B127 Door Lock layout.pdf

PDF 453 KB Posted

Attached to
CAC Door Lock Access Control System & Install Bldg 127 JBSA Lackland Federal contract opportunity
Solicitation number
FA301621Q0034
Issued by
Department of the Air Force Air Education and Training Command

About this file

This solicitation is for a CAC enabled door lock access control system and installation at Building 127 at Joint Base San Antonio Lackland. The Air Force is seeking quotes to provide and install CAC locks and access control systems for all exterior doors, student rooms, offices, common areas, laundry rooms and other spaces depicted in the building floorplans attached. The requirement includes approximately 68 locks for student rooms, 9 for offices and other access points as detailed. The NAICS code for this opportunity is 561622 and it is restricted to small businesses with a size standard of $20.5 million. Quotes are due by the date specified in the solicitation number FA301621Q0034 issued by the Air Force Air Education and Training Command.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MTL

Offices

C120 Dayroom

C127 Comm Room

CQ

Elevator Janitor Closet

W114 W116 W118 W120 W122W102 W104 W106 W108 W110 W112

W115 W117 W119 W121 W123W103 W105 W107 W109 W111 W113 W125

N102 N103

N104 N105

N106 N107

N108 N109

N110

N112

N114

N116

N111

N113

N115

N117

Si d e R o o m Women’s Restroom

W124 E112 E110 E108 E106 E104E124 E122 E120 E118 E116 E114 E102

E113 E111 E109 E107 E105E125 E123 E121 E119 E117 E115 E103C116C117

V en d /M ec h

SAC

N

C122 Laundry Room

Bldg. 127 Floorplan 1st

W E

C130A, B Briefing

Room

Men’s Restroom

Stairs

66 - STUDENT ROOMS

5 - EXTERIOR EXITS (2 DOORS EA)

Only front door gets reader

2 – BRIEFING ROOM - C130A, B

1 -- LAUNDRY – C122

1 – DAYROOM – C120

= 68 CAC LOCKS & 4 PIN LOCKS

C124 C125

5TH EXTERIOR EXIT

ADMIN/MTL SPACES

2 – EXTERIOR DOORS (C108A,B)

1 – SAC - C113

1 – COMPUTER RM – C109

9 – OFFICES – C103,4,5,6,7,10,11,12,14

= 2 CAC LOCKS & 11 PIN LOCKS

C201 Storage

Computer

C220 Mech

C209 Dayroom

C

C o m m

Janitor Closet

W214 W216 W218 W220 W222W202 W204 W206 W208 W210 W212

W215 W217 W219 W221 W223W203 W205 W207 W209 W211 W213 W225

N202 N203

N204 N205

N206 N207

N208 N209

N210

N212

N214

N216

N211

N213

N215

N217

W224 E212 E210 E208 E206 E204E224 E222 E220 E218 E216 E214 E202

E213 E211 E209 E207 E205E225 E223 E221 E219 E217 E215 E203C204

C206 C

V en d

N

C211 Laundry Room

Bldg. 127 Floorplan 2nd

W E

C219 linen/HP

Stairs

C205 REC

Elevator

C

C216 CE

C214

C

O ff ic e

66 - STUDENT ROOMS

1 -- LAUNDRY – C122

1 – DAYROOM – C120

3 – COMMON/STORAGE - C201, C205, C219

1 – DORM MNGR – C215 (CE ELEC RM ALSO)

= 66 CAC LOCKS & 6 PIN LOCKS (IF DORM

MNGR)

C202

NOT A STORAGE ROOM

C312

Dayroom

Elevator

Janitor Closet

W314 W316 W318 W320 W322W302 W304 W306 W308 W310 W312

W315 W317 W319 W321 W323W303 W305 W307 W309 W311 W313 C317 C315

N302 N303

N304 N305

N306 N307

N308 N309

N310

N312

N314

N316

N311

N313

N315

N317

W324 E312 E310 E308 E306 E304E324 E322 E320 E318 E316 E314 E302

E313 E311 E309 E307 E305E325 E323 E321 E319 E317 E315 E303C304C305

C

V en d

N

C311 Laundry Room

Bldg. 127 Floorplan 3rd

W E

Stairs

W325

C

C301 Storage

C320 Storage

C302C319

C

M ec h

C

C o m m

68 - STUDENT ROOMS

1 -- LAUNDRY – C311

1 – DAYROOM – C3??

2 – COMMON/STORAGE – C301, C320

= 68 CAC LOCKS & 4 PIN LOCKS