Report__Bridge_Inspection_4780-015P.pdf
PDF 4 MB Posted
- Attached to
- New River Gorge National River Federal contract opportunity
- Solicitation number
- DTFH71-17-B-00010
About this file
Report_ Bridge Inspection_4780-015P
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Results_of_Bid_Opening_Schedule_A&B_-_NP-NERI_BMS(1).pdf | ||
| Report_NEPA_CE.pdf | ||
| Report__Bridge_Inspection_4780-002P.pdf | ||
| ADV_Bidder's_Qualifications_Form.doc | DOC document | |
| VETS-4212_-_Form.pdf | ||
| IFB_Solicitation_-_NP-NERI_BMS(1).pdf | ||
| Report__Bridge_Inspection_4780-001P.pdf | ||
| Plans_-_NP_NERI_BMS_(1).pdf | ||
| FP14_Eng.pdf | ||
| Report__Bridge_Inspection_4780-003P.pdf | ||
| Synopsis_-_NP_NERI_BMS(1).doc | DOC document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRIDGE INSPECTION REPORT
UPPER GLADE BRIDGE
SCOTT BRANCH ROAD OVER GLADE/PINCH CREEK
NEW RIVER GORGE NATIONAL RIVER
LW
STRUCTURE NO. 4780-015P
INSPECTION TYPE:
INSPECTION DATE: 11/19/15
Report prepared by: ND
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 4780-015P
UPPER GLADE BRIDGE INSPECTION DATE: 11/19/15
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: .. 66.3 FT (20.2 M)
DECK TYPE: ......................... WOOD OR TIMBER MAX. SPAN LENGTH: .......... 64.4 FT (19.6 M)
WEARING SURFACE: .......... WOOD OR TIMBER DECK WIDTH: ...................... 12.1 FT (3.7 M)
ABUT. FOUNDATIONS: ........ UNKNOWN CURB TO CURB WIDTH: ..... 11.2 FT (3.4 M)
PIER FOUNDATION(S): ........ N/A YEAR BUILT: ........................ 1960 (EST.)
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... 0000 / NONE SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 4 - PRIMITIVE FRACTURE CRITICAL: ........ NO
STRUCTURE HISTORY: ...... Flood event in 2010 washed out east embankment. Approach was reconstructed and wingwall were added to abutments in 2013.
LOCATION
NEW RIVER GORGE NATIONAL RIVER
STATE: ................................. WEST VIRGINIA
FACILITY CARRIED: ............ SCOTT BRANCH ROAD
FEATURE INTERSECTED: .. GLADE/PINCH CREEK
MILE POINT: ..................... 2.00 (KM PT 3.22)
LOCATION: I-64 EXIT 129A SOUTH TOWARD SANDY
SPRING.(N37 45 52.6 W81 04 15.3) PASS SHELL
STATION ON RT, EXXON ON LT, TURN LEFT AT 1ST
ROAD AFTER TWO SHARP CURVES ACROSS FROM
STRUCTURE EVALUATION SUMMARY
This steel beam bridge is in poor to fair condition overall. The main problem with this structure is ongoing severe deterioration of the timber runners that span over the deck timbers. Some timber runners have been replaced in response to emergency repairs recommended in the previous inspection report; however, several decay holes remain in other timber runners and deck planks. Other problems include paint deterioration and corrosion of the structural steel.
Corrective measures should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future. It should be noted that this bridge is scheduled for rehabilitation in the near future under Project NP NERI BMS(1). The scope of work includes cleaning and painting of the structural steel, and replacement of the deck, curbs, and runners.
INSPECTION TEAM: C. CASTRO, R. SILVESTRY
CONDITION ASSESSMENT:
CARLOS CASTRO, P.E., FIELD TEAM LEADER 571-434-1546
REPORT REVIEW:
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 3/14/16
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 4780-015P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
B226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
59.2,6,7 CLEAN AND PAINT ALL STRUCTURAL STEEL. 1 LS $0
58 REPLACE TIMBER DECK, RUNNERS, AND CURBS 1 LS $0
58, 59 CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND
DESIGN AND CONSTRUCTION ENGINEERING (APPROXIMATELY70%
TOTAL REHAB COST), PLUS PARK LOCATION FACTOR.
1 LS $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ..
TOTAL ITEMIZED COSTS:
$0
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 4780-015P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK
ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
G F N N N F F N G
N G
P P G N F N
N
N
G
P
58.1,3 MINOR CHECKING OF 12" X 12" TRANSVERSE DECK TIMBERS AND 3"
X 8" TIMBER DECK RUNNERS.
SPACES (UP TO 2' WIDE) EXIST BETWEEN DECK TIMBERS; SEVERE
DECAY OF TIMBER RUNNERS HAS LEFT FULL-DEPTH HOLES IN
DECK SYSTEM. DEBRIS ACCUMULATION ON DECK SURFACE,
BETWEEN RUNNERS, AND ALONG CURBS.
58.6, 36.A NO RAILING SYSTEM ON STRUCTURE. BROKEN SOUTH TIMBER
CURB AT ANCHORAGE.
58.7 NO SPACERS BLOCKS BELOW TIMBER CURBS TO ALLOW FOR
DECK DRAINAGE.
59.2,6,7 MINOR TO MODERATE PAINT DETERIORATION AND RUSTING OF
STEEL BEAMS AND LATERAL BRACING. PITTING AND SCALING OF
ALL STEEL MEMBERS. BEAM #1 WEB STIFFENER AT CROSS FRAME
CONNECTION HAS IMPACT TEAR (POSSIBLY PRE-EXISTING OR
FROM CONSTRUCTION). MINOR SOIL DEPOSIT ON BOTTOM AND
TOP FLANGES, MODERATE AT BOTTOM OF VERTICAL STIFFENERS.
60.1,4,6,9 NEW CONCRETE WINGWALLS AT EACH CORNER OF OLD
CONCRETE ABUTMENT. MINOR VERTICAL CRACKS WITH
EFFLORESCENCE BELOW WEEP HOLES AT WINGWALLS.
ENGINEERED RIPRAP LOCATED AT ALL WINGWALLS.
60.3 MINOR TO MODERATE RUSTING AND SECTION LOSS ON STEEL
PLATE BEARING AT SOUTH BEARING OF EAST ABUTMENT (NO
POSSIBLE TO VERIFY ON THIS INSPECTION). MINOR
ACCUMULATION OF DEBRIS ON BEARING SEATS.
BREASTWALLS OR COLUMNS1. G
PILE BENTS2. N
CAPS AND/OR BEARING SEATS3. G
BACKWALLS AND/OR BULKHEADS4. G
FOUNDATIONS5. N
WINGWALLS6. N
WEEP HOLES7. N
EXPANSION JOINTS8. N
EROSION AND/OR SCOUR9. G
SETTLEMENT OR DEFLECTION10. G
SLOPE PROTECTION11. N
OTHER 12. N
PIER(S)
WALLS AND/OR COLUMNS 13. N
PILE BENTS14. N
CAPS AND/OR BEARING SEATS15. N
FOUNDATIONS16. N
EROSION AND/OR SCOUR17. N
SETTLEMENT OR DEFLECTION18. N
OTHER 19. N
FIELD INSPECTION REPORT STRUCTURE NO. 4780-015P
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL 7
G G N G N
MED
INSUFF
60 FT.
61.2,6 STRUCTURE HAS BEEN OVERTOPPED DUE TO RELEASE OF WATER
FROM RESERVOR UPSTREAM. A FLOOD EVENT IN 2010 WASHED
AWAY EAST ABUTMENT EMBANKMENT AND OLD ABUTMENT
UPSTREAM OF STRUCTURE.
222.6 POTHOLES WITH STANDING WATER AT EAST AND WEST
APPROACHES.
ROCK
222. APPROACHES 6
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1. N
N N G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. 0
N N N
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
STRUCTURE LOAD RATING STRUCTURE NO. 4780-015P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 20 18 33 30
HS 25 23 42 38
TYPE 3 24 22 40 36
TYPE 3S2 32 29 54 49
TYPE 3-3 39 35 65 59
DESIGN LOADING: UNKNOWN (H20 ASSUMED - SEE REMARKS)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: DESIGN LOADING IS UNKNOWN; ASSUMPTION IS BASED ON STRUCTURE TYPE, LOCATION, AGE, AND
CONDITION.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 4780-015P
STRUCTURE IDENTIFICATION
(201) PARK: NEW RIVER GORGE NATIONAL RIVER (1) STATE: ....................................... 543 - WEST VIRGINIA (WV)
(202) STRUCTURE NAME: .......... UPPER GLADE BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 089 - SUMMERS
(204) STRUCTURE NUMBER: ..... 4780-015P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 3 - NORTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 0 (6) FEATURES INTERSECTED:....... GLADE/PINCH CREEK
(207) ROAD SECTION NO: .......... 015P (7) FACILITY CARRIED: .................. SCOTT BRANCH ROAD
(208) NPS ROAD CLASS: ............ 4 - PRIMITIVE (8) STATE STRUCTURE NO: .......... 4780015P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ I-64 EXIT 129A SOUTH TOWA
(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 0000 (11) MILE POINT: ............................. 2.00 (KM PT 3.22)
(212) DRAWING NUMBERS: ....... NONE (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
3 - STEEL
02 - STRINGER/MULTI-BEAM or GIRDER
64.4 FT (19.6 M)
66.3 FT (20.2 M)
0 - UNKNOWN
0 - UNKNOWN
6 - N/A
6 - N/A
8 - WOOD OR TIMBER
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 7 - WOOD OR TIMBER
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... NO
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 25.2 TONS (22.9 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 42.1 TONS (38.2 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 11/15 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 4780-015P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 37°45'52.00" (51) CURB TO CURB WIDTH: ........... 11.2 FT (3.4 M)
(17) LONGITUDE: ......................... 81°02'36.50" (52) DECK WIDTH: ............................ 12.1 FT (3.7 M)
(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH: ........ 12.1 FT (3.7 M)
(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH: ..... 11.2 FT (3.4 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 0.0 FT (0.0 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 0.0 FT (0.0 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 15 (34) SKEW ANGLE: ............................ 0 °
(30) YEAR OF ADT: ...................... 2013 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 18 (47) TOTAL HORIZ. CLEARANCE: .... 11.2 FT (3.4 M)
(115) YEAR OF FUTURE ADT: ..... 2033 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... N RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A
(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 0 - N/A
DESIGN TYPE: ........................ 0 - N/A
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 0.00 FT (0.00 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 0NNN
(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB
(75B) WORK DONE BY: ............. 1 - CONTRACT
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
8 - Stable; scour above top of fo
3 - CONSTRUCTION
B - MAJOR
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
Flood event in 2010 washed out east embankment. Approach was reconstructed and wingwall were added to abutments in 2013.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:81�02'36.50 http:37�45'52.00
APPENDIX STRUCTURE NO. 4780-015P
PHOTOGRAPHS STRUCTURE NO. 4780-015P
PHOTO #1 - LOOKING EAST TOWARD TRAIL PARKING
FLOW
PHOTO #2 - SOUTH (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING WEST; NOTE SOME
RECENTLY REPLACED TIMBER RUNNERS, AND OTHERS EXHIBITING
ADVANCED DECAY
PHOTO #4 - POTHOLES AND WATER PONDING ON EAST APPROACH
PHOTO #5 - DECAY AND FULL SECTION LOSS
OF TIMBER RUNNER NEAR SOUTH CURBLINE
PHOTO #6 - DECAY OF TIMBER RUNNERS AT
VARIOUS LOCATIONS
PHOTO #7 - DECAY OF TIMBER RUNNER AT
NORTHEAST CORNER; NOTE ALSO TYPICAL
SOIL ACCUMULATION ALONG CURBS
PHOTO #8 - BROKEN SOUTH TIMBER CURB AT
ANCHORAGE
PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING EAST, NOTE
TYPICAL PAINT DETERIORATION AND RUSTING OF STRUCTURAL
STEEL
PHOTO #10 - CLOSE UP OF A STEEL GIRDER; NOTE PEELING OF PAINT
AND MINOR RUSTING
PHOTO #11 - LOOSE ANCHOR BOLT CONNECTING TIMBER DECK
PLANK TO TOP FLANGE OF BEAM AT SOUTHEAST CORNER
PHOTO #12 - HORIZONTAL TEAR ON INSIDE VERTICAL STIFFENER FOR
BEAM #1 NEAR EAST END
PHOTO #13 - TYPICAL RUSTING OF BEARING PLATES, BEARING PLATE
AT EAST END OF SOUTH EXTERIOR BEAM SHOWN; NOTE DEBRIS ON
BEARING SEATS
PHOTO #14 - GENERAL VIEW OF WEST ABUTMENT
PHOTO #15 - CRACKING AND STAINING ON NORTH SIDE OF WEST
ABUTMENT BACKWALL; NOTE FALLEN PIECE OF TIMBER
PHOTO #16 - CRACKING WITH EFFLORESCENCE ON SOUTH SIDE OF
WEST ABUTMENT BACKWALL
PHOTO #17 - GENERAL VIEW OF EAST ABUTMENT
PHOTO #18 - DIAGONAL CRACK AT SOUTH END OF EAST ABUTMENT
BACKWALL (PHOTO FROM 11/8/13 INSPECTION)
PHOTO #19 - GENERAL VIEW OF NORTHEAST WINGWALL; NOTE
CRACKS WITH EFFLORESCENCE BELOW WEEP HOLES
PHOTO #20 - LOOKING UPSTREAM FROM STRUCTURE
PHOTO #21 - LOOKING DOWNSTREAM FROM STRUCTURE