Questions
| Contractor Questions |
| FA4528-20-Q-JS04 |
| Seq. # | Document and Section | Page | Item | Customer Response |
| 1 | SOW Section 1. | 1 of 5 | Can the government provide a copy of the Air Force Approved Product List (APL) and a copy of the IDS Equipment List? If a copy cannot be provided can a link be provided? | Contact Minot AFB - 5 CS IA Office |
| 2 | SOW Section 3.3.3.1 | 2 of 5 | What are the makes and models of the existing 9 cameras? | Axiz PTZ Cameras, Model Q6045-E |
| 3 | SOW Section 8.3 | 4 of 5 | For new camera locations, is there network infrastructure in place or will the contractor be required to provide network switches? | Network infrasturcture is in place |
| 4 | SOW Section 8.3 | 4 of 5 | If contractor is required to provide switches for new camera locations, how will these switches be connected to the Airforce Network? If its fiber optic cable is there dark fiber at new camera locations and is the fiber optic cable multi-mode or single mode fiber? | Need comm to answer |
| 5 | SOW Section 3.5 | 2 of 5 | Is UPS/Battery back up required? If so, how many hours of back up power is required? | No |
| 6 | SOW Section 3.2 | 1 of 5 | Will monitors be required with the 2 new workstations? If so, what size of monitors are required? | 1 monitor a minimum of 46" is required. Second location viewing must be able to display cameras/video feed via connection to monitor of their choosing |
| 7 | SOW Section 11.0 | 5 of 5 | Appendix A shows the location of all cameras to be installed. Can the government identify which cameras are currently installed and which cameras are new locations? | Location where Axiz PTZ cameras are current not installed. North Gate #14 & 15, Minot South Gate #12 & 13, Magic City Gate #10 & 11. Location 1-9 have an Axiz PTZ camera currently mounted. |
| 8 | ||||
| 9 | SoW Section 1.0 | Can the government provideCan the government provide what systems currently have an ATO or provide the APL? | Contact Minot AFB - 5 CS IA Office | |
| 10 | SoW Section 3.1 | Can the government confirm that there is adequate rack space available for the new equipment being installed at this site? | Unknown, current system required no rack space was a CPU connected via LAN. | |
| 11 | SoW 3.3.2. | Can the government confirm that the operating temperature ranges of: 0 degrees F to 90 degrees F are acceptable for the equipment being provided? (data source: www.GF.ND.Gov Game and Fish Gov't site) | The tempeture range should suitable to the Axiz PTZ Cameras, Model Q6045-E tempeture range | |
| 12 | SoW Section 8.3 | Can the government confirm that network switches are required where cameras currently don't exist? | Network switches are available at all identified camera locations | |
| 13 | SoW Section 8.3 | Is this cable required for the existing and non-existing camera points? | Cable is required for non-existing camera points, Appendix A camera locations 10-15. Appendix A camera locations 1-9 have cameras in place, however only cameras 4, 5, 6, 9 are still fully operational. Wires/connection LAN cable would need to be checked. | |
| 14 | SoW Section 8.3 | If new cabling is required for the new camera points, is there preexisting cable raceways from the switch point to the camera mounting point? | No, current LAN cables are run above the ceiling, no raceways are in place. | |
| 15 | SoW Section 11.0 | Since the system will be on the Air Force network, will ports for the cameras be provided or should switches be included in the quote? The picture in the SoW Section 11.0 shows some camera sites that are further away than a 100 meter Cat6. | Ports would be provided. | |
| 16 | ||||
| 17 | ||||
| 18 | ||||
| 19 | ||||
| 20 | ||||
| 21 | ||||
| 22 | ||||
| 23 | ||||
| 24 | ||||
| 25 | ||||
| 26 | ||||
| 27 | ||||
| 28 | ||||
| 29 | ||||
| 30 | ||||
| 31 | ||||
| 32 | ||||
| 33 | ||||
| 34 | ||||
| 35 | ||||
| 36 | ||||
| 37 | ||||
| 38 | ||||
| 39 | ||||
| 40 | ||||
| 41 | ||||
| 42 | ||||
| 43 | ||||
| 44 | ||||
| 45 | ||||
| 46 | ||||
| 47 | ||||
| 48 | ||||
| 49 | ||||
| 50 | ||||
| 51 | ||||
| 52 | ||||
| 53 |
&9Page &P / &N
File details come from the government source that posted it. Updated .