EVT0010853_-_Appendix_E_(ITS_Specifications_and_Details).pdf
PDF 28 MB Posted
- Attached to
- Web-Based Preparedness Application State and local contract opportunity
- Solicitation number
- EVT0010848
- Issued by
- Sedgwick County, Kansas
About this file
Summary
This file contains Appendix E of the Intelligent Transportation System (ITS) Specifications and Details for a Kansas Department of Transportation (KDOT) project, serving as the technical design documentation for ITS infrastructure installation. The project encompasses the installation of various ITS devices including Dynamic Message Signs (DMS), Closed-Circuit Television (CCTV) cameras, vehicle detection systems, fiber optic communications infrastructure, ITS cabinets, pull boxes, splice vaults, transformers, and associated electrical and communications conduit across multiple sites. The specifications detail comprehensive requirements for device placement, foundation construction, cable routing, grounding systems, and coordination with existing utilities including CenturyLink/Lumen fiber, Kansas Turnpike Authority facilities, and municipal services. Key contractor responsibilities include utility location and notification via 811, site surveying and staking, equipment storage coordination, traffic control implementation, conduit installation in both trenched and bored configurations, fiber optic cable pulling and splicing, GPS documentation of all installed devices, and project restoration including seeding of disturbed areas. The documentation emphasizes strict compliance with National Electrical Code standards, KDOT utility accommodation policies, and coordination requirements with utility companies, particularly regarding work within specified clearance distances from existing fiber and high-voltage infrastructure.
The specifications establish detailed technical standards for materials, installation methods, and quality control throughout the project execution. All equipment and materials must meet Buy America Act requirements per Title 2 CFR Part 184. Contractor responsibilities include proper grounding of all equipment and cabinets using minimum No. 4 copper conductors connected to ground rods, installation of tracer wire in all conduits with appropriate color coding (red for power, orange for communications in KDOT areas; yellow and blue respectively in KC Scout areas), and placement of in-ground locate test stations at specific intervals. The project requires extensive documentation including monthly GPS location reports with decimal degree accuracy within three feet, cable tagging with site and device identification, and submission of actual cabinet elevation drawings prior to installation. Payment terms are structured as lump sum site items with incidental costs for utility coordination, material restoration, seeding, and equipment storage. The KDOT ITS Engineer must receive minimum three working days notice for initial commissioning and seven working days notice for site visits, with final project completion requiring contractor coordination for one-call locates of newly constructed facilities prior to acceptance.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| EVT0010848_-_RFP_Document.pdf | ||
| Bid_Amendment_-_EVT0010848_-_Bid_Amendment_2.pdf | ||
| Bid_Amendment_-_EVT0010848_-_Bid_Amendment_1.pdf | ||
| EVT0010853_-_Bid_Documents.pdf | ||
| Web-Based_Preparedness_Application.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOT TO SCALE
CCTV / DETECTOR
PROPOSED
BUTTERFLY
PROPOSED DUAL-SIDED DMS
BUTTERFLY
EXISTING DUAL-SIDED DMS
TWO-POST ROADSIDE
PROPOSED DMS
CONDUIT (KDOT)
EXISTING FIBER AND
(FOR THIS SHEET ONLY)
LEGEND
CONDUIT (KDOT)
PROPOSED FIBER AND
BUTTERFLY
PROPOSED SINGLE-SIDED DMS
emphasize actual project limits
Device Overview Sheet shall
Note to Designer:
OLIVER AVE
K-96 E OF
SITE 3
MT VERNON ST
I-135 NB AT
SITE 2
CABINET
NORTH HUB
HUB CABINET
JUNCTION
CABINET
SOUTH HUB
HARRY ST
I-135 SB AT
SITE 8
K-96
K-96
K-42
K-15
K-15
K-254
TMC
S HOOVER RD
K-42 AT
SITE 6
MERIDIAN AVE
I-235 E OF
SITE 7
WEST HUB CABINET
SITE 9
K-96 AT REDBUD TRAIL
SITE 1
CABINET
EAST HUB
GREENWICH RD
K-96 W OF
SITE 4
DEVICE OVERVIEW EXAMPLE
FHWA APPROVAL
DESIGNED
ITS-D00
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
AJS
I T S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c o m
-J
A N -2
:0
01-09-26
DETAILED
DESIGN CK. DETAIL CK.
APP'D.
QUANTITIES
QUAN.CK.
TRACED
TRACE CK.
K-96 AT N WEST ST
SITE 5
Sh. No.
K D
O T G ra p h ic s C e rt if ie d
KDOT Graphics Certified 01-12-2026
XXX-XXX
Sh. No.
Multimode Fiber Optic
Nominal
Parkway
RT
Sta.
ABBREVIATIONS
XX
XX
F&I Furnish And Install
MM Mile Marker
Mile Marker
Fiber Optic Cable Splice Vault without Splice, by Others (CL, KTA, Etc)
Fiber Optic Cable Splice Vault with Splice, by Others (CL, KTA, Etc)
EXISTING DEVICES ARE SHOWN IN PLANS USING HALFTONE/GRAYSCALE
Ramp Meter
Flashing Beacon
6'x6' Loop Detector
6'x10' Loop Detector
6'x30' Loop Detector
Dynamic Message Sign, Ground Mounted (Butterfly, Dual Face)
Dynamic Message Sign, Truss Mounted
CCTV Camera
Radar Vehicle Detector
Radar Vehicle Detection Area
ITS Cabinet with Foundation
Pole Mounted ITS Cabinet
Fiber Optic Cable Splice Vault without Splice
Fiber Optic Cable Splice Vault with Splice
Pull Box
Guy Wire
Dynamic Message Sign, Ground Mounted (Butterfly)
Dynamic Message Sign, Ground Mounted (Dual Post)
L.P.
Underground Power
Category 6 Twisted Pair Ethernet Cable
SIG Traffic Signal
CAT 6
Southbound
Road Weather Information System
Wireless Communication Tower/Pole
New ITS Field Component
Light Pole
Power Pole
Power Supply Assembly
Power Transformer
Power Overhead Source
Power Underground Source
Removal
Sign, Existing
Telephone Pole
Trees, Existing
Truss Sign
City Limits
Conduit, Existing
Conduit, Bored, Proposed
Conduit, On Structure, Proposed
Conduit, Trenched, Proposed
Construction Limits
LEGEND
Above Ground
Approximate
Avenue
Boulevard
Back of Curb
Board of Public Utilities
Bandwidth Manager
Conductor
ITS Cabinet Assembly
Camera Control Receiver
Closed Circuit Television Camera
Coaxial
Communications
Concrete
Center
Detector
Digital Input/Output
Distribution
Dynamic Message Sign
Drive
Each
Eastbound
Edge of Pavement
Edge of Shoulder
Edge of Travel Way
Existing
Fiber Distribution UnitFDU
Exist.
EOTW
EOS
EOP
EB
Ea.
Dr.
DMS
Dist.
DIO
DET
Ctr.
Conc.
Comm.
Coax.
CL
CCTV
CCR
CA
C
BWM
BPU
BOC
Blvd.
Ave.
Approx.
AG Flex.
FO
FT
FTC
HAR
HDPE
HH
Hwy.
IN
I/O
ITS
KDOT
KTA
Ln.
LS
LT
Min.
MMFO
MP
MPH
NB
No.
Nom.
PB
Pkwy.
POP
Flexible
Fiber Optic
Feet
Field Traffic Controller
Highway Advisory Radio
High Density Polyethylene
Handhole (Splice Vault)
Highway
Inch
Input/Output
Intelligent Transportation System
Kansas Department of Transportation
Kansas Turnpike Authority
Lane
Lump Sum
Left
Minimum
Milepost
Miles per Hour
Northbound
Number
Pull Box
Point of Presence
PP
PS
PVC
Rd.
Req'd.
RMC
Rte.
R/W
SB
SMFO
St.
SV
SW
TB
TMC
Trfwy.
Typ.
Truck
UIP
UP
SOP
VDS
WB
XFMR
Power Pole
Power Supply/Assembly
Polyvinyl Chloride
Road
Required
Rigid Metal Conduit
Right
Route
Right-of-Way
Single-mode Fiber Optic
Street
Station
Splice Vault
Sidewalk
Transition Box
Traffic Management Center
Trafficway
Typical
Truckline
Use In Place
Source Of Power
Vehicle Detection Station
Westbound
Transformer
CenturyLink/Lumen
Dynamic Message Sign, Trailer Mounted
Easement, Permanent
Easement, Temporary
Telephone Cable
Fiber Optic Cable
Gas Line
Fiber Optic Cable, Existing
Gas, Existing
Telephone, Existing
Guard Rail, Existing
Guard Rail, Proposed
Hedge, Existing
Marsh
Power, Existing
Property Line
Railroad, Existing
R/W, Existing
R/W, Existing Access Control
R/W, Access Control
Township, Section or Grant Line
State/County Line
Culverts, Existing
Drop Inlet & Storm Sewer, Existing
Fence, Existing
LEGEND AND ABBREVIATIONS
ITS-D01
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
01-09-26 2025 KDOT Standards Updates JAN 01 AJS
S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
Temp Esmt.
Perm Esmt.
Exist R/W
PoP Building
Roadside Unit (C-V2X)
Automated Gate
K D
O T G ra p h ic s C e rt if ie
GENERAL NOTES
CCTV lowering device.
The Contractor shall install detectors and antennas so as to not interfere with the37.
and the DMS orientation detail.
CCTV cameras and DMS shall be oriented according to the CCTV orientation detail36.
placement of camera poles.
so that they are not directly beneath the camera. The Engineer shall approve and would not expose workers to traffic. Pole mounted cabinets shall be installed operations is: not on the downhill side of a slope, not directly beneath the camera, CCTV poles should be oriented so that pole handhole used for camera lowering 35.
items necessary are in place to provide a fully functioning DMS system.
conduit, pull boxes, controller assemblies, power supply assemblies, and all other
DMS shall not be attached to the support posts until the supporting systems of34.
installation.
Any modifications to the design require the approval of the ITS engineer prior to they will provide for the correct height of the overall DMS structure when installed.
elevations of DMS foundations, pole lengths, and site conditions to ensure that
Prior to installing DMS support structures, the Contractor shall verify final33.
in kind by the Contractor, with no additional payment.
existing improvements removed or damaged by the Contractor shall be replaced any existing conductors or other facilities damaged during construction. All
It shall be the Contractor's responsibility to repair any existing conduit and replace32.
repair".
additional details. Repairs will be paid for under ITS unit cost item "conduit
Contractor to inspect and repair existing conduit. See conduit specifications for31.
parallel shall share the same trench.
Warning tape is required in all trenches containing conduit. Multiple conduits in 30.
power drop locations for all proposed equipment.
Contractor shall not begin work at any site until power company has confirmed 29.
listed on the electrical service location summary sheet.
completion. Utility company, contact name, and phone number for each site are possession of electrical bills 60 days after KDOT inspector has signed off on site company fees until KDOT or KC Scout assumes ownership. KDOT will take the locations shown on the plans. Contractor shall make payment of all power
KDOT's name when in KDOT area or KC Scout's name when in KC Scout area at
Contractor shall be responsible for ordering and paying for any electrical service in 28.
the Engineer.
equipment, cabinet, and ground rods per applicable standards or as directed by installation of all project materials. The Contractor shall properly ground all
(NEC) and manufacturer specifications. Follow applicable NEC requirements for
All grounding systems shall be in accordance with the National Electric Code 27.
responsibility of the parties controlling the physical performance of the work.
around high voltage lines or other utility structures as these items are the equipment, sequencing of work, and safety practices used when working in, on, or requirements. KDOT has no control over the means, methods, choice of performed in conformance with all state, local, federal, utility, and contract
High voltage power lines may be within the project limits. All work is to be 26.
When within 5 ft of KDOT lighting facilities, conduit shall be hand dug.25.
CenturyLink/Lumen inspector present.
allowed when performing work with CenturyLink/Lumen while KDOT and and 5 ft of clearance from CenturyLink/Lumen and / or KTA fiber. Exception
Contractor to maintain at least 20 ft of clearance from all existing gas facilities 24.
coordinated with Lumen and KTA. Hydro excavation is allowed.
All work within 10 ft of CenturyLink/Lumen and/or KTA fiber backbone shall be 23.
present.
or splice vault for any reason without a CenturyLink/Lumen and/or KTA inspector
At no time shall the Contractor access a CenturyLink/Lumen and/or KTA pullbox 22.
facilities.
applicable, and KDOT inspector must be present for work within 5 ft of fiber optic
CenturyLink/Lumen or KTA backbone fiber. A CenturyLink/Lumen, KTA when weeks and again at 72 hours prior to performing any work within 5 ft of a
Contractor shall notify CenturyLink/Lumen and/or KTA when applicable two 21.
power supply poles at the right-of-way line/fence when possible.
from plan location must be approved by the Engineer. Locate transformers and
Transformer locations as shown have appropriate clear zone protection. Variation 20.
must be approved by the Engineer.
from back of guard rail to face of equipment pole. Variation from plan location equipment poles shall be located such that there is a minimum of 7 ft of clearance
Where applicable, and when ITS poles are to be placed near existing guardrail, ITS
ITS equipment pole locations as shown have appropriate clear zone protection. 19.
during this period.
the Notice to Proceed (NTP). The Contractor will not be charged working days surveying operations may begin after th contract is signed, but prior to issuing
With the Engineer's approvl, the off-loading of KDOT provided equipment and18.
designated KDOT facility.
Installation, testing, and integration of all ITS devices, including KDOT furnished 17.
designated KDOT facility.
shall coordinate with the Engineer and manufacturer for a storage location at a facility, installation, and testing in accordance with the specifications. Contractor equipment, shall include all loading and transportation from a designated KDOT furnished, including DMS, CCTV assemblies, detectors, and communications
All ITS equipment called out by plans and specifications as "install" or KDOT 16.
to the site bid item.
incidental items at the arranged storage location. This item of work is incidental means to unload and load KDOT/KTA furnished DMS signs, cabinets and furnished DMS signs, cabinets, and incidental items. Contractor shall provide the
Contractor shall coordinate with the Engineer a location to store KDOT/KTA15.
furnished items.
Contractor shall carefully review plans and specifications for details on KDOT
KDOT will furnish hardware as decribed in the plans and specifications.14.
All traffic control plans and lane closures shall be pre-approved by the Engineer.13.
by the Contractor per KDOT's utility accommodation policy.
Bridge attachments require a separate permit from KDOT that shall be obtained 12.
of conduit.
determine the types and extent of incidental items to be included in the unit price junction boxes) for all externally mounted conduits prior to submittal of bid to mounting hardware (including bridge hangers, fittings, expansion joints and
The Contractor shall field review conduit on structure for necessary routing, 11.
to right-of-way line.
route trunkline conduit adjacent to right-of-way line and branch line perpendicular locator service markings, to prevent conflicts with existing utilities. Contractor to based on actual field conditions prior to construction at each site, including utility right-of-way to the extent possible. The Contractor shall determine final routing
Conduit shall be installed in straight lines either parallel or perpendicular to the 10.
approved by the Engineer prior to placing the cabinet.
strength measurements to Engineer prior to installation. The location shall be ensure connectivity to the cellular network. Contractor shall submit signal
Contractor shall check cellular connection at the specific cabinet location(s) to 9.
the project and no additional payment will be made.
equipment. Any restaking necessitated by adjustment is considered incidental to
KDOT ITS Engineer prior to revising the plan location or orientation of any ITS location sensitive. The Contractor and Engineer shall receive approval from the obstructions. DMS, CCTV camera, detector, and wireless equipment locations are and may be modified to avoid conflicts with underground utilities or other
Engineer prior to placement. Proposed ITS equipment locations are approximate surveyors leave each site. Orientation of all cabinets shall be approved by the boxes must be approved by the Engineer prior to construction and before
Placement of all DMS and CCTV foundations, cabinets, transformers, and pull 8.
foundations, cabinets, power services, pull boxes, and splice vaults.
Survey and stake all ITS device locations including, but not limited to: poles, 7.
services at (913) 895-1806.
location services. When in Johnson County, also call Water One locate request contact any and all utilities and local government agencies not participating in lighting and ITS (fiber, other) be marked in that area. The Contractor shall also area. The Contractor shall call the KDOT Field Engineer to request that KDOT
811 or 1-800-344-7233 (1-800-DIG-SAFE) to request the utilities be marked in that
Prior to beginning any construction activities, the Contractor shall call dig safe at 6.
otherwise noted.
The Contractor shall adhere to KDOT's utility accommodation policy unless
Contractor shall contact the Engineer upon determination of any utility conflicts.
lighting and fiber, in the field prior to initiation of construction per site. The
Contractor shall determine any conflicts with existing utilities, including KDOT 5.
Contractor and may change at no additional cost to KDOT.
area will be up to 1 acre but is based on the construction methods of the to the construction per lump sum site. It is anticipated that the total disturbed specifications for cool grass mix design. Seeding shall be considered incidental lbs/acre. Seeding shall be completed in accordance with KDOT standard
Seeding mix shall be tall fescue (endophyte free) pure live seed (PLS), 220 4.
is incidental to the site bid item.
provided according to the KDOT utility accommodation policy. This item of work prevent ponding. Adequate temporary protection against erosion shall be required by the Engineer. All grading work shall slope away from foundations to debris from the work area according to the KDOT standard specifications and as includes seeding, fertilizing, mulching, and the removal of all unused material and
Contractor shall be responsible for restoring all disturbed work areas. Restoration 3.
original condition. No additional payment will be made.
irrigation systems disturbed during construction activities shall be restored to the work with the Engineer to provide mitigation solutions. Any landscaping or landscaped features and irrigation systems existing within the right-of-way, or
In urban settings, contractor shall maintain an appropriate clearance from all 2.
devices within the existing roadway right-of-way.
responsibility of the Contractor to verify and keep installation of all equipment and
All work will be confined within the existing roadway right-of-way. It is the 1.
etc.).
traffic control, immediate removal of materials, removal of equipment each night, urban areas) additional special considerations may be required (e.g. temporary behind the first post of the end terminal). At limited right of way locations (e.g.
equipment must be located at the back of the ROW, behind guardrail (e.g. 50 feet longer term storage is arranged with the Engineer. Overnight storage of
Stockpiles shall be temporary in nature and removed as soon as practical unless obstruction to vehicular or pedestrian traffic or interfere with surface drainage.
locations will only be allowed in a location that will not cause damage or circumstances) and as far to the edge of the right-of-way as possible. Storage is permitted, then it must be located beyond the Clear Zone (e.g. 55' in most
Engineer and Area Utility Coordinator prior to storage. If such storage or parking no other alternative is available. All storage locations shall be coordinated with the
Freeway, or Highway Right-of-Way will not be permitted on the right-of-way unless equipment and vehicles when not used in actual utility work within the Interstate, Storage of materials, such as rock that has been excavated, and parking of 49.
considered subsidiary to the bid item for installation of multiduct/conduit.
similar) shall be used. This work will not be paid for separately but will be
(meeting FA-A or FA-B requirements or similar) or clean rock (meeting CA-5 or limits and suitable backfill. If outside material is neded for adequate backfill sand trench width. The Engineer shall make the final determination on overbreakage as backfill within 12" in any direction of the multiduct/conduit for at least the greater than 4" or sharp-edged rock) expansive clay or non-durable shale be used damage the conduit shall not be used. In no case shall large or sharp rock, (e.g.
methods approved by the Engineer. Compaction methods or equipment that
(MR-90) specification. Each layer shall be mechanically compacted by means and specified by the manufacturer (e.g. A-1 designated backfill) compacted to Type B shall be used. Suitable material for backfill shall generally be considered as material is not available in the trench excavation for this backfill ouside materials material either from the trench excavation or from outside. If suitable granular requirements. This extra depth excavation shall be backfilled with suitable encountered, the contractor shall contact the Engineer to determine backfill
Where rock, hardpan, shale, expansive clay or other unyielding material is 48.
to be installed more than 7 feet from the ROW, contact the engineer.
Contractor shall install the conduit within the utility corridor. If the conduit needs 47.
commissioning, grounding, and patch panel installation.
installation, fiber splicing and testing of devices and infrastructure. For example, The KDOT ITS Engineer must be notified at least 3 working days prior to the initial 46.
requirements on sheet ITS-SMD.
For 7-way microduct installation, refer to boring method and locator ball 45.
discretion of KDOT.
be removed from the project or the material accepted at a reduced price at the unaccepted materials will be performed at the Contractor's risk. Such material will
Incorporate only tested or approved material into the project. Any work utilizing 44.
existing tracer wire and test station is working properly.
coordinate with KDOT ITS to perform an initial one-call locate to ensure new and
After final project completion and prior to project acceptance Contractor shall 43.
needed for access to KDOT facilities (e.g. POP buildings, TMC, etc.)
commissioning, requested site visits, etc. A minimum of 3 working days notice is
The Contractor shall provide a minimum of 7 working days notice for 42.
part 184 of Code of Federal Regulations.
All material shall meet the Buy America Act Requirements outlined in Title 2 CFR 41.
be made.
and contingency plans are incidental to the site bid and no additional payment will controlled demolition special provisions. Controlled demolition, demolition plans, demolition plans to the Field Engineer per KDOT specifications and per KDOT and butterfly structures is a controlled demolition. Contractor shall submit
Controlled demolition: the removal of existing static sign structures, cantilever, 40.
Engineer.
reports with GPS coordinates of newly installed conduit and vaults to the ITS during construction and until final acceptance. Contractor will provide monthly
Contractor is responsible for one-call locates of the newly constructed facilities 39.
GPS Location Excel Spreadsheet for all installed devices.
box prior to placing backfill material. Contractor shall complete the KDOT-provided decimal degrees) and three tie-point measurements for each buried electrical pull of the GPS readings shall be within 3 ft. Obtain GPS (latitude and longitude in vaults, cabinets, power meters, transformers, and wireless towers. The accuracy latitude and longitude for all installed devices (DMS, CCTV, DET), pull boxes, splice
The Contractor shall provide KDOT an Excel spreadsheet of GPS readings in 38.
ITS GENERAL NOTES
ITS-D02
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
Sh. No.
K D
O T G ra p h ic s C e rt if ie
KDOT Graphics Certified 01-13-2026
K075NBC-151.41
CL/L-AP1001
FOR KDOT INSTALLATIONS
DEVICE LEGEND
CABLE, CONDUIT, AND
FHWA APPROVAL
DESIGNED
ITS-D03A
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
S -D
A .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
K 075 NB C
PEDESTAL FOR POWER CO. SERVICE
5 FT AT EACH POWER POLE OR POWER
5 FT AT EACH DMS
5 FT AT EACH CCTV
5 FT AT EACH ITS CABINET ASSEMBLY
(LOAD AND SERVICE SIDE)
5 FT AT EACH POWER SUPPLY ASSEMBLY
C A
B L E
C A
T
CATEGORY 6 CABLE
CONDUIT (FT) CABLE (FT)
FROM TO
D I S
T A
N C
E
C T
R T
O C
T R
(FT)
TRENCHED BORED
STRUCTURE
ON
POWER COMM. DETECTOR DEVICE
4321FIBER OPTIC543212S3B2BSTXT3T2T1T
I
N
I
N
I
N
X
S P
A R
E
I
N
I
N
I
N
G R
E E
N
R E
D
G R
E E
N
R E
D
B L
A C
K
G R
E E
N
R E
D
G R
E E
N
R E
D
G R
E E
N
R E
D
G R
E E
N
R E
D
R M
C
I
N
X
X
X
X
S M
F O
12 XX
S M
F O
X X C
C T
V
D M
S
V D
S
CONDUIT AND / OR CABLE RUN CARRIES OVER TO ADJACENT SHEETS
TOTAL
MAX. HEIGHT OF DETECTOR ON POLE ASSUMED AT 25 FT FOR CABLE QUANTITIES
NOTES:
INCLUDED IN TABLE
ADDITIONAL CONDUIT QUANTITIES
CONDUIT SYMBOL LEGEND
SB
3B
2B
ST
XT
3T
2T
1T
TRENCHED
BORED
ADDITIONAL CABLE QUANTITIES INCLUDED IN TABLE
POWER CABLES
FIBER OPTIC TRUNKLINE CABLES (XX SMFO)
25 FT AT EACH PULL BOX (WHEN NOT SPLICING)
FOR FUTURE USE
100 FT AT EACH SPLICE VAULT
SPLICE VAULT WHEN SPLICING
50 FT FROM EACH DIRECTION AT EACH
FIBER OPTIC BRANCH CABLES (XX SMFO)
EXCEED 328 FEET IN LENGTH.
ENGINEER'S DISCRETION TO ENSURE RUNS DO NOT
THESE QUANTITIES MAY BE ADJUSTED AT THE STATE ITS
10 FT COIL AT EACH MID-RUN PULL BOX
5 FT COIL EACH AT PULL BOX WHERE SPLICED TO LOOP WIRE
10 FT COIL AT EACH ITS CABINET
SB
S P
A R
E
I
N B
L A
C K
2 IN RMC
X-WAY MICRODUCT
X IN (HDPE)
(HDPE)
2 IN SPARE
3 IN (HDPE)
2 IN (HDPE)
(HDPE)
2 IN SPARE
X-WAY MICRODUCT
X IN (HDPE)
3 IN (HDPE)
2 IN (HDPE)
1 IN (HDPE)
specifications for details.
wire unless stranded is required for better flexibility. See ITS
For all power and communications conduit, install solid tracer 9.
will be made.
considered incidental to the project and no additional payment does not include the required ground wire. Ground wire is electrical cables. The number of conductors listed in the table
Ground wire is required to be installed for conduits with 8.
equivalent.
designated by their rounded nominal inch (in) diameter
All conduit sizes are industry standard English size conduit 7.
will be made.
considered incidental to the project and no additional payment shall cut off and discard the first 10 ft of the cable. This 10 ft is
After pulling fiber optic cable through the boxes, the Contractor 6.
foot.
as given on this sheet, and are rounded up to the nearest whole
Total lengths of conduit and cable include additional quantities 5.
accommodated in cable quantities and are incidental.
nearest whole foot. Grade elevation changes are not
Center to center horizontal distances are rounded up to the 4.
be rigid metal (RMC), unless otherwise noted.
Trenched conduit shall be HDPE, and conduit on structures shall 3.
All lengths in tables are measured in feet.2.
consistent across sites within the same project.
Table may be modified to fit project needs. Tables shall be 1.
SLACK BACK TO NEAREST PULL BOX.
SLACK IN THE CABINET AND SHALL PULL ALL EXCESS
CONTRACTOR SHALL LEAVE A MINIMUM OF 2 FT OF
DISTANCE.
QUANTITIES SHOWN INCLUDE SLACK AND VERTICAL
50 FT COIL AT EACH OVERHEAD DMS
25 FT COIL AT EACH ROADSIDE DMS
5 FT COIL AT EACH PULL BOX
10 FT COIL AT EACH ITS CABINET ASSEMBLY
10 FT COIL AT EACH TRANSFORMER
8 FT COIL AT SERVICE PEDESTAL (TYPE 2)
36 FT COIL AT SERVICE POLE (TYPE 2)
7 FT COIL AT TYPE 2 SERVICE SIDE
7 FT COIL AT TYPE 2 LOAD SIDE
36 FT COIL AT TYPE 1 SERVICE POLE
50 FT AT EACH POWER SUPPLY ASSEMBLY
EXCESS SLACK BACK TO THE NEAREST PULL BOX.
OF SLACK IN THE CABINET AND SHALL PULL ALL
CONTRACTOR SHALL LEAVE A MINIMUM OF 2 FT
FOR FUTURE USE
25 FT AT EACH PULL BOX OR SPLICE VAULT
VAULT WHEN SPLICING
100 FT FROM EACH DIRECTION AT EACH KDOT SPLICE
50 FT AT EACH ITS CABINET LOCATION
REQUIREMENTS IN SPECIFICATIONS.
CONTRACTOR TO FOLLOW SLACK
ARE FOR THE DESIGN ENGINEER'S ESTIMATE ONLY.
* ADDITIONAL QUANTITIES ADDED TO THE TABLE
CODE.
THE PROVIDER'S SPLICE POINT USING THEIR ID
A THIRD PARTY PROVIDER'S SPLICE POINT, LABEL
** WHEN SPLICE VAULT IS LOCATED ADJACENT TO
EB - Eastbound, WB - Westbound
NB - Northbound, SB - SouthboundDirection:
Route: US 75
LETTERS FOR CAMERAS AND DETECTORS.
VAULTS AND PULL BOXES. USE SEQUENTIAL
POST. USE SEQUENTIAL NUMBERS FOR SPLICE
THERE ARE MULTIPLE DEVICES AT THE SAME MILE
* ONLY USE SEQUENTIAL NUMBERS OR LETTERS IF
Z - Zayo IDEA - Ideatek L - CenturyLink/Lumen KTA - Kansas Turnpike Authority K - Kansas DOTAgency:
XXX.XX
Mile Post or Reference Marker
X-
Sequential Number or Letter*
PP - Power Pole
PB - Pull Box
CT - Trailer Camera
CA - ITS Cabinet
C - Camera (CCTV)
BT - Bluetooth
AG - Automated Gate
Device:
DEVICE ID CODE LEGEND
V - Vehicle Detection Station
T - Transformer
SV - Splice Vault**
ST - Trailer DMS
S - Sign (DMS)
RS - RWIS Sensor
PS - Power Supply / Assembly
CCTV/DMS/VDS CABLES
POLE HEIGHT (VARIES) AT EACH POLE
10 FT COIL AT EACH PULL BOX
5 FT COIL AT EACH DEVICE
10 FT COIL AT EACH ITS CABINET
REQUIREMENTS IN SPECIFICATIONS.
CONTRACTOR TO FOLLOW SLACK
ARE FOR THE DESIGN ENGINEER'S ESTIMATE ONLY.
* ADDITIONAL QUANTITIES ADDED TO THE TABLE
ON STRUCTURE2S
From Device No.
To Device No.
Center Distance
Device Center to Number of
Size and
Structure
Conduits on
6 Cable
Total Length of Category Size, Color, and Number of
Conduits in Trench and
Size, Color
Bore
Conduits in
Number of
Power Cable Size Cable
Fiber Optic
Fiber Count CCTV/DMS/VDS
CONDUIT AND CABLE ROUTING TABLE
Device-Specific
Cables
XB
* FOR EXAMPLE 7-WAY MICRODUCT, UTILIZE "7" IN PLACE OF "X", SO IT WILL BE "M7T".
Sh. No.
MXT*
MXB*
K D
O T G ra p h ic s C e rt if ie
K075NBC-05
PB075-02-08
KDOT075-01
075K NB C 05-
075 02 08- -PB
075 01-KDOT
NOTES:
Route: US 75
State: K-Kansas
Route: US 75
Device: PB - Pull Box
Route: US 75 specifications for details.
wire unless stranded is required for better flexibilty. See ITS
For all power and communications conduit, install solid tracer 9.
will be made.
considered incidental to the project and no additional payment does not include the required ground wire. Ground wire is electrical cables. The number of conductors listed in the table
Ground wire is required to be installed for conduits with 8.
equivalent.
designated by their rounded nominal inch (in) diameter
All conduit sizes are industry standard English size conduit 7.
will be made.
considered incidental to the project and no additional payment shall cut off and discard the first 10 ft of the cable. This 10 ft is
After pulling fiber optic cable through the boxes, the Contractor 6.
foot.
as given on this sheet, and are rounded up to the nearest whole
Total lengths of conduit and cable include additional quantities 5.
accommodated in cable quantities and are incidental.
nearest whole foot. Grade elevation changes are not
Center to center horizontal distances are rounded up to the 4.
be rigid metal (RMC), unless otherwise noted.
Trenched conduit shall be HDPE, and conduit on structures shall 3.
All lengths in tables are measured in feet.2.
consistent across sites within the same project.
Table may be modified to fit project needs. Tables shall be 1.
Number of
Size and
Structure
Conduits on
6 Cable
Total Length of Category
C A
B L E
C A
T
From Device No.
To Device No.
Center Distance
Device Center to Size, Color, and Number of
Conduits in Trench and
Size, Color
Bore
Conduits in
Number of
Power Cable Size Cable
Fiber Optic
Fiber Count CCTV/DMS/VDS
Device-Specific
Cables
CONDUIT AND CABLE ROUTING TABLE
CONDUIT (FT) CABLE (FT)
FROM TO
D I S
T A
N C
E
C T
R T
O C
T R
(FT)
TRENCHED BORED
STRUCTURE
ON
POWER COMM. DETECTOR DEVICE
4321FIBER OPTIC543212S3B2BSTXT3T2T1T
I
N
I
N
I
N
X
S P
A R
E
I
N
I
N
I
N
B L
A C
K
Y E L L
O W
B L
U E R
M C
I
N
X
X
X
X
S M
F O
12 XX
S M
F O
X X C
C T
V
D M
S
V D
S
CONDUIT AND / OR CABLE RUN CARRIES OVER TO ADJACENT SHEETS
TOTAL
MAX. HEIGHT OF DETECTOR ON POLE ASSUMED AT 25 FT FOR CABLE QUANTITIES
SB
S P
A R
E
I
N B
L A
C K
T - Transformer FB - Flashing Beacon
PS - Power Supply Assembly VR - Mainline Radar Detection
PP - Power Pole S - Sign (DMS)
- Ramp Detector (Loop)RV CA - ITS Cabinet
RM - Ramp Meter C - Camera (CCTV)
BT - BluetoothDevice:
Device Number
DEVICE ID CODE LEGEND
Sequential Number
Device Number (Match Cabinet No.)
EB - Eastbound, WB - Westbound
NB - Northbound, SB - SouthboundDirection:
CL - CenturyLink/Lumen Splice Vault
KDOT - KDOT Splice Vault
KDOT Splice Vault No.
FOR KC SCOUT INSTALLATIONS
DEVICE LEGEND
CABLE, CONDUIT, AND
FHWA APPROVAL
DESIGNED
ITS-D03B
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
S -D
B .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
PEDESTAL FOR POWER CO. SERVICE
5 FT AT EACH POWER POLE OR POWER
5 FT AT EACH DMS
5 FT AT EACH CCTV
5 FT AT EACH ITS CABINET ASSEMBLY
(LOAD AND SERVICE SIDE)
5 FT AT EACH POWER SUPPLY ASSEMBLY
INCLUDED IN TABLE
ADDITIONAL CONDUIT QUANTITIES
REQUIREMENTS IN SPECIFICATIONS.
CONTRACTOR TO FOLLOW SLACK
ARE FOR THE DESIGN ENGINEER'S ESTIMATE ONLY.
* ADDITIONAL QUANTITIES ADDED TO THE TABLE
CATEGORY 6 CABLE
ADDITIONAL CABLE QUANTITIES INCLUDED IN TABLE
POWER CABLES
FIBER OPTIC TRUNKLINE CABLES (XX SMFO)
25 FT AT EACH PULL BOX (WHEN NOT SPLICING)
FOR FUTURE USE
100 FT AT EACH SPLICE VAULT
SPLICE VAULT WHEN SPLICING
50 FT FROM EACH DIRECTION AT EACH
FIBER OPTIC BRANCH CABLES (XX SMFO)
EXCEED 328 FEET IN LENGTH.
ENGINEER'S DISCRETION TO ENSURE RUNS DO NOT
THESE QUANTITIES MAY BE ADJUSTED AT THE STATE ITS
10 FT COIL AT EACH MID-RUN PULL BOX
5 FT COIL EACH AT PULL BOX WHERE SPLICED TO LOOP WIRE
10 FT COIL AT EACH ITS CABINET
SLACK BACK TO NEAREST PULL BOX.
SLACK IN THE CABINET AND SHALL PULL ALL EXCESS
CONTRACTOR SHALL LEAVE A MINIMUM OF 2 FT OF
DISTANCE.
QUANTITIES SHOWN INCLUDE SLACK AND VERTICAL
50 FT COIL AT EACH OVERHEAD DMS
25 FT COIL AT EACH ROADSIDE DMS
5 FT COIL AT EACH PULL BOX
10 FT COIL AT EACH ITS CABINET ASSEMBLY
10 FT COIL AT EACH TRANSFORMER
8 FT COIL AT SERVICE PEDESTAL (TYPE 2)
36 FT COIL AT SERVICE POLE (TYPE 2)
7 FT COIL AT TYPE 2 SERVICE SIDE
7 FT COIL AT TYPE 2 LOAD SIDE
36 FT COIL AT TYPE 1 SERVICE POLE
50 FT AT EACH POWER SUPPLY ASSEMBLY
EXCESS SLACK BACK TO THE NEAREST PULL BOX.
OF SLACK ON THE CABINET AND SHALL PULL ALL
CONTRACTOR SHALL LEAVE A MINIMUM OF 2 FT
FOR FUTURE USE
25 FT AT EACH PULL BOX OR SPLICE VAULT
VAULT WHEN SPLICING
100 FT FROM EACH DIRECTION AT EACH KDOT SPLICE
50 FT AT EACH ITS CABINET LOCATION
CCTV/DMS/VDS CABLES
POLE HEIGHT (VARIES) AT EACH POLE
10 FT COIL AT EACH PULL BOX
5 FT COIL AT EACH DEVICE
10 FT COIL AT EACH ITS CABINET
REQUIREMENTS IN SPECIFICATIONS.
CONTRACTOR TO FOLLOW SLACK
ARE FOR THE DESIGN ENGINEER'S ESTIMATE ONLY.
* ADDITIONAL QUANTITIES ADDED TO THE TABLE
B L
U E
Y E L L
O W
B L
U E
Y E L L
O W
B L
U E
Y E L L
O W
B L
U E
Y E L L
O W
B L
U E
Y E L L
O W
CONDUIT SYMBOL LEGEND
SB
3B
2B
ST
XT
3T
2T
1T
TRENCHED
BORED
2 IN RMC
X-WAY MICRODUCT
X IN (HDPE)
(HDPE)
2 IN SPARE
3 IN (HDPE)
2 IN (HDPE)
(HDPE)
2 IN SPARE
X-WAY MICRODUCT
X IN (HDPE)
3 IN (HDPE)
2 IN (HDPE)
1 IN (HDPE)
ON STRUCTURE2S
XB
MXT*
MXB*
* FOR EXAMPLE 7-WAY MICRODUCT, UTILIZE "7" IN PLACE OF "X", SO IT WILL BE "M7T".
K D
O T G ra p h ic s C e rt if ie
ITS EXAMPLE QUANTITIES
ITS-D03C
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
10-06-23 2023 KDOT Standards Updates JAN 00
BY
S -D
C .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
INFORMATION ONLY
QUANTITIES ON THIS SHEET ARE SHOWN FOR
INTELLIGENT TRANSPORTATION SYSTEM (ITS) SITE
NOTE:
K D
O T G ra p h ic s C e rt if ie
2T
2T 2S
2T
2T
2T
2T 2B
2T
2T
2T
2T
2T
2T 2T
2T
2T
ITS EXAMPLE PLAN
ITS-D03D
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
12-30-20 2020 KDOT Standards Updates JAN 00
BY
S -D
D .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:1
QUAN.CK.
S P
A R
E
C A
B L E
C A
T
400'
364' 2
310'
131'
92'
49'
150'
215'
75'
125'
239'
122B
85'
62'
265'
K035NBCA-151.51
K035NBPS-151.55
K035NBCA-151.51
K035NBS-151.51
NOTE TO DESIGNER:
R/W
R/W
Fiber Optic Cable
R/W
M A
X
SOP BY ABC POWER
I-35 NB
I-35 SB
OP
O V
E R P
A S S -R
O A
D N
A M
E
R/W
CONDUIT AND CABLE ROUTING TABLE
CONDUIT (FT) CABLE (FT)
TRENCHED BORED
STRUCTURE
ON
POWER COMM. DETECTOR DEVICE
FROM TO
D I S
T A
N C
E
C T
R T
O C
T R
(FT)
1T
I
N
R E
D
G R
E E
N
2T
I
N
R E
D
G R
E E
N
R E
D
G R
E E
N
I
N
3T XT
X
R E
D
G R
E E
N
ST
I
N B
L A
C K
R E
D
I
N
G R
E E
N
I
N
R E
D
G R
E E
N 2 I
N
R M
C
X
2 3
X
X
X
FIBER OPTIC
12 XX
S M
F O
S M
F O
X X
1 2 3 4
V D
S
D M
S
C C
T V
K035SBSV-151.18
K035SBCA-151.19
K035SBCA-151.19
TOTAL
1588 362
185 1822
74'
SB
S P
A R
E
I
N B
L A
C K
9 1060 1 2 3 4 1065 6 7 8 9 1 2 3 4 6 7 8 9 1 2
CONSTRUCTION NOTES:
contract.
Coordination and all required work shall be subsidiary to other items of the shall be coordinated between KDOT, Bluestem Electric, and ITS contractor.
Electric will pull their own conductor from power pole to transformer. This work transformer (south side) provided and installed by Bluestem Electric. Bluestem
ITS contractor to install empty 3" HDPE from power pole (north side) to new 8.
For fiber overview and details, see sheets 59-63.7.
sheet 7.
Site shall be paid for by the lump sum. For a summary of site quantities, see 6.
For cross sections at device locations, see sheets 82-84.5.
details.
Distance to cabinet is approximate & may be field adjusted. See ITS-D16 for
CCTV shall be located and oriented as required in order to view DMS messages. 4.
DMS design and orientation angle varies. See ITS-D15 for details.3.
locations.
Stationing is approximate only and is not tied to known survey markers or 2.
The communication method to/from this site is via fiber.1.
DO NOT SCALE LOCATIONS FROM PLAN SHEET.
IS NOT SHOWN TO SCALE FOR PLAN CLARITY.
NOTE: DEVICE AND CONDUIT SYMBOLOGY ON PLAN SHEET
Install Detector Pole and Equipment
Sta. 1079+04, 116' Rt.
K035NBV-151.80
Cabinet Mounted CCTV
Install ITS Cabinet w/
Sta. 1063+90 114' Lt.
K035SBCA-151.19
UNIT QUANTITYITEM
BID ITEM
2B 3B 2S
K035SBPB-151.18-02
K035SBPB-151.18-02
K035SBPB-151.18-03
K035SBPB-151.18-03 K035SBPB-151.18-01
K035SBPB-151.18-01 K035NBPB-151.18-01
K035NBPB-151.18-01 K035NBPB-151.18-02
K035NBPB-151.18-02 K035NBPB-151.37
K035NBPB-151.37 K035NBPB-151.50-02
K035NBPB-151.50-02
K035NBPB-151.50-02
364'
For KC Scout area, use KC Scout naming conventions.4.
Measure station and offset to the center of devices.3.
Coordinate with the KDOT or KC Scout Project Manager for use of aerial imagery.2.
KC Scout area: yellow conduit for electrical cables, blue conduit for communication cables.
Revise conduit color as applicable for installation location. KDOT area: red conduit for electrical cables, green conduit for communication cables.1.
K035SBSV-151.18
K035NBPP-151.55
K035NBPS-151.55
K035NBCA-151.80
K035NBV-151.80
K035SBSV-151.76
K035SBC-151.19
K035SBCA-151.19
K035SBPB-151.18-03
K035NBPB-151.18-01
K035NBPB-151.18-02
K035SBPB-151.18-02
K035SBPB-151.18-01
K035NBPB-151.65-01
K035NBPB-151.80-01
K035NBPB-151.80-02
K0335NBPB-151.80-03
K035NBPB-151.37
K035NBPB-151.50
DMS Rotation = 15°
Structure & DMS
Install Two-Post DMS
Sta. 1061+95 100' Lt.
K035SBS-151.18
SEE CONSTRUCTION NOTE 3 & 6
200'
SEE CONSTRUCTION NOTE 4 & 6
SEE CONSTRUCTION NOTE 4
SEE CONSTRUCTION NOTE 6
SEE CONSTRUCTION NOTE 8
K035SBSV-151.50
K035SBCA-151.19 K035SBS-151.18 200 200 200 225 230
K D
O T G ra p h ic s C e rt if ie
CABINET WALL
NON-CONDUCTIVE FLANGE WASHER NON-CONDUCTIVE WASHER
FLANGE WASHER
TO ACCOMMODATE
DRILL HOLE IN CABINET
TRACER WIRE
SPLIT BOLT W/ STUD
BRASS OR BRONZE ALLOY
(SPLIT BOLT STUD)
DIRECT CONNECT POST
ALLOY TRANSMITTER
BRASS OR BRONZE
ALLOY NUT
BRASS OR BRONZE
CABINET LAYOUT
TYPICAL 334 AND 336S
ITS-D04
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
ITS EQUIPMENT/CABINET LABELING EXAMPLE
NOTES
DEVICE IP ADDRESS(ES)
DEVICE IP ADDRESS(ES)
DEVICE IP ADDRESS(ES)
SWITCH PORT ASSIGNMENTS/CONFIGURATIONS/VLAN
SWITCH IP ADDRESS & VLAN
MILE MARKER
SITE NAME
U
PAD MOUNT
TYPICAL TYPE 334 CABINET
FRONT VIEW BACK VIEW
FRONT VIEW
POLE MOUNT
TYPICAL TYPE 336S CABINET
BACK VIEW
INFORMATION, SEE ITS EQUIPMENT SPECIFICATIONS FOR ADDITIONAL DETAILS.
ITS SPECIFICATIONS, INCLUDE A CABLE TAG WITH SITE AND DEVICE
IN ADDITION TO LABELING EACH DEVICE WITH LABELS AS WRITTEN IN THE
U
U
U
U
Include louvered back plate on all cabinets. 7.
adapter shall be incidental to the site bid item.
space is required, or as requested by the Engineer. Second DIN rail with bracket
Provide a second DIN rail with bracket adapter for ITS equipment if additional 6.
indicate equipment dimensions on elevation drawings.
the front, rear, and side views for proposed equipment placements. Clearly
Provide a rack elevation drawing for each ITS cabinet within the project showing 5.
Door filters shall have full back plates enclosing filter and holding filter in place.4.
See ITS plans and specifications for equipment to be included in cabinets.3.
prior to installation.
Contractor shall submit actual cabinet elevations to the Engineer for approval 2.
above the bottom of ground mounted cabinets.
Power supply assemblies and connections shall be mounted a minimum of 12 in 1.
NOTE: 1U = 1.75 INCHES
LIGHTNING PROTECTION
24"
NOTE: 1U = 1.75 INCHES
ONLY WHERE NOTED
UPS + BATTERIES INCLUDED
BATTERIES
UPS 3
U
LIGHTNING PROTECTION
OTHER EQUIPMENT ON DIN RAIL
CISCO EQUIPMENT AND
WITH BRACKET ADAPTER
DIN RAIL CLIP
PULL OUT DRAWER
GENERAL NOTES:
OF CABINET
ASSEMBLY AT TOP
VENTILATION FAN
OF CABINET
ASSEMBLY AT TOP
VENTILATION FAN
SHELF AREA FOR
ENCODER, MODEM,ETC.
SHELF
FO SPLICE / PATCH HOUSING
CONTROLLER #1
CONTROLLER #2
AC OUTLET/SURGE
BUS BAR, BREAKER
POWER SUPPLY INPUT
ASSEMBLY, SURGE /
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
24" 24"
24"
ENCODER, MODEM,ETC.
SHELF
U
U
U
U
UFO SPLICE / PATCH HOUSING1
U
U CONTROLLER
U
U
U
U
U
U
U
U
ASSEMBLY, SURGE /
BUS BAR, BREAKER
POWER SUPPLY INPUT
AC OUTLET/SURGE
PULL OUT DRAWER
DIN RAIL
OTHER EQUIPMENT ON
CISCO EQUIPMENT
DIN RAIL CLIP
SHELF AREA FOR
U
U
U
U
U
U
INSIDE OF CABINET OUTSIDE OF CABINET
CABINET TRACER WIRE CONNECTION DETAIL
THE BOTTOM SIDE OF THE CABINET NEAREST THE POLE.
B. POLE MOUNTED TYPE 336 CABINET - TERMINAL SHALL BE MOUNTED ON
SIDE.
THE BOTTOM OF THE CABINET UNDER THE BACK CABINET DOOR, HINGE
A. PAD MOUNTED TYPE 334 CABINET - TERMINAL SHALL BE LOCATED NEAR
CABINET EDGES AND SIDE IN WHICH IT IS NOT DIRCTLY MOUNTED TO.
ACCIDENTAL "SNAGGING" . LOCATIONS SHOULD BE A MINIMUM OF 1.5" FROM
6. TERMINAL LOCATION - TERMINALS SHALL BE MOUNTED IN ORDER TO PREVENT
5. APPLY THREAD LOCK SEALANT TO REDUCE TAMPERING.
4. MAINTAIN 1.5" MINIMUM CLEARANCE FOR TERMINAL.
3. HOLE IN CABINET SHALL BE MADE WATER TIGHT.
2. TERMINAL SHALL BE COMPLETELY ISOLATED FROM CABINET & GROUNDING.
FLEXIBILITY CONTACT THE ENGINEER FOR APPROVAL.
ACCESSIBLE FROM THE OUTSIDE OF THE CABINET. IF STRANDED IS NEEDED FOR
1. TRACER WIRE TERMINAL SHALL BE SOLID BRASS OR BRONZE ALLOY &
NOTES
LABEL TRACER WIRE
LOCATE CONNECTION BOLT
LABEL TRACER WIRE
LOCATE CONNECTION BOLT
K D
O T G ra p h ic s C e rt if ie
ITS CABINET DETAILS
ITS-D05
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
07-14-23 2023 KDOT Standards Updates JAN 00
BY
S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
74"
3 3
4 4
PLUG
INSTALL DUCT
DOUBLE CABINET (NEW FOUNDATION)SINGLE CABINET (NEW FOUNDATION)
CONDUIT
SPARE 2"
AS REQUIRED
CONDUITS
MIN.
6"
PLUG
INSTALL DUCT
M I N
A P
R O
N
(T Y P
M I N
ITS
KDOT
IN KC SCOUT AREA.
"KC SCOUT ITS" WHEN
CABINET
TO INSIDE OF
PROVIDE INSULATION
AC UNIT
SEAL ENDS OF CONDUIT
ITS
KDOT
ITS
KDOT
M A
X
A P
R O
N
(T Y P
M I N
M I N
AS REQUIRED
CONDUITS
AS REQUIRED
CONDUIT
CONDUIT
SPARE 2"
MIN.
6"
NOTES:
cabinet doors.
Bollards shall be placed so they do not interfere with shall be placed on all four corners of double cabinet foundation.
paint all exposed surfaces yellow. Dome top of bollard. Bollards
6" schedule 40 round steel pipe filled with concrete. Prime &
F&I duct plug.
F&I in spare conduit, stub out 6 in from face of foundation.
equipment ground bus to ground rod.
Minimum No. 4 copper grounding conductor from cabinet exothermically welded.
at least 2.5 ft deep. Connection to ground rod shall be not to exceed 45 degrees from vertical or buried in a trench vertical position, the rod may be driven at an oblique angle exist which prohibit the placement of the ground rod in a
Grounding rod, 3/4 in x 20 ft min. If subsurface conditions
50 year silicone caulk between cabinet and base.
GENERAL NOTES:
Conduit must enter cabinet foundation on the same side as its approach run.2.
See ITS-D03A or ITS-D03B for fiber optic cable slack.1.
K D
O T G ra p h ic s C e rt if ie
FOUNDATION DETAILS
ITS CABINET
ITS-D06A
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
07-14-23 2023 KDOT Standards Updates JAN 00
S -D
A .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
BACKFILL MATERIAL
6" STONE DRAIN-POROUS
3"
ANCHOR ROD
CONDUITS AS REQ'D.
NOTE:
1.
3 3 plug.
5 F&I 2 in spare conduit, stub out 6 inches from face of foundation. F&I duct ground bus to ground rod.
4 Minimum No. 4 copper grounding conductor from cabinet equipment
3 Stone drain material shall conform to the standard specification.
2 Rebar shall be adjusted to accommodate conduit.
shall be No. 4 bars, evenly spaced at 12 in spacing, +/- 1.5 in.
1 All reinforcing bar used in the construction of the cabinet foundation
CABINET FOUNDATION NOTES:
9" X 16"
CONDUIT AREA
" X 15" X 2"4
ANCHOR ROD, (4)
(DIRECTION)
FACE OF CABINET
2"
4"
"8
15"
" 5"
24"
24"
24"
CONDUIT
POWER LEAD IN
CONDUIT
SPARE 2"
PLUG
INSTALL DUCT
MIN
6"
"8
4"
30"
3" "8
MIN
24"
1" CONDUIT
ITS CABINET FOUNDATION DETAILS
POLE MOUNTED ITS CABINET MAINTENANCE PAD
5'-0"
PAD
MAINTENANCE
CABINET
CABINET
TYP. 336S
L OF DMS OR CCTV POLEC
TYPE B COMPACTION
M I N
MAX.
4"-6"
FABRIC
WELDED WIRE
6X6-W4XW4
3" MIN.
M A
X
5'-0"
ITS CABINET FOUNDATION ON SLOPE DETAILS
CABINET PAD.
VAULT DOWNHILL OF
LOCATE PULL BOXES OR SPLICE
VARIES
V A
R I E S
D E P
T H
E
M B
E D
M E
N T
6'-0"
3"2
"8 side as its approach run.
Conduit must enter cabinet foundation on the same for KDOT-provided cabinets (DMS or otherwise).
Coordinate with the Engineer on anchor bolt spacing
2.
FOUNDATION
FORM AROUND POLE
FOUNDATION AND PAD
BETWEEN POLE
" EXP. JOINT 2
1FORM
.5
" X 20' GROUND ROD OR 2 - 10' GROUND RODS4
K D
O T G ra p h ic s C e rt if ie
FACE OF CABINET (DIRECTION)
FOUNDATION DETAILS
ITS DOUBLE CABINET
ITS-D06B
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
07-14-23 2023 KDOT Standards Updates JAN 00
S -D
B .d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
CABINET FOUNDATION NOTES:
4'- 7"
2'- 6"
2'- 6"
"2
2'-0"
"2
4'-
8"
8"
2'-0"
FOUNDATION & PAD DETAILS
BASE PLAN
MANUFACTURE PRIOR TO CONSTRUCTING BASE.
CONTRACTOR SHALL VERIFY DIMENSIONS FROM CABINET
BASE DIMENSIONS MAY VARY DEPENDING ON CABINET.
9" X 16"
CONDUIT AREA
9" X 16"
CONDUIT AREA
CONDUIT
POWER LEAD IN
1" CONDUIT
4"
30"
3"
24"
MIN
PLUG
INSTALL DUCT
MIN
6"
CONDUIT
SPARE 6"
ANCHOR ROD
CONDUITS AS REQ'D.
PLUG.
5 F&I 2 IN SPARE CONDUIT, STUB OUT 6 IN FROM FACE OF FOUNDATION. F&I DUCT
GROUND BUS TO GROUND ROD.
4 MINIMUM NO. 4 COPPER GROUNDING CONDUCTOR FROM CABINET EQUIPMENT
3 STONE DRAIN MATERIAL SHALL CONFORM TO THE STANDARD SPECIFICATION.
2 REBAR SHALL BE ADJUSTED TO ACCOMMODATE CONDUIT AND BOLLARDS.
SHALL BE NO. 4 BARS, EVENLY SPACED AT 12 IN SPACING, +/- 1.5 IN. SEE ITS-D06 FOR DETAILS.
1 ALL REINFORCING BAR USED IN THE CONSTRUCTION OF THE CABINET FOUNDATION
GENERAL NOTES:
BOLLARD DETAIL
" X 20' GROUND ROD (MIN.)4
PLUG EMPTY CONDUITS (TYP.)
SUBSIDIARY TO THE HUB CABINET.
EITHER PVC OR HDPE, BUT SHALL BE PLUGGED AT EITHER END. CONDUIT IS
PLACED BETWEEN HUB CABINET AND ADJACENT SPLICE VAULTS. CONDUIT MAY BE
3. ON HUB CABINETS (NOT SIGNAL CABINETS), AN EMPTY 6" CONDUIT SHALL BE
SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
2. BOLLARDS SHALL SPACED SO THEY DO NOT INTERFERE WITH CABINET DOORS. THIS
DIMENSIONS FROM CABINET MANUFACTURE PRIOR TO CONSTRUCTING BASE.
1. BASE DIMENSIONS MAY VARY DEPENDING ON CABINET. CONTRACTOR SHALL VERIFY
SUBSIDIARY TO "BOLLARD (PERMANENT)".
FABRICATION WHETHER SPECIFICALLY MENTIONED OR NOT. CONCRETE FOOTING SHALL BE
SHALL INCLUDE ALL THE TIME, MATERIALS, & EQUIPMENT NECESSARY FOR INSTALLATION &
STEEL BOLLARDS SHALL BE SUBSIDIARY TO THE BID ITEM "BOLLARD (PERMANENT)". THIS
3. ALL WORK ASSOCIATED WITH INSTALLATION, CONSTRUCTION, & FABRICATION OF 6"
SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
2. BOLLARDS SHALL SPACED SO THEY DO NOT INTERFERE WITH CABINET DOORS. THIS
EXPOSED SURFACES YELLOW. DOME TOP OF BOLLARD.
1. 6" SCHEDULE 40 ROUND STEEL PIPE FILLED WITH CONCRETE. PRIME & PAINT ALL
3/4" X 15" X 2"
ANCHOR ROD, (4 MIN)
STEEL BOLLARD (TYP.)
DOMED TOP
YELLOW.
PAINT ALL EXPOSED SURFACES
FILLED WITH CONCRETE. PRIME &
6" SCHEDULE 40 ROUND STEEL PIPE
CABINET BASE
FACE OF CABINET (DIRECTION)
REAR DOORS
(M
I N
.5
40.5"
44.5" (MIN.)
9'- 7"
6'- 9"
8'-0" (M
IN.)
3" (TYP.)
3" (T
YP
1'-0"
3"
CONCRETE FOOTING
BACKFILL MATERIAL
6" STONE DRAIN-POROUS
K D
O T G ra p h ic s C e rt if ie
PVC TRACER TOP LID
TIGHTENING ONTO BASE
PENTA HEAD BOLT FOR
TERMINAL
TRACER WIRE
PLASTIC
PVC TOP
TRANSMITTER DIRECT CONNECT POST
FOR EASY DETECTION
ENCAPSULATED MAGNET
(WHEN APPLICABLE)
CONNECTION
TRACER WIRE
TEST STATION WITH
IN-GROUND LOCATE
(WHEN APPLICABLE)
WITH TRACER WIRE CONNECTION
IN-GROUND LOCATE TEST STATION
IN 1" CONDUIT
GROUND WIRE,
AND ONE
TRACER WIRE
WIRES,ONE
2- #12 SOLID
SWITCH
GROUND
TERMINAL
SWITCH
GROUND
JUMPER
SWITCH
GROUND
ITS PULL BOX DETAILS
ITS-D07
STATE
KANSAS
YEARPROJECT NO.
SHEETS
TOTAL
SHEET NO.
DATE REVISIONS APP'DNO.
KANSAS DEPARTMENT OF TRANSPORTATION
01-09-25 2024 KDOT Standards Updates JAN 00
BY
AJS
06-04-25 Tracer Wire Updates JAN 01 AJS
01-09-26 2025 KDOT Standards Updates JAN 02 AJS
I T S -D
.d g n
F il e
P lo tt e d b y J
B a il e y s rf c o n s u lt in g .c
-J
A N -2
:0
QUAN.CK.
3"
SEE NOTE 13
CONCRETE PAD
BOLT (2 REQUIRED)
51/64 PENTA-HEAD
STAINLESS STEEL
#4 REBAR (TYP.)
REQUIRED
CONDUIT AS
CABLE TO BE INSTALLED (TYP.)
EXCEED BEND RADIUS OF
CONDUIT RADIUS SHALL NOT
MATERIAL
POROUS BACKFILL
STONE DRAIN -
SECTION C-C
BOLT HOLE
TYPICAL BOLT CLEANOUT
SECTION B-B SECTION A-A
MATERIAL
POROUS BACKFILL
STONE DRAIN -
CABLE TO BE INSTALLED
EXCEED BEND RADIUS OF
CONDUIT RADIUS SHALL NOT
M I N
4" MIN. 4" MIN.
REQUIRED
CONDUIT AS
TYPICAL 4 PLACES
(CABLE HOOKS)
MOLDED INSERT
9" 24" #4 REBAR (TYP.)
A L L S I D
E S
T
Y P
C
B
B
AA
A L L S I D
E S
T
Y P
#4 REBAR (TYP.)
C
E L E
C T
R I C
K D
O T
SURFACE
SKID RESISTANT
NOTES:
GENERAL NOTES:
.5
FOR COMMUNICATION PULL BOXES ONLY
IN-GROUND LOCATE TEST STATION DETAIL
BOLT (2 REQUIRED)
51/64 PENTA-HEAD
STAINLESS STEEL
SURFACE
SKID RESISTANT
I T S
K D
O T
SURFACE
SKID RESISTANT
BOLT (2 REQUIRED)
51/64 PENTA-HEAD
STAINLESS STEEL
H I G
H V
O L T
A G
E
K D
O T C
A U
T I O
N
PREFORMED PULL BOX COVER
WHEN CONTRACTOR LEAVES, THEY SHALL LEAVE THE GROUND OFF.3.
2. TRACER LID SHALL BE ORANGE FOR COMMUNICATIONS AND RED FOR POWER AND INCLUDE A CAST-IRON FLANGE FOR LOW TRAFFIC.
WITH A 48-INCH COPPER ROD EXPOSING ONLY 12 INCHES.
TRACER WIRE SHALL BE SOLID BRONZE ALLOY & ACCESSIBLE FROM THE TOP OF LID WITHOUT REQUIRING LID REMOVAL. GROUND
1. USE TWO-TERMINAL SWITCHABLE LID. COPPERHEAD INDUSTRIES SNAKEPIT PART NUMBER SP-SWLID-*2 OR APPROVED EQUAL.
of the related conduit. Test stations are incidental to pull boxes.
the same side as conduits is exiting pull box. Match test station color to the color each direction of conduit leaving the pull box. Test stations must be located on in-ground locate test station(s). Locate stations are required for
All KDOT ITS Communication Pull Boxes must include an 5 by a ground bushing and No. 4 bare copper wire.
All metal conduits shall be electrically bonded4
Text shall be 2 in high and centered. Maintain adequate letter width and spacing.
DMS cables shall have 5" x 11" cast-in, stamped concrete labels with "KDOT/ITS".
Pull boxes with loop lead-in cables, detector cables, communication cables, or 3 centered. Maintain adequate letter width and spacing.
labels with "KDOT CAUTION/HIGH VOLTAGE". Text shall be 2 in high and
Pull boxes with 480V conductors shall have 5" x 11" cast-in, stamped concrete 2 adequate letter width and spacing.
labels with "KDOT/ELECTRIC". Text shall be 2 in high and centered. Maintain
Pull boxes with 120/240V conductors shall have 5" x 11" cast-in, stamped concrete 1 the Construction Office for approval.
Contractor shall use grade 4 concrete for concrete pad. This shall be submitted to 13.
to be installed on the existing and new lines.
connecting to is not equipped with a test station, new test stations will be required start of a branch run). If an existing mow strip or splice vault that the contractor is changes direction greater than forty-five degrees or at the end of a fiber run (or there is a splice vault, both sides of a bored conduit deeper than 4', when a run grounding per manufacturer recommendation) is required at each location where station). Multiple runs will require multiple test stations. Selectable ground (and communications run (E.G. entry and exit straight through would require one test communications conduit. Separate stations will be required for each power or locate testing stations. Separate stations shall be provided for power and
All communications and power pull boxes and splice vaults shall be equipped with 12.
Conduit must enter pull box on the same side as its approach run.11.
Substitute "KC SCOUT" for "KDOT" when installations are in KC Scout area.10.
socket and one pull box lifting hook must be provided for each project.
for every 20 pull boxes installed. A minimum of one stainless steel penta-head
Provide KDOT with one stainless steel penta-head socket and pull box lifting hook 9.
clean aggregate.
Stone drain material shall conform to the standard specifications and shall be 8.
77, current edition.
Pull box and cover shall be rated for a minimum loading of tier 22 per ANSI/SCTE 7.
exposing 4" to 6" of individual microducts. See section 6.3.1.
Stub up conduit 6" inside pull box. For multiway microduct, stub up 8" to 12" total, 6.
the conduit.
pulling…