Exhibit_A_-_Cost_Proposal_Workbook.xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- 280-3132302-RB (Step Two of a Two Step Procurement)
- Issued by
- Orange County, San Francisco City, California
About this file
This is a Cost Proposal Workbook for a Design-Build project for Vertical Conveyance Phases 2-4 at the County of Orange, John Wayne Airport in California. The project encompasses the design, engineering, permitting, and installation of multiple elevator and escalator systems across 28 individual units, organized by manufacturer and type. The work includes 19 Westinghouse hydraulic elevators (Units 1-9, 13-21, and 23), 4 Schindler hydraulic elevators (Units 10-12 and 22), 1 Schindler traction elevator (Unit 24), 4 Fujitec traction elevators (Units 25-28), and 3 Schindler escalators (Units 7, 8, and 9). Each elevator installation requires comprehensive line items including demolition and disposal, core machinery and control systems, structural upgrades, cab enclosure improvements, door systems, hall fixtures, machine room HVAC, pit drainage compliance, lobby finishes, network system integration, low voltage work, electrical installation, fire alarm, and fire sprinkler integration. The proposal also includes interim maintenance services for turned-over units and four add alternates covering escalator structural truss replacement, hydraulic elevator cylinder/jack replacement, asbestos/hazardous materials abatement, and moisture intrusion and hydraulic leakage mitigation allowances.
All prices submitted in the cost proposal matrix must be firm, fixed, and fully inclusive of all design, engineering, calculations, permitting fees, labor, materials, and cross-trade coordination required to deliver fully operational, code-compliant systems meeting or exceeding performance criteria. Bidders are instructed that no qualifications, assumptions, or modifications to scope boundaries are acceptable, and any attempt to qualify the submitted numbers may result in the bid being deemed non-responsive. The contract structure includes a Base Bid GMP covering standard design and construction services plus four optional add alternates that the County may elect to include in the final contract award. The proposal workbook format requires unit pricing for individual line items across all conveyance systems, with subtotals calculated for each elevator or escalator grouping and a cumulative total project GMP reflecting all base bid and alternate pricing.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cost Proposal Format Bid Form Instructions:
All prices submitted in this matrix shall be firm, fixed, and fully inclusive of all design, engineering, calculations, permitting (less fees), labor, materials, and cross-trade coordination required to deliver a fully operational, code-compliant system that meets or exceeds the Performance Criteria outlined in the Criteria Documents. No qualifications, assumptions, or modifications to the scope boundaries written on or attached to this form will be accepted. Any attempt to qualify these numbers may result in the bid being deemed non-responsive.
| Service: | Unit Price: | Qty: | Total: | |
| Design & Preconstruction Services | ||||
| 1 | ||||
| Westinghouse Elevators (Hydraulic) Elevator 1-9, 13-21, and 23 (19 units total) | ||||
| Demolition & Disposal | 19 | |||
| Core Machinery & Control Systems | 19 | |||
| Misc. Metals / Structural Upgrades | 19 | |||
| Cab Enclosure and Interior Upgrades | 19 | |||
| Door Systems | 19 | |||
| Hall Fixtures & Signal Equipment | 19 | |||
| Machine Room HVAC | 19 | |||
| Pit Drainage Compliance | 19 | |||
| Lobby Finishes | 19 | |||
| Network System Integration (BMS / VMS / Paging System Integration) | 19 | |||
| Low Voltage | 19 | |||
| Electrical | 19 | |||
| Fire Alarm | 19 | |||
| Fire Sprinkler | 19 | |||
| Subtotal: | ||||
| Schindler Elevators (Hydraulic) Elevator 10-12, 22 (4 units total) | ||||
| Demolition & Disposal | 4 | |||
| Core Machinery & Control Systems | 4 | |||
| Misc. Metals / Structural Upgrades | 4 | |||
| Cab Enclosure and Interior Upgrades | 4 | |||
| Door Systems | 4 | |||
| Hall Fixtures & Signal Equipment | 4 | |||
| Machine Room HVAC | 4 | |||
| Pit Drainage Compliance | 4 | |||
| Lobby Finishes | 4 | |||
| Network System Integration (BMS / VMS / Paging System Integration) | 4 | |||
| Low Voltage | 4 | |||
| Electrical | 4 | |||
| Fire Alarm | 4 | |||
| Fire Sprinkler | 4 | |||
| Subtotal: | ||||
| Schindler Elevator (Traction) Elevator 24 (1 unit total) | ||||
| Demolition & Disposal | 1 | |||
| Core Machinery & Control Systems | 1 | |||
| Misc. Metals / Structural Upgrades | 1 | |||
| Cab Enclosure and Interior Upgrades | 1 | |||
| Door Systems | 1 | |||
| Hall Fixtures & Signal Equipment | 1 | |||
| Machine Room HVAC | 1 | |||
| Pit Drainage Compliance | 1 | |||
| Lobby Finishes | 1 | |||
| Network System Integration (BMS / VMS / Paging System Integration) | 1 | |||
| Low Voltage | 1 | |||
| Electrical | 1 | |||
| Fire Alarm | 1 | |||
| Fire Sprinkler | 1 | |||
| Subtotal: | ||||
| Fujitec Elevators (Traction) Elevator 25-28 (4 unit total) | ||||
| Demolition & Disposal | 4 | |||
| Core Machinery & Control Systems | 4 | |||
| Misc. Metals / Structural Upgrades | 4 | |||
| Cab Enclosure and Interior Upgrades | 4 | |||
| Door Systems | 4 | |||
| Hall Fixtures & Signal Equipment | 4 | |||
| Machine Room HVAC | 4 | |||
| Pit Drainage Compliance | 4 | |||
| Lobby Finishes | 4 | |||
| Network System Integration (BMS / VMS / Paging System Integration) | 4 | |||
| Low Voltage | 4 | |||
| Electrical | 4 | |||
| Fire Alarm | 4 | |||
| Fire Sprinkler | 4 | |||
| Subtotal: | ||||
| Schindler Escalators 7, 8 and 9 (3 units total) | ||||
| Demolition & Disposal | 3 | |||
| Core Mechanical & Drive Systems | 3 | |||
| Step & Chain Assembly | 3 | |||
| Balustrade, Handrail & Trim | 3 | |||
| Safety & Signal Equipment | 3 | |||
| Architectural Cladding & Finishes | 3 | |||
| Network System Integration (BMS Integration) | 3 | |||
| Low Voltage | 3 | |||
| Electrical | 3 | |||
| Fire Alarm | 3 | |||
| Fire Sprinkler | 3 | |||
| Subtotal: | ||||
| Interim Maintenance (For turned-over units, prior to warranty period start) | ||||
| 1 | ||||
| General Conditions | ||||
| 1 | ||||
| General Requirements | ||||
| 1 | ||||
| Insurance | ||||
| 1 | ||||
| Payment & Performance Bonds | ||||
| 1 | ||||
| Contractor Mark-Up | ||||
| 1 | ||||
| Contractor Contingency | ||||
| 1 | ||||
| Sub-Total Base Bid GMP | ||||
| 1 | ||||
| Add Alternate 1. Escalator Structural Truss Replacement | ||||
| 3 | ||||
| Add Alternate 2. Hydraulic Elevator Cylinder/Jack Replacement | ||||
| 23 | ||||
| Add Alternate 3. Asbestos / HazMat abatement allowance | ||||
| 1 | ||||
| Add Alternate 4. Moisture intrusion & Hydraulic leakage mitigation allowance | ||||
| 1 | ||||
| Total Project GMP (Base Bid GMP + All Add Alternates) |