Attachment 6 - QA.docx

DOCX document 18 KB Posted

Attached to
SFS Firing Range Cleanup, Minot AFB Federal contract opportunity
Solicitation number
FA452822QCB01
Issued by
Department of the Air Force Global Strike Command

About this file

This document contains questions and answers regarding a federal contract opportunity for firing range cleanup services at Minot Air Force Base. The opportunity involves monthly cleaning of three firing ranges totaling 246 feet by 136 feet in size, with 240 bucket catchers. Services will also include replacement of HEPA filters as needed in the ventilation system. The contractor will be required to remove all hazardous waste in accordance with applicable regulations and conduct testing through the base's Bio Environmental and HAZWASTE departments. Details provided include the dimensions and layout of the ranges, photographs of the facilities, and information on range construction and the ventilation system.

View the file

Other files for this federal contract opportunity

Other files attached to SFS Firing Range Cleanup, Minot AFB, newest first.
File Type Posted
Attachment 1 - PWS (Amended 06 Dec 21).docx DOCX document
Combined Synopsis Solicitation_S.pdf PDF
Attachment 3 - Quote Sheet.xlsx XLSX spreadsheet
Site Visit QA.docx DOCX document
Attachment 1 - PWS (Amended 29 Nov 21).pdf PDF
Attachment 6 - QA.pdf PDF
Attachment 5 - Site Visit Instructions.pdf PDF
Combined Synopsis Solicitation_S.pdf PDF
Attachment 4 - Site Pictures.docx DOCX document
Combined Synopsis Solicitation_S.pdf PDF
Attachment 2 - Wage Determination.pdf PDF
Attachment 1 - PWS.pdf PDF
Attachment 3 - Quote Sheet.xls XLS spreadsheet
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q&A

FA452822QCB01

Firing Range Clean up

· Do you have a general idea on how many barrels were generated in the past, per year or quarter for this type of service?

Answer: On our current range about 14 barrels would be generated per quarter on the small arms range. The new range is double the student capacity therefore will require monthly cleaning to keep up with usage and debris build up.

· Could you provide the dimensions of the indoor range?

Answer: 246’ x 136’ total space includes 3 individual ranges

· Are there any pictures available of the site, catch basin and the entire range?

Answer: Yes – attached.

· Is there an access point for a truck/trailer to park close?

Answer: Yes – there is a service road that runs along the side of the range with multiple entrances to the bullet trap area.

· Would you be confident that all rounds are spent?

Answer: Yes – no brass will be present during cleanup

· Is there a specific license that would be required for this or will our regular haz-mat certification suffice?

Answer: Contact the North Dakota State Division of Waste Management to inquire about special permits/licensing. 701-328-5166

· What is the number of firing range bays requiring cleaning?

Answer: 3

· What are the dimensions of the firing ranges?

Answer: 246’ x 136’ total space includes 3 individual ranges

· Specific areas that requiring cleaning?

Answer: All three ranges and bullet trap area located behind range, replacement of filters in collection system located in back of range.

· What is the number of bucket catchers?

Answer: 240 buckets

· Is there any outside firing range tunnels or tube to be cleaned?

Answer: No

· Can you please post details of range builder, how many firing lanes, bullet trap type, pictures of entire range and trap, and any other rooms associated with the range that will require remediation due to tracking. Also, the PWS makes no mention of testing requirements is this expected to be built in the quote?

Answer: Range builder is Bryant Construction LLC, 40 firing lanes total, pictures are attached, no other parts of the building should require cleaning. What type of testing is being asked? All hazardous waste testing is done on base through Bio Environmental and HAZWASTE through 5th Civil Engineering Squadron.

· Please provide details of range ventilation (HVAC System), filter types, how many pre filters, how many Hepa filters size etc.

Answer: Photos attached with parts numbers.

· Please provide the scope of work or plans for the project?

Answer: The scope of work shall be complete cleaning of range and bullet trap area monthly. HEPA Filters should be replaced as needed during monthly cleaning. Ideally this will be the last weekend of the month to avoid interruptions in training. Please specify anything not listed in the PWS.