ADDENDUM #1 Date: June 23, 2020
PROJECT NAME: REPAIR RESTROOMS B4002
LOCATION: Building 4002 – Keesler AFB, Mississippi
PROJECT NUMBER: MAHG14-1068, WO #67136
The following changes apply:
For the men’s room hand dryers: Fur-out wall 1” and hang 5/8” moisture resistant gypsum sheathing.
Run new conduit inside furring for hand dryers. All other new power requirements to use existing chase walls. Punch through block as needed.
Replace existing Receptacles with GFCI Receptacles. The panel is adjacent to the male restroom.
Utilize 20 Amp breakers for each hand dryer, #12 GA copper wire. The panel in adjacent to the male restroom.
Delete requirement for wall mounted occupant sensors at the existing switch. Reuse existing switch.
Add ceiling mounted Dual IR for lighting circuit. Place in restroom ceiling for best detection of occupancy.
Delete requirement for Tank Type toilets. All toilets to be flush valve type.
DELETE REQUIRMENT: SECTION 01 73 20, 3.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS, para B. part 2. If services/systems are required to be removed, relocated, or abandoned, provide temporary services/systems that bypass area of selective demolition and that maintain continuity of services/systems to other parts of building.
Do not provide Temporary Services, Admin department will utilize warehouse restrooms until project completion.
END OF ADDENDUM 1