Atch 12 - Existing Elevator Drawings.pdf
PDF 875 KB Posted
- Attached to
- Repair Building 502 HVAC, Elevator, and Roof
- Solicitation number
- FA449720R0032
About this file
This document contains existing elevator drawings and specifications for Building 502 at Dover Air Force Base, as well as the related federal contract opportunity solicitation. The opportunity solicitation seeks a contractor to replace the roof snow retention system, one seven-story elevator, and repair tower HVAC components at Building 502 for the Department of the Air Force Air Mobility Command. The statement of work provides detailed requirements for the project scope, which includes all design, labor, materials, tools and equipment. The contractor must complete the work in accordance with the solicitation and attached documents.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELEVATOR NUMBER 1
ELEVATOR APPLICATION MACHINE ROOMLESS
CLASS OF LOADING PASSENGER
SEISMIC ZONE N/A
CAPACITY 2500 LB [1160 kg] SPEED, CONTRACT 350 FPM [1.75 m/s] CAB LIGHT 120 15 15 1 1
ROPING 2 : 1
LANDINGS / OPENINGS 4/4F CONTR SUPPLY 480 30 30 3 1 0
WEIGHT 2850LB[1292kg]
RAIL GUIDE TYPE SHOE
SAFETY TYPE DYNATECHPQ-3400-UD
WEIGHT ) 4100 LB [1859 kg]
OVER BALANCE 50%
STEEL BLOCKS QTY (1" TH'K) 100
RAIL GUIDE TYPE SHOE
CONSTRUCTION STEEL FRAME
CAR GUIDE RAIL SIZE 15 LB/FT[22.5 kg/m] CWT GUIDE RAIL SIZE 8 LB/FT[12 kg/m] GOVERNOR CABLE DIAMETER 1/4" [6.4 mm] GOVERNOR CABLE LENGTH 212 FT [65 m]
HOIST CABLE QUANTITY 6
HOIST CABLE DIAMETER 8 MM Drako 250T Steel Core HOIST CABLE LENGTH 235 FT [72 m] HOIST CABLE BREAKING STRENGTH 8723LB [38.8 kN] MAXIMUM RAIL BRACKET SPACING 12 FT [3658 mm]
CAR BUFFER TYPE OIL
CAR BUFFER LOAD RATING 2x6002AF2(1323-10000LB)[600-4535kg]
CWT BUFFER TYPE OIL
CWT BUFFER LOAD RATING 6002AF2(1323-10000LB)[600-4535kg] IND DRWN CHKD COMP. CHAIN//CABLE QTY x SIZE 1 x WF15 A OZ
MACHINE TYPE MAGIL MAG05-2535
MACHINE GEAR RATIO 1 : 1
DRIVE SHEAVE DIAMETER 15.75"[400 mm] IDLER SHEAVE DIAMETER 13" [330 mm] B MS
MOTOR SIZE 16.6 HP [12.4 kW]
DRIVE V.V.V.F
HEAT DISSIPATION IN MACHINERY SPACE 1x(2115Btu/h[0.61kW]) HEAT DISSIPATION IN CONTROL SPACE/ROOM 1x(11291Btu/h[3.31kW]) TWO HOIST HOOKS, EACH, STATIC 1.825KIPS [8kN]
R1 0.17KIPS [0.76 kN] R2 0.07 KIPS [0.31 kN] R1 N/A R2 N/A R1 0 KIPS [ 0 kN] R2 0.306 KIPS [1.36 kN]
R3U N/A R3D 10.1 KIPS [44.7 kN] R1 N/A R2 N/A
CAR BUFFER, EACH, DYNAMIC R4 11.66 KIPS [51.76kN] CWT BUFFER, EACH, DYNAMIC R5 17.87 KIPS [79.33kN] GOVERNOR, STATIC R6 0.4 KIPS [1.78 kN] GOVERNOR, DYNAMIC R6 1.5 KIPS [6.69 kN]
R7 10.38 KIPS [46.2 kN] R8 6.07 KIPS [27.0 kN] R9 3.22 KIPS [14.3 kN] R10 4.52 KIPS [20.1 kN]
CROSS HEAD SECTION 6"H x 2"W x 12GA UPRIGHT SECTION 8"Wx2.125"Hx1.1"WINGSx12GA SINGLE PLANK SECTION 7"H x 2.75"W x 10GA BOTTOM SHEAVE SUPPORT SECTION 7"Wx7"Hx2.5"WINGSx10GA JOB No. DWG. No.
DRAWN BY:C.CH
CHECKED BY:
DATE: 02/13/08
File: J082864L1B PAGE: 1 OF 4
PROVIDE VENTILATION IN 1) MACHINERY SPACE IN OVERHEAD; 2)
CONTROL SPACE OR ROOM IF PROVIDED, TO MAINTAIN TEMPERATURE
OF 41°F [5°C] TO 90°F [32°C]. FOR HEAT DISSIPATION AT 60% DUTY
CYCLE SEE GENERAL INFORMATION TABLE. HUMIDITY RANGE IS 0% TO
95% NON-CONDENSING.
DOVER AIR FORCE BASE
POCKETS FOR BEAMS AS SHOWN WHERE REQUIRED.
INFILL CAVITY AFTER BEAMS ARE SET IN PLACE.
ADDRESS:
DOVER, DELAWARE
DOVER AFB
ILLUMINATION AT SILL OF EVERY LANDING IS 100 LUX.
PROJECT:
AT OVERHEAD, PROVIDE 120V LIGHT FIXTURE, SWITCH AND
CONVENIENCE OUTLET. ILLUMINATION 200 LUX. MIN.
GENERAL INFORMATION
PREPARED FOR:
DELAWARE ELEVATOR INC.WIRE MESH PARTITION AS SHOWN WHERE REQUIRED.
PARTITION TO BE ABLE TO REJECT 2" [50 MM] DIA BALL AT
PIT LEVEL AND 1" [25 MM] AT HIGHER LEVELS. MINIMUM
PARTITION HEIGHT IS 6'-7" [2000 MM] OR OPENING HEIGHT
WHICHEVER IS LESS.
VOLTAGE & AMPERAGE DATA PROVISIONS BY OTHERS
PIT TO BE CONSTRUCTED PER ASME A17.1-2004 SECTION
2.2.2. PROVIDE DRAIN OR SUMP PUMP FOR ELEVATORS
WITH FIRE FIGHTER'S EMERGENCY OPERATION.
HOISTWAY AND CONTROL SPACE OR ROOM IN ACCORDANCE WITH
ELEVATOR SAFETY CODE REGULATIONS. HOISTWAY TO BE ERECTED
PLUMB 1/2" [±13 MM] THRUOUT.
NO CONDUIT WIRING OR PIPING OTHER THAN THAT
PERTAINING TO THIS ELEVATOR IS PERMITTED IN THE HOISTWAY AND
CONTROL SPACE OR ROOM.
DATE
24-Apr-08
REVISIONS
POCKETS FOR BEAMS AS SHOWN WHERE REQUIRED.
DO NOT INFILL CAVITY AFTER BEAMS ARE SET IN PLACE.
IN PIT PROVIDE 120 VOLT GUARDED LIGHT FIXTURES, SWITCH AND
CONVENIENCE OUTLET. SWITCH TO BE ON JAMB SIDE OF BOTTOM
LANDING DOOR.ILLUMINATION 100 LUX. MIN.
FOR JOBS ENGINEERED PER ASME A17.1 PROVIDE MEANS
OF ACCESS TO GOVERNOR(S) FOR INSPECTION AND
SERVICING (SECTION 2.1.3.1.2).
1-Aug-08
HOISTWAY SIZE WAS 8'-7"X 5'-9", CONTROLLER WAS
AT FRONT FLUSH MOUNTING, TRAVEL WAS 104'-9",
LANDING WAS 9, FLOOR HEIGHT REVISED, SHOW PIT
LADDER DETAIL WITH AND WITHOUT POCKET.
LANDINGS/OPENINGS WERE 7, FLOOR TO FLOOR HEIGHT
REVISED, TRANSFORMER DEL., RESISTOR AND POWER
UNIT RELOCATED IN CONTROLLER ROOM., HEAT
DISSIPATION REVISED
M A
X . R
A
IL
L O
AD
S
HOISTWAY ACCESS:
A) FOR SPEED 150 FPM [0.75 M/S] OR LESS PROVIDE H.I.S.
AT TOP LANDING WHEN DISTANCE FROM TOP OF CAR TO
TOP LANDING EXCEEDS 2'-11" [900 MM] WHEN CAR IS LEVEL
WITH LANDING BELOW TOP LANDING.
B) FOR SPEEDS MORE THAN 150 FPM [0.75 M/S] PROVIDE
H.I.S. AT TOP AND BOTTOM LANDINGS.
LOADING/
UNLOADING
SEISMIC
ACCESS TO CONTROL SPACE OR ROOM TO BE SAFE AND
CONVENIENT. IF A ROOM OR CLOSET IS PROVIDED, PROVIDE A DOOR
3'-0" [915 MM] WIDE x 6'-8" [2030 MM] HIGH MINIMUM. DOOR MUST BE
SELF CLOSING AND SELF LOCKING. GIVE KEYS TO AUTHORIZED
PERSONNEL ONLY. CLEAR HEAD ROOM NOT LESS THAN 7'-0"[2134 MM].
OPENINGS FOR ENTRANCES IN FRONT WALLS TO BE FILLED IN AFTER
ENTRANCE FRAMES HAVE BEEN INSTALLED. GROUT IN SILLS FULL
LENGTH.
NOTE: ENTRANCE FRAMES ARE NOT DESIGNED TO SUPPORT
OVERHEAD WALL LOADS. SUITABLE SUPPORTS FOR THESE LOADS
MUST BE PROVIDED BY OTHERS.
C A
R M
A C
H
IN
E C
W T
H O
IS
TW
AY
E
Q U
IP
M
EN
T
J082864L
CONTROL SYSTEM
C A
R S
LI
N
G
SAFETY APPL.
SEISMIC
C A
R C
W T
B U
IL
D
IN
G
R E
A C
TI
O
N S
MACHINE/ MACHINE BEAM, DYNAMIC
G E
N E
R A
L
1) ALWAYS PROVIDE AUXILIARY DISCONNECT SWITCH IN
OVERHEAD MACHINERY SPACE. SEE SCHEMATIC.
2) WHEN CONTROLLER IS IN PLACE ACCESSIBLE TO PUBLIC
PROVIDE LOCKABLE CIRCUIT BREAKERS IN CONTROL
CABINET.
Version: 0
ThyssenKrupp Elevator
J082864
SCALE: N.T.S.
B
HOIST HOOKS CAPABLE TO HANDLE MAXIMUM LOAD SHOWN ON
GENERAL INFORMATION TABLE.
FOR GROUPS OF ELEVATORS IN SAME HOISTWAY PROVIDE DIVIDER
BEAMS (I-BEAMS 4"[100 MM] WIDE MAX. WHERE SHOWN AT VERTICAL
INTERVALS NO GREATER THAN MAX. RAIL BRK'T SPACING PER
GENERAL INFORMATION TABLE. UPPER MOST BEAM AT DISTANCE
EQUALS CAB HEIGHT PLUS 3'-10"[1170 MM] ABOVE TOP LANDING.
ELEVATOR PIT LADDER TO COMPLY WITH
CAN/CSA B-44-04 OR ASME A17.1S-2004 (IF APPLY).
CWT RAIL, SMALLEST SIZE:
- 8 LB/FT [12 KG/M] FOR SEISMIC ZONE 1.
- 15 LB/FT [22.5 KG/M] FOR SEISMIC ZONES 2 OR GREATER.
REV.
DESIGNED PER ASME A17.1-2004 AND A17.1S-2005
PROPRIETARY RIGHTS OF THYSSENKRUPP NORTHERN ELEVATOR ARE INVOLVED IN THE
SUBJECT MATTER OF THIS MATERIAL AND ALL MANUFACTURING, REPRODUCTION, USE AND SALES RIGHTS PERTAINING TO SUCH SUBJECT MATTER ARE EXPRESSLY RESERVED. IT IS SUBMITTED IN CONFIDENCE FOR A SPECIFIED PURPOSE, AND THE RECIPIENT, BY ACCEPTING THIS MATERIAL, AGREES THAT THIS MATERIAL WILL NOT BE USED, COPIED OR REPRODUCED IN WHOLE OR IN PART, OR ITS CONTENTS REVEALED IN ANY MANNER, OR TO ANY PERSON, EXCEPT FOR THE PURPOSE
DELIVERED.
SUPPORT BEAMS WHERE REQUIRED AND AS SHOWN. MAXIMUM
DEFLECTION IS 1/1666 OF BEAM FREE SPAN.
ADEQUATE SUPPORTS FOR RAIL BRACKETS AT VERTICAL INTERVALS
NO GREATER THAN MAX. RAIL BRACKET SPACING SHOWN ON GENERAL
INFORMATION TABLE. HIGHEST SUPPORT AT DISTANCE EQUAL CAB
HEIGHT PLUS 3'-8"[1120 MM] ABOVE TOP LANDING. SUPPORTS TO BE
EITHER BUILDING BEAMS, INSERTS, OR BANDS MADE OF 3000 PSI [20
MPa] CONCRETE 8" [200 MM] X 6" [150 MM] MIN.
PIT LADDER, LOWEST LANDING HALL DOOR IS ALSO
PROVIDED WITH HAND GRIPS TO 48" [12220 MM] ABOVE
LANDING LEVEL.
TI
M
E D
E
LA
Y 'D
' F U
S E
(A M
P
P H
A S
E
PROVISIONS BY OTHERS
PROVIDE ONE COMPENSATION CHAIN IF REQUIRED.
MINIMUM PIT DEPTH IS 5 FT.
NOTES
PIT STOP SWITCH IS 1'-6' [450 MM] ABOVE BOTTOM
LANDING.
IF PIT DEPTH EXCEEDS 5'-7" [1700 MM], PROVIDE ONE MORE
SWITCH 3'-11" [1200 MM] ABOVE PIT FLOOR.
WHERE POWER IS AVAILABLE FROM MULTIPLE SOURCES, PROVIDE
POWER TRANSFER SWITCH(ES) WITH TIME DELAY OF APPROX. 10
SECONDS BETWEEN THE REMOVAL AND REAPPLICATION OF POWER
TO LOAD FROM ANY SOURCE.
CAR RAIL, SMALLEST SIZE:
- 15 LB/FT [22.5 KG/M] FOR SEISMIC ZONE 1
- FOR SEISMIC ZONES 2 OR GREATER T.B.A. BY
ENGINEERING
TOE GUARD:
2'-0" [610 MM] FOR PIT DEPTH LESS THAN 5'-0"[1524 mm], 4'-0" [1220 MM] FOR PIT DEPTH 5'-0"[1524 mm] AND MORE
A) WHEN CONTROLLER IS IN PLACE ACCESSIBLE TO PUBLIC PROVIDE
SEPARATE OPTIONAL SWITCHES IN BUILDING ELECTRICAL ROOM;
ELECTRICAL POWER SUPPLY TO TERMINATE AT THE CONTROLLER
CABINET; REFER TO CONTRACT FOR CABINET LOCATION.
B )WHEN CONTROLLER IS IN CONTROL ROOM OR CLOSET NOT
ACCESSIBLE TO PUBLIC PROVIDE LOCKABLE FUSED DISCONNECTS
SWITCHES OR CIRCUIT BREAKERS IN CONTROL ROOM OR CLOSET.
SEE VOLTAGE & AMPERAGE DATA IN TABLE ABOVE.
EQUIPMENT
LI
N
E V
O
LT
A G
E
D
IS
C O
N N
E C
T S
IZ
E
(A M
P
MIN. CLEARANCE REQ'D IN FRONT OF ELECTRICAL PANELS:
- 3'-3 1/2" [1000 MM] IN CANADA;
- 3'-6" [1070 MM] EXCEPT 4'-0" [1220 MM] WHEN FACING
EACH OTHER IN U.S.A.
IN THE CONTROL SPACE OR ROOM, PROVIDE 120 VOLT LIGHT
FIXTURES, SWITCH AND CONVENIENCE OUTLET. SWITCH TO BE INSIDE,
ON LOCK SIDE OF DOOR. ILLUMINATION 200 LUX. MIN.
Q
TY
R E
Q 'D
FU
S
E D
Q
TY
R E
Q 'D
U N
FU
S
E D
T I M E
A
FINAL
| J082864L1B |
| J082864L2B |
| J082864L3B |
| J082864L4B |
| 07-21-2008 |
File details come from the government source that posted it. Updated .