ES-20-01910 Drawings.pdf
PDF 5 MB Posted
- Attached to
- HVAC Replacement Montgomery, AL Federal contract opportunity
- Solicitation number
- 6973GH-20-R-00182
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| OAS 2.5 hvac lit 13-27.pdf | ||
| 01 10 00 Summary of Work MXF 20.pdf | ||
| OAS 2.5 hvac lit 1-12.pdf | ||
| Amendment 0001.pdf | ||
| Experience Information Form.pdf | ||
| Payment Bond.pdf | ||
| Wage Determination.pdf | ||
| 6973GH-20-R-00182.pdf | ||
| Contractor Release Form.doc | DOC document | |
| MXF ASR HVAC Specifications final.pdf | ||
| Performance Bond.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
E D
M
IS
S
U
F
O R
AL
BH
AA 06/16/2020 MXFASR
C
N
T
IO
ENGINEERING SERVICES
OPS INFRASTRUCTURE
ASR
CHANGES AND LAYOUT
ELECTRICAL SINGLE LINE DIAGRAM
HVAC REPLACEMENT
MAXWELL AFB AIRPORTMONTGOMERY
PROJECT ENGINEER MGR: ENGINEERING - CENTER A
MXF-D-ASR-E006
m x f-d -a s r-e .d g n
THIS DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA
G
WP
30A
EHU-2EHU-1
CU-2A
70A
100A
CU-2BACU-1ACU-2
NEW
PNL CEHU-3
30A30A
30AT
30AF
(2 POLE)
100AF
50AT30AT
30AF 30AF
30AT20AT
100AF 100AF
30AT 30AT
80AT
208/120 VOLT
PANEL EPA
600AF
NA
/2
/4 "C
"C
1 1/2"C.,3-#4,1-#8 GRN
"C
"C
"C
600A BYPASS SWITCH
E006
1 SINGLE LINE DIAGRAM (DEMOLITION)
NOT TO SCALE
SCALE: 1/4" = 1'-0"
4' 8'04'
ELECTRICAL WIRING LAYOUT
PULL BOX
WAVEGUIDE
EXISTING
OPENING
TO TOWER
4 - 2 1/2" CNDS.
O.H.
18"x 32"x 8"D
FAA CABLE JUNCTION BOX
B-10
EXIST DELAY LINE OVEN
EPA-21
ACU-1
ACU-2
EPA-22
ROOM
GENERATOR
ENGINE
EQUIPMENT ROOM
VENTILATION
T(2 TYP)
REMOTE SENSOR
POWER
REUSE AS PRACTICAL FOR
TYPICAL CONTROL CONDUIT
PANEL-B
PANEL-D
PANEL-A
PANEL-C
UNDERGROUND
4-3 1/2" CNDS.
(TYP) 6 PLACES
RMM J.B.
8"x 8"x 6"
2" C.O. (TYP)
PANEL SP-1
IN 3" C TO EPA-26, 28, 30
4 #250 MCM, 1 #2 GRD
LIGHTING (TO REMAIN)
EXISTING EMERGENCY EPA-32, 34
6"x 6" WIREWAY
-2
B
A
-1
EPA-4
EPA-9
EPA-10
EPA-16
B-12
(4 EA)
3 R-WP SW
NEMA-3
CONDUIT TO CONDENSER UNITS
1 1/2" RIGID STEEL
31,33,35 32,34
(2 POLE)
37,39,41 36,38,4026,28,3025,27,29
3 PHASE 4 WIRE
20,22,24
19,21,23
14,16,1813,15,17
1,3,5 2,4,6 7,9,11
8,10,12
208/120 VOLT600AMP
600AF
NA
/4 "C
600A BYPASS SWITCH
SINGLE LINE DIAGRAM (NEW CONSTRUCTION)
NOTES
TO BE REMOVED
3/4"C.,3-#10,1-#12 GRN
TO BE REMOVEDTO BE REPLACED
1.
2.
4.
7.
11.
12.
13.
14.
AND NEC.WORK, INTERIOR,
ELECTRICALFAA-C-1217G, GROUNDING, BONDING, AND SHIELDING REQUIREMENTS FOR FACILITIES AND ELECTRONIC EQUIPMENT, LIGHTNING AND SURGE PROTECTION,ELECTRICAL WORK SHALL COMPLY WITH FAA ELECTRICAL STANDARD, FAA-STD-019E, CONDUCTOR. THE BONDING JUMPER SHALL TERMINATE ON FITTINGS LISTED FOR GROUNDING AT EACH END OF THE FLEXIBLE CONDUIT.
INTERNAL EQUIPMENT GROUNDING CONDUCTOR. THE BONDING JUMPER SHALL BE A 6 AWG GREEN-INSULATED STRANDED COPPER
ALL LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) SHALL BE PROVIDED WITH AN EXTERNAL BONDING JUMPER IN ADDITION TO THE
ENCOUNTERED, WITH COMPRESSION FITTINGS INSTALLED AT APPROPRIATE ENDS.
CONDUCTORS 12 AWG AND SMALLER ARE PERMITTED TO BE STRANDED IN APPLICATIONS WHERE VIBRATION AND FLEXING MAY BE
USED. MINIMUM CONTROL WIRE SIZE SHALL BE 14 AWG UNLESS OTHERWISE REQUIRED BY MANUFACTURER OR NOTED ON DRAWINGS.
SHALL BE 12 AWG. IF REQUIRED SPECIFIC EQUIPMENT INSTALLATIONS, STRANDED CONDUCTORS FINER THAN CLASS B MAY NOT BE
LARGER SHALL BE STRANDED. STRANDED CONDUCTORS SHALL BE UL LISTED CLASS B. MINIMUM BRANCH CIRCUIT CONDUCTOR SIZE
SPECIFICATION A A 59544. CONDUCTORS SIZED 12 AWG AND SMALLER FOR GENERAL USE SHALL BE SOLID. CONDUCTORS 10 AWG AND
THERMOSETTING INSULATION, TYPE THHN-THWN FOR GENERAL USE, ALL INSULATED FOR 600 VOLTS IN ACCORDANCE WITH FEDERAL
UNLESS OTHERWISE INDICATED INSULATED CONDUCTORS SHALL BE COPPER WITH THERMOPLASTIC OR
AIR HANDLING UNITS
FURNISH AND INSTALL NEW CONDUCTORS ( 3-# 4AWG THWN, 1-#8 AWG THWN GREEN GROUND) FROM DISCONNECT SWITCHES, TO NEW
FINAL 6 FEET OF CONDUIT CAN BE MADE WITH A U/L APPROVED LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) AT EITHER ENDS.
FURNISH AND INSTALL 3/4" EMT AS NEEDED FROM EXISTING DISCONNECT SWITCH TO AHU(S).
CORRECT ELECTRICAL CAPACITY FOR THE NEW UNITS AND SHALL BE REUSED. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING:
FOR THE AIR HANDLING UNITS, THE EXISTING CIRCUIT BREAKER, CONDUCTORS AND FUSED DISCONNECT SWITCHES ARE OF THE
DISCONNECT SWITCHES, TO NEW CONDENSING UNITS (CU-1, CU-2).
THE CONTRACTOR SHALL PROVIDE NEW CONDUCTORS ( 3-#2 AWG THWN, 1-#8 AWG THWN GREEN GROUND) FROM NEW BREAKERS TO
FEET OF CONDUIT CAN BE MADE WITH A U/L APPROVED LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) AT EITHER ENDS.
FURNISH AND INSTALL 1 1/2" RIGID METAL CONDUIT (RMC) FROM NEW CU-1 AND CU-2 TO NEW DISCONNECT SWITCHES. FINAL 6
PROOF WITH AN EXTERIOR GRADE SEALANT AND INTERIOR SURFACE FINISHED WITH A 4 HOUR FIRESTOP PUTTY OR CAULK.
EXISTING WALL PENETRATIONS SHALL BE USED AS PRACTICAL. USED AND UNUSED WALL PENETRATIONS SHALL BE MADE WEATHER
STEEL 304 CONSTRUCTION. SWITCHES SHALL BE EXTERIOR MOUNTED APPROXIMATELY WERE PREVIOUSLY SWITCHES WERE LOCATED.
3P3W HEAVY DUTY DISCONNECT SWITCHES WITH CLASS J FUSES. SWITCH ENCLOSURE RATINGS SHALL BE NEMA 4X, OF STAINLESS
CONTRACTOR SHALL FURNISH AND INSTALL TWO(2) NEW SINGLE THROW FUSIBLE 100A 600VAC/DC
TO MATCH EXISTING PANEL.
THE CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) NEW 3 POLE, 100A CIRCUIT BREAKERS
CONDUIT SHALL BE REMOVED.
1" 1/2 INTERIOR CONDUIT(S) SHALL BE REUSED, AS PRACTICAL, FOR NEW ELECTRICAL SERVICE. UNUSED
CU-2B.
THE CONTRACTOR SHALL REMOVE THE EXISTING 3-#4 CONDUCTORS AND #8 GROUND ONCE SERVICING CU-1A, CU-1B, CU-2A AND
CONTRACTOR SHALL REMOVE THE EXISTING EXTERIOR MOUNTED DISCONNECT SWITCHES FOR CU-1A, CU-1B, CU-2A AND CU-2B.
CIRCUIT BREAKERS CU-2A AND CU-2B CIRCUIT BREAKERS SHALL REMAIN IN-PLACE. ASSOCIATED UNUSED CONDUIT TO BE REMOVED.
THE CONTRACTOR SHALL REMOVE CIRCUIT BREAKERS FOR CU-1A, CU-1B (80 AMP, EACH).
OPERATIONAL NEEDS, WORK MAY BE POSTPONED AND RESCHEDULED AT A MOMENTS NOTICE WITH NO ADDITIONAL COST TO THE FAA.
RE-ENERGIZE ANY POWER PANEL OR CIRCUIT BREAKER. DUE TO WEATHER OR OTHER UNEXPECTED IMPACT TO AIR TRAFFIC
POTENTIAL IMPACT TO AIR TRAFFIC. FAA TECHNICIANS SHALL RETAIN THE SINGULAR AUTHORITY TO DE-ENERGIZE AND
BE SCHEDULED WITH NO LESS THAT TWO WEEKS LEAD TIME. THE WORK SHALL BE SCHEDULED AT NIGHT DURING THE LEAST
REQUIRE COORDINATION AND OPERATIONAL RISK MANAGEMENT BY THE FAA. THE WORK SHALL BE SCHEDULED WITH NO LESS.
PANEL EPA SERVICES CRITICAL NATIONAL AIR SPACE (NAS) EQUIPMENT. THEREFORE, THE DE-ENERGIZING OF PANEL EPA WILL
THE HVAC REPLACEMENT PROJECT, CIRCUIT MODIFICATIONS AND BREAKER REPLACEMENT WILL BE NEEDED TO PANEL EPA.
3 PHASE 4 WIRE
P
CU-1B
CU-1A
CPA (NIC)
RADAR PANEL
ASR-9
"x
W
IR
Y
/0
225AT
225AF
EXHAUST FAN
E/G ROOM
31,33,35 32,34 37,39,41 36,38,4026,28,3025,27,2920,22,2419,21,2314,16,1813,15,171,3,5 2,4,6 7,9,11 8,10,12
20AT
EXHAUST FAN
EHU-1
30AT 30AT
EHU-2
100AT
100AT
100AWP
CU-1 CU-2
225AF
225AT
50AT
"x
IR
Y
/0
CPA (NIC)
RADAR PANEL
ASR-9
PNL C
1 1/2"C.,3-#2,1-#8 GRN
3/4"C.,3-#4,1-#8 GRN NEW CONDUCTOR
f-d -a s r-e
/1
:0
:4 lo tt e d b y
V
-C
-E
H
8 7 6 5 4 3 2 1
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
REDLINE
APVD
mxf-d-asr-e006
2020-06-18T15:30:51-0400
SUSHMA H PATEL
2020-06-17T14:47:59-0400
ALAIN P ALDAMA
f-d -a s r-g lo tt e
MXF-D-ASR-G004
f-d -a s r-g
VICINITY MAP
COVER SHEET, LOCATION MAP AND VICINITY MAP
LOCATION MAP
MXF ASR
T OF TRANSPO
T A
IC
OF
STATES
IT
TM
EN
AVIA
I
LAR
TRAT
SI
NI
KELLY STREET, MONTGOMERY, ALABAMA 36112
FAA MXF-ASR FACILITY, MAXWELL AFB
MXF/ASR - MONTGOMERY, ALABAMA
mxf-d-asr-g004
2020-06-18T15:32:05-0400
SUSHMA H PATEL
2020-06-17T14:53:23-0400
ALAIN P ALDAMA
f d a s r g
INDEX AND ABBREVIATIONS
MXF-D-ASR-G005
DRAWING NO. REV. DATE DESCRIPTION
ABBREVIATIONS
DRAWING LIST
BOTTOM OF DUCT
CUBIC FEET PER MINUTE (ACTUAL)
CONNECTION
FINISH
FULL LOAD AMPS
FLEXIBLE
FLOOR
LOCKED ROTOR AMPS
MAXIMUM
OUTSIDE AIR
MINIMUM
SUPPLY AIR
RATED LOAD AMPS
RETURN AIR
VOLUME DAMPER
TYPICAL
THICK
WITH
BOD
CFM
CONN
FIN
FLA
FLEX
FLR
LRA
MAX
OPER
OA
MIN
SA
RLA
RA
VD
TYP
THK
W/
TOD TOP OF DUCT
CP CONTROL PANEL
OPERATION/OPERATING
DUCT SUPPORT
ELECTRICALELECT
EMERG
DS
EMERGENCY
EXIST EXISTING
AD AUTOMATIC DAMPER
A/C
APPROX APPROXIMATELY
AIR CONDITIONING
T-STAT THERMOSTAT
AUTO AUTOMATIC
BLDG BUILDING
ARCHITECTURAL
DWG DRAWING
ARCH
M MOTOR
SPT SPRING POWERED TIMER
GFM GOVERNMENT FURNISHED MATERIAL
06/16/2020
MXF-D-ASR-E006
MXF-D-ASR-M012
MXF-D-ASR-M011
MXF-D-ASR-M010
MXF-D-ASR-M009
MXF-D-ASR-G005
MXF-D-ASR-G004
ELECTRICAL SINGLE LINE DIAGRAM CHANGES AND LAYOUT
CONTROL SYSTEM
NEW CONSTRUCTION PLAN
HVAC SCHEDULES
EXISTING HVAC DEMOLITION PLAN
INDEX AND ABBREVIATIONS
COVER SHEET, LOCATION AND VICINITY MAPS
f-d -a s r-g
:5 lo tt e mxf-d-asr-g005
2020-06-18T15:34:12-0400
SUSHMA H PATEL
2020-06-17T14:54:50-0400
ALAIN P ALDAMA
f-d -a s r-lo tt e
DEMOLITION PLAN
EXISTING HVAC
MXF-D-ASR-M009
f-d -a
PAD
CONCRETE
CONDENSING
UNIT
PIPE ANCHOR TYP.
MOISTURE INDICATING
SIGHT GLASS
LIQUID LINE - 7/8"
SUCTION LINE - 1-3/8"
CORK & NEOPRENE
ISOLATERS
1 2
ACU ACU
DOOR
TURNING VANES18x20
ONLY ONE LINE SHOWN FOR
CLARITY
(TYP)
LINED PLENUM
1" CONDENSATE DRAIN
(ROUTE ALONG WALL BETWEEN
TO THE OUTSIDE)
TURNING
VANES
ROOF
DECK
ACU
FLEXIBLE 20"x 18"
REFRIGERANT
PIPING (TYP)
20" x36"
ACOUSTIC LINED
PLENUM
BACKDRAFT
DAMPERS
REMOVAL & CLEANOUT (TYP)
T-2
T-1 ROOM T-STAT FOR
ACU-2 SET AT 85°F
26"x 20"
2A 2B
ADM
CU
2A
REFRIGERANT PIPING TO
CU CUAND
CONCRETE SPLASH
BLOCK
(FOR CONDENSATE
DRAIN)
DM-2
AD
2B
1A
1B
36" x20"
E/G ROOM AND MECH. EQ. ROOM
DAMPERS (TYP)
WALL SLEEVES (TYP)
3'W x15' L x1'-10" D
CONNECTION (TYP)
1" CONDENSATE DRAIN TRAP
WITH 2 UNIONS FOR
TO REMAIN
DUCT
REFRIGERANT PIPING (TYP)
REMOVE
M009
SCALE: 1/4" = 1' - 0"
FLOOR PLAN
SECTION
2 REFRIGERANT PIPING AT ALL CU'S
26" x 20"
36"x 20"
PIPING
EQUIPMENT ROOM ENGINE GENERATOR
MECHANICAL
13'-6"
FULL WIDTH OF UNIT (TYP)
TREATED TIMBER (TYP)
MOUNT CU'S ON 4"x 4"
FOR REUSE WITH NEW EQUIPMENT. SUPPORTS NOT USED SHALL BE REMOVED.
SUPPORTS FOR ELECTRICAL CONDUITS AND REFRIGERANT PIPING SHALL REMAIN TO THE EXTENT PRACTICAL8.
CIRCUIT BREAKERS. INTERIOR CONDUIT TO REMAIN AND BE REUSED.
CONTROL WIRING, DISCONNECT SWITCHES, POWER CONDUIT AND CONDUCTORS BACK TO, AND INCLUDING, REMOVE CU-1A, CU-1B, CU-2A AND CU-2B. REMOVAL SHALL INCLUDE UNIT, REFRIGERANT, REFRIGERANT PIPING, 7.
REMOVE DUCTWORK FLEXIBLE CONNECTION. HARD DUCTWORK TO REMAIN.6.
REMOVE EXISTING ISOLATION DAMPERS, DAMPER ACTUATOR AND CONTROLS. HARD DUCTWORK TO REMAIN.5.
CONDUIT LENGTH AS NEEDED TO POWER NEW AHU(S).
SWITCHES, POWER CONDUIT AND ASSOCIATED CIRCUIT BREAKERS TO REMAIN AND BE REUSED. MODIFIED REFRIGERANT PIPING, POWER CONDUCTORS, CONTROL WIRING WITH CONDUIT. THE EXISTING DISCONNECT
REMOVE AHU-1, AND AHU-2. REMOVAL SHALL INCLUDE UNIT, BASE MOUNTS, ANCHOR SUPPORTS, REFRIGERANT, 4.
OR (AHU-2, CU-2A & CU-2B). SEE RECOMMENDED SEQUENCE OF WORK FOR FURTHER REQUIREMENTS.
SYSTEM FOR THE FACILITY. REMOVE AND REPLACE ONE EXISTING SYSTEM AT A TIME. (AHU-1, CU-1A &CU-1B)
INSURE THAT THE TEMPORARY HVAC SYSTEM REMAINS FUNCTIONAL AT ALL TIMES. IT SHALL BE THE BACK-UP3.
DISCONNECT SWITCHES SHALL BE REMOVED / REPLACED.
CONDENSING UNITS CU-1A, CU-1B, CU-2A AND CU-2B. LOTO SHALL BE AT THE ELECTRICAL PANEL LEVEL, CU
CONTRACTOR SHALL LOTO (LOCK OUT AND TAG OUT) ALL ELECTRICAL POWER FOR AHU-1, AHU-2, AND ASSOCIATED2.
WILL REQUIRE FAA APPROVAL (SUBMITTAL REQUIRED).
COLUMN. ORIGINAL SUPPORT SHALL BE REINSTALLED AFTER OTHER WORK IS COMPLETE. PLAN AND MATERIAL EQUIPMENT ROOM. TWO, FLANKING TEMPORARY SUPPORTS WILL BE INSTALLED BEFORE REMOVAL OF SUPPORT
SELECTIVELY REMOVE THE EXISTING CANOPY SUPPORT COLUMN THAT BLOCKS ACCESS TO THE MECHANICAL 1.
REFRIGERANT PIPING TO
CU CUAND
1A 2A
ARE ADDED. NOTE 1
REMOVED AFTER NEW SUPPORTS
CANOPY SUPPORT TO BE
ROOM T-STAT FOR ACU-1 SET AT 75°F
SEE CONTROL DRAWING
TO BE REPLACED AND RELOCATED
mxf-d-asr-m009
2020-06-18T15:35:18-0400
SUSHMA H PATEL
2020-06-17T14:55:37-0400
ALAIN P ALDAMA
MANUFACTURER
EQUIPMENT
NUMBER AMPS CFM
THROW
(FT.)
AIR TEMP.
RISE ( F)
MIN. MTG.
HEIGHT
OUTDOOR WINTER
DESIGN TEMP ( F)
W/WALL MOUNTING
BRACKETS AND
BUILT-IN THERMOSTATS
FAN DATA
LOCATION
ELECT. INPUT
HEATER DATA
208V, 30, 60Hz
ROOMEUH-1
EUH-3
3.0 KW
10,255 BTUH
8.3 350
ELECT. INPUT
BELOW 50
W/WALL MOUNTING
BRACKETS AND
BUILT-IN THERMOSTATS
REMARKS
CAPACITY
NO.
MANUFACTURER LOCATION
HOUSING
MODEL AND
TYPE
2 HIGH x 2 WIDE
MEDIA MODEL AND TYPE NUMBER AND SIZE OF FILTERS ARRANGEMENT REMARKS
F-1
(4)
FARR
SINGER
5.0 KW
17,075 BTUH
30/30
2" REPLACEABLE 24"x 24"x 2"
INDOOR
TYPE 8
WITH DWYER MODEL
2001-AF MAGNAHELIC
AIR FILTER GAUGEE/G ROOM
EUH-2
W/WALL MOUNTING BRACKETS
& BUILT-IN THERMOSTATS
5.0 KW
17,075 BTUH
13.9
13.9 350 15208V, 30, 60Hz 50
9 20 TO 40
20 TO 40
MANUFACTURERS INDICATED ARE FOR REFERENCE ONLY IN ORDER TO ESTABLISH REQUIRED PERFORMANCE VALUES.
OTHER ACCEPTABLE MANUFACTURERS MAY BE SUBSTITUTED AS INDICATED IN THE SPECIFICATI0NS.
NUMBER
MANUFACTURER MODEL AND TYPE LOCATION
MIN. H.P. ELECT.
EXT. S.P.
(IN H 0)
DISCHARGE
TYPE CFM
MOTOR DATA
RPMDRIVE
CDP-36
OR
EQUAL
WALL
MOUNTED
HORIZONTAL 1/2 DIRECT 1150
208V
60Hz
FAN DATA
PROPELLER W/GEAR BOX GUARD,
MOUNTING PANEL AND
MOTORIZED DISCHARGE DAMPER
EF-1
PROPELLER
BAYLEY/
8,000 3/4
EXHAUST FAN SCHEDULE
OUTSIDE AIR FILTERS
ELECTRIC UNIT HEATER SCHEDULE
HVAC SCHEDULES
MXF-D-ASR-M010
f-d -a
NUMBER
MODEL AND TYPE LOCATION
SENSIBLE
ELECT. TYPE NUMBER
EXT. S.P.
(IN H 0)
INDOOR FAN DATA
AHU-1
DISCHARGE
TOTAL
TYPE CFM
RPM
208V
60Hz
NOMINAL INPUT
FILTER DATAMOTOR DATA
RPM
QTY.QTY.
COMPRESS. OUTDOOR FAN
ELECTRICAL DATA
AIR CONDITIONING UNIT SCHEDULE (NEW)
AHU-2
DISPOSABLE
FIBERGLASS
FOR RETURN
AIR ONLY
AMPS(IN.)
SIZEMANUF.
H.P.
MIN.
VERTICAL
ON
SUBBASE
0.8 1750 16X25X2
208V, 3O, 60HZ881 5143.9 242.0 8000
208V, 3O, 60HZ
RLA
LRASCROLL
VERTICAL
* OUTDOOR
SLAB
CU-1
CU-2
YORK
YORK
E6AAA3A
ND240C00
A2SLD2A
YD240C00
242.0
CURVE
FORWARD
AIR TEMPERATURE
@ 95° OUTSIDE
CAPACITY (MBH)
HEAD
PRESSURE
CONTROLS
COMPRESSOR
(GFM)
CONTROLLER
HVAC
WITH OAS 2.5
CONTROLS
ELECTRO-
FOR LOW
AMBIENT
OPERATION
DOWN TOCOMPLETE
SOLID
STATE
PACKAGE
SEQUENCING,
ANTI-SHORT
START,
SAFETY
LOCK OUT
-0° F
FAN OPERATION
AND MODULATING
CONTROL KIT
HEAD PRESSURE
WINTER
CYCLE,
20 TON UNIT
NONE
AMP
MCA
SIZE (AMP)
MAX FUSE
89.8 110
OUTLET (FLA)
POWER CONV.
10.0
H.P. FLA
INDOOR FAN
5 17.5
FLA
LRA 14.4
FLA 5
MOTOR
3/44 30.1
2. UNIT SHALL HAVE DUAL REFRIDGERANT CIRCUITS.
SOLENOID VALVES FOR CAPACITY REDUCTION.
1. AHU SHALL HAVE FACTORY MOUNTED LIQUID LINE
SEE NOTE 1
SEE NOTE 2
f-d -a
:1 lo tt e f-d -a
:1 lo tt e mxf-d-asr-m010
2020-06-18T15:36:05-0400
SUSHMA H PATEL
2020-06-17T14:56:28-0400
ALAIN P ALDAMA
f-d -a
:2 lo tt e
MXF-D-ASR-M011
f-d -a
1 2
ACU ACU
TURNING VANES18x20
LINED PLENUM
1" CONDENSATE DRAIN
(ROUTE ALONG WALL BETWEEN
TO THE OUTSIDE)
TURNING
VANES
ROOF
DECK
36"x 24" SUPPLY PLENUM
DAMPERS
REMOVAL & CLEANOUT (TYP)
ROOM T-STAT FOR
ACU-1 SET AT 75°F T-1
ROOM T-STAT FOR
ACU-2 SET AT 85°F
26"x 20"
ADM
CONCRETE SPLASH
BLOCK
(FOR CONDENSATE
DRAIN)
DM-2
AD
36" x20"
E/G ROOM AND MECH. EQ. ROOM
WALL SLEEVES (TYP)
3'W x15' L x1'-10" D
CONNECTION (TYP)
1" CONDENSATE DRAIN TRAP
WITH 2 UNIONS FOR
TO REMAIN
DUCT
FLOOR PLAN
26" x 20"
36"x 20"
EQUIPMENT ROOM ENGINE GENERATOR
13'-6"
M011
T-2
DRAIN
CONDENSATION
PIPING AND
(GFM)
OAS CONTROLLER
AC UNITS TO BE FULLY GROUNDED AND BONDED.13.
PROTECTION ASSOCIATION (NFPA) (SUBMITTAL REQUIRED)..
OPERATED IN ACCORDING WITH APPLICABLE CODE, INTERNATIONAL MECHANICAL CODE (IMC) AND NATIONAL FIRE
FURNISH AND INSTALL NEW SMOKE DETECTORS FOR EACH AHUS, INTERLOCKED WITH UNIT OPERATION, INSTALLED AND12.
AND NEC. ELECTRICAL WORK, INTERIOR,
FAA-C-1217G, GROUNDING, BONDING ,AND SHIELDING REQUIREMENTS FOR FACILITIES AND ELECTRONIC EQUIPMENT, LIGHTNING AND SURGE PROTECTION,ELECTRICAL WORK SHALL COMPLY WITH FAA ELECTRICAL STANDARD, FAA-STD-019E, 11.
OF THE FLEXIBLE CONDUIT.
COPPER CONDUCTOR. THE BONDING JUMPER SHALL TERMINATE ON FITTINGS LISTED FOR GROUNDING AT EACH END EQUIPMENT GROUNDING CONDUCTOR. THE BONDING JUMPER SHALL BE A 6 AWG GREEN-INSULATED STRANDED
ALL FLEXIBLE CONDUITS SHALL BE PROVIDED WITH AN EXTERNAL BONDING JUMPER IN ADDITION TO THE INTERNAL10.
FINAL 6 FEET OF CONDUIT CAN BE MADE WITH A U/L APPROVED FLEX CONDUIT AT EITHER ENDS.
FURNISH AND INSTALL 1-1/2” RIGID GALVANIZED STEEL CONDUIT FROM NEW CU-1 AND CU-2 TO DISCONNECT SWITCH. 9.
FOR CU-1 AND CU-2.
FURNISH AND INSTALL HEAVY DUTY, NEMA 4X STAINLESS STEEL, 100AMPS, 3 POLE, FUSED DISCONNECT SWITCHES8.
OTHER MISCELLANEOUS MANUFACTURER’S RECOMMENDATION C.
VARIABLE SPEED FAN MOTOR B.
HEAD PRESSURE CONTROL KIT (TRANSDUCER AND CONTROLLER) A.
INSTALLATION OF THE FOLLOWING:
MODULATION. EACH FAN / REFRIGERANT CIRCUIT SHALL BE MODIFIED WITH A FACTORY APPROVED FIELD
CONDENSING UNITS WILL BE FITTED WITH LOW AMBIENT CONTROLS, IN THE FORM OF CONDENSER FAN SPEED7.
EXPANSION BOLTS, WASHERS AND MACHINE SCREWS.
FIRMLY ANCHORED TO THE EXITING CONCRETE PAD WITH FULL-LENGTH METAL CHANNEL, APPROVED
CONDENSING UNITS SHALL BE INSTALLED WITH FACTORY APPROVED RUBBER ISOLATORS. UNITS SHALL BE 6.
AHU(S) SHALL BE CONNECTED TO THE EXISTING DUCTWORK WITH FLEX DUCT CONNECTIONS.5.
ISOLATORS, ANCHORED TO FLOOR WITH APPROVED EXPANSION BOLTS AND WASHERS AND MACHINE SCREWS.
FOR VIBRATION ISOLATION, AHU(S) SHALL BE FITTED WITH A FACTORY SUPPLIED SUBBASE AND STEEL SPRING4.
CONNECTIVITY AS NEEDED.
AHU(S) SHALL BE INTERLOCKED WITH NEW SUPPLY SIDE MOTOR DRIVEN ISOLATION DAMPER(S). PROVIDE POWER AND3.
DRAWING AND IN SPECIFICATIONS.
SYSTEM PERFORMANCE (COOLING CAPACITY, CFM, ELECTRICAL DATA, ETC) AS SCHEDULED OR AS REFERENCED ON2.
RELATIONSHIP CONTROLLED BY THE OAS 2.5 HVAC CONTROLLER, GOVERNMENT FURNISHED MATERIAL (GFM).
DRAWINGS AND SPECIFICATIONS. THE FINAL PRODUCT WILL BE TWO FULLY FUNCTIONING HVAC SYSTEMS IN A LEAD / LAG
FURNISH AND INSTALL NEW AHU-1, 2 AND CU-1, 2. UNITS SHALL BE INSTALLED AS PER MANUFACTURE’S RECOMMENDATIONS,1.
CONDENSING UNIT MOUNTING DETAILS
(2 TYP)
SWITCHES
DISCONNECT
ELECTRICAL
CANOPY SUPPORTS
TEMPORARY
NEW CONSTRUCTION PLAN
AND MACHINE SCREWS (TYP)
ANCHOR BOLTS, WASHERS
(4 TYP)
RUBBER ISOLATORS
FULL LENGTH METAL CHANNEL
(2 TYP)
CONDENSING UNITS
SPRING ISOLATORS
SUBBASE AND
REFRIDGERANT PIPING (TYP)
20"x 36"
ISOLATORS
30"24" 24" 3"
5'
3'
REFRIGERANT PIPING
REFRIGERANT PIPING
20"x 18" mxf-d-asr-m011
2020-06-18T15:36:55-0400
SUSHMA H PATEL
2020-06-17T14:57:12-0400
ALAIN P ALDAMA
f-d -a
:3 lo tt e
PULL BOX
OPENING
TO TOWER
4 - 2 1/2" CNDS.
O.H.
18"x 32"x 8"D
FAA CABLE JUNCTION BOX
B-10
EXIST DELAY LINE OVEN
EPA-21
EPA-22
ENGINE
VENTILATION
C-1
C-2
OAS 2.5 HVAC CONTROLLER
BE REMOVED IN ORDER TO INSTALL
EXISTING CONTROL ASSEMBLY TO
T(2 TYP)
REMOTE SENSOR
POWER
REUSE AS PRACTICAL FOR
TYPICAL CONTROL CONDUIT
PANEL-B
PANEL-D
PANEL-A
PANEL-C
M012
DETECTOR
SMOKE
Y2
Y1
DETECTOR
SMOKE
Y2
Y1
M012
TYPICAL CONTROL WIRING
SETPOINT
ROOM TEMP
ALARM: LIGHT AND AUDIBLE ALARM
ALARM: RED VISUAL
BOTH HVAC UNITS
CALL FOR OPERATION FOR
OF CONTROL POWER AND A
INDICATE THE PRESENCE
SYSTEM STATUS LIGHTS -
ALARM TONE
SILENCES THE AUDIBLE
IS IN ALARM, THIS BUTTON
WHEN THE CONTROLLER
AUDIBLE ALARM SILENCE
AN ALARM
RESETS THE CONTROLLER FROM
OVERTEMP RESET BUTTON
THE DESIRED ROOM TEMPERATURE
UNIT. SETPOINT INPUT FOR
CONTROL TO THE ACTIVE HVAC
THERMOSTAT (T1) - PROVIDES
ROOM TEMPERATURE CONTROL
SELECTION OF THE DESIRED PRIMARY
MANUAL CONTROL POINT FOR THE
PRIMARY UNIT SELECTOR SWITCH
SWITCHOVER
SETPOINT INPUT FOR THE OVERTEMP
ROOM OVERTEMP THERMOSTAT (T2)
SETTEMP
OVERTEMP
SILENCE
ALARM
RESET
M012 NOT TO SCALE
OAS QUICK REFERENCE
THE OAS, DAMAGE TO THE 24VAC TRANSFORMERS IN THE HVAC UNITS. AND/OR PERSONAL INJURY.
ELECTRICALLY ISOLATED FROM BOTH HVAC UNITS. FAILURE TO DO SO MAY CAUSE SPARKS, DAMAGE TO
: WHEN ATTACHING OR CHANGING WIRED CONNECTIONS WITHIN THE OAS, ENSURE POWER ISWARNING
CONTROLLER WILL BE THE 24VAC PROVIDED FROM THE HVAC UNITS.
DOES NOT REQUIRE A SEPARATE POWER CIRCUIT AND THE ONLY ENERGIZED POWER WITHIN THE ISOLATE POWER FROM THE CONTROLLER, EACH HVAC MUST BE ELECTRICALLY DISCONNECTED. THE OAS 9.THE OAS IS POWERED BY LOW VOLTAGE 24VAC, SUPPLIED BY THE ASSOCIATED HVAC UNITS. TO FULLY
OF CONNECTIONS AND A LENGTH NO GREATER THAT 6 FEET.
FLEXIBLE CONDUIT. LIQUID-TIGHT FLEXIBLE CONDUIT SHALL BE LIMITED TO THE FINAL POINT BETWEEN AHU AND CU SHALL BE RIGID TYPE 3/4” WITH THREADED CONNECTIONS OR LIQUID-TIGHT CONTAINED WITHIN CONDUITS. ANY OUTDOOR CONDUIT RUNS, BETWEEN CONTROLLER AND SYSTEM OR
8. ALL ASSOCIATED CONTROL WIRES RUN BETWEEN THE CONTROLLER AND HVAC UNITS SHALL BE
FOLLOWED.
7. ALL REQUIREMENTS OF THE MOST CURRENT REVISIONS OF FAA-STD-19 AND FAA·C-1217 SHALL BE
6. ELECTRICAL REQUIREMENTS:
NEC.
5. ALLOW FOR 3' OF CLEARANCE FROM THE FACE OF THE CONTROL BOX PER THE LATEST REVISION OF THE
GENERALLY VISIBLE WITHIN THE ASSOCIATED ROOM.
4. BUTTONS, THERMOSTATS AND SWITCHES SHALL BE ACCESSIBLE AND WARNING LIGHT SHALL BE
THE SENSOR AND OAS CONTROLLER.
WIRE ROUTING. ADDITION 3/4”EMT SHALL BE NEEDED TO REACH THE FINAL TERMINATION POINTS TO LAYOUT DETAIL. WITH APPROVAL, EXISTING RACEWAYS CAN BE USED FOR PORTION OF THE CONTROL TEMPERATURE SENSORS SHALL BE INSTALL FOR EACH OAS THERMOSTAT AS SHOWN ON CONTROLLER
3. SINCE SPACE IS NOT AVAILABLE FOR THE OAS IN THE PREFERRED LOCATION, SEPARATE REMOTE
VALIDATE ERMS DEVICE(S) TO THEIR ORIGINAL LOCATION OR WHERE INDICATED BY THE COR.
THE COR AND SERVICE OPERATING CENTER (SOC ). RE-MOUNT/ RE-INSTALL AND OPERATIONALLY CONTRACTOR MAY TEMPORARILY REMOVE, OR RELOCATE ERMS DEVICE(S) AFTER COORDINATING WITH EXISTING ENVIRONMENTAL REMOTE MONITORING SYSTEM (ERMS) DEVICE(S) SHALL REMAIN. THE
2. THE EXISTING CONTROL STATION SHALL BE REMOVED TO MAKE ROOM FOR THE OAS CONTROLLER, FOR ATTACHING THE BOX TO A SUPPORTING WALL OR STAND.
1. THE OAS IS CONTAINED WITHIN A 10"X16"X5" ELECTRICAL BOX. THE BOX CONTAINS MOUNTING HOLES
PHYSICAL INSTALLATION:
INSTALLATION:
SHUT DOWN THE AIR HANDLING UNIT.
CONTROLLED BY A RELAY (N.C. SUCH THAT DURING FIRE ALARM CONDITIONS THE RELAY SHALL OPEN TO
6. (ADJUSTABLE) TIME DELAY TO PREVENT SHORT-CYCLING CHANGE OVERS. THE POWER CIRCUIT SHALL BE
. STANDBY SYSTEM SHALL BE ACTIVATED. THE CHANGE-OVER CONTROL SHALL HAVE A ONE HOUR TEMPERATURE EXCEEDS 80'F (ADJUSTABLE), THE PRIMARY SYSTEM SHALL BE SHUT DOWN AND THE
5. YEAR ROUND. THERMOSTAT T1 SHALL ACTIVATE COOLING ABOVE 75'F. (ADJUSTABLE). IF THE
OPENED.
DE-ENERGIZING OF AHU(S). AHU FANS SHALL NOT BE ENERGIZED UNTIL ISOLATION DAMPERS ARE FULL
4. ASSOCIATED ISOLATION DAMPER SHALL OPEN OR CLOSE IN COORDINATION WITH THE ENERGIZING AND
START UP.
3. IF THE PRIMARY SYSTEM SHUTS DOWN, FOR ANY REASON, THE STANDBY SYSTEM SHALL AUTOMATICALLY
2. ONLY ONE HVAC SYSTEM SHALL OPERATE AT ANY GIVEN TIME, WITH THE SECOND SYSTEM AS A STAND-BY.
ERMS COMPATIBILITY L.
EASE OF USE AND REPAIR ABILITY K.
COMMERCIALLY AVAILABLE REPLACEMENT PARTS J.
SIMPLIFIED TROUBLESHOOTING I.
AUDIBLE ALARM SILENCE H.
AUDIBLE AND VISUAL ALARMS G.
SYSTEM STATUS LIGHTS F.
MANUAL OVER-RIDE SWITCH E.
AUTOMATIC UNIT SWITCH OVER D.
ADJUSTABLE SET POINTS C.
PRIMARY UNIT SELECTION B.
REDUNDANT CONTROL OF 2 HVAC UNITS A.
SOME OF THESE FEATURES ARE LISTED BELOW:
CONTROL SYSTEM WHICH CAPTURES SPECIFIC OPERATIONAL CRITERIA IMPORTANT TO NAS EQUIPMENT.
FACILITIES THAT REQUIRE RELIABLE REDUNDANT HVAC CONTROL. THE OAS IS A SIMPLE YET ROBUST
1. THE OAS 2.5 HVAC CONTROLLER (GFM) IS A FAA DESIGNED HVAC CONTROLLER FOR USE AT CRITICAL FAA
SEQUENCE OF OPERATION / HVAC CONTROLLER
CONTROLLER LAYOUT
UNDERGROUND
4-3 1/2" CNDS.
CONTROL SYSTEM
MXF-D-ASR-M012
f-d -a
T-1 REMOTE SENSOR
T-2 REMOTE SENSOR
AHU-1 AHU-2
OAS 2.5
HVAC CONTROLLER
mxf-d-asr-m012
2020-06-18T15:38:04-0400
SUSHMA H PATEL
2020-06-17T14:59:57-0400
ALAIN P ALDAMA