Attachment 5 Asbestos and Lead Based Paint Reports Amend 003.pdf
PDF 736 KB Posted
- Attached to
- Remove Filing System Amendment 004 Federal contract opportunity
- Solicitation number
- FA301623U0243
About this file
This document contains an asbestos and lead-based paint analysis report and details of a related federal contract opportunity for removal work. The analysis report tests samples from Room 160 at Joint Base San Antonio Randolph in Texas for asbestos and other materials. It identifies three samples containing 3% chrysotile asbestos and finds no asbestos in the other samples.
The related federal contract opportunity is solicitation number FA301623U0243 from the Air Force Air Education and Training Command to remove the filing system in the room. It provides key information for contractors to bid on the asbestos and lead removal work identified in the analysis report.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment Acknowledgement Sheet.pdf | ||
| Attachment 3 Statement of Work Amend 004.pdf | ||
| Combined Synopsis Solicitation Amend 003.pdf | ||
| Attachment 4 WD 2015-5253 Rev 21 7-12-2023 Amend 003.pdf | ||
| Remove Filing System Qustions and Answers Amend 003.pdf | ||
| Combined Synopsis Solicitation Amend 002.pdf | ||
| Attachment 1 Clauses and Provisions.pdf | ||
| Attachment 3 Statement of Work.pdf | ||
| Combined Synopsis Solicitation.pdf | ||
| Attachment 2 Schedule of Supplies or Services.pdf | ||
| Attachment 4 WD 2015-5253 Rev 20 12-27-2022.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bulk Asbestos Analysis By Polarized Light Microscopy
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
RND13_11050113_Remove File System_Room 160Project:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 802 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 71987896_PLM
Date Reported: 3/21/2022
Date Received: 3/18/2022
Lab Order ID: 71987896
3% Chrysotile
13-FLVCT-
001-B-001 - A
Tan floor tile; with mastics mastic 1
Black Non Fibrous Homogeneous
Crushed71987896PLM_1
Other 97%
3% Chrysotile
13-FLVCT-
001-B-001 - B
Tan floor tile; with mastics tile
Tan Non Fibrous Homogeneous
Dissolved71987896PLM_13
Other 97%
None Detected
13-FLVCT-
001-B-001 - C
Tan floor tile; with mastics mastic 2
Yellow, Tan Non Fibrous Homogeneous
Dissolved71987896PLM_14
Other 100%
Not Analyzed
13-FLVCT-
001-B-002 - A
Tan floor tile; with mastics mastic 1
71987896PLM_2
Not Analyzed
13-FLVCT-
001-B-002 - B
Tan floor tile; with mastics tile
71987896PLM_15
None Detected
13-FLVCT-
001-B-002 - C
Tan floor tile; with mastics mastic 2
Yellow, Tan Non Fibrous Homogeneous
Dissolved71987896PLM_16
Other 100%
Not Analyzed
13-FLVCT-
001-B-003 - A
Tan floor tile; with mastics mastic 1
71987896PLM_3
Not Analyzed
13-FLVCT-
001-B-003 - B
Tan floor tile; with mastics tile
71987896PLM_17
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Lachlan Krenz (18)
P-F-002 r15 1/16/2023
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
RND13_11050113_Remove File System_Room 160Project:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 802 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 71987896_PLM
Date Reported: 3/21/2022
Date Received: 3/18/2022
Lab Order ID: 71987896
None Detected
13-FLVCT-
001-B-003 - C
Tan floor tile; with mastics mastic 2
Yellow, Tan Non Fibrous Homogeneous
Dissolved71987896PLM_18
Other 100%
3% Chrysotile
13-WLSH-
001-B-004
Off White; Chalky;
Gran;Brown paper
White Non Fibrous Homogeneous
Crushed71987896PLM_4
Other 97%
Not Analyzed
13-WLSH-
001-B-005
Off White; Chalky;
Gran;Brown paper
71987896PLM_5
Not Analyzed
13-WLSH-
001-B-006
Off White; Chalky;
Gran;Brown paper
71987896PLM_6
None Detected
13-WLJ-001
-B-007
Off White; Chalky; Gran sample different from B-008
Brown, Tan, White Non Fibrous Heterogeneous
Crushed71987896PLM_7
Other 100%
3% Chrysotile
13-WLJ-001
-B-008
Off White; Chalky; Gran White, Grayish Non Fibrous Homogeneous
Crushed71987896PLM_8
Other 97%
Not Analyzed
13-WLJ-001
-B-009
Off White; Chalky; Gran
71987896PLM_9
None Detected
13-WLPL-
001-B-0010
Off White;;Gray;Tan;Cementitious single layer plaster
Gray Non Fibrous Heterogeneous
Crushed71987896PLM_10
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E, App.E
RND13_11050113_Remove File System_Room 160Project:
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos Fibrous
Components Non-Fibrous Components
Attributes
Treatment
Edward VogelAttn:Customer: 802 CES/CEIE 1651 5th Street West IBSA Randolph, TX 78150
Analysis ID: 71987896_PLM
Date Reported: 3/21/2022
Date Received: 3/18/2022
Lab Order ID: 71987896
None Detected
13-WLPL-
001-B-0011
Off White;;Gray;Tan;Cementitious
Gray Non Fibrous Heterogeneous
Crushed71987896PLM_11
Other 100%
None Detected
13-WLPL-
001-B-0012
Off White;;Gray;Tan;Cementitious
Gray Non Fibrous Heterogeneous
Crushed71987896PLM_12
Other 100%
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Approved SignatoryAnalyst
Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
Scientific Analytical Institute 4604 Dundas Dr. Greensboro, NC 27407
Phone: 336.292.3888 Fax: 336.292.3313 www.sailab.com /ab@sailab.com
Company Contact Informatfon
Company: 802 CES/CEIE Contact: Edward Vogel
Address: 1651 5th Street West Phone Ii]: 210-652-3605
JBSA Randolph, TX 78150 Fax0:
Email Ii]: edward.vogel@us.af.mil
Billing/Jnvoic~ ·1µ(oi-matio1f ··. .· .. Turn Around Times Company: SAME AS ABOVE 90Min. • 48 Hours • Contact: 3 Hours • 72 Hours • Address: 6 Hours • 96 Hours •
12 Hours • 120 Hours • 24 Hours Iii 144+Hours 0
PO Number:
Project Name/Number: RND13_11050113_Remove File System_Room 160
Lab Use Only (A ()"'7{l af .
Lab Order m:/l l · { V iv-{ lj)
Client Code: ______ _
Asbestos Test Types
PLM EPA 600/R-93/116 (PLM) 0
Positive stop 0 PLM Point Count 400 (PT4) • PL(vt Point Count 1000 (PTM) • PCM NIOSH 7400-A Rules (PCM) • B Rules (PCB) 0 TWA(PTA) •
TEM AHERA (AHE) •
TEM Level II (LU) •
TEM NIOSH 7402 (TN!) . •
TEM Bulk Qualitative (TBL) • TEM Bulk Chatfield (TBS) • TEM Bulk Quantitative (TBQ) • TEM Wipe ASTM D6480-05 • TEM Microvac ASTM D5755-02 • TEM Water EPA 100.2 (TWI) • Other: •
_SampleID # Description/Locatie>n Volume/ Area Comments ..
13-FLVCT-001-B-001 Tan floor tile; with mastics Positive Stop
" 13-FLVCT-001-B-002 Tan floor tile;with mastics
" 13-FLVCT-001-B-003 Tan floor tile;with mastics
13-WLSH-00 1-B-004 Off White; Chalky; Gran;Brown paper Positive Stop
" 13-WLSH-001-B-005 Off White; Chalky; Gran;Brown paper
" 13-WLSH-001-B-006 Off White; Chalky; Gran;Brown paper
13-WLJ-001-B-007 Off White; Chalky; Gran; Positive Stop
13-WLJ-001-B-008 Off White; Chalky; Gran;
" 13-WLJ-OOI-B-009 Off White; Chalky; Gran; .
l 3-WLPL-00 l-B-00 l 0 Off White;;Gray;Tan;Cementitious Positive ~top l 3-WLPL-00 l-B-00 U Off White; ;Gray;Tan;Cementitious " 13-WLPL-001-B-0012 OffWhite;;Gray;Tan;Cementitious Total # of Samples .Ll_ "
Date/Tinie Received.by Date/Time
03/17/2022 16d0 o I~
Page_l_of_l_
A
A-F-017 EXP: 2/4/2021
Client:
Contact:
Address:
Phone:
Fax:
EIJ!all:
Project:
Client Notes:
P.O.#.
Date Submitted:
Analysls:
TumAroundTime:
!Sample Number ~ 3:r=L \/<;T :.001 :S:.001
~ 3-FLVCT-001-8-002
~ 3-FLVCT-001-8-003
~ 3-WLSH-001-8-004
~ 3-WLSH-001-8-005
~ 3-WLSH-001 -8-006
rt 3-WLJ-001-8-007
3-WLJ.:()01-8-008
~ 3-WLJ-001-8-009
j13-WLPL-001-8-0010 i13~WLPL-001-B-0011 c1 3-WLPL-001-8-0012
802 CES/CEIE
Edward Vogel
*Instructions:
Use Column •a• for your contact inr6
1651 5th St W; Randolph AFB TX 7$150 21 0-652-4668 To See an Example Click the bottom Example Tab. 210-652-3605 edward.vogel@us.af.rnil
RND13_ 11050113_Remove File S
[Enter Client Notes Here)
[Enter P.O. # Here)
PLM
24 hrs
Data 1
3/17/2022 0:00
Enter samples between •« • and "»" Begin Samples with a "« "above the first saf(lple and end with a •» • below the last sample.
Only Enter your data on the "rst sheet "Sheet1"
Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you to facilitate your reintegration of the report data.
Sample Description
[Enter data of your choosing here) Tan floor tile; with mastics Tan floor tile; with mastics Tan floor tile; with mastics Off White; Chalky; Gran;Brown paper Off White; Chalky; Gran;Brown paper Off White; Chalky; Gran;Brown paper Off White; Chalky; Gran Off White; Chalky; Gran Off White; Chalky; Gran Off White;;Gray;Tan;Cementitious Off White;;Gray;Tan;Cementitious Off White ;;Gray;Tan;Cementitious
Sclentlf#c Analytical Institute ~ ~ l
4604.DUNDAS-Dr.
·1(ctct1iq0
Greensborq/ NC 27407 Phone:. 336.292.3888
Fax: 336,292.3313 ;
Email: lab@sailab.com i5aia2
Positive Stop
Positive Stop
Positive Stop
Positive Stop
JBSA Asbestos Inventory Print Report
Facility Type:
Facility Site: JBSA Randolph
Administrative
Square Footage: 91065Number of Floors: 2
B13.tifDrawing File Name:
Facility Status: Manned
13.jpgPhoto File Name
Date Constructed: 1931
Facility Number: Facility Name:13 HQ MAJOR COMD
Facility Owner: 502 ABW
Facility Address: 610284 HQ MAJOR COMD Asbestos:
Facility Summary Report:
03/02/2015 - Work Order
03/27/2013 - work Order 11242 - Install Light Switch Sensor and relocate Outlet - all Sheetrock and Joint compound is NAD, No Asbestos detected
10/18/2012 - workorder 11134- Customer is requesting an Environmental Assessment for Interior Hangar 13. This facility contains asbestos floor tiles and mastic throughout. Our Environmental Office is not trained to inspect for Mold or other Air qulaity issues. Sheetrock through out hanger is asbestos free. However, there is not enough indicative data to classify this hangar as asbestos free. Additional sampling is required and due to the size of the facility, it is our recommendation to hire a certified Asbestos, Inspector , mold inspector, and LBP inspector
10/28/2011 - Workorder 10638 - Install power outlets in room 507. All sheetrock, float mud and joint compound is NAD (No Asbestos Detected)
09/19/2011- K7334. Upgrade electrical power to hangar. We are currently unable to evaluate this project until a design and scope of work is established identifying areas that may disturb construction materials that would require an asbestos and Lead Based Paint Assessment.
09/16/2011 -Workorder 80076, Self Help Room 133- Self help disapproved for replacement of linoleum. Linoleum mastic is Asbestos containing Material at 8% Chrysotile. One Positive makes all linoleum and mastic positive.
08/292011 -workorder 10513 Relocate Door from 315 to room 316. All sheetrock in room 315 and 316 are NAD, No Asbestos Detected)
08/02/2011 - Workorder 10449 - Update NIPRNET - All proposed sheetrock penetrations are NAD (No Asbestos Detected) for this specific Project
06/14/2011 - Workorder 10416, Install outlet in Comm. Closet, Room 307, DSW, All sheetrock in Room 307, Comm. Closet is None Detect for Asbestos Containing Materials
05/03/2011 - Alarm System Replacement Project - Concrete Vault – No Asbestos Samples required
30 Aug 10, Workorder L5567, Repair 2' Hole in Concrete Floor and remove mold on wall. All drywall in this area is NAD, (No Asbestos Detected)
ViewFacility Comments:
18 Aug 10, Workorder L1207, Remove and Change Swinging Door to Single Wooden Door with Glass Insert, Rm 403, The materials in this room are similar to all of the sheetrock throughout this facility which has continuously resulted in NAD (No Asbestos Detected)
18 Aug 10, Workorder, L1218, Install Corkboard on walls Room 402 and Rm 406, Sheetrock and wall texture is NAD (No Asbestos Detected for this specific workorder
18 Aug 10, Workorder L1205, Replace Front Door, Fabric wall on the interior of the door and the exterior plaster wall is NAD for Asbestos Containing materials
8 Aug 10 L4064, Tear Down Paneling Install Wainscott;Paint and Texture - All wall mastic behind paneling is NAD (No Asbestos detected)
8 Aug 10, L1211, Cost estimate for painting interior walls of Hangar 13 - All Sheetrock walls are NAD (No Asbestos Detected) for Asbestos Continuing materials, All Fabric Covered walls are NAD
7 Aug 10, Workorder L1216, Replace Flooring Cabinets , etc in room 605 Breakroom -- Vinyl linoleum tiles are placed over asbestos floor tiles and black mastic. Do not Disturb. Any disturbance of this material by any abrasive or physical means.
Abatement must be done by a Certified Asbestos Abatement Team
2 Aug 10 - Workorder L1202, Replace Carpeting . Based on the survey below, all floor tiles and mastic throughout facility are Positive for Asbestos containing materials. Various areas throughout this facility have friable floor tiles. Therefore, all floor tiles and mastic must be abated.
17 Feb 10, K3342, Install Cypher Lock Doors Throughout facility. All Floor tiles and black mastic under the carpeting is Positive for Asbestos Containing materials. All Sheetrock and joint compound is NAD, (No Asbestos Detected) for this specific project
16 Feb 10, K7336, Install LCD Room 205C, Area for LCD Installation is NAD, (No Asbestos Detected)
Facility Comments:
Date User Comment
3/25/2022 elv 11050113_Remove file system from room 601. The following components are positive for asbestos containing materials. All floor tile and mastics, All Sheetrock, All float mud/Joint compound.
Do not disturb, coordinate all projects, abatement activities with the JBSA Envioronmental Office. The following component does not contain any asbestos materials All plaster walls are NAD, No Asbestos Detected.
11/5/2021 hwp NAD = No Asbestos Detected
11/5/2021 hwp Work Task 10205139 Build Addition in Room 507 - Be advised that the following components are positive for asbestos-containing materials (ACM): floor tiles and mastic throughout facility. Any areas not identified in attached report shall be assumed positive unless sampled and analyzed by a Texas certified asbestos laboratory.
4/3/2020 elv Work Task 7205197 - Renovate facility for Bed Down T7A. All floor tiles and Mastics throughout this facility is Positive for Asbestos Containing Materials. All Asbestos floor tiles and mastics will have to be abated by a licensed Asbestos Abatement Team.
All Sheetrock, fibrous cloth on walls Float Mud/Joint compound, accoustic ceiling tiles are all NAD, No Asbestos Detected. Any materials not listed in the reports are to be assumed positive for Asbestos Containing Materials or sampled at an approved Texas Asbestos Laboratory. Provide the JBSA Environmental Office a copy of any additional lab reports for further action as required.
5/20/2019 elv Request for energy and Ameresco contractors for potential areas of asbestos disturbance. Floor tile and mastics and Linoleum
Asbestos Containing Material (ACM) Results Dimension
AsbestosHSA DescriptionHSA Type Sample # Year ID Location(s) Floor Floor Area
Sample Area Original Sample IDSample ID
0L3. mastic 2, NAD, Non-fibrous 100%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 1 SF
Room - 601 01 SF13-FLVCT-001-B-001
0L2, tile, Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 1 SF
Room - 601 01 SF13-FLVCT-001-B-001
0L1, mastic 1, Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 1 SF
Room - 601 01 SF13-FLVCT-001-B-001
0L1, mastic 1,Positive Stop , Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 2 SF
Room - 601 01 SF13-FLVCT-001-B-002
0L2, tile, Positive Stop, Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 2 SF
Room - 601 01 SF13-FLVCT-001-B-002
0L3. mastic 2, NAD, Non-fibrous 100%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 2 SF
Room - 601 01 SF13-FLVCT-001-B-002
0L3. mastic 2, NAD, Non-fibrous 100%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 3 SF
Room - 601 01 SF13-FLVCT-001-B-003
0L1, mastic 1,Positive Stop , Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 3 SF
Room - 601 01 SF13-FLVCT-001-B-003
0L2, tile, Positive Stop, Chrysotile 3%, Non-fibrous 97%
2022 1
Tan floor tile;with masticsFloor - Vinyl Composite Tile 3 SF
Room - 601 01 SF13-FLVCT-001-B-003 throughout facility, Joint Compound has tested less than 1% therefore is not considered Asbestos Containing Materials according to NESHAP and OSHA. Any materials not listed on this report are to be assumed Positive for asbestos containing materials, or must be sampled prior to disturbance. Any disturbance of Asbestos Containing Materials must be done by a certified Asbestos Abatement Team.
4/2/2018 elv Assess mechanical equipment for DDC upgrade. All equipment materials are fiberglass insulation. Non-suspect for asbestos containing materials
12/18/2017 elv Work Order 13108 - Reconfigure Rooms 315 and 316. All joint Compound, Float Mud and floor tile and mastic are Positive for Asbestos Containing Materials. All work must be done by a certified asbestos abatemant team.
12/5/2016 elv Work Order 12586 - Assess area for repair or installation of new doors. All areas are NAD, No Asbestos Detected.
7/20/2015 elv Work Order 11880 - relocate Secretary 's Door. All sheetrock, Float Mud. Joint Compound and wall texture are NAD, No Asbestos Detected in both room 412 and room 414
3/23/2015 elv All floor tiles and mastics were abated from room 502 and the recycling storage area by In- House abatement team. Waste disposed of in Dumpster on base.
0Chrysotile 3%, Non-fibrous 97%
2022 1
Odff White; Chalky; Gran;Brown paperWall - Sheetrock 4 SF
Room - 601 01 SF13-WLSH-001-B-004
0Chrysotile 3%, Non-fibrous 97%
2022 1
Odff White; Chalky; Gran;Brown paperWall - Sheetrock 5 SF
Room - 601 01 SF13-WLSH-001-B-005
0Chrysotile 3%, Non-fibrous 97%
2022 1
Odff White; Chalky; Gran;Brown paperWall - Sheetrock 6 SF
Room - 601 01 SF13-WLSH-001-B-006
0NAD, Non-Fibrous 100%
2022 1
Odff White; Chalky; Gran;Wall - Joint Tape/Joint Compoud 7 SF
Room - 601 01 SF13-WLJ-001-B-007
0Chrysotile 3%, Non-fibrous 97%
2022 1
Odff White; Chalky; Gran;Wall - Joint Tape/Joint Compoud 8 SF
Room - 601 01 SF13-WLJ-001-B-008
0Positive Stop, Chrysotile 3%, Non-fibrous 97%
2022 1
Odff White; Chalky; Gran;Wall - Joint Tape/Joint Compoud 9 SF
Room - 601 01 SF13-WLJ-001-B-009
0NAD, Non-Fibrous 100%
2022 1
Off White;;Gray;Tan;CementitiousWall - Plaster 10 SF
Room - 601 01 SF13-WLPL-001-B-0010
0NAD, Non-Fibrous 100%
2022 1
Off White;;Gray;Tan;CementitiousWall - Plaster 11 SF
Room - 601 01 SF13-WLPL-001-B-0011
0NAD, Non-Fibrous 100%
2022 1
Off White;;Gray;Tan;CementitiousWall - Plaster 12 SF
Room - 601 01 SF13-WLPL-001-B-0012
JBSA LBP Inventory Print Report
Lead Based Paint Detected:
Acft Maintenance
Square Footage: 29218
Number of Floors: 2
None.dwg
Drawing File Name:
Facility Status: Manned
13.jpg
Photo File Name
Date Constructed: 1931
Facility Number: Facility Name:13 HQ MAJOR COMD
Facility Owner: 502 ABW
Facility Type:
Facility Address: 1550 5th Street East
Facility Summary Report:
A=West, B=North, C=East, D=South
03/27/2013 - Work Order 11242 - Install a light sensor switch. , relocate wall outlet. All sheetrock is Negative for LBP.
10/18/2012 - See Options for LBP survey Workorder 11134 - Environmental evaluation for Hangar. Inspect for LBP and Mold.
This facility has had a limited LBP inspection for specific projects where paint may be disturbed. LBP is not a hazard unless if the lead chips or dust is inhaled or ingested. These are the only routes of entry to cause potential exposure. A request to inspect the entire interior of the facility is too large to be done in-house in a single visit. With this being said, (Option 1), what we can provide is conduct a LBP survey 1 room per day until the entire assessment is complete(Option 2), recommend contracting it out to a Department of State Health Services, Licensed Lead Inspector. Some Lead Inspectors are also certified to conduct mold or other Air Quality inspections and make recommendations. These companies can be found on the DSHS Web Site. Conduct a search for Texas Lead Program, or Texas Mold program. Qualified firms will be listed for these programs. (Option 3), Contract Air Quality Assessment and we can conduct the LBP survey as recommended in Option 1. Depending on our workload with other work orders and construction projects, we may be able to do more than one room per visit if you require any assistance or further recommendations, give us a call and we will assist. Let us know which option you prefer. If option is for contract out LBP survey, a copy of any LBP report must be provided to our office electronically in an xcel spreadsheet.
10/24/2011, WO#10638 Install electrical outlet above entrance of room 507, area tested is negative for LBP.
09/12/2011, WO# 80076 Renovate room 133, areas tested are negative for LBP.
08/19/2011, WO#10513 Relocate door in rm 316, areas tested are negative for LBP
7/26/11, WO#10449 Upgrade NPRNET, areas tested are negative for LBP
8/6/2011, WO#10416, Install two outlets in room 307, Areas tested are negative for LBP
5/18/2011, WO#80058, Paint hallway entrance, brown wainscott is negative for LBP
5/16/2011, WO#10323 Seal Hangar Doors, All areas tested are positive for LBP, Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater
05/03/2011 - Replace ADT Alarm project - Concrete Vault Assume Positive for Lead Based Paint
Facility Site: JBSA Randolph
ViewFacility Comments:
LBP Report File Name(s):
2015-04-27_13_11777_H13_Inst
11 Mar 2011, Chilled Water Project, WO#10113, Performed tests for LBP in close proximity of where new chilled water lines have to be connected on interior and exterior walls for penetration, areas tested were negative for LBP
30 Aug 10, Workorder L5567 - Investigate Mold and hole in Drywall., SW Entry .All drywall is Negative for Lead Based Paint. All Concrete walls are Positive for Lead Based Paint and are peeling severely. This workorder should not disturb the Concrete Walls.Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for the concrete walls. Refer to IDIQ Paint contractor for LBP. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater
18 Aug 10, Workorder L1207, Remove and Change Swing Double Door to Single Door -- There was a positive indication for LBP behind the paneling on all walls, Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. The existing door and Door Casing is Negative for LBP.
18 Aug 10, Work Order L1218, Install Corkboard in Room 402 and 406, In room 403, There wa a positive indication for LBP behind the paneling on all walls, IN rom 402 there was an indication of LBP behind the paneling on East and South Walls.Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping blasting, drilling or any brazing/welding operations.etc. OSHA 29 CFR 1926.62 rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater
18 Aug 10, Workorder L1205, Replace Front Door, All exterior walls are Positive for Lead Based Paint
17 Feb 10,K4332, All sheetrock walls throughout this facility are Negative for LBP
16 Feb 10, K7336, Install TV, All Areas are Negative for LBP
Facility Comments:
Date User Comment
3/25/2022 elv WT 11050113 remove file system from room all plaster walls are positive for Lead Based Paint. Do not disturb by any mechanical or physical means. Any disturbance must be done by a certified Lead Firm.
11/5/2021 hwp Work Task 10205139 Build Addition in Room 507 - All areas analyzed in Room 507 are negative for lead-based paint (LBP).
However, areas which are hidden behind walls are to be assumed positive unless proven otherwise by EPA-approved methods.
1/21/2021 elv Request for information regarding LBP on exterior of hangar and hangar doors. Any reading greater than .1mg per square centimeter is positive for lead based paint. OSHA 29 CFR 1926.62 Lead In construction rules will apply for these areas. At the minimum, a negative exposure assessment would apply. All waste materials other than metal will have to have a TCLP for RCRA metals. All metals may be disposed of as RCRA metals at an approved EPA recycling Facility that is authorized to accept Lead.
A recycling certificate is required, Waste profiles shall be developed and approved by the JBSA Hazardous Waste Manager and waste manifested appropriately and signed by a authorized 802 CES Environmental Representative
1/7/2021 elv Contractor request for sampling specific components. A wooden wall on the south East of one room and a dry wall with door assembly in a different room. The wooden wall and the wooden door components assessed are Positive for Lead Based Paint.
The results were low but meets the criteria of any amount according to OSHA 29 CFR 1926.62. Any material that exceeds .1 mg per square centimenter is Lead Based Paint. Any disturbance of these components must be done by a certified Lead Firm that has received Lead safe training by an EPA training provider. These materials may be disposed of as construction debris since the levels are low.
4/3/2020 elv Work Task 7205197 - Renovate areas for T7A Beddown. The following items are Positive for Lead. All wood paneling, all Concrete Surfaces and SE Exterior Door. If there is not a component listed in this report and the paint is to be disturbed, call 210-652-3605 and we will analyze the component for Lead Based Paint. Do not disturb any surfaces with Lead Based Paint by drilling, sanding, scraping or any other abrasive method that could disturb the Lead Paint. Any Lead work must be done by a Lead Awareness trained team that will comply with 29 CFR 1926.62, Lead IN construction Rules All other surfaces are Negative for Lead Based Paint
4/30/2019 elv Provide Lead Survey for Hangar 13 Project. All exterior concrete surfaces. Wood Paneling all Hangar Doors and the SE Door and components are Positive for Lead Based Paint. The interior of the doors were inaccessible. A Negative Exposure Assessment is required in acoordance with OSHA 29 CFR 1926.62, Lead In Construction Rules. Any disturbance must be done by a certfified Lead Firm or a team that has completed a OSHA Lead Awareness Training Course
3/29/2017 HMUserelv Work Order T8266 - Replace Door and Casing. The concrete wall on the left of the metal casing from inside room 606 and the exterior is Positive for Lead Based PaintThe Door, metal casing, and the concrete wall on the right are Negative for Lead Based Paint.
4/6/2016 elv All concrete walls are positive for lead based paints, floor tiles are suspect for asbestos containing materials. Door Casing is Positive for Lead Based paint.Do not disturb any areas that are POS for LBP by any abrasive means such as sanding, scraping power washing, blasting, drilling or any brazing/welding operations etc.
OSHA 29 CFR 1926.62 Lead in Construction Rules will apply for this project. The OSHA requirement for these rules apply for any amount of LBP .1 mg/cm2 or greater. This work must be done by a certified Lead Firm. The door and casing may be recycled at the JBSA Randolph recycling facility which is authorized to accept RCRA metal.
3/14/2016 elv Work Order 12433 - repaint Commanders wall in room 416. All wall surfaces are intact and all surfaces are negative for Lead Based Paint.
7/20/2015 elv Work Order 11880 - Relocate Secretary's Door. All areas are Negative for Lead Based Paint
4/27/2015 elv Work Order 11777 - Install sign exterior of exit. There is an inconclusive results for Lead Based Paint on the concrete exterior wall near the main entrance. All other areas are Negative for Lead Based Paint The lead Level is so low, that the area may be drilled wet by CEO utilizing a mist spray of water and a certified HEPA vaccum which may be signed out by our office.
2/12/2015 elv Work Order 11827 Cover existing markings for parking and redesignate - all markings are Negtative for Lead Based Paints.
18 3/15/2022 0.06 0.04601 A Center Wall Plaster Off White Deteriorate Positiv
19 3/15/2022 0.29 0.22601 B Center Wall Plaster Off White Deteriorate Positiv
20 3/15/2022 0.05 0.06601 C Center Wall Plaster Off White Deteriorate Positiv
21 3/15/2022 0 0601 C Center Wall Gypsum Off White Deteriorate Negativ
22 3/15/2022 0 0601 D Center Wall Gypsum Off White Deteriorate Negativ
Sample Date Room Side Quadrant Component Substrate Color Condition Pb+ Pb- Results
| 71987896_PLM |
| JBSA Asbestos Containing Materials Inventory Report |
| JBSA LBP Containing Materials Inventory Report |
File details come from the government source that posted it. Updated .