RFQ # F3YTAJ8199A1010 – Dust Control Booth Response To Questions – 13 September 2018
Question – In regards to the airflow, vendors need to know the total required CFM for the booth, please provide.
Answer – Minimum of 12,000 CFM.
Question – Is a strobe light and fire alarm required inside the booth.
Answer – No.