINING,

APPROXIMATELY 1,800 SQUARE FEET SHALL BE REMOVED AND THEN RELOCATED

TO LOWER TO ITS ELEVATION TO 1’-0” ABOVE THE EXISTING CONCRETE SLAB (IN

ORDER TO BE AT THE SAME LEVEL AS THE REST OF THE RAISED FLOORING). THE

CONTRACTOR SHALL REUSE EXISTING RAISED FLOOR COMPONENTS AS MUCH AS

POSSIBLE AND AUGMENT THE NEEDED BALANCE WITH NEW, MATCHING

COMPONENTS.

THE EXISTING CEILINGS (AND ASSOCIATED LIGHT FIXTURES) ABOVE THE RAISED

FLOORS TO REMAIN SHALL, WITH EXCEPTIONS, REMAIN.

OTHER FEATURES UNDER THIS CONTRACT INCLUDE: REPAINTING OF PREVIOUSLY

PAINTED WALLS IN ALL A6 AND A9 SPACES AND COMMON AREAS, REPLACEMENT

OF EXTERIOR AND INTERIOR DOORS AND ASSOCIATED FRAMES AND HARDWARE,

RUBBER BASE, AND CHAIR RAILING IN CONFERENCE ROOMS.

THREE AREAS WITH A COMPOSITE AREA OF 5,500 SQUARE FEET SHALL UNDERGO

EXTENSIVE SPATIAL RECONFIGURATION (DEMOLITION OF EXISTING PARTITIONS

AND CONSTRUCTION OF NEW FINISHED PARTITIONS; NEW FLOORING AND

CEILING FINISHES; NEW DOORS, FRAMES, AND HARDWARE; NEW ELECTRICAL

RECEPTACLES AND RECONFIGURED CIRCUITRY; RELOCATED LIGHT FIXTURES;

AND REARRANGEMENT OF EXISTING HVAC COMPONENTS). THESE AREAS SHALL

ALSO RECEIVE NEW FIRE SUPPRESSION SPRINKLER HEADS.

OTHER AREAS SHALL BE PARTITIONED TO CREATE CLASSROOMS, STUDY AREA,

AND ADMINISTRATIVE ROOMS. THE EXISTING RESTROOMS SHALL BE RENOVATED,

INCLUDING NEW CEILINGS AND FLOORING, NEW TOILET COMPARTMENTS AND

FA4608-17-R-0013

Attachment 1

ACCESSORIES, AND NEW PLUMBING FIXTURES. SEAPARATE BREAKROOMS FOR A6

AND A9 SHALL BE PROVIDED.

THE CONTRACTOR SHALL REPLACE EXISTING MECHANICAL EQUIPMENT WITH

NEW, INCLUDING 275 TON CHILLER, TWO (2) ROOFTOP AIR HANDLING UNITS (EACH

17,500 CFM), AND HOT- AND CHILLED-WATER PUMPS.

THE COMMUNICATIONS SYSTEM SHALL BE COMPLETELY REVAMPED THROUGHOUT

THE A6 AND A9 SPACES. EXISTING NIPRNET AND SIPRNET CABLES AND

RECEPTACLES SHALL BE REMOVED AND NEW CABLES AND RECEPTACLES

PROVIDED. SIPR AND NIPR COMMUNICATIONS ROOMS SHALL BE CREATED TO

HOUSE RACKS AND SERVERS. VIDEO TELECONFERENCING SHALL BE PROVIDED IN

EACH OF THE TWO CONFERENCE ROOMS AND THE AUDITORIUM.

THE FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL BE UPDATED THROUGHOUT

THE ENTIRETY OF BUILDING 4565, INCLUDING THE ADJACENT NC3 SPACES (WITH A

NET AREA OF 31,800 SQUARE FEET). PROVIDE NEW ADDRESSABLE ITEMS (FIRE

ALARM CONTROL PANEL, WALL- AND CEILING-MOUNTED SPEAKER STROBES, DUCT

DETECTORS, AND SMOKE DETECTORS (UNDER THE RAISED FLOOR)); AND EQUIP

EXISTING PULL STATIONS WITH MINI-MODULES FOR CONVERSION TO

ADDRESSABLE.

INTRUSION DETECTION SYSTEMS SHALL BE PROVIDED IN THE A6 SPACES, THE A9

CYBER CAFÉ, AND THE SIPRNET COMMUNICATIONS ROOM. COMPONENTS SHALL

INCLUDE ALARMED DOORS, ELECTRIC DOOR STRIKES (EXCEPTING THE SIPRNET

COMMUNICATIONS ROOM), CEILING-MOUNTED MOTION SENSORS, AND CONTROL

UNITS.

THE EXISTING SINGLE-PLY ROOF SHALL BE REMOVED OVER THE ENTIRETY OF

BUILDING 4565. THE EXISTING POURED GYPSUM DECK SHALL REMAIN AND BE

PATCHED AS REQUIRED. A NEW ROOF ASSEMBLY, INCLUDING SINGLE-PLY

MEMBRANE OVER BOARD INSULATION, SHALL BE PROVIDED. NEW EQUIPMENT

CURBS AND RAISED EDGING SHALL ALSO BE PROVIDED.

2. THE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE INSTRUCTIONS

HEREIN, OTHER CRITERIA CONTAINED IN THE CONTRACT, AND THE FOLLOWING

DRAWING SHEETS (ATTACHED):

GENERAL:

G01 GENERAL NOTES, INTRUSION DETECTION SYSTEM (IDS) REQUIREMENTS,

SECURE OPEN STORAGE (SOS) BOUNDARY PLAN, & INDEX TO DRAWINGS

ARCHITECTURAL:

A01 DEMOLITION FLOOR PLAN

A02 DEMOLITION REFLECTED CEILING PLAN

A03 FLOOR PLAN – NEW CONSTRUCTION

A04 REFLECTED CEILING PLAN – NEW CONSTRUCTION

A05 FINISH SCHEDULE

FA4608-17-R-0013

A06a OPENING SCHEDULE A06b SIGN SCHEDULE

A07 RAMP AND CABINETRY DETAILS

A08 FURNITURE PLAN

A09 INTERIOR ELEVATIONS

A10 DEMOLITION ROOF PLAN (RELEASE PENDING)

A11 ROOF PLAN – NEW CONSTRUCTION (RELEASE PENDING)

MECHANICAL:

M01 DEMOLITION MECHANICAL SITE & ROOF PLANS

M02 MECHANICAL SITE & ROOF PLANS – NEW CONSTRUCTION

M03 DEMOLITION MECHANICAL PLAN

M04 MECHANICAL PLAN – NEW CONSTRUCTION

FIRE ALARM SYSTEM:

FA01 DEMOLITION FIRE ALARM/MASS NOTIFICATION PLAN

FA02 FIRE ALARM/MASS NOTIFICATION PLAN – NEW CONSTRUCTION

FA03 DEMOLITION FIRE ALARM/MASS NOTIFICATION PLAN – NC3 SPACES

FA04 FIRE ALARM/MASS NOTIFICATION PLAN – NEW CONSTRUCTION – NCS SPACES

ELECTRICAL:

E01 DEMOLITION POWER PLAN

E02 POWER PLAN – NEW CONSTRUCTION

COMMUNICATIONS:

Co01 DEMOLITION COMMUNICATIONS PLAN Co02 COMMUNICATIONS PLAN – NEW CONSTRUCTION

3. SEE DRAWING SHEETS A02 AND A04 FOR DEMOLITION AND NEW CONSTRUCTION

WORK TO BE PERFORMED FOR ELECTRICAL SWITCHES IN SELECT LOCATIONS.

4. UNLESS ITEMS ARE INDICATED ON DRAWINGS TO BE “EXISTING”, “SALVAGED”,

“REINSTALLED”, “RELOCATED”, OR “REUSED”, ALL ITEMS SHALL BE REGARDED AS

NEW, WHETHER NOTED AS “NEW” OR NOT.

5. THE GOVERNMENT-FURNISHED, GOVERNMENT-INSTALLED MODULAR

WORKSTATIONS AND OTHER FURNITURE AND EQUIPMENT ITEMS SHOWN ON

DRAWING SHEET A08 AND ELSEWHERE IN THE DRAWINGS ARE INCLUDED FOR

PURPOSES OF INFORMATION AND ASSISTANCE TO THE CONTRACTOR IN LOCATING

CONTRACTOR-PROVIDED ITEMS. UNLESS OTHERWISE NOTED, THE CONTRACTOR

SHALL PERFORM ALL OTHER WORK AND PROVIDE OTHER ITEMS INDICATED IN

THIS STATEMENT OF WORK.

6. THE CONTRACTOR SHALL PROTECT FROM DAMAGE ALL EXISTING

CONSTRUCTION TO REMAIN.

7. ALL DIMENSIONS SHOWN ARE FOR BIDDING PURPOSES ONLY. THE CONTRACTOR

SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO ANY FIELD

FA4608-17-R-0013

WORK. FAILURE OF THE CONTRACTOR TO FIELD VERIFY DIMENSIONS AND

CONDITIONS WHICH RESULT IN ILL-FITTING OR OTHERWISE UNSUITABLE

CONSTRUCTION ITEMS THAT MUST BE ALTERED OR REPLACED SHALL NOT BE

CAUSE FOR ADDITIONAL CHARGES TO THE GOVERNMENT. THE CONTRACTOR

SHALL PERFORM THE ALTERATION AND REPLACEMENT WORK TO THE

SATISFACTION OF THE CONTRACTING OFFICER.

8. ANY CONTRACTOR-PROPOSED DEVIATION FROM THE STATEMENT OF WORK

DUE TO OSTENSIBLY DIFFERING FIELD CONDITIONS SHALL BE SUBMITTED IN

WRITING TO THE CONTRACTING OFFICER. THE CONTRACTOR SHALL RECEIVE

WRITTEN INSTRUCTIONS FROM THE CONTRACTING OFFICER PRIOR TO

COMMENCING ANY WORK THAT DIFFERS FROM THAT SHOWN IN THE STATEMENT

OF WORK.

9. THE CONTRACTOR SHALL PAINT ANY EXPOSED, NON-FACTORY FINISHED

COMPONENT, SUCH AS CONDUIT, TO MATCH THE SUBSTRATE FINISH TO THE

SATISFACTION OF THE CONTRACTING OFFICER.

10. ANY NEW CONSTRUCTION ITEMS, UNLESS INDICATED TO BE GOVERNMENT-

FURNISHED AND/OR GOVERNMENT-INSTALLED, SHALL BE CONTRACTOR-

FURNISHED AND CONTRACTOR-INSTALLED.

11. “PROVIDE” = “FURNISH AND INSTALL”

12. THE CONTRACTOR SHALL PERFORM THE NECESSARY FIELD VERIFICATIONS TO

ENSURE THAT THE DEMOLITION AND/OR NEW CONSTRUCTION WORK THAT HE

PERFORMS DOES NOT ADVERSELY AFFECT THE PROPER FUNCTIONING OF THE

EXISTING CONSTRUCTION TO REMAIN IN THE PROJECT AREA OR IN OTHER AREAS

OF BUILDING 4565. IF THE CONTRACTOR’S WORK DOES ADVERSELY AFFECT ANY

PART OF THE EXISTING CONSTRUCTION TO REMAIN, HE SHALL PERFORM THE

CORRECTIVE ACTIONS REQUIRED TO RESTORE, TO THE SATISFACTION OF THE

CONTRACTING OFFICER, THE PROPER FUNCTIONING OF THE AFFECTED EXISTING

CONSTRUCTION TO REMAIN. ANY CORRECTIVE WORK REQUIRED OF THE

CONTRACTOR TO REPAIR EXISTING CONSTRUCTION THAT HE FAILED TO PROTECT

SHALL BE DONE AT NO ADDITIONAL COST TO THE GOVERNMENT.

13. THE CONTRACTOR SHALL CONDUCT TESTS REQUIRED TO SHOW THAT ALL THE

FIXTURES, EQUIPMENT, AND SYSTEMS THAT HE PROVIDED (OR INSTALLED) UNDER

THIS CONTRACT PERFORM IN A FULLY OPERATIONAL AND SATISFACTORY

MANNER. THE CONTRACTOR MUST HAVE IN HAND THE GOVERNMENT-APPROVED

OPERATIONS AND MAINTENANCE MANUALS APPLICABLE TO THE FIXTURE,

EQUIPMENT, OR SYSTEM BEING TESTED BEFORE HE MAY SCHEDULE THE

ASSOCIATED TEST. THE CONTRACTOR SHALL PROVIDE THE GOVERNMENT

REPRESENTATIVE WITH A WRITTEN INVITATION TO WITNESS EACH TEST AT LEAST

72 HOURS PRIOR TO THE TEST’S SCHEDULED PERFORMANCE. THE CONTRACTOR

SHALL ENSURE THAT ANY REQUIRED MANUFACTURER’S REPRESENTATIVE IS ALSO

PRESENT AT THE TEST. IF THE CONTRACTOR CONDUCTS THE TEST WITHOUT THE

REQUIRED MANUFACTURER’S REPRESENTATIVE BEING PRESENT OR WITHOUT THE

FA4608-17-R-0013

GOVERNMENT REPRESENTATIVE BEING THERE TO WITNESS (UNLESS INFORMED

BY THE GOVERNMENT REPRESENTATIVE IN WRITING TO PROCEED WITHOUT HIM),

THE CONTRACTOR SHALL REACCOMPLISH THE TEST AT NO ADDITIONAL COST TO

THE GOVERNMENT. THE WARRANTY START DATE FOR THE TESTED FIXTURE,

EQUIPMENT, OR SYSTEM IS THE DATE THAT THE TEST IS SUCCESSFULLY

CONDUCTED, MEETS THE CONDITIONS ABOVE, AND IS VALIDATED AS SUCH IN

WRITING BY THE CONTRACTING OFFICER OR HIS REPRESENTATIVE.

14. THE CONTRACTOR SHALL PROVIDE THE SUBMITTALS BELOW AS DIRECTED BY

THE CONTRACTING OFFICER. SUBMITTALS DESIGNATED AS “FIO” ARE FOR

INFORMATION ONLY WHILE THOSE DESIGNATED “GA” REQUIRE GOVERNMENT

APPROVAL. THE CONTRACTOR SHALL PROVIDE NUMBER OF COPIES AS PRESCRIBED

FOR EACH OF THE FOLLOWING SUBMITTALS.

PRODUCT DATA SHALL BE SUBMITTED FOR THE FOLLOWING (PROVIDE FOUR (4)

COPIES):

CONCEALED CABINET DOOR HINGES, FIO;

CABINETRY PLYWOOD, FIO;

WOOD CHAIR RAILING, FIO;

COMMUNICATIONS ROOMS’ PLYWOOD, FIO;

1x WOOD STILE MATERIAL, FIO;

CABINET DOOR PULLS, FIO;

DUAL DRAWER GUIDES, FIO;

BREAK ROOM SINKS, GA;

LAVATORIES (BATHROOM SINKS), GA;

FAUCETS, GA;

UNDER-LAVATORY PIPE COVER/PROTECTOR, FIO;

TANKLESS ELECTRIC WATER HEATER, GA;

UPRIGHT ELECTRIC WATER HEATER, GA;

WATER CLOSETS, GA;

URINALS, GA;

FLUSH VALVES FOR WATER CLOSETS AND URINALS, GA;

WATER COOLER, GA;

DRAINAGE PIPING AND FITTINGS, FIO;

COPPER WATER PIPING AND SLEEVE INSULATION, FIO;

TOILET ACCESSORIES, FIO;

MIRRORS, FIO;

PLUMBING FITTINGS AND PIPING, FIO;

EXPANDING FOAM SEALANT, FIO;

FIRE STOP PILLOWS, FIO;

ELECTRICAL DISCONNECTS, GA;

ELECTRICAL DUPLEX RECEPTACLES, FIO;

ELECTRICAL QUAD RECEPTACLES, FIO;

ELECTRICAL SINGLE-POLE SWITCHES, FIO;

ELECTRICAL THREE-WAY SWITCHES, FIO;

DIMMING SWITCHES, FIO;

ELECTRICAL COVER PLATES, FIO;

CONDUIT, FIO,

FA4608-17-R-0013

POWER WIRING, FIO;

SIPERNET AND NIPERNET WIRING, GA;

WIRE/CABLE TRAYS, GA;

TOILET PARTITIONS AND ASSOCIATED HARDWARE, GA;

SOLID CORE WOOD DOORS (SHOWING PREPARATION FOR HARDWARE), GA;

INSULATED HOLLOW METAL DOORS (SHOW PREPARATION FOR HARDWARE), GA;

HOLLOW METAL FRAMES, GA;

VISION LITES (GLASS AND FRAMES), GA;

CLOSERS, GA;

CYLINDER LOCKS, GA;

HINGES, GA;

WALL STOPS, GA;

FLOOR STOPS, GA;

SILENCERS, GA;

KICKPLATES, GA;

CONCEALED FLUSH BOLTS, GA;

EXIT DEVICES, GA;

EXIT DEVICES WITH DEADBOLT EGRESS HARDWARE, GA;

OVERHEAD RAIN DRIPS, GA;

BALANCED MAGNETIC SWITCH SENSORS, GA;

MOUNTING BRACKETS, GA;

5/8” FIRE-RATED GYPSUM BOARD, GA;

2 ½” AND 3 5/8” STEEL STUDS, FIO;

4”, 6”, AND 8” LIGHTWEIGHT CMU’s, FIO;

TYPE “S” MORTAR, FIO;

GROUT MIX, FIO;

STAIN, FIO;

POLYURETHANE, FIO;

RUBBER BASE, GA;

PAINT, GA;

CMU BLOCK FILLER, GA;

POURED GYPSUM MIX, REINFORCEMENT MESH, AND FORMBOARD, FIO;

FIBERBOARD ACOUSTICAL LAY-IN CEILING PANELS, GA;

FIBERGLASS ACOUSTICAL LAY-IN CEILING PANELS, GA;

LAY-IN CEILING GRID, GA;

MINI-BLINDS (AT SELECT DOORS), FIO;

CHILLER, GA;

ROOFTOP AIR HANDLING UNITS, GA;

CHILLED WATER PUMPS, GA;

HOT WATER PUMPS, GA;

BOILERS, GA;

SIPERNET RECEPTACLES, GA;

SIPERNET FIBER OPTIC CABLE, GA;

SC TYPE CONNECTORS, GA;

SPLIT 50 66 BLOCKS, GA;

NIPERNET RECEPTACLE, GA;

PATCH PANELS. GA;

INTERIOR SIGNAGE, GA;

FA4608-17-R-0013

SIGNAGE SCHEDULE, GA;

SOLID SURFACING COUNTERTOP, FIO;

RAISED FLOOR PANELS, GA;

RAISED FLOOR EXPOSED GRID, GA;

RAISED FLOOR SUPPORTS, GA;

SUPPLY- AND RETURN-AIR GRILLES AND BOOTS, FIO;

FIRE ALARM CONTROL PANEL AND INTERNAL APPURTENANCES, GA;

WALL- AND CEILING-MOUNTED SPEAKER STROBES, GA;

FIRE ALARM CONTROL AND MINI-MODULES, GA;

SMOKE DETECTORS (UNDERFLOOR AND DUCT) AND APPURTENANCES, GA;

REMOTE INDICATORS, GA;

LOCAL OPERATOR CONSOLES, GA;

MASS NOTIFICATION SYSTEM PANEL AND INTERNAL APPURTENANCES, GA;

FLOOR BOXES (ELECTRICAL POWER AND NIPERNET RECEPTACLES), GA;

FLOOR BOXES (ELECTRICAL POWER, NIPERNET, AND SIPRNET RECEPTACLES), GA;

FLOURESCENT LIGHT TROFFERS, GA;

FLUORESCENT LIGHT TROFFERS WITH EMERGENCY BALLASTS, GA;

FLUORESCENT STRIP LIGHT FIXTURES, FIO;

FLUORESCENT AND LED LAMPS, GA;

DIMMABLE RECESSED CAN LIGHT FIXTURES; GA;

EXIT SIGNS, GA;

SLC CABLE, GA;

ELECTRIC STRIKE AND TRANSFORMER, GA;

AECS KEYPAD, GA;

IDS KEYPAD, GA;

IDS CONTROL UNIT AND INTERNAL APPURTENANCES, GA; AND

IDS MOTION SENSORS, GA.

COLOR SAMPLES SHALL BE SUBMITTED FOR THE FOLLOWING (PROVIDE TWO (2)

SAMPLES):

DOOR AND MILLWORK STAIN, GA;

MINI-BLINDS, GA;

CARPET, GA;

VINYL COMPOSTION TILE, GA;

PORCELAIN FLOOR TILE, GA;

CERAMIC WALL TILES, GA.

RUBBER BASE, GA;

INERIOR SIGNAGE, GA;

SOLID SURFACING COUNTERTOP, GA;

PAINT, GA;

RAISED FLOOR PANELS, GA; AND

RAISED FLOOR EXPOSED SUPPORT FRAME/GRID, GA.

OPERATIONS AND MAINTENANCE MANUALS (ALL GA) SHALL BE SUBMITTED FOR

THE FOLLOWING (PROVIDE FOUR (4) COPIES):

FIRE SUPPRESSION SYSTEM;

COMBINATION FIRE ALARM/MASS NOTICATION SYSTEM, INCLUDING SMOKE

DETECTION;

FA4608-17-R-0013

INTRUSION DETECTION SYSTEM;

MECHANICAL HVAC SYSTEM, INCLUDING CONTROLS; AND

PLUMBING FIXTURES.

SHOP DRAWINGS (ALL GA) SHALL BE SUBMITTED FOR THE FOLLOWING (PROVIDE

FOUR (4) HARDCOPIES AND ONE (1) SET OF CAD DRAWING FILES):

STEEL ANGLE LINTELS;

TOILET STALLS/COMPARTMENTS LAYOUT PLAN;

SECURITY GRILLES AND THROUGH-WALL ENCLOSURES;

DUCT TRANSITIONS AT SECURITY GRILLE ENCLOSURES;

FLOOR BOXES’ LAYOUT PLAN AT RAISED FLOOR;

CABINETRY FOR BREAK ROOMS AND PHONE STORAGE;

CABLE TRAY LAYOUT AND NIPERNET AND SIPRNET CABLE ROUTING PLANS;

ALUMINUM GUARDRAILS AND HANDRAILS;

RAISED FLOOR SYSTEM (INCLUDING RAMPS);

REPLACEMENT MECHANICAL SYSTEM (EQUIPMENT, DUCTWORK, PIPING,

CONTROLS, AND OTHER APPURTENANCES, INCLUDING TEMPORARY CHILLER

PACKAGE);

COMBINATION FIRE ALARM/MASS NOTIFICATION SYSTEM, INCLUDING SMOKE

DETECTION SYSTEM;

INTRUSION DETECTION SYSTEM;

FIRE SUPPRESSION SYSTEM;

VIDEO TELECONFERENCING SYSTEM APPURTENANCES; AND

ELECTRICAL CIRCUIT PLAN AND ELECTRICAL POWER AND LIGHTING PANEL

SCHEDULES.

CERTIFICATES AND OTHER DOCUMENTATION (ALL GA) SHALL BE SUBMITTED FOR

THE FOLLOWING (PROVIDE FOUR (4) COPIES):

CERTIFICATION LETTER FOR 100% FIRE ALARM/MASS NOTIFICATION/FIRE

SUPPRESSION DESIGN (ATTESTED UNDER SIGNATURE OF LICENSED FIRE

PROTECTION ENGINEER);

CERTIFICATION LETTER FOR 100% INTRUSION DETECTION SYSTEM DESIGN

(ATTESTED UNDER SIGNATURE OF LICENSED IDS TECHNICIAN);

FIRE SUPPRESSION SYSTEM DESIGN CALCULATIONS (ATTESTED UNDER SIGNATURE

OF LICENSED FIRE PROTECTION ENGINEER);

TESTING CERTIFICATE FOR SMOKE DETECTION SYSTEM;

FIRE SUPPRESSION SYSTEM CALCULATIONS;

FACP BATTERY CALCULATIONS; AND

HVAC TESTING AND BALANCE REPORTS (CHILLER, BOILERS, PUMPS, COILS, AND

BALANCING COCKS).

ALSO SUBMIT FOR GOVERNMENT APPROVAL DOCUMENTATION FOR THE

DESIGNATED VINDICATOR IDS POINT OF CONTACT, WHICH SHALL INCLUDE

CERTIFICATE(S) OF THE APPROPRIATE TRAINING AND A RESUME DETAILING THE

REQUIRED EXPERIENCE (PROVIDE FOUR (4) COPIES).

FA4608-17-R-0013

15. THE CONTRACTOR SHALL EXECUTE THIS CONTRACT IN ACCORDANCE WITH

THE SPECIFICATIONS BELOW AND ELSEWHERE IN THE STATEMENT OF WORK

(SPECIFICATION SECTIONS 08 71 00 AND 09 90 00 ATTACHED):

A. USE ONLY METAL BOXES FOR ALL ELECTRICAL AND COMMUNICATIONS WORK

(ABSOLUTELY NO PLASTIC BOXES);

B. STUB UP WITHIN PARTITIONS (OR FURRINGS) AT EACH NIPRNET AND SIPRNET

DROP WITH ONE INCH (1”) EMT CONDUIT. CONDUIT SHALL EXTEND SIX INCHES (6”)

ABOVE TOP OF PARTITION. OR, WHERE PARTITIONS EXTEND TO UNDERSIDE OF

EXISTING ROOF DECK, PROVIDE 1” EMT SWEEP THAT PROTRUDES 6” FROM WALL

SURFACE AND EXTENDS 6” ABOVE HEIGHT OF HIGHER CEILING. CAP CONDUIT

ENDS WITH BUSHINGS;

C. STUB UP WITHIN PARTITIONS FOR INFRASTRUCTURE DROPS OF FUTURE SOUND

SYSTEM IN AUDITORIUM 121 WITH ONE-INCH (1”) EMT CONDUIT. CONDUIT SHALL

EXTEND SIX INCHES (6”) ABOVE TOP OF PARTITION. OR, WHERE PARTITIONS

EXTEND TO UNDERSIDE OF EXISTING ROOF DECK, PROVIDE 1” EMT SWEEP THAT

PROTRUDES 6” FROM WALL SURFACE AND EXTENDS 6” ABOVE HEIGHT OF HIGHER

CEILING. CAP CONDUIT ENDS WITH BUSHINGS;

D. THE GOVERNMENT REPRESENTATIVE SHALL MAKE ALL COLOR SELECTIONS

FROM MANUFACTURERS’ STANDARD PALETTES; NO PREMIUM COLORS WILL BE

SELECTED;

E. PAINT SHEEN FOR EXISTING AND NEW HOLLOW FRAMES, NEW HOLLOW METAL

DOORS, AND SOLID CORE WOOD DOORS SHALL BE SEMI-GLOSS. PAINT SHEEN FOR

PREVIOUSLY PAINTED AND NEW GYPSUM BOARD SURFACES SHALL BE SATIN.

PAINT SHEEN FOR PREVIOUSLY PAINTED CMU WALLS SHALL BE SEMI-GLOSS;

F. SOLID CORE WOOD DOORS SHALL BE 1-3/4” THICK, FLUSH, AND ARCHITECTURAL

GRADE; AND SHALL HAVE PARTICLE BOARD CORE, NATURAL BIRCH VENEER,

ROTARY CUT GRAIN PATTERN, AND HARDWARE PREPARATION;

G. FLUORESCENT LIGHT TROFFERS SHALL BE LITHONIA SP8 2’ x 4’ (WITH FOUR (4) T8

STRAIGHT LAMPS PER FIXTURE) OR APPROVED EQUAL;

H. LAY-IN ACOUSTICAL CEILING PANELS (FIBERBOARD) SHALL BE ARMSTRONG

FISSURED WHITE ANGLED TEGULAR 2’ x 2” X 5/8” OR APPROVED EQUAL;

I. ELECTRIC WATER HEATER SHALL BE RHEEM PERFORMANCE PLATINUM 50

GALLON 12-YEAR WARRANTY 5500/5500-WATT ELECTRIC HEATER WITH 68 GALLONS

PER FIRST HOUR DELIVERY (150 DEG F MAXIMUM TEMPERATURE AND 90 DEG F

MINIMUM TEMPERATURE); OR APPROVED EQUAL;

J. CARPET TILES SHALL BE PHILADEPHIA COMMERCIAL MESH WEAVE CARPET TILE;

MANUFACTURED BY SHAW; SKU PCCT-54458-58600, 2’ x 2’ , GLUE DOWN, 1/12 GAUGE, ECOWORX BACKING, GRAPHIC LOOP CONSTRUCTION, 22 OZ PILE FACE WEIGHT, ECO SOLUTION Q NYLON FIBER CONTENT, LIFETIME COMMERCIAL LIMITED

WARRANTY; OR APPROVED EQUAL;

FA4608-17-R-0013

K. VINYL COMPOSITION TILES SHALL BE AZROCK STANDARD VCT, ASTM F 1066

CLASSIFICATION OF CLASS 3 THROUGH PATTERN; 1/8” TOTAL THICKNESS; ASTM F

970 STATIC LOAD LIMIT OF 150 PSI; 12” x 12”; ASTM E 648 FLAMMABILITY OF CLASS 1

>0.45 CRF; ASTM E 662 SMOKE DENSITY OF <450; 5 YEAR LIMITED WARRANTY; OR

APPROVED EQUAL;

L. RECESSED CAN LIGHT FIXTURES SHALL BE EATON HALO COMMERCIAL PD615

LED DOWNLIGHT WITH EATON SLIDE DIMMER SWITCH (MODEL NO. SAL06P/WBSD-

SLD); OR APPROVED EQUAL;

M. FIBERGLASS ACOUSTICAL LAY-IN CEILING PANELS AND ASSOCIATED

SUSPENSION GRID SHALL BE ARMSTRONG OPTIMA 15/16” SQUARE TEGULAR FINE

TEXTURE (ITEM NO. 3250, 2’ x 2’ x 1”) WITH ARMSTRONG PRELUDE SUSPENSION GRID

(BLIZZARD WHITE); OR APPROVED EQUAL;

N. RAISED FLOOR PANELS SHALL BE COMPUTER ENVIRONMENTS INC., TOP

DIMENSONS OF 24” x 24” TAPER TO BOTTOM DIMENSIONS OF 23-3/4” x 23-3/4”; 1-1/8”

OVERALL THICKNESS; PARTICLE BOARD CORE; UNDERSIDE OF GALVANIZED STEEL

PLATING; TOP LAMINATE LAYER WITH PATTERNED FINISH (COLOR/PATTERN FOR

NEW RAISED FLOOR PANELS TO BE SELECTED BY CONTRACTING OFFICER OR HIS

REPRESENTATIVE TO MATCH EXISTING); OR APPROVED EQUAL; AND

O. FIRE-RETARDANT PAINT SHALL BE FLAME STOP II (WATER BASED, NON-TOXIC,

NON-CARCINOGENIC, NO PDBE’S, FLAME SPREAD OF 25, DOES NOT ALTER

STRUCTURAL INTEGRITY OF WOOD, APPLY BY SPRAYING, BRUSHING, OR ROLLING;

MOISTURE CONTENT SHALL BE 5 TO 15% BEFORE APPLICATION, TESTED TO ASTM E

84, NFPA 255, AND UL 723 STANDARDS; ONE COAT REQUIRES 48-HOUR CURING

PERIOD); OR APPROVED EQUAL.

16. WATER FLOW TEST RECORDS (TAKEN SUMMER 2016) FOR THREE FIRE HYDRANTS

NEAR BUILDING 4565 ARE ATTACHED. THIS INFORMATION (THREE PAGES) MAY BE

USED FOR PURPOSE OF FIRE PROTECTION DESIGN. SEE SITE LOCATION MAP,

DRAWING SHEET NO. G01, FOR APPROXIMATE LOCATIONS OF THESE FIRE

HYDRANTS.

17. THE CONTRACTOR SHALL REGULARLY UPDATE (“RED-LINE”) TWO SETS OF

CONSTRUCTION DRAWINGS TO INDICATE AS-BUILT CONDITIONS THAT DIFFER

FROM THOSE SHOWN ON THE ORIGINAL DRAWINGS. THE CONTRACTOR SHALL

MAINTAIN AT LEAST ONE DRAWING SET ON THE JOB-SITE FOR REVIEW AT ANY

TIME BY THE GOVERNMENT REPRESENTATIVE. IN ADDITION TO BOTH SETS OF

THE “RED-LINED” AS-BUILT DRAWING SETS, THE CONTRACTOR SHALL SUBMIT CAD

DRAWING FILES OF THE AS-BUILT DRAWING SET AT CLOSEOUT; THESE FILES SHALL

BE COMPATIBLE WITH AUTOCAD RASTER DESIGN 2014 CADD CONSTRUCTION

DRAWINGS (ORIGINAL DRAWING FILES TO BE PROVIDED BY THE GOVERNMENT

FOR ASSISTANCE IN PREPARING AS-BUILT CADD DRAWING FILES). THE

FA4608-17-R-0013

CONTRACTOR SHALL INCORPORATE INTO THE AS-BUILT CADD FILES THE SHOP

DRAWINGS PROVIDED UNDER THIS CONTRACT.

18. WHEN THE CONTRACTOR DETERMINES THAT SUBSTANTIAL COMPLETION OF

THE WORK HAS BEEN REACHED, THE CONTRACTOR SHALL CONDUCT AN

INTERNAL WALK-THROUGH INSPECTION OF THE PROJECT SITE WITH HIS SUB-

CONTRACTORS AND DEVELOP A PUNCHLIST. AFTER ALL THE ITEMS ON THIS

PUNCHLIST HAVE BEEN RESOLVED, THE CONTRACTOR SHALL SCHEDULE THE

PREFINAL INSPECTION WITH THE GOVERNMENT REPRESENTATIVE. THE

CONTRACTOR AND GOVERNMENT REPRESENTATIVES SHALL THEN INSPECT EVERY

ASPECT OF THE WORK UNDER THIS CONTRACT FOR COMPLETENESS,

FUNCTIONALITY, AND COMPLIANCE WITH THE STATEMENT OF WORK; AND

DEVELOP AN EXHAUSTIVE PUNCHLIST THAT, WHEN ALL ITEMS ARE COMPLETED,

THE GOVERNMENT MAY TAKE BENEFICIAL OCCUPANCY OF THE FACILITY. AFTER

THE CONTRACTOR HAS RESOLVED ALL ITEMS ON THE PREFINAL INSPECTION

PUNCHLIST, HE SHALL SCHEDULE WITH THE GOVERNMENT REPRESENTATIVE THE

FINAL INSPECTION. IF THE GOVERNMENT REPRESENTATIVE DETERMINES DURING

THE COURSE OF THE FINAL INSPECTION THAT WORK ITEMS ON THE PREFINAL

INSPECTION PUNCHLIST HAVE BEEN INCOMPLETELY OR INCORRECTLY RESOLVED,

THE GOVERNMENT REPRESENTATIVE WILL SUSPEND THE FINAL INSPECTION,

INSTRUCT THE CONTRACTOR TO COMPLETE OR CORRECT THE UNRESOLVED

WORK ITEMS, AND RESCHEDULE THE FINAL INSPECTION. THE GOVERNMENT WILL

NOT CLOSE OUT THE PROJECT UNTIL THE FINAL INSPECTION IS CONDUCTED AND

THE CONTRACTING OFFICER CERTIFIES IN WRITING THAT THE INSPECTED WORK

HAS BEEN DONE COMPLETELY, CORRECTLY, AND IN ACCORDANCE WITH THE

STATEMENT OF WORK.

19. THE CONTRACTOR SHALL SCHEDULE WITH THE CONTRACTING OFFICER

TRAINING SESSIONS FOR EACH SYSTEM IN WHICH OPERATIONS AND

MAINTENANCE MANUALS ARE REQUIRED TO BE SUBMITTED (EXCEPTING

PLUMBING FIXTURES); THEY SHALL BE HELD AFTER THE SYSTEM HAS BEEN

SUCCESSFULLY TESTED. TRAINING SESSIONS SHALL BE CONDUCTED AT THE

PROJECT SITE BY QUALIFIED PERSONNEL PROVIDED BY THE SYSTEM

MANUFACTURER (OR BY INSTALLER PERSONNEL, IF MANUFACTURER AGREES IN

WRITING); THE CONTRACTOR SHALL ISSUE THE APPROVED OPERATIONS AND

MAINTENANCE MANUALS TO THE ATTENDEES FOR ‘FOLLOW-ALONG’ MATERIAL.

TYPICAL DURATION OF EACH TRAINING SESSION SHALL BE TWO (2) HOURS.

20. THE CONTRACTOR SHALL SUBMIT A COMPLETED FORM 1354 WHICH FULLY

DESCRIBES, IN ACCORDANCE WITH THE REQUIREMENTS OF THE DOCUMENT, ALL

FIXTURES, EQUIPMENT ITEMS, AND SYSTEM COMPONENTS PROVIDED UNDER THIS

FA4608-17-R-0013

CONTRACT. IF THE INTIAL SUBMITTAL IS INCOMPLETE AND/OR CONTAINS

INACCURATE INFORMATION, THE CONTRACTOR SHALL REACCOMPLISH THE WORK

(RESUBMIT CORRECTED FORM THAT IS SATISFACTORY TO THE INSTALLATION REAL

PROPERTY OFFICER). REACCOMPLISHMENT OF THE DOCUMENT SHALL RECUR

UNTIL THE INSTALLATION REAL PROPERTY OFFICER, IN COORDINATION WITH

THE CONTRACTING OFFICER, IS SATISFIED THAT THE FORM 1354 SUBMITTAL IS

COMPLETE AND ACCURATE.

21. THE CONTRACT PERFORMANCE PERIOD SHALL BE 180 CALENDAR DAYS.

** END OF STATEMENT OF WORK **

SUPPLEMENT TO

FINAL STATEMENT OF WORK

(ROOF REPLACEMENT)

RENOVATE BUILDING 4565 FOR A6 AND A9

PROJECT NO. AWUB 16-0040

28 APRIL 2017

1. THE FOLLOWING IS A SUPPLEMENT TO THE FINAL STATEMENT OF WORK (DATED

14 APRIL 2017); IT DOES NOT DELETE OR ALTER ANY PROVISION IN THE FINAL

STATEMENT OF WORK UNLESS OTHERWISE INDICATED BELOW.

2. THE ROOF REPLACEMENT WORK SHALL BE PERFORMED IN ACCORDANCE WITH

THE INSTRUCTIONS HEREIN, OTHER CRITERIA AND INSTRUCTIONS CONTAINED IN

THE CONTRACT, THE PREVIOUSLY RELEASED DRAWING SHEETS AND

SPECIFICATIONS, AND THE FOLLOWING DRAWING SHEETS (ATTACHED):

ARCHITECTURAL:

A10 DEMOLITION ROOF PLAN

A11 ROOF PLAN – NEW CONSTRUCTION

A12 ROOF DETAILS

3. IN CASE OF DISCREPANCY BETWEEN ROOF REPLACEMENT DRAWING SHEETS

(A10, A11, AND A12) AND PREVIOUSLY RELEASED DRAWING SHEETS M01 AND MO2,

INSTRUCTIONS PROVIDED ON ROOF REPLACEMENT DRAWING SHEETS (A10, A11,

AND A12) SHALL GOVERN.

4. ALL WOOD FOR ROOF REPLACEMENT WORK SHALL BE PRESSURE TREATED,

GRADE 2, SOUTHERN PINE OR SOUTHERN YELLOW PINE.

5. PAINT THESE SURFACES WITH THE FOLLOWING COATING SYSTEMS:

EXISTING STEEL (PREVIOUSLY COATED WITH ALKYD OR LATEX):

MPI REX 5.1C-G5 (SEMI-GLOSS):

SPOT PRIMER: MPI 79

INTERMEDIATE COAT: MPI 163

TOPCOAT: MPI 163

SYSTEM DFT: 5 MILS

EXTERIOR SURFACES, OTHER METALS (NON-FERROUS):

ALUMINUM, ALUMINUM ALLOY, AND OTHER MISCELLANEOUS NON-FERROUS

METAL ITEMS:

MPI EXT 5.4F-G5 (SEMI-GLOSS):

PRIMER: MPI 95

INTERMEDIATE COAT: MPI 8

TOPCOAT: MPI 8

SYSTEM DFT: 5 MILS

FA4608-17-R-0013

EXTERIOR WOOD, DRESSED LUMBER:

NEW AND EXISTING, UNCOATED DRESSED LUMBER:

ALKYD: MPI EXT 6.3b-G5 (SEMI-GLOSS):

PRIMER: MPI 7

INTERMEDIATE COAT: MPI 94

TOPCOAT: MPI 94

SYSTEM DFT: 5 MILS

6. THE CONTRACTOR SHALL EXECUTE THIS CONTRACT IN ACCORDANCE WITH

SPECIFICATION SECTION 075216 (ATTACHED). PROVIDE THE SUBMITTALS AS

REQUIRED IN SPECIFICATION SECTION 075216 TO THE CONTRACTING OFFICER.

** END OF SUPPLEMENT TO FINAL STATEMENT OF WORK **