Report__Bridge_Inspection_4780-015P.pdf

PDF 4 MB Posted

Attached to
New River Gorge National River Federal contract opportunity
Solicitation number
DTFH71-17-B-00010
Issued by
Department of Transportation Federal Highway Administration

About this file

Report_ Bridge Inspection_4780-015P

View the file

Other files for this federal contract opportunity

Other files attached to New River Gorge National River, newest first.
File Type Posted
Results_of_Bid_Opening_Schedule_A&B_-_NP-NERI_BMS(1).pdf PDF
Report_NEPA_CE.pdf PDF
Report__Bridge_Inspection_4780-002P.pdf PDF
ADV_Bidder's_Qualifications_Form.doc DOC document
VETS-4212_-_Form.pdf PDF
IFB_Solicitation_-_NP-NERI_BMS(1).pdf PDF
Report__Bridge_Inspection_4780-001P.pdf PDF
Plans_-_NP_NERI_BMS_(1).pdf PDF
FP14_Eng.pdf PDF
Report__Bridge_Inspection_4780-003P.pdf PDF
Synopsis_-_NP_NERI_BMS(1).doc DOC document
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

UPPER GLADE BRIDGE

SCOTT BRANCH ROAD OVER GLADE/PINCH CREEK

NEW RIVER GORGE NATIONAL RIVER

LW

STRUCTURE NO. 4780-015P

INSPECTION TYPE:

INSPECTION DATE: 11/19/15

Report prepared by: ND

Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov

STRUCTURE SUMMARY STRUCTURE NO. 4780-015P

UPPER GLADE BRIDGE INSPECTION DATE: 11/19/15

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... STEEL NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: .. 66.3 FT (20.2 M)

DECK TYPE: ......................... WOOD OR TIMBER MAX. SPAN LENGTH: .......... 64.4 FT (19.6 M)

WEARING SURFACE: .......... WOOD OR TIMBER DECK WIDTH: ...................... 12.1 FT (3.7 M)

ABUT. FOUNDATIONS: ........ UNKNOWN CURB TO CURB WIDTH: ..... 11.2 FT (3.4 M)

PIER FOUNDATION(S): ........ N/A YEAR BUILT: ........................ 1960 (EST.)

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A

PROJ./PLAN REF. NO: ......... 0000 / NONE SKEW ANGLE: ..................... 0 °

NPS ROAD CLASS: .............. 4 - PRIMITIVE FRACTURE CRITICAL: ........ NO

STRUCTURE HISTORY: ...... Flood event in 2010 washed out east embankment. Approach was reconstructed and wingwall were added to abutments in 2013.

LOCATION

NEW RIVER GORGE NATIONAL RIVER

STATE: ................................. WEST VIRGINIA

FACILITY CARRIED: ............ SCOTT BRANCH ROAD

FEATURE INTERSECTED: .. GLADE/PINCH CREEK

MILE POINT: ..................... 2.00 (KM PT 3.22)

LOCATION: I-64 EXIT 129A SOUTH TOWARD SANDY

SPRING.(N37 45 52.6 W81 04 15.3) PASS SHELL

STATION ON RT, EXXON ON LT, TURN LEFT AT 1ST

ROAD AFTER TWO SHARP CURVES ACROSS FROM

STRUCTURE EVALUATION SUMMARY

This steel beam bridge is in poor to fair condition overall. The main problem with this structure is ongoing severe deterioration of the timber runners that span over the deck timbers. Some timber runners have been replaced in response to emergency repairs recommended in the previous inspection report; however, several decay holes remain in other timber runners and deck planks. Other problems include paint deterioration and corrosion of the structural steel.

Corrective measures should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future. It should be noted that this bridge is scheduled for rehabilitation in the near future under Project NP NERI BMS(1). The scope of work includes cleaning and painting of the structural steel, and replacement of the deck, curbs, and runners.

INSPECTION TEAM: C. CASTRO, R. SILVESTRY

CONDITION ASSESSMENT:

CARLOS CASTRO, P.E., FIELD TEAM LEADER 571-434-1546

REPORT REVIEW:

MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252

REPORT APPROVAL: DATE: 3/14/16

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 4780-015P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

B226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

59.2,6,7 CLEAN AND PAINT ALL STRUCTURAL STEEL. 1 LS $0

58 REPLACE TIMBER DECK, RUNNERS, AND CURBS 1 LS $0

58, 59 CONTRACT COSTS FOR MOBILIZATION, TRAFFIC CONTROL, AND

DESIGN AND CONSTRUCTION ENGINEERING (APPROXIMATELY70%

TOTAL REHAB COST), PLUS PARK LOCATION FACTOR.

1 LS $0

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIM. RECONSTRUCTION TOTAL: ..

TOTAL ITEMIZED COSTS:

$0

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that the recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 4780-015P

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

N

58. DECK

ITEM REFERENCE AND REMARKS

OTHER

ALIGNMENT

DEFLECTION AND/OR VIBRATION

FASCIA(E)

DIAPHRAGMS AND BRACING

TRUSSES

FLOOR BEAMS AND STRINGERS

ARCH(ES) OR SLAB(S)

GIRDERS OR BEAMS

BEARING DEVICES

59. SUPERSTRUCTURE

OTHER

DEFLECTION AND/OR VIBRATION

UTILITIES

DRAINS AND DRAINAGE

PARAPETS AND/OR RAILINGS

CURBS, SIDEWALKS, AND MEDIAN

RIDEABILITY

WEARING SURFACE

EXPANSION JOINTS

DECK SLAB

ABUTMENTS

60. SUBSTRUCTURE

1.

10.

2.

3.

4.

5.

6.

7.

8.

9.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

PAINT

11.

G F N N N F F N G

N G

P P G N F N

N

N

G

P

58.1,3 MINOR CHECKING OF 12" X 12" TRANSVERSE DECK TIMBERS AND 3"

X 8" TIMBER DECK RUNNERS.

SPACES (UP TO 2' WIDE) EXIST BETWEEN DECK TIMBERS; SEVERE

DECAY OF TIMBER RUNNERS HAS LEFT FULL-DEPTH HOLES IN

DECK SYSTEM. DEBRIS ACCUMULATION ON DECK SURFACE,

BETWEEN RUNNERS, AND ALONG CURBS.

58.6, 36.A NO RAILING SYSTEM ON STRUCTURE. BROKEN SOUTH TIMBER

CURB AT ANCHORAGE.

58.7 NO SPACERS BLOCKS BELOW TIMBER CURBS TO ALLOW FOR

DECK DRAINAGE.

59.2,6,7 MINOR TO MODERATE PAINT DETERIORATION AND RUSTING OF

STEEL BEAMS AND LATERAL BRACING. PITTING AND SCALING OF

ALL STEEL MEMBERS. BEAM #1 WEB STIFFENER AT CROSS FRAME

CONNECTION HAS IMPACT TEAR (POSSIBLY PRE-EXISTING OR

FROM CONSTRUCTION). MINOR SOIL DEPOSIT ON BOTTOM AND

TOP FLANGES, MODERATE AT BOTTOM OF VERTICAL STIFFENERS.

60.1,4,6,9 NEW CONCRETE WINGWALLS AT EACH CORNER OF OLD

CONCRETE ABUTMENT. MINOR VERTICAL CRACKS WITH

EFFLORESCENCE BELOW WEEP HOLES AT WINGWALLS.

ENGINEERED RIPRAP LOCATED AT ALL WINGWALLS.

60.3 MINOR TO MODERATE RUSTING AND SECTION LOSS ON STEEL

PLATE BEARING AT SOUTH BEARING OF EAST ABUTMENT (NO

POSSIBLE TO VERIFY ON THIS INSPECTION). MINOR

ACCUMULATION OF DEBRIS ON BEARING SEATS.

BREASTWALLS OR COLUMNS1. G

PILE BENTS2. N

CAPS AND/OR BEARING SEATS3. G

BACKWALLS AND/OR BULKHEADS4. G

FOUNDATIONS5. N

WINGWALLS6. N

WEEP HOLES7. N

EXPANSION JOINTS8. N

EROSION AND/OR SCOUR9. G

SETTLEMENT OR DEFLECTION10. G

SLOPE PROTECTION11. N

OTHER 12. N

PIER(S)

WALLS AND/OR COLUMNS 13. N

PILE BENTS14. N

CAPS AND/OR BEARING SEATS15. N

FOUNDATIONS16. N

EROSION AND/OR SCOUR17. N

SETTLEMENT OR DEFLECTION18. N

OTHER 19. N

FIELD INSPECTION REPORT STRUCTURE NO. 4780-015P

ITEM REFERENCE AND REMARKS

STREAM BED COMPOSITION : 9.

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION3.

EROSION AND/OR SCOUR2.

ALIGNMENT1.

61. CHANNEL 7

G G N G N

MED

INSUFF

60 FT.

61.2,6 STRUCTURE HAS BEEN OVERTOPPED DUE TO RELEASE OF WATER

FROM RESERVOR UPSTREAM. A FLOOD EVENT IN 2010 WASHED

AWAY EAST ABUTMENT EMBANKMENT AND OLD ABUTMENT

UPSTREAM OF STRUCTURE.

222.6 POTHOLES WITH STANDING WATER AT EAST AND WEST

APPROACHES.

ROCK

222. APPROACHES 6

OTHER 9.

ALIGNMENT 8.

SIGNS7.

SETTLEMENT 6.

EROSION5.

SURFACING4.

APPROACH GUARDRAIL 3.

2. RELIEF JOINTS

APPROACH SLABS1. N

N N G G G N G N

223. RETAINING WALL N

OTHER 6.

SETTLEMENT OR DEFLECTION5.

EROSION AND/OR SCOUR4.

FOUNDATION3.

WEEP HOLES2.

1. WALL

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDSD.

APPROACH GUARDRAILSC.

TRANSITIONSB.

BRIDGE RAILINGSA. 0

N N N

TRAFFIC SAFETY RATING CODES

N

Does not meet standards or a safety feature is required and none is provided.

Meets currently acceptable standards.

Not applicable or a safety feature is not required.

STRUCTURE LOAD RATING STRUCTURE NO. 4780-015P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 20 18 33 30

HS 25 23 42 38

TYPE 3 24 22 40 36

TYPE 3S2 32 29 54 49

TYPE 3-3 39 35 65 59

DESIGN LOADING: UNKNOWN (H20 ASSUMED - SEE REMARKS)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: DESIGN LOADING IS UNKNOWN; ASSUMPTION IS BASED ON STRUCTURE TYPE, LOCATION, AGE, AND

CONDITION.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 4780-015P

STRUCTURE IDENTIFICATION

(201) PARK: NEW RIVER GORGE NATIONAL RIVER (1) STATE: ....................................... 543 - WEST VIRGINIA (WV)

(202) STRUCTURE NAME: .......... UPPER GLADE BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 089 - SUMMERS

(204) STRUCTURE NUMBER: ..... 4780-015P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 3 - NORTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 0 (6) FEATURES INTERSECTED:....... GLADE/PINCH CREEK

(207) ROAD SECTION NO: .......... 015P (7) FACILITY CARRIED: .................. SCOTT BRANCH ROAD

(208) NPS ROAD CLASS: ............ 4 - PRIMITIVE (8) STATE STRUCTURE NO: .......... 4780015P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ I-64 EXIT 129A SOUTH TOWA

(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 0000 (11) MILE POINT: ............................. 2.00 (KM PT 3.22)

(212) DRAWING NUMBERS: ....... NONE (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

3 - STEEL

02 - STRINGER/MULTI-BEAM or GIRDER

64.4 FT (19.6 M)

66.3 FT (20.2 M)

0 - UNKNOWN

0 - UNKNOWN

6 - N/A

6 - N/A

8 - WOOD OR TIMBER

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 7 - WOOD OR TIMBER

B) TYPE MEMBRANE: ................. 0 - NONE

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... NO

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 25.2 TONS (22.9 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 42.1 TONS (38.2 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 11/15 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 4780-015P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE: ............................. 37°45'52.00" (51) CURB TO CURB WIDTH: ........... 11.2 FT (3.4 M)

(17) LONGITUDE: ......................... 81°02'36.50" (52) DECK WIDTH: ............................ 12.1 FT (3.7 M)

(19) DETOUR LENGTH: ............... 0 MI (0 KM) (32) APPR. ROADWAY WIDTH: ........ 12.1 FT (3.7 M)

(28A) LANES ON STRUCT: .......... 01 (213) APPR. PAVEMENT WIDTH: ..... 11.2 FT (3.4 M)

(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 0.0 FT (0.0 M)

(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 0.0 FT (0.0 M)

(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN

(29) AVG. DAILY TRAFFIC: .......... 15 (34) SKEW ANGLE: ............................ 0 °

(30) YEAR OF ADT: ...................... 2013 (35) DECK FLARE?: ........................... NO

(114) FUTURE ADT: ..................... 18 (47) TOTAL HORIZ. CLEARANCE: .... 11.2 FT (3.4 M)

(115) YEAR OF FUTURE ADT: ..... 2033 (50) SIDEWALKS:

(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)

(38) NAVIGATION CONTROL?: ... N RIGHT : ................................... 0.0 FT (0.0 M)

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A

(111) ABUT. OR PIER PROT: ....... 1 - NAV PROTECTION NOT REQUIRED MATERIAL: .............................. 0 - N/A

DESIGN TYPE: ........................ 0 - N/A

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 0.00 FT (0.00 M)

(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)

(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 0NNN

(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB

(75B) WORK DONE BY: ............. 1 - CONTRACT

(76) IMPROVEMENT LENGTH: ..

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

8 - Stable; scour above top of fo

3 - CONSTRUCTION

B - MAJOR

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

Flood event in 2010 washed out east embankment. Approach was reconstructed and wingwall were added to abutments in 2013.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:81�02'36.50 http:37�45'52.00

APPENDIX STRUCTURE NO. 4780-015P

PHOTOGRAPHS STRUCTURE NO. 4780-015P

PHOTO #1 - LOOKING EAST TOWARD TRAIL PARKING

FLOW

PHOTO #2 - SOUTH (UPSTREAM) SIDE

PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING WEST; NOTE SOME

RECENTLY REPLACED TIMBER RUNNERS, AND OTHERS EXHIBITING

ADVANCED DECAY

PHOTO #4 - POTHOLES AND WATER PONDING ON EAST APPROACH

PHOTO #5 - DECAY AND FULL SECTION LOSS

OF TIMBER RUNNER NEAR SOUTH CURBLINE

PHOTO #6 - DECAY OF TIMBER RUNNERS AT

VARIOUS LOCATIONS

PHOTO #7 - DECAY OF TIMBER RUNNER AT

NORTHEAST CORNER; NOTE ALSO TYPICAL

SOIL ACCUMULATION ALONG CURBS

PHOTO #8 - BROKEN SOUTH TIMBER CURB AT

ANCHORAGE

PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING EAST, NOTE

TYPICAL PAINT DETERIORATION AND RUSTING OF STRUCTURAL

STEEL

PHOTO #10 - CLOSE UP OF A STEEL GIRDER; NOTE PEELING OF PAINT

AND MINOR RUSTING

PHOTO #11 - LOOSE ANCHOR BOLT CONNECTING TIMBER DECK

PLANK TO TOP FLANGE OF BEAM AT SOUTHEAST CORNER

PHOTO #12 - HORIZONTAL TEAR ON INSIDE VERTICAL STIFFENER FOR

BEAM #1 NEAR EAST END

PHOTO #13 - TYPICAL RUSTING OF BEARING PLATES, BEARING PLATE

AT EAST END OF SOUTH EXTERIOR BEAM SHOWN; NOTE DEBRIS ON

BEARING SEATS

PHOTO #14 - GENERAL VIEW OF WEST ABUTMENT

PHOTO #15 - CRACKING AND STAINING ON NORTH SIDE OF WEST

ABUTMENT BACKWALL; NOTE FALLEN PIECE OF TIMBER

PHOTO #16 - CRACKING WITH EFFLORESCENCE ON SOUTH SIDE OF

WEST ABUTMENT BACKWALL

PHOTO #17 - GENERAL VIEW OF EAST ABUTMENT

PHOTO #18 - DIAGONAL CRACK AT SOUTH END OF EAST ABUTMENT

BACKWALL (PHOTO FROM 11/8/13 INSPECTION)

PHOTO #19 - GENERAL VIEW OF NORTHEAST WINGWALL; NOTE

CRACKS WITH EFFLORESCENCE BELOW WEEP HOLES

PHOTO #20 - LOOKING UPSTREAM FROM STRUCTURE

PHOTO #21 - LOOKING DOWNSTREAM FROM STRUCTURE

File details come from the government source that posted it. Updated .