Attachment 3 - Exteriors Phase 3 DWG_2 Aug 2021.pdf
PDF 844 KB Posted
- Attached to
- Maintain Exterior Coatings of Multiple Facilities Federal contract opportunity
- Solicitation number
- FA301021R0018
About this file
This is a solicitation for maintenance of exterior coatings at multiple facilities located at Keesler Air Force Base in Mississippi. The solicitation is a 100% HUBZone set-aside issued by the Department of the Air Force Air Education and Training Command with an estimated value between $250,000 and $500,000. Services required include pressure washing, cleaning, repairing cracks and seals, and repainting exterior walls, soffits, ceilings, doors and windows of six buildings constructed of materials including stucco, EIFS, CMU and brick. An organized site visit will be held on July 22, 2021 for offerors to inspect the facilities. Proposals are due based on instructions in Sections L and M, with award to be made on an all or some basis depending on available funding. The period of performance will be between 60 to 120 days depending on funding.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 002 - SF 30.pdf | ||
| Amendment 001 - SF 30.pdf | ||
| Attachment 1 - Exteriors Phase 3 SOW_2 Aug 2021.pdf | ||
| Attachment 10 - Questions_Answers_2 Aug 2021.pdf | ||
| Site Visit Sign-In_22 July.pdf | ||
| Attachment 5 - Wage Det MS20210050_2 Apr 2021.pdf | ||
| Attachment 7 - Past Performance Questionnaire.pdf | ||
| Attachment 3 - Exteriors Phase 3 DWG_13 May 2021.pdf | ||
| Attachment 6 - Past Performance Reference List.pdf | ||
| Attachment 1 - Exteriors Phase 3 SOW_6 July 2021.pdf | ||
| Attachment 9 - Notice of Compliance.pdf | ||
| Attachment 4 - Exteriors Phase 3 MSS_6 July 2021.xls | XLS spreadsheet | |
| Solicitation - FA301021R0018.pdf | ||
| Attachment 2 - Exteriors Phase 3 SPECS_6 July 2021.pdf | ||
| Attachment 8 - SF 1444.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Deer Island
Ship IslandCat Island
St. Louis Bay
Mis siss ipp i
Sou nd
Big Lake
Back Bay of Biloxi
Bernard Bayou
W olf
R iv er
Biloxi River
Little Biloxi River
Tchoutacabouffa
River
Tuxachanie
Creek
Tch out aca bou ffa
Riv er
Cedar Lake
S a u c ie r
C re e k
Miss issip pi
Soun d
INTERSTATE 10
U .S
. H W
Y 49
U.S. HWY 90
I-1
LA
R
C H
ER
B
LV
D
GEN CHAPPIE JAMES AVE
PARADE LN
PRJOECT SITE
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE
MAINTAIN EXTERIOR COATING SYSTEMS
KEESLER AFB, MISSISSIPPI
MAY 13, 2021
MAHG141001
MAHG141001 6
C. STEWART
ABBREVIATIONS
ABA AMERICAN BARRIERS ACT
AFF ABOVE FINISH FLOOR
ACT ACOUSTICAL CEILING TILE
BD BOARD
CONC. CONCRETE
CONT CONTINUOUS
CPT CARPET
CT CERAMIC TILE
ELECT ELECTRIC
GWB GYPSUM WALL BOARD
GYP GYPSUM
HORZ HORIZONTAL
HVAC HEATING VENTING AIR CONDITIONING
MAX MAXIMUM
MECH MECHANICAL
MIN MINIMUM
MLWK MILLWORK
OC ON CENTER
PLAM PLASTIC LAMINATE
PLUM PLUMBING
PLYWD PLYWOOD
PNT PAINTED
PT PORCELAIN TILE
RCP REFLECTED CEILING PLAN
TYP TYPICAL
VCT VINYL COMPOSITION TILE
VNYL VINYL
VERT VERTICAL
W/ WITH
WD WOOD
INDEX OF
1 T1.0 TITLE SHEET
2 A1.0 FLOOR PLAN - BUILDING 2804
3 A1.1 FLOOR PLAN - BUILDING 3710/4106
4 A1.2 FLOOR PLAN - BUILDING 4116
5 A1.3 FLOOR PLAN - BUILDING 6950
6 A1.4 FLOOR PLAN - BUILDING 7320
13 MAY 2021
2804, 3710, 4106, 4116, 6950, 7320
T1.0
C. STEWART
MAINTAIN EXTERIOR COATING
SYSTEMS
GENERAL NOTES
1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO
FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS
DESIGNED.
2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.
CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION
MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY
FASHION.
4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY
WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO
PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR
SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.
5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND
MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.
A1.0
A1.0
A1.0 5
A1.04
- 3
1'
2"
- 1 3'
8"
- 3
1'
2"
+/- 109' - 4 3/4"
- 1
7'
6"
- 3
1'
2"
- 1 3'
8"
- 3
1'
2"
- 7
6'
0"
- 7
6'
0"
+/- 271' - 9"
+/- 5' - 11 1/2"
- 2
9'
4"
- 4
- 9
- 4
- 2
9'
4"
A
A
B A
A
A
BA
BA
B
A
B
B
B
B
A B
A B
A
A
B A
A
A
BA
BA
BA
B
A
B
B
B
B
A B
A B
+/- 148' - 3 1/4"
14' - 1"
D
D
D
D D
D
D
D
F G
F G
F G F G
F G
F G
A BA B D F G
GF
GF
- 1
2'
1"
- 1 1'
8" +/
- 2 3'
9"
- 1
8'
4"
- 1
4'
5"
- 1
4'
5"
- 1
8'
4"
A DB F G
E
- 2
3'
9"
- 1
4'
5"
- 1
1'
8"
- 1
8'
4"
- 2
3'
9"
A DB F G
E
- 1
4'
5"
- 1
8'
4"
- 1
2'
5"
- 1
1'
8" +/
- 2
3'
9"
A DB F G
- 1
2'
5"+/
- 2
3'
9"
- 1
4'
5"
- 1
8'
4"
- 1
4'
5"
- 1
8'
4"
A DB F G
BUILDING DIMENSION INFORMATION - 2804
EXTERIOR WALL SURFACE AREA (EIFS) = +/-9,388 SF
DEMO/RENOVATION KEY NOTES
A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE FROM BUILDING EXTERIOR SURFACE - ALL
WALLS, SOFFITS, OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY PRESSURE WASH.
PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE;
COLOR TO MATCH EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).
B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.) AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH COAT(S) (2 COATS); COLOR TO MATCH EXISTING.
C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS, OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY PRESSURE WASH.
PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL CMU BUILDING EXTERIOR SURFACE; COLOR
TO MATCH EXISTING.
D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING (CREAM), OR EQUAL.
E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR EQUAL. SEAL ALL
BRICK WALLS IN ACCORDANCE WITH SOW, SPECIFICAITONS, AND DRAWINGS.
F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY); COLOR TO MATCH MEDIUM BRONZE, OR
EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND HOVERHANGS.
G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR. APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL
MATERIAL. PRIME AND PAINT.
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE 3/32" = 1'-0"1 FLOOR PLAN - 2804
MAHG141001 6
C. STEWART
13 MAY 2021
A1.0
C. STEWART
MAINTAIN EXTERIOR COATING
SYSTEMS
1/16" = 1'-0"2 EXTERIOR ELEVATION 2804 - SOUTH
1/16" = 1'-0"3 EXTERIOR ELEVATION 2804 - NORTH
1/16" = 1'-0"4 EXTERIOR ELEVATION 2804 - EAST
1/16" = 1'-0"5 EXTERIOR ELEVATION 2804 - WEST
2804, 3710, 4106, 4116, 6950, 7320
ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE
APPROXIMATE. CONTRACTOR IS ENCOURAGED TO FIELD
VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID
DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO
FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS
DESIGNED.
2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.
CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION
MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY
FASHION.
4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY
WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO
PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR
SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.
5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND
MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.
+/- 10' - 0"
- 1
2'
0"
A
A
A
A
C
C
C
C
A
AA
A
/4
24' - 3 1/4" 112' - 0 1/4" 24' - 3 1/2"
160' - 7"
/4
9'
/4
/4
/4
32' - 7" 103' - 8 1/4" 24' - 3 1/2"
160' - 7"
/4
B
B
A B
B
B
AB
A B
D D
D
D
D
D
D
GF
A B D GF
A B D GF
F G
F G
F G
GF
FG
FG
DEMO/RENOVATION KEY NOTES
A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH
EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).
B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)
AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT
ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN
MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH
COAT(S) (2 COATS); COLOR TO MATCH EXISTING.
C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.
D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE
NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL
CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING
(CREAM), OR EQUAL.
E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS
EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY
ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR
EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,
SPECIFICAITONS, AND DRAWINGS.
F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY),
GUTTERS, AND DOWNSPOUTS. COLOR TO MATCH MEDIUM BRONZE,
OR EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES,
LOUVERS, AND HOVERHANGS.
G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED
DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED
METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED
AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.
APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL
MATERIAL. PRIME AND PAINT.
A G
- 2
6'
- 1
0'
7"
B D F
A GB D F
+/- 3' - 0"
- 7
" B
- 2
6'
- 1
0'
7"
A GB D F
A GB D F
A GB D F
B
- 2
6'
+/- 0' - 4" B +/- 1' - 6"
- 8
B
A
- 1
3'
4"
- 1
3'
4"
D
A GB D F
A GB D F
B
- 7
+/- 3' - 3"
B +/- 2' - 5"
- 2
A
B
- 2
6'
- 1
3'
4"
- 1
3'
4"
A GB D F A GB D F
- 1
2'
0"
A C
- 1
2'
0"A C
- 1
2'
0"A C
- 1
2'
0"A C
3709 (LARCHER CHAPEL)
LA
R
C H
ER
B
LV
D
GEN CHAPPIE JAMES AVE
BUILDING DIMENSION INFORMATION - 3710
EXTERIOR WALL SURFACE AREA (CMU) = +/-464 SQUARE FEET
BUILDING DIMENSION INFORMATION - 4106
EXTERIOR WALL SURFACE AREA (EIFS) = +/-13,004 SQUARE FEET
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE
MAHG141001 6
C. STEWART
13 MAY 2021
A1.1
C. STEWART
3/16" = 1'-0"6 FLOOR PLAN - 3710
3/32" = 1'-0"5 FLOOR PLAN - 4106
MAINTAIN EXTERIOR COATING
SYSTEMS
1/16" = 1'-0"3 EXTERIOR ELEVATION 4106 - NORTH
1/16" = 1'-0"1 EXTERIOR ELEVATION 4106 - SOUTH
1/16" = 1'-0"2 EXTERIOR ELEVATION 4106 - EAST
1/16" = 1'-0"4 EXTERIOR ELEVATION 4106 - WEST
2804, 3710, 4106, 4116, 6950, 7320
3/16" = 1'-0"7 EXTERIOR ELEVATION 3710 - EAST
3/16" = 1'-0"8 EXTERIOR ELEVATION 3710 - NORTH
3/16" = 1'-0"9 EXTERIOR ELEVATION 3710 - SOUTH 3/16" = 1'-0"10 EXTERIOR ELEVATION 3710 - WEST
1" = 200'-0"
KEY PLAN - 3710
ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE
DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO
FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS
DESIGNED.
2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.
CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION
MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY
FASHION.
4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY
WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO
PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR
SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.
5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND
MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.
DEMO/RENOVATION KEY NOTES
A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH
EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).
B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)
AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT
ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN
MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH
COAT(S) (2 COATS); COLOR TO MATCH EXISTING.
C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.
D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE
NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL
CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING
(CREAM), OR EQUAL.
E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS
EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY
ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR
EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,
SPECIFICAITONS, AND DRAWINGS.
F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY),
GUTTERS, AND DOWNSPOUTS. COLOR TO MATCH MEDIUM BRONZE,
OR EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES,
LOUVERS, AND HOVERHANGS.
G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED
DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED
METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED
AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.
APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL
MATERIAL. PRIME AND PAINT.
A
A
8'
4"
4'
4"
302' - 0"
30' - 8"
30' - 8"
B
A B
B
AB
MAIN BUILDING ROOF
EXISTING
PENTHOUSE
ROOF
EXISTING
PENTHOUSE
ROOF
EXISTING
PENTHOUSE
ROOF
EXISTING
PENTHOUSE
ROOF
EXISTING
PENTHOUSE
ROOF
EXISTING
PENTHOUSE
ROOF
D
D
D
F G
DFG
F G
A B D F G
ABDFG
ABDFG
F
G
A B D F G
A B D F G
A B D F G
- 4
1'
8"
- 2
7'
5"
- 1 4'
3"
TOP OF MAIN BULDING ROOF
TOP OF PENTHOUSE ROOF
A GB D F
BUILDING DIMENSION INFORMATION - 4116
EXTERIOR WALL SURFACE AREA - BUILDING AND PENTHOUSES (EIFS) = +/-40,216 SF
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE
MAHG141001 6
C. STEWART
13 MAY 2021
A1.2
C. STEWART
MAINTAIN EXTERIOR COATING
SYSTEMS
3/64" = 1'-0"1 ROOF PLAN - 4116
2804, 3710, 4106, 4116, 6950, 7320
1/16" = 1'-0"2 EXTERIOR ELEVATION 4116 - TYPICAL
NOTE: THIS EXTERIOR ELEVATION IS FOR REFERENCE TO BUILDING HEIGHT ONLY. IT IS TYPICAL TO
ALL EXTERIOR SIDES OF BUILDING IN REFERENCE TO BUILDING HEIGHT
ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE
C118
RECEPTION/
BRIEFING
C117
WOMEN
C123
MEN
C128
CORR.
C120
ELECT.
C121
BOILER ROOM
C116
VENDING
C122
ELEV/ MECH
C101
LOBBY
C110
MTL HALL
C115
OFFICE
C114
OFFICE
C113
OFFICE
C112
OFFICE
C111
OFFICE
C114 C108
OFFICE
C107
OFFICE
C106
STORAGE
C104
OFFICE
C103
OFFICE
C130
STAIRS
C127
DAY ROOM
S125
LIVING UNIT
C125
LAUNDRY
S124
LIVING UNIT
W121
LIVING UNIT
W120
LIVING UNIT
W118
LIVING UNIT
W119
LIVING UNIT
C132
LIVING UNIT
C133
LIVING UNIT
C100
LOBBY
S123
LIVING UNIT
S122
LIVING UNIT
S121
LIVING UNIT
S120
LIVING UNIT
S119
LIVING UNIT
S118
LIVING UNIT
S117
LIVING UNIT
S116
LIVING UNIT
S115
LIVING UNIT
S114
LIVING UNIT
S113
LIVING UNIT
S112
LIVING UNIT
S111
LIVING UNIT
S110
LIVING UNIT
S109
LIVING UNIT
S108
LIVING UNIT
S107
LIVING UNIT
S106
LIVING UNIT
S105
LIVING UNIT
S104
LIVING UNIT
S103
LIVING UNIT
S102
LIVING UNIT
S101
ELEC
S127
VESTIBLE
S100
STAIRS
E120
LIVING UNIT
E121
LIVING UNIT
E118
LIVING UNIT
E119
LIVING UNIT
E116
LIVING UNIT
E117
LIVING UNIT
E114
LIVING UNIT
E115
LIVING UNIT
E112
LIVING UNIT
E113
LIVING UNIT
E110
LIVING UNIT
E111
LIVING UNIT
E108
LIVING UNIT
E109
LIVING UNIT
E106
LIVING UNIT
E107
LIVING UNIT
E104
LIVING UNIT
E105
LIVING UNIT
E102
LIVING UNIT
E103
LIVING UNIT
E100
STAIR
E123
VESTIBULE
E101
ELEC.
W116
LIVING UNIT
W117
LIVING UNIT
W114
LIVING UNIT
W115
LIVING UNIT
W112
LIVING UNIT
W113
LIVING UNIT
W110
LIVING UNIT
W111
LIVING UNIT
W108
LIVING UNIT
W109
LIVING UNIT
W106
LIVING UNIT
W107
LIVING UNIT
W104
LIVING UNIT
W105
LIVING UNIT
W102
LIVING UNIT
W103
LIVING UNIT
W101
ELEC.
W103
VEST.
W100
STAIRS
C114
JANITOR'
CLOSET
KEESLER HALL
NO 2
DAVIS MANOR
GENERAL NOTES
1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO
FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS
DESIGNED.
2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.
CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION
MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY
FASHION.
4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY
WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO
PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR
SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.
5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND
MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.
+/- 160' - 11"+/- 49' - 2 1/4"+/- 18' - 9 1/4"+/- 49' - 1 1/4"+/- 161' - 0"
+/- 439' - 0 1/4"
- 1
6'
8"
- 4 0'
6"
- 1
6'
4"
- 7
3'
6"
- 1
0'
0"
- 2
/4
- 2
/4
+/- 10' - 0"
+/- 180' - 11"+/- 10' - 0" +/- 180' - 10 3/4"
+/- 190' - 11" +/- 190' - 11"
A B
BAA B
A B
BA
A B
A B
A B
AB
D D
D
D
D
D
D
D
F G
F G
F G F G
AB
AB
D
D
FG
FG
F G
D F G
F
G
B A
D F
G
F G F G
DEMO/RENOVATION KEY NOTES
A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH
EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).
B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)
AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT
ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN
MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH
COAT(S) (2 COATS); COLOR TO MATCH EXISTING.
C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.
D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE
NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL
CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING
(CREAM), OR EQUAL.
E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS
EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY
ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR
EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,
SPECIFICAITONS, AND DRAWINGS.
F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY),
GUTTERS, AND DOWNSPOUTS. COLOR TO MATCH MEDIUM BRONZE,
OR EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES,
LOUVERS, AND HOVERHANGS.
G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED
DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED
METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED
AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.
APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL
MATERIAL. PRIME AND PAINT.
- 3
4'
2"
- 1
0'
8" +/
- 3
4'
2"
- 1
0'
8"
- 2
3'
6"
- 1 0'
8" +/
- 3 4'
2"
- 2
3'
6"
- 1 0'
8" +/
- 3 4'
2"
EIFS
BRICK
EIFS
BRICK
EIFS
BRICK
EIFS
BRICK
E
E
E
E
F
F
F
F
F
F
A B D G
A B D G
A B D G
A B D G
BUILDING DIMENSION INFORMATION - 6950
EXTERIOR WALL SURFACE AREA (EIFS) = +/-33,986 SF
EXTERIOR WALL SURFACE AREA (BRICK) = +/-15,819 SF
EXTERIOR WALL SURFACE (TOTAL) = +/-49,805 SF
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE
MAHG141001 6
C. STEWART
13 MAY 2021
A1.3
C. STEWART
1" = 30'-0"1 FLOOR PLAN - 6950
MAINTAIN EXTERIOR COATING
SYSTEMS
2804, 3710, 4106, 4116, 6950, 7320
1/32" = 1'-0"2 EXTERIOR ELEVATIONS 6950 - OVERALL
ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE
C118
RECEPTION/
BRIEFING
C117
WOMEN
C123
MEN
C128
CORR.
C120
ELECT.
C121
BOILER ROOM
C116
VENDING
C122
ELEV/ MECH
C101
LOBBY
C110
MTL HALL
C115
OFFICE
C114
OFFICE
C113
OFFICE
C112
OFFICE
C111
OFFICE
C109 C108
OFFICE
C107
OFFICE
C106
STORAGE
C104
OFFICE
C103
OFFICE
C130
STAIRS
C127
DAY ROOM
S125
LIVING UNIT
C125
LAUNDRY
S124
LIVING UNIT
C132
LIVING UNIT
C133
LIVING UNIT
C100
LOBBY
S123
LIVING UNIT
S122
LIVING UNIT
S121
LIVING UNIT
S120
LIVING UNIT
S119
LIVING UNIT
S118
LIVING UNIT
S117
LIVING UNIT
S116
LIVING UNIT
S115
LIVING UNIT
S114
LIVING UNIT
S113
LIVING UNIT
S112
LIVING UNIT
S111
LIVING UNIT
S110
LIVING UNIT
S109
LIVING UNIT
S108
LIVING UNIT
S107
LIVING UNIT
S106
LIVING UNIT
S105
LIVING UNIT
S104
LIVING UNIT
S103
LIVING UNIT
S102
LIVING UNIT
S101
ELEC
S127
VESTIBLE
S100
STAIRS
E116
LIVING UNIT
E117
LIVING UNIT
E114
LIVING UNIT
E115
LIVING UNIT
E112
LIVING UNIT
E113
LIVING UNIT
E110
LIVING UNIT
E111
LIVING UNIT
E108
LIVING UNIT
E109
LIVING UNIT
E106
LIVING UNIT
E107
LIVING UNIT
E104
LIVING UNIT
E105
LIVING UNIT
E102
LIVING UNIT
E103
LIVING UNIT
E100
STAIR
E123
VESTIBULE
E101
ELEC.
W116
LIVING UNIT
W117
LIVING UNIT
W114
LIVING UNIT
W115
LIVING UNIT
W112
LIVING UNIT
W113
LIVING UNIT
W110
LIVING UNIT
W111
LIVING UNIT
W108
LIVING UNIT
W109
LIVING UNIT
W106
LIVING UNIT
W107
LIVING UNIT
W104
LIVING UNIT
W105
LIVING UNIT
W102
LIVING UNIT
W103
LIVING UNIT
W101
ELEC.
W103
VEST.
W100
STAIRS
C131
JANITOR'
CLOSET
KEESLER HALL
NO 2
CONNER MANOR
+/- 131' - 1"+/- 49' - 2 1/4"+/- 18' - 9 1/4"+/- 49' - 1 1/4"+/- 131' - 2"
+/- 379' - 4"
- 1
6'
8"
- 4 0'
6"
- 5
7'
2"
+/- 151' - 0 3/4"+/- 10' - 0" +/- 151' - 0 3/4" +/- 10' - 0"
+/- 161' - 0 3/4" +/- 161' - 1"
- 1
0'
0"
- 2
- 2
- 1
6'
8"
- 4 0'
6"
- 5
7'
2"
A B AB
A B AB
AB
AB
+/- 40' - 6" +/- 16' - 8 1/4"
+/- 57' - 2 1/4"
A B
AB
A B
AB A B
A B
D D
D
D
D
D D
D
D
D
D
F G F G
F G
FG
F G
F G F G
F G
F GF G
F G
DEMO/RENOVATION KEY NOTES
A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH
EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).
B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)
AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT
ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN
MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH
COAT(S) (2 COATS); COLOR TO MATCH EXISTING.
C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE
FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,
OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY
PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH
WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER
DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL
CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.
D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE
NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL
CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING
(CREAM), OR EQUAL.
E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS
EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY
ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR
EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,
SPECIFICAITONS, AND DRAWINGS.
F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY),
GUTTERS, AND DOWNSPOUTS. COLOR TO MATCH MEDIUM BRONZE,
OR EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES,
LOUVERS, AND HOVERHANGS.
G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED
DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED
METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED
AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.
APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL
MATERIAL. PRIME AND PAINT.
GENERAL NOTES
1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO
FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND
START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY
CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS
DESIGNED.
2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.
CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION
MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY
FASHION.
4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY
WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO
PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR
SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.
5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND
MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.
- 1
0'
8"
- 2 3'
6"
- 3
4'
2"
- 1
0'
8"
- 2 3'
6"
- 3
4'
2"
- 1
0'
8"
- 2 3'
6"
- 3
4'
2"
- 1
0'
8"
- 2 3'
6"
- 3
4'
2"
EIFS
BRICK
EIFS
BRICK
EIFS
BRICK
EIFS
BRICK
E
E
E
E
F
F
F
F
F
F
A B D G
A B D G
A B D G
A B D G
F
F
BUILDING DIMENSION INFORMATION - 7320
EXTERIOR WALL SURFACE AREA (EIFS) = +/-34,513 SF
EXTERIOR WALL SURFACE AREA (BRICK) = +/-16,064 SF
EXTERIOR WALL SURFACE (TOTAL) = +/-50,577 SF
G. REED
A. MARASCA G. REED
VARIES
C. STEWART
876543
D
E
B
C
A
87654321
G
F
E
D
C
B
A
G
F
APPROVEDDRAWN
AIR EDUCATION AND TRAINING COMMAND
DATEREVISION
UNITED STATES AIR FORCE
MISSISSIPPI
FACILITY NUMBER:
SHEET OF
DRAWING NUMBER:
BILOXI
RECOMMENDED:
(Chief of Engineering)
SUBMITTED:
(Chief of Contracts Design)
SCALE:
PROJECT NUMBER:
CHECKED:
DATE:
DESIGNED:
DRAWN:
OFFICE OF CIVIL ENGINEERS
KEESLER AIR FORCE
MAHG141001 6
C. STEWART
13 MAY 2021
A1.4
C. STEWART
1" = 30'-0"1 FLOOR PLAN - 7320
MAINTAIN EXTERIOR COATING
SYSTEMS
2804, 3710, 4106, 4116, 6950, 7320
ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE
APPROXIMATE. CONTRACTOR IS ENCOURAGED TO FIELD
1" = 30'-0"2 EXTERIOR ELEVATIONS 7320 - OVERALL
| Sheets |
| A1.0 - FLOOR PLAN - BUILDING 2804 |
| A1.1 - FLOOR PLAN - BUILDING 3710/4106 |
| A1.2 - FLOOR PLAN - BUILDING 4116 |
| A1.3 - FLOOR PLAN - BUILDING 6950 |
| A1.4 - FLOOR PLAN - BUILDING 7320 |
| T1.0 - TITLE SHEET |
File details come from the government source that posted it. Updated .