Attachment 3 - Exteriors Phase 3 DWG_13 May 2021.pdf

PDF 865 KB Posted

Attached to
Maintain Exterior Coatings of Multiple Facilities Federal contract opportunity
Solicitation number
FA301021R0018
Issued by
Department of the Air Force Air Education and Training Command

About this file

This solicitation is seeking proposals for maintaining exterior coatings of multiple facilities at Keesler Air Force Base. The scope of work involves removing mold, dirt, mildew and peeling paint from building exteriors and repainting. It is a 100% HUBZone set-aside with an estimated value between $250,000 to $500,000. An organized site visit will be held on July 22, 2021 for offerors to inspect the facilities. Proposals are due by the date specified in Section L, with award being made on an all or some basis depending on available funding. Option years may be exercised up to 120 days after award. Attention is directed to proposal preparation instructions in Section L and evaluation criteria in Section M. Funds are not presently available and no award will be made until funding is obtained, with the government reserving the right to cancel the solicitation.

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Deer Island

Ship IslandCat Island

St. Louis Bay

Mis siss ipp i

Sou nd

Big Lake

Back Bay of Biloxi

Bernard Bayou

W olf

R iv er

Biloxi River

Little Biloxi River

Tchoutacabouffa

River

Tuxachanie

Creek

Tch out aca bou ffa

Riv er

Cedar Lake

S a u c ie r

C re e k

Miss issip pi

Soun d

INTERSTATE 10

U .S

. H W

Y 49

U.S. HWY 90

I-1

LA

R

C H

ER

B

LV

D

GEN CHAPPIE JAMES AVE

PARADE LN

PRJOECT SITE

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE

MAINTAIN EXTERIOR COATING SYSTEMS

KEESLER AFB, MISSISSIPPI

MAY 13, 2021

MAHG141001

MAHG141001 6

C. STEWART

ABBREVIATIONS

ABA AMERICAN BARRIERS ACT

AFF ABOVE FINISH FLOOR

ACT ACOUSTICAL CEILING TILE

BD BOARD

CONC. CONCRETE

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

ELECT ELECTRIC

GWB GYPSUM WALL BOARD

GYP GYPSUM

HORZ HORIZONTAL

HVAC HEATING VENTING AIR CONDITIONING

MAX MAXIMUM

MECH MECHANICAL

MIN MINIMUM

MLWK MILLWORK

OC ON CENTER

PLAM PLASTIC LAMINATE

PLUM PLUMBING

PLYWD PLYWOOD

PNT PAINTED

PT PORCELAIN TILE

RCP REFLECTED CEILING PLAN

TYP TYPICAL

VCT VINYL COMPOSITION TILE

VNYL VINYL

VERT VERTICAL

W/ WITH

WD WOOD

INDEX OF

1 T1.0 TITLE SHEET

2 A1.0 FLOOR PLAN - BUILDING 2804

3 A1.1 FLOOR PLAN - BUILDING 3710/4106

4 A1.2 FLOOR PLAN - BUILDING 4116

5 A1.3 FLOOR PLAN - BUILDING 6950

6 A1.4 FLOOR PLAN - BUILDING 7320

13 MAY 2021

2804, 3710, 4106, 4116, 6950, 7320

T1.0

C. STEWART

MAINTAIN EXTERIOR COATING

SYSTEMS

GENERAL NOTES

1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND

START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY

CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS

DESIGNED.

2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.

CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION

MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY

FASHION.

4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY

WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO

PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR

SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.

5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND

MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.

A1.0

A1.0

A1.0 5

A1.04

- 3

1'

2"

- 1 3'

8"

- 3

1'

2"

+/- 109' - 4 3/4"

- 1

7'

6"

- 3

1'

2"

- 1 3'

8"

- 3

1'

2"

- 7

6'

0"

- 7

6'

0"

+/- 271' - 9"

+/- 5' - 11 1/2"

- 2

9'

4"

- 4

- 9

- 4

- 2

9'

4"

A

A

B A

A

A

BA

BA

B

A

B

B

B

B

A B

A B

A

A

B A

A

A

BA

BA

BA

B

A

B

B

B

B

A B

A B

+/- 148' - 3 1/4"

14' - 1"

D

D

D

D D

D

D

D

F G

F G

F G F G

F G

F G

A BA B D F G

GF

GF

- 1

2'

1"

- 1 1'

8" +/

- 2 3'

9"

- 1

8'

4"

- 1

4'

5"

- 1

4'

5"

- 1

8'

4"

A DB F G

E

- 2

3'

9"

- 1

4'

5"

- 1

1'

8"

- 1

8'

4"

- 2

3'

9"

A DB F G

E

- 1

4'

5"

- 1

8'

4"

- 1

2'

5"

- 1

1'

8" +/

- 2

3'

9"

A DB F G

- 1

2'

5"+/

- 2

3'

9"

- 1

4'

5"

- 1

8'

4"

- 1

4'

5"

- 1

8'

4"

A DB F G

BUILDING DIMENSION INFORMATION - 2804

EXTERIOR WALL SURFACE AREA (EIFS) = +/-9,388 SF

DEMO/RENOVATION KEY NOTES

A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE FROM BUILDING EXTERIOR SURFACE - ALL

WALLS, SOFFITS, OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY PRESSURE WASH.

PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE;

COLOR TO MATCH EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).

B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.) AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH COAT(S) (2 COATS); COLOR TO MATCH EXISTING.

C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS, OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY PRESSURE WASH.

PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL CMU BUILDING EXTERIOR SURFACE; COLOR

TO MATCH EXISTING.

D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING (CREAM), OR EQUAL.

E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR EQUAL. SEAL ALL

BRICK WALLS IN ACCORDANCE WITH SOW, SPECIFICAITONS, AND DRAWINGS.

F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY); COLOR TO MATCH MEDIUM BRONZE, OR

EQUAL. USE RUST INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND HOVERHANGS.

G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR. APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL

MATERIAL. PRIME AND PAINT.

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE 3/32" = 1'-0"1 FLOOR PLAN - 2804

MAHG141001 6

C. STEWART

13 MAY 2021

A1.0

C. STEWART

MAINTAIN EXTERIOR COATING

SYSTEMS

1/16" = 1'-0"2 EXTERIOR ELEVATION 2804 - SOUTH

1/16" = 1'-0"3 EXTERIOR ELEVATION 2804 - NORTH

1/16" = 1'-0"4 EXTERIOR ELEVATION 2804 - EAST

1/16" = 1'-0"5 EXTERIOR ELEVATION 2804 - WEST

2804, 3710, 4106, 4116, 6950, 7320

ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE

APPROXIMATE. CONTRACTOR IS ENCOURAGED TO FIELD

VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID

DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND

START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY

CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS

DESIGNED.

2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.

CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION

MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY

FASHION.

4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY

WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO

PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR

SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.

5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND

MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.

+/- 10' - 0"

- 1

2'

0"

A

A

A

A

C

C

C

C

A

AA

A

/4

24' - 3 1/4" 112' - 0 1/4" 24' - 3 1/2"

160' - 7"

/4

9'

/4

/4

/4

32' - 7" 103' - 8 1/4" 24' - 3 1/2"

160' - 7"

/4

B

B

A B

B

B

AB

A B

D D

D

D

D

D

D

GF

A B D GF

A B D GF

F G

F G

F G

GF

FG

FG

DEMO/RENOVATION KEY NOTES

A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH

EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).

B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)

AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT

ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN

MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH

COAT(S) (2 COATS); COLOR TO MATCH EXISTING.

C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.

D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE

NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL

CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING

(CREAM), OR EQUAL.

E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS

EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY

ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR

EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,

SPECIFICAITONS, AND DRAWINGS.

F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY);

COLOR TO MATCH MEDIUM BRONZE, OR EQUAL. USE RUST

INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND

HOVERHANGS.

G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED

DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED

METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED

AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.

APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL

MATERIAL. PRIME AND PAINT.

A G

- 2

6'

- 1

0'

7"

B D F

A GB D F

+/- 3' - 0"

- 7

" B

- 2

6'

- 1

0'

7"

A GB D F

A GB D F

A GB D F

B

- 2

6'

+/- 0' - 4" B +/- 1' - 6"

- 8

B

A

- 1

3'

4"

- 1

3'

4"

D

A GB D F

A GB D F

B

- 7

+/- 3' - 3"

B +/- 2' - 5"

- 2

A

B

- 2

6'

- 1

3'

4"

- 1

3'

4"

A GB D F A GB D F

- 1

2'

0"

A C

- 1

2'

0"A C

- 1

2'

0"A C

- 1

2'

0"A C

3709 (LARCHER CHAPEL)

LA

R

C H

ER

B

LV

D

GEN CHAPPIE JAMES AVE

BUILDING DIMENSION INFORMATION - 3710

EXTERIOR WALL SURFACE AREA (CMU) = +/-464 SQUARE FEET

BUILDING DIMENSION INFORMATION - 4106

EXTERIOR WALL SURFACE AREA (EIFS) = +/-13,004 SQUARE FEET

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE

MAHG141001 6

C. STEWART

13 MAY 2021

A1.1

C. STEWART

3/16" = 1'-0"6 FLOOR PLAN - 3710

3/32" = 1'-0"5 FLOOR PLAN - 4106

MAINTAIN EXTERIOR COATING

SYSTEMS

1/16" = 1'-0"3 EXTERIOR ELEVATION 4106 - NORTH

1/16" = 1'-0"1 EXTERIOR ELEVATION 4106 - SOUTH

1/16" = 1'-0"2 EXTERIOR ELEVATION 4106 - EAST

1/16" = 1'-0"4 EXTERIOR ELEVATION 4106 - WEST

2804, 3710, 4106, 4116, 6950, 7320

3/16" = 1'-0"7 EXTERIOR ELEVATION 3710 - EAST

3/16" = 1'-0"8 EXTERIOR ELEVATION 3710 - NORTH

3/16" = 1'-0"9 EXTERIOR ELEVATION 3710 - SOUTH 3/16" = 1'-0"10 EXTERIOR ELEVATION 3710 - WEST

1" = 200'-0"

KEY PLAN - 3710

ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE

DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND

START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY

CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS

DESIGNED.

2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.

CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION

MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY

FASHION.

4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY

WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO

PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR

SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.

5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND

MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.

DEMO/RENOVATION KEY NOTES

A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH

EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).

B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)

AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT

ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN

MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH

COAT(S) (2 COATS); COLOR TO MATCH EXISTING.

C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.

D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE

NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL

CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING

(CREAM), OR EQUAL.

E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS

EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY

ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR

EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,

SPECIFICAITONS, AND DRAWINGS.

F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY);

COLOR TO MATCH MEDIUM BRONZE, OR EQUAL. USE RUST

INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND

HOVERHANGS.

G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED

DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED

METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED

AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.

APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL

MATERIAL. PRIME AND PAINT.

A

A

8'

4"

4'

4"

302' - 0"

30' - 8"

30' - 8"

B

A B

B

AB

MAIN BUILDING ROOF

EXISTING

PENTHOUSE

ROOF

EXISTING

PENTHOUSE

ROOF

EXISTING

PENTHOUSE

ROOF

EXISTING

PENTHOUSE

ROOF

EXISTING

PENTHOUSE

ROOF

EXISTING

PENTHOUSE

ROOF

D

D

D

F G

DFG

F G

A B D F G

ABDFG

ABDFG

F

G

A B D F G

A B D F G

A B D F G

- 4

1'

8"

- 2

7'

5"

- 1 4'

3"

TOP OF MAIN BULDING ROOF

TOP OF PENTHOUSE ROOF

A GB D F

BUILDING DIMENSION INFORMATION - 4116

EXTERIOR WALL SURFACE AREA - BUILDING AND PENTHOUSES (EIFS) = +/-40,216 SF

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE

MAHG141001 6

C. STEWART

13 MAY 2021

A1.2

C. STEWART

MAINTAIN EXTERIOR COATING

SYSTEMS

3/64" = 1'-0"1 ROOF PLAN - 4116

2804, 3710, 4106, 4116, 6950, 7320

1/16" = 1'-0"2 EXTERIOR ELEVATION 4116 - TYPICAL

NOTE: THIS EXTERIOR ELEVATION IS FOR REFERENCE TO BUILDING HEIGHT ONLY. IT IS TYPICAL TO

ALL EXTERIOR SIDES OF BUILDING IN REFERENCE TO BUILDING HEIGHT

ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE

C118

RECEPTION/

BRIEFING

C117

WOMEN

C123

MEN

C128

CORR.

C120

ELECT.

C121

BOILER ROOM

C116

VENDING

C122

ELEV/ MECH

C101

LOBBY

C110

MTL HALL

C115

OFFICE

C114

OFFICE

C113

OFFICE

C112

OFFICE

C111

OFFICE

C114 C108

OFFICE

C107

OFFICE

C106

STORAGE

C104

OFFICE

C103

OFFICE

C130

STAIRS

C127

DAY ROOM

S125

LIVING UNIT

C125

LAUNDRY

S124

LIVING UNIT

W121

LIVING UNIT

W120

LIVING UNIT

W118

LIVING UNIT

W119

LIVING UNIT

C132

LIVING UNIT

C133

LIVING UNIT

C100

LOBBY

S123

LIVING UNIT

S122

LIVING UNIT

S121

LIVING UNIT

S120

LIVING UNIT

S119

LIVING UNIT

S118

LIVING UNIT

S117

LIVING UNIT

S116

LIVING UNIT

S115

LIVING UNIT

S114

LIVING UNIT

S113

LIVING UNIT

S112

LIVING UNIT

S111

LIVING UNIT

S110

LIVING UNIT

S109

LIVING UNIT

S108

LIVING UNIT

S107

LIVING UNIT

S106

LIVING UNIT

S105

LIVING UNIT

S104

LIVING UNIT

S103

LIVING UNIT

S102

LIVING UNIT

S101

ELEC

S127

VESTIBLE

S100

STAIRS

E120

LIVING UNIT

E121

LIVING UNIT

E118

LIVING UNIT

E119

LIVING UNIT

E116

LIVING UNIT

E117

LIVING UNIT

E114

LIVING UNIT

E115

LIVING UNIT

E112

LIVING UNIT

E113

LIVING UNIT

E110

LIVING UNIT

E111

LIVING UNIT

E108

LIVING UNIT

E109

LIVING UNIT

E106

LIVING UNIT

E107

LIVING UNIT

E104

LIVING UNIT

E105

LIVING UNIT

E102

LIVING UNIT

E103

LIVING UNIT

E100

STAIR

E123

VESTIBULE

E101

ELEC.

W116

LIVING UNIT

W117

LIVING UNIT

W114

LIVING UNIT

W115

LIVING UNIT

W112

LIVING UNIT

W113

LIVING UNIT

W110

LIVING UNIT

W111

LIVING UNIT

W108

LIVING UNIT

W109

LIVING UNIT

W106

LIVING UNIT

W107

LIVING UNIT

W104

LIVING UNIT

W105

LIVING UNIT

W102

LIVING UNIT

W103

LIVING UNIT

W101

ELEC.

W103

VEST.

W100

STAIRS

C114

JANITOR'

CLOSET

KEESLER HALL

NO 2

DAVIS MANOR

GENERAL NOTES

1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND

START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY

CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS

DESIGNED.

2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.

CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION

MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY

FASHION.

4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY

WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO

PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR

SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.

5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND

MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.

+/- 160' - 11"+/- 49' - 2 1/4"+/- 18' - 9 1/4"+/- 49' - 1 1/4"+/- 161' - 0"

+/- 439' - 0 1/4"

- 1

6'

8"

- 4 0'

6"

- 1

6'

4"

- 7

3'

6"

- 1

0'

0"

- 2

/4

- 2

/4

+/- 10' - 0"

+/- 180' - 11"+/- 10' - 0" +/- 180' - 10 3/4"

+/- 190' - 11" +/- 190' - 11"

A B

BAA B

A B

BA

A B

A B

A B

AB

D D

D

D

D

D

D

D

F G

F G

F G F G

AB

AB

D

D

FG

FG

F G

D F G

F

G

B A

D F

G

F G F G

DEMO/RENOVATION KEY NOTES

A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH

EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).

B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)

AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT

ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN

MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH

COAT(S) (2 COATS); COLOR TO MATCH EXISTING.

C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.

D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE

NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL

CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING

(CREAM), OR EQUAL.

E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS

EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY

ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR

EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,

SPECIFICAITONS, AND DRAWINGS.

F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY);

COLOR TO MATCH MEDIUM BRONZE, OR EQUAL. USE RUST

INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND

HOVERHANGS.

G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED

DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED

METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED

AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.

APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL

MATERIAL. PRIME AND PAINT.

- 3

4'

2"

- 1

0'

8" +/

- 3

4'

2"

- 1

0'

8"

- 2

3'

6"

- 1 0'

8" +/

- 3 4'

2"

- 2

3'

6"

- 1 0'

8" +/

- 3 4'

2"

EIFS

BRICK

EIFS

BRICK

EIFS

BRICK

EIFS

BRICK

E

E

E

E

F

F

F

F

F

F

A B D G

A B D G

A B D G

A B D G

BUILDING DIMENSION INFORMATION - 6950

EXTERIOR WALL SURFACE AREA (EIFS) = +/-33,986 SF

EXTERIOR WALL SURFACE AREA (BRICK) = +/-15,819 SF

EXTERIOR WALL SURFACE (TOTAL) = +/-49,805 SF

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE

MAHG141001 6

C. STEWART

13 MAY 2021

A1.3

C. STEWART

1" = 30'-0"1 FLOOR PLAN - 6950

MAINTAIN EXTERIOR COATING

SYSTEMS

2804, 3710, 4106, 4116, 6950, 7320

1/32" = 1'-0"2 EXTERIOR ELEVATIONS 6950 - OVERALL

ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE

C118

RECEPTION/

BRIEFING

C117

WOMEN

C123

MEN

C128

CORR.

C120

ELECT.

C121

BOILER ROOM

C116

VENDING

C122

ELEV/ MECH

C101

LOBBY

C110

MTL HALL

C115

OFFICE

C114

OFFICE

C113

OFFICE

C112

OFFICE

C111

OFFICE

C109 C108

OFFICE

C107

OFFICE

C106

STORAGE

C104

OFFICE

C103

OFFICE

C130

STAIRS

C127

DAY ROOM

S125

LIVING UNIT

C125

LAUNDRY

S124

LIVING UNIT

C132

LIVING UNIT

C133

LIVING UNIT

C100

LOBBY

S123

LIVING UNIT

S122

LIVING UNIT

S121

LIVING UNIT

S120

LIVING UNIT

S119

LIVING UNIT

S118

LIVING UNIT

S117

LIVING UNIT

S116

LIVING UNIT

S115

LIVING UNIT

S114

LIVING UNIT

S113

LIVING UNIT

S112

LIVING UNIT

S111

LIVING UNIT

S110

LIVING UNIT

S109

LIVING UNIT

S108

LIVING UNIT

S107

LIVING UNIT

S106

LIVING UNIT

S105

LIVING UNIT

S104

LIVING UNIT

S103

LIVING UNIT

S102

LIVING UNIT

S101

ELEC

S127

VESTIBLE

S100

STAIRS

E116

LIVING UNIT

E117

LIVING UNIT

E114

LIVING UNIT

E115

LIVING UNIT

E112

LIVING UNIT

E113

LIVING UNIT

E110

LIVING UNIT

E111

LIVING UNIT

E108

LIVING UNIT

E109

LIVING UNIT

E106

LIVING UNIT

E107

LIVING UNIT

E104

LIVING UNIT

E105

LIVING UNIT

E102

LIVING UNIT

E103

LIVING UNIT

E100

STAIR

E123

VESTIBULE

E101

ELEC.

W116

LIVING UNIT

W117

LIVING UNIT

W114

LIVING UNIT

W115

LIVING UNIT

W112

LIVING UNIT

W113

LIVING UNIT

W110

LIVING UNIT

W111

LIVING UNIT

W108

LIVING UNIT

W109

LIVING UNIT

W106

LIVING UNIT

W107

LIVING UNIT

W104

LIVING UNIT

W105

LIVING UNIT

W102

LIVING UNIT

W103

LIVING UNIT

W101

ELEC.

W103

VEST.

W100

STAIRS

C131

JANITOR'

CLOSET

KEESLER HALL

NO 2

CONNER MANOR

+/- 131' - 1"+/- 49' - 2 1/4"+/- 18' - 9 1/4"+/- 49' - 1 1/4"+/- 131' - 2"

+/- 379' - 4"

- 1

6'

8"

- 4 0'

6"

- 5

7'

2"

+/- 151' - 0 3/4"+/- 10' - 0" +/- 151' - 0 3/4" +/- 10' - 0"

+/- 161' - 0 3/4" +/- 161' - 1"

- 1

0'

0"

- 2

- 2

- 1

6'

8"

- 4 0'

6"

- 5

7'

2"

A B AB

A B AB

AB

AB

+/- 40' - 6" +/- 16' - 8 1/4"

+/- 57' - 2 1/4"

A B

AB

A B

AB A B

A B

D D

D

D

D

D D

D

D

D

D

F G F G

F G

FG

F G

F G F G

F G

F GF G

F G

DEMO/RENOVATION KEY NOTES

A. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

STUCCO/EIFS BUILDING EXTERIOR SURFACE; COLOR TO MATCH

EXISTING (DO NOT PAINT BRICK, ONLY CLEAN BRICK).

B. REPAIR DAMAGE TO WALL SURFACE (CHIPS, CRACKS, VOIDS, ETC.)

AS REQUIRED. MATCH SURROUNDING FINISH AND COLOR. PAINT

ALL STUCCO/EIFS BUILDING EXTERIOR SURFACE USING "BENJAMIN

MOORE BLOCK SEAL, OR EQUAL, AS PRIMER (1 COAT) AND FINISH

COAT(S) (2 COATS); COLOR TO MATCH EXISTING.

C. REMOVE MOLD, DIRT, MILDEW,DUST, PEELING PAINT, AND/OR ALGAE

FROM BUILDING EXTERIOR SURFACE - ALL WALLS, SOFFITS,

OVERHANG CEILINGS, DOORS, AND WINDOWS. (NOTE: WATER ONLY

PRESSURE WASH. PRESSURE WASH EXTERIOR SURFACE WITH

WATER ONLY. USE CARE TO PREVENT DAMAGE, OR FURTHER

DAMAGE FROM OCCURING TO EXTERIOR SURFACES.) PAINT ALL

CMU BUILDING EXTERIOR SURFACE; COLOR TO MATCH EXISTING.

D. PRIOR TO PRESSURE WASHING, REPAIR JOINT SEALANT WHERE

NEEDED. USE COLOR-MATCHED EXTERIOR SEALANT TO SEAL

CRACKS AND CHIPS, AS NEEDED; COLOR TO MATCH EXISTING

(CREAM), OR EQUAL.

E. REPAIR CRACKS IN BRICK AND/OR MORTAR JOINTS WHERE CRACKS

EXCEED 1/64" IN OPENING SIZE USING ULTRA SPEC MASONRY

ELASTOMERIC WATERPROOFING COATING, LOW LUSTER (360), OR

EQUAL. SEAL ALL BRICK WALLS IN ACCORDANCE WITH SOW,

SPECIFICAITONS, AND DRAWINGS.

F. PAINT EXTERIOR DOORS, FRAMES, AND LOUVERS (STEEL ONLY);

COLOR TO MATCH MEDIUM BRONZE, OR EQUAL. USE RUST

INHIBITOR PRIMER ON METALDOORS, FRAMES, LOUVERS, AND

HOVERHANGS.

G. REPAIR SPALLED AND CRACKED STUCCO SOFFIT. REMOVED

DAMAGED CONCRETE AT SPALLED AREAS AND CLEAN EXPOSED

METAL OF RUST. APPLY A BONDING AGENT TO THE AFFECTED

AREAS AND PATCH USING A POLYMER MODIFIED CEMENT MORTAR.

APPLY SCRATCH AND FINISH COAT, FULLY ENCASING THE METAL

MATERIAL. PRIME AND PAINT.

GENERAL NOTES

1. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DRAWINGS/DETAILS MAY VARY. CONTRACTOR IS ENCOURAGED TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND

START OF CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY

CONDITIONS DETRIMENTAL TO THE COMPLETION OF THE WORK AS

DESIGNED.

2. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

3. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL.

CONTRACTOR IS NOT ALLOWED TO STOCKPILE DEMOLITION

MATERIALS ON SITE; ALL MATERIALS TO BE REMOVED IN A TIMELY

FASHION.

4. CONTRACTOR IS ENCOURAGED TO COORDINATE WORK DURING DRY

WEATHER DAYS. CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO

PREVENT DAMAGE DUE TO INCLEMENT WEATHER. CONTRACTOR

SHALL SECURE WORK BEFORE LEAVING THE JOB SITE FOR THE DAY.

5. CONTRACTOR IS ENCOURAGED TO VERIFY SITE CONDITIONS AND

MEASUREMENTS FOR PROPER FIT, PRIOR TO ORDERING MATERIALS.

- 1

0'

8"

- 2 3'

6"

- 3

4'

2"

- 1

0'

8"

- 2 3'

6"

- 3

4'

2"

- 1

0'

8"

- 2 3'

6"

- 3

4'

2"

- 1

0'

8"

- 2 3'

6"

- 3

4'

2"

EIFS

BRICK

EIFS

BRICK

EIFS

BRICK

EIFS

BRICK

E

E

E

E

F

F

F

F

F

F

A B D G

A B D G

A B D G

A B D G

F

F

BUILDING DIMENSION INFORMATION - 7320

EXTERIOR WALL SURFACE AREA (EIFS) = +/-34,513 SF

EXTERIOR WALL SURFACE AREA (BRICK) = +/-16,064 SF

EXTERIOR WALL SURFACE (TOTAL) = +/-50,577 SF

G. REED

A. MARASCA G. REED

VARIES

C. STEWART

876543

D

E

B

C

A

87654321

G

F

E

D

C

B

A

G

F

APPROVEDDRAWN

AIR EDUCATION AND TRAINING COMMAND

DATEREVISION

UNITED STATES AIR FORCE

MISSISSIPPI

FACILITY NUMBER:

SHEET OF

DRAWING NUMBER:

BILOXI

RECOMMENDED:

(Chief of Engineering)

SUBMITTED:

(Chief of Contracts Design)

SCALE:

PROJECT NUMBER:

CHECKED:

DATE:

DESIGNED:

DRAWN:

OFFICE OF CIVIL ENGINEERS

KEESLER AIR FORCE

MAHG141001 6

C. STEWART

13 MAY 2021

A1.4

C. STEWART

1" = 30'-0"1 FLOOR PLAN - 7320

MAINTAIN EXTERIOR COATING

SYSTEMS

2804, 3710, 4106, 4116, 6950, 7320

ALL DIMENSIONS/SQUARE FOOTAGE/LINEAR FOOTAGE ARE

APPROXIMATE. CONTRACTOR IS ENCOURAGED TO FIELD

1" = 30'-0"2 EXTERIOR ELEVATIONS 7320 - OVERALL

Sheets
A1.0 - FLOOR PLAN - BUILDING 2804
A1.1 - FLOOR PLAN - BUILDING 3710/4106
A1.2 - FLOOR PLAN - BUILDING 4116
A1.3 - FLOOR PLAN - BUILDING 6950
A1.4 - FLOOR PLAN - BUILDING 7320
T1.0 - TITLE SHEET

File details come from the government source that posted it. Updated .