Electric Panels.docx
DOCX document 18 KB Posted
- Attached to
- NYSSD Electrical Panel Replacement
- Solicitation number
- 2139819
- Issued by
- Oneida County, New York
About this file
This file is a detailed inventory document of electrical panels located within buildings operated by New York State School District (NYSSD) facilities, specifically supporting the NYSSD Electrical Panel Replacement contract opportunity. The document catalogues 25 electrical panels across multiple buildings and floors, including Buildings 11A, 11B, and Building 16, with comprehensive specifications for each panel such as Federal Pacific or General Electric manufacturer identification numbers, amperage ratings, voltage specifications, feeder sizes, and main breaker capacities. The panels are distributed across basement, first floor, and second floor locations throughout the facilities, with voltage systems ranging from 120/208V to 277/480V and amperage capacities from 100 amps to 400 amps. The associated contract opportunity requires replacement of these 25 three-phase electrical panels with new General Electric AQ type panels, demolition of existing panels, reuse of existing feeders and branch circuits, repair of any brick work on flush mount panels, and reconnection of all existing feeders and branch circuits to the new installations.
The project scope includes comprehensive testing, commissioning, and turnover procedures encompassing electrical panel testing, installation verification, pre-energization inspection, electrical testing, functional testing and commissioning, code and safety compliance verification, preventative maintenance prior to turnover, closeout documentation, owner training, and final acceptance with field verification required. The contract opportunity carries no specific disadvantaged business enterprise (DBE), minority business enterprise (MBE), women business enterprise (WBE), or service-disabled veteran-owned business (SDVOB) contracting goals, with all such percentages set at zero. Additionally, there are no identified incumbent businesses with identical or substantially similar procurement contracts awarded within the past five years.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Request For Quote Form Electric panels .doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electric Panels:
11A 1st Floor:
* -LP1F Hallway outside room 1-29: 250 MCM feeder Federal Pacific No: AJ-867275 Type: NBLP 100 Amps, 240/max Volts, 3phase, 4 wire 90amp main breaker installed
* -LP1E Hallway outside 1-36 (elevator mech. Rm.): 250 MCM feeder Federal Pacific No: AK-317353 Type: NBLP 100 Amp, 240/max volts, 3 phase, 4 wire
11A 2nd Floor:
* LP2D-Left when facing- Hallway across from room 2-6 Federal Pacific No: AK-317871 Type: NBLP 225 Amp 240/max Volts, 3phase, 4 wire 175amp main breaker installed
* LP2D-right when facing- Hallway across from room 2-6 Federal Pacific No: AK-317872 Type: NBLP 225 Amp 240/max Volts, 3 Phase, 4 wire
* LP-2E – Hallway outside Room 2-15: 250MCM feeder Federal Pacific No: AJ-867354 Type: NBLP 100 amp 240/max volts, 3 phase, 4 wire 90 Amp main breaker installed
11B 1st Floor:
* LP-1D – Hallway 1-123 1/0 feeder Federal Pacific AK-317122 225 Amp 240v/max 3phase 4 wire Type NBLP 125 Amp Main installed
* PP-1C Left – Hallway 1-123 3/0 Feeder Federal Pacific AK-317202 Type: NDP 225 Amps 120/208v 3phase 4 wire 150 Main installed
* PP-1C Right – Hallway 1-123 3/0 feeder Federal Pacific AK-317203 Type NDP 225 Amps 120/208V 3Phase 4 wire
| * | LP-1B | - Room 1-42A – 1/0 feeder |
| Federal Pacific AK-317159 | Type: NDP |
100Amps 120/208V 3ph 4 wire 70Amp Main installed
* LP-1C – Room 1-118- 1/0 Feeders Maybe Federal Pacific?
200Amp 120/208V 3phase
* PP-1A – Room 1-64A Stores Clerk Storage – 1/0 feeder Maybe Federal Pacific?
* PP-1B Left – Kitchen room 1-48 – 3/0 Feeder Federal Pacific AK-317241 Type: NDP 225 Amps 120/208V 3Phase 4 wire
| * | PP-1B Right – Kitchen room 1-48 – 3/0 Feeder |
| Federal Pacific AK-317205? | Type: NDP |
225 Amps 120/208V 3Phase 4 wire 175 Main installed
* Panel Behind PP-1B in Kitchen Room 1-49 Make?
200amp main installed
* LP-1A – Cafeteria closet between 1-76 and 1-69 – 1/0 Feeder Federal Pacific AK-317131 Type: NBLP 225Amp 240V/Max 3Phase 4 wire 125 Main installed
11B 2nd Floor:
* LP-2C – Hallway 2-70 outside room 2-41 – 1/0 Feeders Federal Pacific AJ-B67353 Type: NBLP 100Amps 240V/Max 3Ph 4 wire 100Amp Main Installed
* LP-2A – Hallway 2-70 outside room 2-47 – 2/0 feeders Federal Pacific AK-317066 Type: NBLP 225amps 240v/max 3phase 4 wire 125amp main installed
* PP-2A – Hallway 2-69 outside room 2-57 – 500MCM feeder Federal Pacific AK-317264 Type: NDP 225Amp 120/208V 3phase 4 wire 150Amp main installed
* LP-2B – Hallway 2-36 outside room 2-31 – 1/0 feeder Federal Pacific AK-317329 Type: NBLP 100 Amp 240v/max 3 phase 4 wire 100amp main installed
* Stage Lighting – Room 2-34 Major Specialized Lighting Control Equipment 175 amp 120/208V 3Phase
11B Basement:
| * | PP-BB Left – Basement B-2 by pumps- 3/0 feeders |
| Federal Pacific AK- 317316 | Type: NDP |
400amps 120/208V 3Phase 4 wire 300amp main installed
| * | PP-BB Right – Basement B-2 by pumps – Parallel 3/0 feeders |
| Federal Pacific AK-317315 | Type: NDP |
400amps 120/208V 3Phase 4 wire
* PP-BC – Basement B-4 by boilers – feeders ?
Federal Pacific AJ-868161 Type: NHDP 400amp 277/480v ?? 3phase 4 wire 400 amp main installed
* LP-BA- Basement B-7 – 4/0 feeder Federal Pacific AK-317624 Type: NBLP 100amp 240v/max 70amp main installed
Building 16 Basement:
* PP-BB – Basement B-20 – Feeder 1/10?? Feeder General Electric Type: NAB Style: 2 120/208V 3 Phase 150amp main installed