FA4608-15-Q-S098, Questions and Answers #2 31 August 2015
1. What type of lock will be required on the door and how many doors need the locks? I believe you want Door Strikes at Barksdale, but I am just confirming.
Answer: Door strike (electronic 12 volt d.c.), 1 door
2. Regarding the wireless duress buttons what is the frequency range allowed for these devices? The Barksdale AFB frequency manager can give you this if the SF unit frequency monitor doesn't know.
Answer: 902-928 MHZ is current duress frequency
3. I see there are two BMS's in the room, is one BMS an emergency exit or will it also be used to gain entry into the room normally?
Answer: One is an emergency exit.