Exhibit 6 - Plans~9.pdf

PDF 957 KB Posted

Attached to
ESB Mosier Deicer Tanks & Distribution
Solicitation number
S-73000-00017782
Issued by
Oregon

About this file

This file is a site plan and engineering drawing document prepared by the Oregon Department of Transportation for a secondary containment structure and building cover project located in Mosier, Oregon, Wasco County. The project involves the construction of a pre-engineered metal building (PEMB) with secondary containment capacity designed to hold deicer tanks for ODOT operations. The structure will be 748 square feet in actual area, constructed as a Group U (Utility and Miscellaneous) occupancy classified as Construction Type II-B (Unprotected, Non-Combustible), and located on Tax Lot 2N 11E 2 D 300. The secondary containment system must provide capacity exceeding 10% of total primary container volume (2,000 gallons) and 100% of the largest container volume (10,000 gallons) in compliance with 40 CFR 264.175 requirements. The project site is situated at coordinates 45.68194 latitude and -121.40523 longitude within the Mosier City Limits.

The engineering specifications require compliance with the Mosier Municipal Code, Wasco County General Requirements, and the 2016 Oregon Structural Specialty Code. Design parameters include a basic design wind speed of 99 MPH, design ground snow load of 42 psf, frost depth of 24 inches, and a presumptive soil load bearing capacity of 1,500 psf in Site Class D. Material requirements specify ASTM-compliant steel components, hot dip galvanized PEMB framing per ASTM A123, 3,300 psi concrete for all concrete work, and well-graded 3/4-inch minus crushed rock for granular structure backfill compacted to 95% maximum dry density. All work must be performed with submittals of stamped working drawings and calculations to the Engineer for approval prior to fabrication, and the contractor must complete special inspections as required by the Oregon Structural Specialty Code Chapter 17. The document is dated January 3, 2025, with a professional engineer stamp from Paul Joseph Strausser (PE #82398, expires 06-30-2026).

View the file

Other files

File Type Posted
00017782_RFCQ.docx DOCX document
Attachment B - Sample Contract~16.docx DOCX document
Attachment A Form A-2_Bid Pricing Form~4.xlsx XLSX spreadsheet
Exhibit 5 - Specifications~4.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2025.01.03 11:02:49-08'00'

OF TRANSPORTATION

OREGON DEPARTMENT

Checker:Drafter:

Designer:

SHEET NO.

BUILDING NO.

BDS DWG NO.

CALC. BOOK

COUNTY Reviewer:

AVAILABLE UPON REQUEST

FINAL ELECTRONIC DOCUMENT

WASCO COUNTY

TAX LOT 2N 11E 2 D 200

OREGON DEPARTMENT OF TRANSPORTATION PROPERTIES

Secondary Containment Structure and Building Cover

District 9 - Mosier, OR

HWY:

M.P.:

DATE

F O

T N

E

MTRAPED

N

O G

E R

O

N

OI

T

ATROPS

N A

R T

Johathan S. Doughton

Johathan S. Doughton

Paul J. Strausser

Rhonda L. Freeman

SITE PLAN

SCALE WARNING

DRAWING IS NOT TO SCALE

MEASURE ONE INCH, THEN

IF THIS SCALE LINE DOES NOT

WASCO

N/A

N/A

01/25

OREGON

RE

GI

ST

ERE

DPROFESSIONALEN

GINEER

RENEWS: 06-30-2026

P A

U

L

JOSEPH STRA

U S E

RM

A Y

23,2

82398PE

N/A

BR_PIN4650_510_D9_gen_01.dgn :: C01 1/6/2025 3:11:43 PM hwye43p

R O

C K C

R E E

K R

D

Taxlot 2N 11E 2 D 300

Taxlot 2N 11E 2 903

Slope finished grade to drain away from the containment system, approximately six inches over ten feet.

all site work and obtain approval prior to constructing footings and slabs.

compacted to 95% of maximum dry density per ASTM D1557. Provide compaction test reports to the Engineer for

Subbase material for slabs and footings shall be undisturbed natural ground or granular structure backfill

SITE WORK

Furnish exposed fastener metal roof and siding. Install siding between purlins.

Provide a well graded, 3/4" minus crushed rock or approved equal for granular structure backfill.

Hot dip galvanize plates, threaded rods, hardware, and all PEMB framing according to ASTM A123.

Furnish ASTM A36 steel for embedded plates.

Furnish heavy hex nuts according to ASTM A563 Grade A and washings according to ASTM F436.

Furnish grade 55 theaded rod according to ASTM F1554.

Furnish grade 60 reinforcing steel according to ASTM A615, ASTM A496, or ASTM A82.

Furnish structural, non-epoxy grout from the ODOT QPL suitable for bearing applications.

Furnish general structure concrete, 3300 psi for all concrete.

MATERIAL REQUIREMENTS

Obtain approval from the Engineer prior to fabrication.

Submit stamped working drawings and calculations to the Engineer for approval .

PRE-ENGINEERED METAL BUILDING (PEMB) REQUIREMENTS

container volume (2000 gallons) and 100% of the largest container volume (10000 gallons).

40 CFR264.175 - Secondary containment provides capacity exceeding 10% of total primary

OREGON OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REQUIREMENTS

Collateral Load = 5 psf

Seismic Design Base Shear = 0.103WRoof Live Load = 20 psf

Seismic Design Category DDesign Ground Snow Load = 42 psf

Site Class DPresumptive Soil Load Bearing = 1500 psf

: 0.461 and 0.325 D1 and S

DS

Design Spectral Accelerations SExposure Category C

: 0.492 and 0.227 and S S

Mapped Spec. Response Accel SBasic Design Wind Speed = 99 MPH

Risk Category IISevere Weathering Class

Seismic Importance Factor = 1.0Frost Depth: 24" all other applicable state and local regulations.

Requirements, Commercial Building Requirements of the 2016 Oregon Structural Specialty Code (OSSC 2016), and

Building Code Perform all work in strict compliance with the Mosier Municipal Code (MMC), Wasco County General, GENERAL BUILDING REQUIREMENTS

Actual Area = 748 SFBase allowable area = 8500 SF

Construction Type: II-B (Unprotected, Non-Combustible)

Occupancy Class: Group U (Utility and Misc.)

Industrial Zone (I)

CODE DATA

Salem, OR 97302Wasco County

4040 Fairview Industrial Drive, SECity of Mosier

Oregon Department of TransportationOwner:Tax Lot: 2N 11E 2 D 300Site:

Construct secondary containment system and building cover.

DESCRIPTION OF WORK

Taxlot 2N 11E 2 D 200

Taxlot 2N 11E 2 402

Taxlot 2N 11E 2 D 200

Taxlot 2N 11E 2 D 201 structure

Proposed structure

Existing

Mosier City Limits

Mosier City Limits

LOCATION MAP

LAT. 45.68194, LONG. -121.40523

SEC. 02, T. 02 N., R. 11 E., W.M.

Mosier City Limits

Wasco County upon completion of construction.

* Building Number to be assigned

DEFERRED SUBMITTALS

prior to pouring foundations.

Submit building reactions to the Engineer of Record

Pre-engineered metal building plans and calculations.

Oregon Structure Specialty Code, Chapter 17.

Complete special inspections as required by the

SPECIAL INPECTIONS

C01

ODOT ENTRANCE

2025.01.03 11:03:18-08'00'

File details come from the government source that posted it. Updated .