Attachment J1 Niagara Falls Sewer.doc

DOC document 301 KB Posted

Attached to
Air Force Utility Privatization Effort for Niagara Falls ARS Wastewater Distribution System
Solicitation number
FA3002-09-R-0002
Issued by

About this file

Attachment J1 Inventory

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

rfp template

May 2008 air force utilities privatization rfp template May 2008 air force utilities privatization attachment j1 Niagara Falls ARS Wastewater System

1J1.1 Niagara Falls ARS Overview J1- J1.2 Wastewater System Description J1-1 J4.2.1 Wastewater System Fixed Equipment Inventory J1-1 J4.2.2 Wastewater System Non-Fixed Equipment and Specialized Tools J1-9 J4.2.3 Wastewater System Manuals, Drawings, and Records J1-10 J1.3 Specific Service Requirements J1-10 J1.4 Current Service Arrangement J1-11 J1.5 Secondary Metering J1-11 J1.5.1 Existing Secondary Meters J1-11 J1.5.2 Required New Secondary Meters J1-11 J1.6 Monthly Submittals J1-12 J1.7 Infiltration and Inflow (I&I) Projects J1-12 J1.8 Service Area J1-12 J1.9 Off-Installation Sites J1-13 J1.10 Specific Transition Requirements J1-13 J1.11 Initial System Deficiency Corrections (ISDC) J1-13 Exhibits J1-15 Exhibit A—Map of Premises J1-15 Exhibit B—Description of Premises J1-16 B.1. General Description of the Utility System, Lateral Extent of the Right-of-Access, and Points of Demarcation:

J1-16 B.2. Description of Restricted Access Areas:

J1-19 Exhibit C—Environmental Baseline Survey J1-20

Tables 1 - Fixed Inventory J1-3 2 - Spare Parts J1-9 3 - Specialized Vehicles and Tools J1-9 4 - Manuals, Drawings, and Records J1-10 5 - Existing Secondary Meters J1-11 6 - New Secondary Meters J1-11 7 - Service Connections and Disconnections J1-13 8 - System Deficiencies J1-13 9 - General Points of Demarcation J1-16 10 - Unique Points of Demarcation J1-18 11 - Restricted Access Areas J1-19

J1 Niagara Falls ARS Wastewater System

J1.1 Niagara Falls ARS Overview

The Niagara Falls Air Reserve Station (ARS) is home to the 914th Airlift Wing (AW) of the Air Force Reserve and the 107th Airlift Wing (AW) of the New York Air National Guard. The 914th AW is the host unit at the Niagara Falls ARS and the 107th AW is the largest tenant. The installation is located approximately 6 miles east of Niagara Falls, New York and 20 miles north of Buffalo, New York. The installation occupies 985 acres on the north side part of the Niagara Falls International Airport in Niagara County, New York. The installation leases 38.71 acres from the People of the State of New York and 37.1 acres from the Niagara Frontier Transportation Authority.

The 914th AW has an economic impact of over $91 million on the surrounding area. The working population consists of 1,245 military and 501 civilian personnel. The 914th AW’s mission is to provide air, land, and aerial delivery of troops, supplies, and equipment using C-130 H-3 Hercules cargo aircraft carriers. The base occupies 82 buildings on the Niagara Falls ARS including 62 buildings dedicated to industrial activities and 20 to administrative activities.

The 107th AW has an economic impact of over $49 million on the surrounding area. The working population consists of 585 military personnel, and 215 civilians. The 107th occupies 22 buildings on the Niagara Falls ARS including 16 buildings dedicated to industrial activities and 6 to administrative activities.

The 107th AW’s mission recently changed to become directly connected to that of the 914th. The 107th now works alongside the Air Force Reserve's 914th Airlift Wing as part of the Air Force Reserve's "Associate" concept. In an associate base, units share people, resources and processes to accomplish their flying missions. "Team Niagara" features the 914th as host to the 107th with both units flying reserve C-130 H2s.

The Niagara Falls International Airport opened in 1928 and was joined by the military in 1946. The base has expanded several times over the years. The base has some Visiting Officer Quarters but no permanent on-base military family housing. A 25,000-square foot expansion on the Armed Forces Reserve Center (AFRC) is currently under construction.

J1.2 Wastewater System Description

J1.2.1 Wastewater System Fixed Equipment Inventory

The wastewater collection system consists of all appurtenances physically connected to the collection system from the point of demarcation defined by the right of access. The system may include pipelines, manholes, lift stations, valves, controls, and meters. The actual inventory of items sold will be in the bill of sale at the time the system is transferred. The following description and inventory is included to provide the Contractor with a general understanding of the size and configuration of the system. The Government makes no representation that the inventory is accurate. The Contractor shall base its proposal on site inspections, information in the technical library, other pertinent information, and to a lesser degree the following description and inventory.

Specifically excluded from the wastewater collection system privatization are:

· Ground water extraction systems from NFARS IRP sites that pump water to the collection system.

· Abandoned lines.

· Oil/water separators and grease traps

· Stormwater diversion pump station located in the Airfield Apron of the 107th AW.

J1.2.1.1 Description

Wastewater generated by the Niagara Falls ARS discharges to the Niagara County Sewer District No. 1 (NCSD) sanitary sewer collection system at two locations. Wastewater from the main lift station discharges through a force main to a NCSD manhole in Walmore Road on the east side of the installation. Wastewater from the Fire Training Area discharges to a NCSD lateral immediately north of the fire training area and south of Lockport Road at the northwest side of the installation.

The Niagara Falls ARS wastewater collection system consists of gravity-flow and force main pipes. The installation has three lift stations that will be privatized and a stormwater diversion pump station that is excluded. The stormwater diversion pump station collects de-icing fluid from the airplane parking apron of the 107th AW and discharges into the installation’s collection system. This pump station is not part of the privatization process. Ownership of the line will start where the collection system connects to the pump station discharge line.

The lift station located at Building 822 collects wastewater from the 107th AW and the north side of the 914th AW. A force main conveys water from Building 822 to the main lift station which is located in Building 731. Pumps in Building 731 discharge waste water to the NCSD No. 1 manhole in Walmore Road east of the site. Air Force owned meters are located in a manhole near Building 822 and in Building 731 and are used for measuring the quantity of wastewater discharged from each building. The meter in Building 731, is used to measure discharge quantities for invoicing from the installation. The third lift station is located at the Fire Training Area. It collects water from the Fire Training Area and discharges to a NCSD No. 1 owned lateral that extends from the Air Force property line north to Lockport Road.

Two intermediate wastewater flow meters were installed in existing system manholes near buildings 850 and B 206. These meters were installed as part of a study to document infiltration flows through these lines. Both meters will be privatized.

The Niagara Falls ARS collection lines consist of PVC and cast iron laterals, oil/water separators, and PVC and vitrified clay pipe collector mains. The oil/water separators are not included in the privatization contract. The vitrified clay pipe and cast iron piping is located on the 914th AW side of the installation. The wastewater collection lines located on the 107th AW side of the base are PVC pipe and were installed and marked with tracer wire in the mid 1990’s. At this time, tracer wire and marker tape are intermittent along all pipes on base. There also is no cathodic protection installed on this system. Burial depths for sewer lines on the Niagara Falls ARS range from approximately 6 to 14 feet below ground surface, although the actual depth may vary. An approximate 5 percent of the wastewater piping was estimated to be beneath paved surfaces.

The wastewater collection system beneath the 107th AW property consists mostly of newer PVC pipe and is in good shape. The older parts of the system on the 914th AW side of the installation are expected to be near the end of their useful life. The collection system at the 914th AW experiences significant amounts of infiltration due to stormwater infiltration into the sanitary system. A video inspection from 1999 showed a few areas of cracked and sagging pipe at the 914th AW. Five phases of renewal and replacement projects have been planned to correct deficiencies described in &I reports. One of the phases has been completed. The remaining phases are described in Table 8.

The 914th AW discharges wastewater under an industrial waste permit with the NCSD No. 1. The Air Force retains this permit and will be responsible for renewals or modifications to this permit.

J1.2.1.2 Inventory

Table 1 provides a general listing of the major wastewater system fixed assets for the Niagara Falls ARS wastewater system included in the sale.

Table 1

Fixed Inventory

Wastewater Utility System Niagara Falls ARS

Item
Size
Quant.
Unit
Construction
Pipe, PVC FM
2
270
LF
1985
Pipe, PVC
10
104
LF
2002
Pipe, PVC
8
272
LF
1990
Pipe, VCP
8
491
LF
1988
Pipe, VCP
6
59
LF
1988
Pipe, PVC
8
301
LF
1985
Pipe, VCP
10
113
LF
1982
Pipe, VCP
6
113
LF
1982
Pipe, VCP
4
76
LF
1982
Pipe, PVC
10
1,418
LF
1980
Pipe, PVC
8
464
LF
1980
Pipe, PVC
6
113
LF
1980
Pipe, VCP
6
203
LF
1979
Pipe, VCP
3
185
LF
1979
Pipe, DI
6
109
LF
1966
Pipe, DI
4
112
LF
1966
Pipe, PVC
6
241
LF
1963
Pipe, DI
8
138
LF
1963
Pipe, CI
3
187
LF
1985
Pipe, VCP
4
111
LF
1957
Pipe, VCP
8
237
LF
1955
Pipe, VCP
6
150
LF
1955
Pipe, VCP
10
564
LF
1953
Pipe, VCP
10
149
LF
1953
Pipe, VCP
6
303
LF
1953
Pipe, VCP
4
75
LF
1953
Manhole, Brick
4 x 8
1
EA
1988
Manhole, Brick
4 x 6
1
EA
1953
Manhole, Brick
4 x 8
1
EA
1988
Manhole, Brick
4 x 8
1
EA
1981
Manhole, Brick
4 x 8
2
EA
1953
Manhole, Brick
4 x 12
1
EA
1953
Manhole, Brick
4 x 12
2
EA
1953
Manhole, Brick
4 x 8
3
EA
1953
Manhole, Concrete
4 x 6
4
EA
1985
Manhole, Concrete
4 x 8
1
EA
1985
Manhole, Concrete
5 x 8
1
EA
1985
Manhole, Concrete
4 x 6
2
EA
1994
Manhole, Concrete
4 x 12
2
EA
1995

2: NE of MH U2 & PWs

Pipe, PVC
10
350
LF
1994
Pipe, PVC
8
516
LF
1994
Pipe, VCP
10
705
LF
1984
Pipe, VCP
8
362
LF
1953
Pipe, VCP
6
254
LF
1953
Manhole, Brick
4 x 6
2
EA
1953
Manhole, Brick
4 x 8
2
EA
1953
Manhole, Concrete
4 x 6
2
EA
1994

3: MH M1 to P3 and Force Main

Pipe, PVC FM, Sch. 40
6
2,219
LF
1997
Pipe, PVC FM (SE from LS731)
8
2,008
LF
1995
Pipe, PVC
12
438
LF
1998
Pipe, PVC
8
220
LF
1998
Pipe, PVC
3
22
LF
1998
Pipe, PVC
10
401
LF
1995
Pipe, VCP
6
208
LF
1982
Pipe, VCP
10
466
LF
1955
Pipe, Asbestos-Cement
6
94
LF
1955
Pipe, VCP
6
167
LF
1953
Pipe, VCP
6
327
LF
1955
Pipe, Concrete Encasement
12
194
LF
1995
Manhole, Concrete, Bituminous Coated
4 x 12
1
EA
1996
Manhole, Concrete
4 x 6
2
EA
1995
Manhole, Concrete
4 x 6
1
EA
1994
Manhole, Concrete
4 x 8
2
EA
1982
Manhole, Brick
4 x 6
1
EA
1955
Manhole, Brick
4 x 8
1
EA
1955
Manhole, Brick
4 x 6
1
EA
1955

4: Main Gate to MH M1

Pipe, PVC
8
52
LF
2006
Pipe, PVC
6
29
LF
2006
Pipe, PVC
6
74
LF
1999
Pipe, PVC
6
478
LF
1997
Pipe, PVC
8
200
LF
1996
Pipe, PVC
6
50
LF
1996
Pipe, VCP, grouted
8
100
LF
1995
Pipe, PVC
10
179
LF
1994
Pipe, PVC
4
55
LF
1990
Pipe, PVC
8
1,216
LF
1985
Pipe, PVC
6
173
LF
1985
Pipe, PVC
3
74
LF
1985
Pipe, DI
6
160
LF
1985
Pipe, VCP
10
598
LF
1983
Pipe, PVC
4
330
LF
1983
Pipe, VCP
6
182
LF
1959
Pipe, VCP
8
678
LF
1958
Pipe, VCP
6
105
LF
1958
Pipe, VCP
6
233
LF
1956
Pipe, CI
4
58
LF
1956
Pipe, VCP
10
451
LF
1955
Pipe, VCP
8
203
LF
1955
Manhole, Brick
4 x 6
2
EA
1958
Manhole, Concrete
4 x 8
2
EA
1985
Manhole, Concrete
4 x 6
2
EA
1985
Manhole, Brick
4 x 8
5
EA
1985
Manhole, Brick
4 x 6
2
EA
1955
Manhole, Brick
4 x 8
2
EA
1955
Manhole, Brick
4 x 6
2
EA
1958

5: E of MH M1 to ANG

Pipe, PVC
6
65
LF
2001
Pipe, PVC
10
1,283
LF
1997
Pipe, PVC
8
114
LF
1997
Pipe, PVC
6
275
LF
1997
Pipe, PVC
4
60
LF
1995
Pipe, PVC
6
315
LF
1990
Pipe, PVC
6
300
LF
1986
Pipe, PVC
4
46
LF
1986
Pipe, PVC
10
741
LF
1985
Pipe, PVC
8
225
LF
1985
Pipe, PVC
6
171
LF
1985
Pipe, CI
4
25
LF
1985
Pipe, VCP
6
322
LF
1962
Pipe, VCP
8
1,156
LF
1960
Pipe, VCP
6
23
LF
1956
Pipe, Steel Encasement
20
182
LF
1997
Manhole, Concrete
4 x 12
1
EA
1990
Manhole, Brick
4 x 6
1
EA
1960
Manhole, Brick
4 x 8
1
EA
1960
Manhole, Concrete
4 x 12
3
EA
1997
Manhole, Concrete, Bituminous Coated
4 x 8
2
EA
1996
Manhole, Concrete, Bituminous Coated
4 x 12
2
EA
1996
Manhole, Square, Concrete
2'sq x 4
1
EA
1996
Manhole, Concrete
4 x 8
1
EA
1991
Manhole, Concrete
4 x 6
1
EA
1990
Manhole, Concrete
4 x 12
1
EA
1990
Manhole, Brick
4 x 8
2
EA
1960

Flow Meters

2
EA
2003
Holding Tank
500
1
EA
1953
Holding Tank
1,000
3
EA
1957

Lift Station 822

Wet Well
Lrg
1
EA
1955
Lift Station Building
Lrg
1
EA
1955
Lift Station Piping, Pumps & Controls
Lrg
1
EA
1993

Flow Meter at 822

1
EA
1993

Lift Station 731

Wet Well
Lrg
1
EA
1990
Lift Station Building
Lrg
1
EA
1990
Lift Station Piping, Pumps & Controls
Lrg
1
EA
1990

Flow Meter at 731

1
EA
1990
Pipe, PVC
10
495
LF
1996
Pipe, PVC
8
1,310
LF
1996
Pipe, PVC
6
607
LF
1996
Manhole, Concrete
4 x 6
5
EA
1996
Manhole, Concrete
4 x 8
3
EA
1996
Manhole, Brick
4 x 8
1
EA
1960
Pipe, PVC
4
286
LF
2002
Pipe, HDPE
12
831
LF
1996
Pipe, HDPE
10
1,192
LF
1996
Pipe, PVC
10
1,627
LF
1996
Pipe, PVC
8
1,696
LF
1996
Pipe, PE Lined VCP
7
651
LF
1996
Pipe, PVC
6
303
LF
1996
Pipe, PVC
4
96
LF
1996
Pipe, HDPE
4
35
LF
1996
Pipe, PVC
8
212
LF
1994
Pipe, PVC
6
52
LF
1994
Pipe, PVC
8
1,114
LF
1989
Pipe, PVC
4
52
LF
1989
Pipe, PVC
6
40
LF
1985
Pipe, VCP
6
65
LF
1965
Pipe, VCP
6
25
LF
1963
Pipe, VCP
6
261
LF
1960
Pipe, Corrugated Steel
12
223
LF
1996
Pipe, Concrete Encasement
20
63
LF
1996
Manhole, Concrete
4 x 6
1
EA
1996
Manhole, Concrete, Lined
4 x 8
2
EA
1996
Manhole, Brick, Lined
4 x 8
1
EA
1996
Manhole, Concrete, Bituminous Coated
4 x 8
1
EA
1996
Manhole, Concrete
4 x 6
5
EA
1996
Manhole, Concrete
4 x 8
2
EA
1996
Manhole, Brick, Lined
4 x 8
3
EA
1996
Manhole, Concrete, Bituminous Coated
4 x 6
5
EA
1996
Manhole, Concrete, Bituminous Coated
4 x 8
1
EA
1996
Manhole, Concrete, Bituminous Coated
4 x 12
2
EA
1996
Manhole, Brick, Lined
4 x 8
1
EA
1991
Manhole, Concrete
4 x 6
1
EA
1989
Manhole, Concrete
4 x 8
1
EA
1989
Manhole, Brick
4 x 8
2
EA
1965
Manhole, Brick
4 x 8
1
EA
1963

Pump, Fire Training Area

4
EA
1998

Wet Well

2
EA
1998
Pipe, DI
4
40
LF
1998
Pipe, DI
6
40
LF
1998

Notes:

LF = Linear Feet

EA = Each

DI = Ductile Iron

Lrg = large

PVC = Poly Vinyl Chloride

CI = Cast Iron

VCP = Vitrified Clay Pipe

J1.2.2 Wastewater System Non-Fixed Equipment and Specialized Tools

Table 2 lists other ancillary equipment (spare parts) and Table 3 lists specialized vehicles and tools included in the purchase. Offerors shall field verify all equipment, vehicles, and tools prior to submitting a bid. Offerors shall make their own determination of the adequacy of all equipment, vehicles, and tools.

Table 2

Spare Parts

Wastewater System Niagara Falls ARS

Qty
Item
Make/Model
Description
Remarks

There are no spare parts to transfer with the bill of sale.

Table 3

Specialized Vehicles and Tools

Wastewater System Niagara Falls ARS

Description
Quantity
Location
Maker

No special vehicles or tools will be transferred with the bill of sale.

J1.2.3 Wastewater System Manuals, Drawings, and Records

Table 4 lists the manuals, drawings, and records that will be transferred with the system.

Table 4

Manuals, Drawings, and Records

Wastewater System Niagara Falls ARS

Qty
Item
Description
Remarks
1
Video and Report on condition of wastewater collection system on 914th and 107th side of installation
An air force team from Randolph AFB visited the site during the fall of 1999. They used a camera and videotape to inspect and show the condition of the collection system on the 914th side of installation.
1
Design drawings from wastewater collection system for 107th side of base
These drawings were produced for the recent system upgrade on the 107th side of the installation
Drawings available in AutoCAD
1
Set of design drawings from wastewater collection system for 914th side of base
Various drawings exist from work done on this system over the years. Includes utility system site plan layout map.
Drawings available in AutoCAD
Manuals
Equipment manuals available will be provided in the technical library.

J1.3 Specific Service Requirements

The service requirements for the Niagara Falls ARS wastewater collection system are as defined in the Section C, Description/Specifications/Work Statement. The following requirements are specific to the Niagara Falls ARS wastewater collection system and are in addition to those found in Section C. If there is a conflict between requirements described below and Section C, the requirements below take precedence.

· Repairs and replacements occurring on Niagara Frontier Transportation Authority (NFTA) property must be in accordance with restrictions set forth in easement agreements. Upon notice of award, the Contractor shall apply to the NFTA for an easement to allow access to the wastewater pipe crossing NFTA property. The process of transferring ownership of the wastewater collection system cannot be completed until the easements are finalized.

J1.4 Current Service Arrangement

The NCSD No. 1 treats the Niagara Falls ARS wastewater. The sewer discharge is billed based on the meter reading from the Building 731 discharge. The FY 2007 annual usage was 56,213 kgal. The average monthly discharge was 4,680 kgal. Peak discharge occurred in the second quarter with 19,200 kgal, and the minimum quarterly discharge was 8,000 kgal in the fourth quarter.

The 914th AW discharges wastewater under an industrial waste permit with the NCSD No. 1. This permit is not transferable, the Air Force will retain responsibility for the permit.

J1.5 Secondary Metering

J1.5.1 Existing Secondary Meters

Table 5 provides a listing of the existing (at the time of contract award) secondary meters that will be transferred to the Contractor. The Contractor shall provide meter readings for all secondary meters IAW Paragraph C.3 and J4.6 below.

Table 5

Existing Secondary Meters

Wastewater Collection System Niagara Falls ARS

Meter Location
Meter Description (Type)
Manhole near Building 850
Secondary meter connected to pipe in the manhole.
Building 731
This meter is connected to the discharge line from the pump station. Even though this meter is the main meter for the installation, it will be privatized with the system.
Building 822
Secondary meter connected to pipe in the manhole.
Near Building 206
Secondary meter connected to pipe in the manhole

J1.5.2 Required New Secondary Meters

The Contractor shall install and calibrate new secondary meters as listed in Table 6. New secondary meters shall be installed IAW Paragraph C.13, Transition Plan. After installation, the Contractor shall maintain and read these meters IAW Paragraphs C.3 and J2.6 below.

Table 6

New Secondary Meters

Wastewater Collection System Niagara Falls ARS

Meter Location
Meter Description

None.

J1.6 Monthly Submittals

The Contractor shall provide the Government monthly submittals for the following:

1. Outage Report. The Contractor’s monthly outage report (blockage and overflow information) will be prepared in the format proposed by the Contractor and accepted by the Contracting Officer. Outage reports shall be submitted by the 25th of each month for the previous month. Outage reports shall be submitted to:

Name:

914th AW/CEC

Address:

2405 Franklin Drive, Niagara Falls, New York 14304-5063 Phone number:

(716) 236-3117

2. Infiltration and Inflow Report. If required by Paragraph C.3, the Contractor shall submit an Infiltration and Inflow report in a format proposed by the Contractor and accepted by the Contracting Officer. System efficiency reports shall be submitted by the 25th of each month for the previous month. System efficiency reports shall be submitted to:

Name:

914th AW/CEC

Address:

2405 Franklin Drive, Niagara Falls, New York 14304-5063 Phone number:

(716) 236-3117

J1.7 Infiltration and Inflow (I&I) Projects

IAW Paragraph C.3, Utility Service Requirement, I&I projects have been implemented by the Government for managing and monitoring I&I. Currently there are no active I&I projects. However, the previous studies showed that infiltration of groundwater is occurring. Information from the previous studies is provided in the technical library and will be turned over to the successful bidder.

J1.8 Service Area

IAW Paragraph C.4, Service Area, the service area is defined as all areas within the Niagara Falls ARS boundaries and areas covered under the Niagara Frontier Transportation Authority easement.

J1.9 Off-Installation Sites

There are no off-installation sites included in the sale of the wastewater collection system at the Niagara Falls Air Reserve Station.

J1.10 Specific Transition Requirements

IAW Paragraph C.13, Transition Plan, Table 7 provides a listing of service connections and disconnections required upon transfer.

Table 7

Service Connections and Disconnections

Wastewater System, Niagara Falls ARS

Location
Description
None
The government does not require new connections or disconnections during the transition period.

J1.11 Initial System Deficiency Corrections (ISDC)

Table 8 provides a listing of ISDC projects the Government has planned for this system. The Government recognizes these projects represent current deficiencies associated with the system. If the system is sold, the Government will not accomplish these projects. The Contractor shall determine the actual need and timing of any and all such projects. ISDC projects shall be proposed in Section B.7.4, Schedule 3 of the RFP.

Table 8

System Deficiencies Wastewater System Niagara Falls ARS

Project Location
Project Description
Repair Sanitary Sewer, Phase 1 of 5
Phase 1 of 5: Replace estimated 1589 LF of 4” to 10” Vitrified Clay Pipe. Remove and replace 3 brick manholes; repair 1 brick manhole and abandon 1 manhole. Abandon 7 sanitary sewer line segments (total of 1092 LF) that are no longer in use. Sanitary sewer lines and brick manholes have aged beyond their useful life, require continual maintenance, and contribute unacceptable levels of infiltration to the sanitary sewer system. Corrective action is to clean, repair, and/or replace existing pipe with PVC, and brick manholes with pre-cast concrete manholes. Manholes repaired prior to 1995 are estimated to require additional repairs such as grouting and manhole cover replacements. Abandoned lines are to be plugged and capped at the influent manholes. Excavation, trenching, and pavements demolition and restoration are estimated as required. Roughly 20% of the wastewater collection system base-wide (vitrified clay, cast iron, and transite pipe installed 1952-1962) are past their useful life. Base reports significant sewer maintenance problems with older pipe and brick manholes due to deterioration including extensive infiltration, and pipe separation at joints. Restoring these lines and abandoning lines no longer in use will extend the system life by at least 10 to 25 years and significantly reduce infiltration.
Repair Sanitary Sewer, Phase 3 of 5
Phase 3 of 5: (Note Phase 2 of 5 is complete). Replace estimated 588 LF of 6” and 10” Vitrified Clay Pipe and 6” Transite Pipe. Remove and replace 1 brick manhole; repair 1 brick manhole. Abandon 7 sanitary sewer line segments (total of 1007 LF) that are no longer in use. Sanitary sewer lines and brick manholes have aged beyond their useful life, require continual maintenance, and contribute unacceptable levels of infiltration to the sanitary sewer system. Corrective action is to clean, repair, and/or replace existing pipe with PVC, and brick manholes with pre-cast concrete manholes. Manholes repaired prior to 1995 are estimated to require additional repairs such as grouting and manhole cover replacements. Abandoned lines are to be plugged and capped at the influent manholes. Excavation, trenching, and pavements demolition and restoration are estimated as required. Roughly 20% of the wastewater collection system base-wide (vitrified clay, cast iron, and transite pipe installed 1952-1962) are past their useful life. Base reports significant sewer maintenance problems with older pipe and brick manholes due to deterioration including extensive infiltration, and pipe separation at joints. Restoring these lines and abandoning lines no longer in use will extend the system life by at least 10 to 25 years and significantly reduce infiltration.
Repair Sanitary Sewer, Phase 4 of 5
Phase 4 of 5: Replace estimated 1910 LF of 6” to 10” Vitrified Clay Pipe and 4” Cast Iron Pipe. Remove and replace 4 brick manholes and repair 2 brick manholes. Abandon 1 sanitary sewer line segment (total of 132 LF) that is no longer in use. Sanitary sewer lines and brick manholes have aged beyond their useful life, require continual maintenance, and contribute unacceptable levels of infiltration to the sanitary sewer system. Corrective action is to clean, repair, and/or replace existing pipe with PVC, and brick manholes with pre-cast concrete manholes. Manholes repaired prior to 1995 are estimated to require additional repairs such as grouting and manhole cover replacements. Abandoned lines are to be plugged and capped at the influent manholes. Excavation, trenching, and pavements demolition and restoration are estimated as required. Roughly 20% of the wastewater collection system base-wide (vitrified clay, cast iron, and transite pipe installed 1952-1962) are past their useful life. Base reports significant sewer maintenance problems with older pipe and brick manholes due to deterioration including extensive infiltration, and pipe separation at joints. Restoring these lines and abandoning lines no longer in use will extend the system life by at least 10 to 25 years and significantly reduce infiltration.
Repair Sanitary Sewer,
Phase 5 of 5: Replace estimated 1500 LF of 6” and 8” Vitrified Clay

Exhibits

Exhibit A—Map of Premises

Maps will be provided on request. These maps show the known locations of the utility system. Portions of the utility system may not be fully shown on the map or maps. Any such failure to show the complete utility system on the map or maps shall not be interpreted as that part of the utility system being outside the Premises. The Premises are co-extensive with the entire linear extent of the utility system sold to Grantee, whether or not precisely shown on the map or maps listed here.

Maps are available, by request to the Government, in PDF format on CD.

Exhibit B—Description of Premises

B.1 General Description of the Utility System, Lateral Extent of the Right of Access, and Points of Demarcation

Utility System Description

The utility system may be composed of, without limitation, collection piping, manholes, final discharge meters, lift stations, treatment plants, supporting emergency generator sets (if any), and electrical controls associated with the lift stations and emergency generator sets on the Installation.

Lateral Extent of Utility System Right of Access For pipe sizes of 24 inches in diameter or less, the Right of Access is 26-feet-wide, extending 13 feet on each side of the utility system, as installed. For pipe sizes greater than 24 inches in diameter, the Right of Access is 50-feet-wide, extending 25 feet on each side of the utility system, as installed.

Utility System Points of Demarcation The point of demarcation is defined as the point on the utility system where ownership changes from the utility system owner to the facility owner. Table 9 identifies the type and general location of the point of demarcation with respect to the facility for each scenario.

TABLE 9

General Points of Demarcation

Sewer Collection System, Niagara Falls ARS

Point of Demarcation (POD)
Applicable Scenario
Sketch

POD is where the service line enters the structure.

Sewer system flow meter is located on the service line entering the structure.

POD is the cleanout device, if within 10 feet of the building perimeter.
No flow meter exists and a sewer system cleanout is located within 10 feet of the building perimeter on the service line.

POD is where the service line enters the structure.

Note: A new cleanout device should be installed within 10 feet of the building during any stoppage or maintenance action. This will then become the new POD.

No flow meter or cleanout exists on the service line entering the structure.

POD is the outfall of the oil/water separator.
Any oil/water separator on the service line.
POD is the outlet side of the Grease Trap, Oil Water Separator, or Pretreatment System.
Grease Trap, Oil Water Separator, and Pretreatment System connected to the wastewater collection system.
None

POD is at the overhead service line’s connection to the service entrance mast.

Note: If an electric meter is present, or is to be installed, the owner of the electric distribution system on the installation is the owner and maintainer of the electric meter and the can. The POD for the electric meter is at the wastewater utility owner’s conductors to the electric utility owner’s conductors. This meter POD applies regardless of the location of the electric utility owner’s meter. The wastewater utility owner will own the service entrance mast.

Electric power is provided to a wastewater facility via an overhead service drop. This configuration could be found at facilities dedicated to the wastewater utility such as a lift station or wastewater treatment plant.
None

POD is at the transformer secondary terminal spade.

Note: If an electric meter is present, or is to be installed, the owner of the electric distribution system on the installation is the owner and maintainer of the electric meter. The POD for the meter is at the wastewater utility owner’s conductors to the electric utility owner’s conductors. This meter POD applies regardless of the location of the electric meters and transformers.

Electric power is provided to a wastewater facility via an underground service connection. This configuration could be found at facilities dedicated to the wastewater utility such as a lift station or wastewater treatment plant.
None

Unique Points of Demarcation:

Table 10 lists anomalous points of demarcation that do not fit any of the above scenarios. These anomalous or unique points of demarcation shall take precedence over the general points of demarcation shown in Table 9.

TABLE 10

Unique Points of Demarcation

Sewer Collection System, Niagara Falls ARS

Building No.
Point of Demarcation Description
Stormwater Diversion Pump Station
The POD is the location where the discharge line from the pump station exits the lift station and connects to the wastewater collection system beneath the apron. This lift station will continue to be owned by the Air Force.
End of Main Wastewater Collection System
The POD for the end of the main wastewater collection system is at the east end of the collection system where the force main from the main lift station enters the Niagara County Sewer District No.1 manhole. The manhole is located in Walmore Road east of the base.
Fire Training Area
The Fire Training area is located at the west end of the Installation. The POD for the end of the pipeline that conveys water from the collection sump at the Fire Training Area is where the discharge main crosses the property line.

B.2. Description of Restricted Access Areas:

For the areas identified in Table 11, Niagara Falls ARS shall not grant any additional easements, rights of access, leases, permits, licenses, or other access. Niagara Falls ARS recognizes that these areas require restricted access and the UP Contractor may take appropriate action to prevent unauthorized access to such areas. This only applies to access by others than the UP Contractor and will not limit any right of access by public authorities charged with the regulation of UP Contractor’s activities or law enforcement.

TABLE 11

Restricted Access Areas

Sewer Collection System, Niagara Falls ARS

Description
Facility #
State Coordinates
Other Information
Lift Station
731
NA
Prevent Unauthorized Access
Lift Station
822
NA
Prevent Unauthorized Access

Exhibit C—Environmental Baseline Survey

The Air Force has determined that it is not required to conduct an EBS in regard to the sale of this utility system.

J1-i C:\Documents and Settings\dnegron\My Documents\Utility Privatization\Niagra Falls\J4 Niagara Falls ARS WW 10.06.08.doc j26-ii

_1030518152.doc

Structure

Service

Line

Point of

Demarcation

Sewer System

Pipe

Cleanout

_1034595368.doc

Oil / Water Separator

Service

Line

Point of

Demarcation