16" Discharge Centrifugal Pump Specifications

Pump shall be of a centrifugal radial flow type with all mild steel fabrication with the exception of the casing and impeller. Impeller shall have a double suction and the casing shall have a double volute. Pump shaft drive shall be minimum 2 ¼ inch diameter ASTM carbon 1045 PSQ shafting.

Shaft bearings shall be triple seal bearings with lubrication lines run to the front of the trailer from each bearing.

The pump will be powered by a liquid cooled Diesel engine capable of providing at least 140HP at 1,800 RPM, and can operate continuously at angles up to 15 degrees from horizontal. The Diesel engine shall include an electric starter, alternator, regulator, tachometer, oil sight gauge, side load hand-operated clutch, necessary batteries and battery cables, rain cap, 50 gallon capacity fuel tank (minimum), and safety switches for high temperature/low oil pressure.

The pump shall be weld fabricated and attached to a two-wheel trailer that has a minimum 3,500 pound road worthy axle, 15 inch 6-ply tires (minimum), a pin hitch, and an attached 2,000 pound swivel jack.

A steel discharge pipe shall convey the water to the front of the trailer. One section of rubber discharge hose and a hose clamp shall be included.

** These are the minimum specifications/requirements for the pump and trailer. Only offers meeting or exceeding these specifications/requirements will be considered for award. All offers must include sufficient support data to show that the products offered, meet or exceed, the minimum requirements. Failure to provide adequate support data will automatically disqualify your offer. **