Drawngs Set 3.pdf
PDF 515 KB Posted
- Solicitation number
- 36C24622B0003
About this file
This document provides a presolicitation notice for project 558-17-207 to install security fencing at the Durham VA Medical Center in Durham, North Carolina. The Department of Veterans Affairs requires a contractor to provide all administration, labor, materials, tools, equipment, transportation, permits, licenses, and qualified supervision for the installation of security fencing around the medical center campus. The project will be a total service-disabled veteran-owned small business set-aside with an anticipated NAICS code of 238990 and size standard of $16.5 million. Interested parties should register on SAM.gov and VetBiz.gov to receive notification of the solicitation issuance on or around December 9, 2021. Questions may be directed to the contracting specialist Guy K. Brooks by email only.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24622B0003 0002.docx | DOCX document | |
| Drawings Set 2.pdf | ||
| 36C24622B0003 0001.docx | DOCX document | |
| Drawngs Set 7.pdf | ||
| Drawngs Set 1.pdf | ||
| Attachment A - Itemized Schedule of Values Cost Breakdown.xlsx | XLSX spreadsheet | |
| Drawngs Set 5.pdf | ||
| Drawngs Set 4.pdf | ||
| Drawngs Set 6.pdf | ||
| 36C24622B0003.docx | DOCX document | |
| Specifications.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(8)#5
(16)#7
4'
6" M
IN
4" M
IN
9'
M A
X
BRICK SEE ARCH.
PRECAST CAP
SEE ARCH AND
NOTE 4
MIN
2" COVER
M
IN
2" C
O V
E R
C
LA
S S
B S
P
LI
C E
T Y
P
S301
3" COVER MIN.
3" C
O V
E R
M
IN
2" C
LR
(8)#5 EQUALLY SPACED
(18)#7 EQUALLY SPACED
#3 SPIRAL TIES
WITH 2 1/4" PITCH
#3 TIES @ 10" O/C MAX
1'
1'
5/ 8"
3' - 0" ø
1' - 3"
T Y
P
2" C
LR
FACE OF BRICK
SEE ELEVATION FOR
FOOTING REBAR
(12)#5 EQUALLY SPACED
4' - 0"
4'
1'
- 4
1/ 2"
1'
/2
11 1/2"
11 1/2"
1' - 6 1/2"
1' - 6"
#3 TIES @ 10" O/C MAX
TYP2"
C
LR
FACE OF BRICK
(12)#5
BRICK SEE ARCH.
PRECAST CAP
SEE ARCH AND
NOTE 4
2" COVER MIN
2" C
O V
E R
M
IN
1'
1'
0" M
IN
9'
M
A X
S301
#3 TIES @ 10" O/C MAX
2 TIES IN FOOTING
(5)#5 EACH WAY
EQUALLY SPACED
TOP AND BOTTOM
3" C
LR
CLR
3"
STD HOOK TYP
2" C
LR
PLUMBING/
UTILITY LINE
EXISTING OR NEW
FOUNDATION
FINISH GRADEWALL OR COLUMN, SEE PLAN
NEW FOOTINGS, PLUMBING LINES, ETC. SHALL BE INSTALLED SUCH THAT THEY ARE
ABOVE THE TRAPEZOID CREATED BELOW AND ADJACENT FOOTING WITH SIDES NO
STEEPER THAN 1 VERTICAL TO 2 HORIZONTAL.
CONTRACTOR NOTE:
T/GRADE
SEE CIVIL
SUBSEQUENT PROPOSED
FOUNDATION, SEE PLAN
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
A
B
C
D
E
F
CONCRETE DETAILS INSTALL SECURITY FEATURES
VA MEDICAL CENTER, DURHAM, NC
S301
558-17-207
07/06/2020
BID DOCUMENTS
DCASLM
1" = 1'-0"S301
1 TYPICAL FENCE COLUMN P1
1" = 1'-0"S301
3 SECTION AT TYP. FENCE AND COLUMN
1" = 1'-0"S301
4 SECTION AT CORNER FENCE COLUMN
1" = 1'-0"S301
2 TYPICAL CORNER FENCE COLUMN P-2
NOTES:
1. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMISSION OF SHOP DRAWINGS FOR REVIEW.
2. REFER TO THE SITE PLAN FOR LOCATIONS OF PIERS.
3. DO NOT DAMAGE BELOW GRADE UTILITIES AND PIPING DURING INSTALLATION OF NEW WORK.
LOCATE ALL UTILITIES AND PIPING AS REQUIRED TO INSTALL NEW WORK.
4. CONNECTION OF PRECAST CAP TO CONCRETE PIER SHALL BE BY THE MANUFACTURER.
CONTRACTOR SHALL COORDINATE CONNECTION REQUIREMENTS PRIOR TO SUBMITTING SHOP
DRAWINGS FOR REVIEW.
5. DESIGN OF FENCING AND CONNECTIONS OF FENCING TO THE PIER SHALL BE BY THE FENCING
MANUFACTURER FOR THE REQUIRED LOADINGS SHOWN ON SHEET S001.
3/4" = 1'-0"S301
5 TYPICAL FOOTING INSTALLATION DETAIL
CONCRETE REBAR LAP SPLICE SCHEDULE
Key Name BAR SIZE CLASS
NORMAL WEIGHT CONCRETE 28 DAY f'c (PSI)
4,000
1 #6 or Smaller B 49 Dia.
2 #7 or Larger B 62 Dia.
S501
S501
SIM
2" 2"
2" 2"
FENCE POST BY
FENCE MFG
EXIST
CONCRETE
BEAM
EXIST.
CONCRETE
WALL
M
IN
6"
M
IN
6"
S E
E A
R C
H
M
IN6"
1 1/2" 5 1/2" 1 1/2"
1/2"x4"x0'-8 1/2" PLATE W/ LONG
SLOTTED VERTICAL HOLES.
OMIT SLOTTED HOLES AT SIM
CONDITION
(2) 3/8"Øx2 3/4" EMBED HILTI KWIK BOLT
ANCHORS CENTERED IN SLOT.
2" 2"
BY FENCE
MFG
EXIST.
BEAM
FENCE POST BY
FENCE MFG
M
IN6"
1 1/2" 5 1/2" 1 1/2"
1/2"x4"x0'-8 1/2" PLATE
(2) 3/8"Øx2 3/4" EMBED HILTI KWIK BOLT
2" 2"
BY FENCE
MFGEXIST.
BEAM
FENCE POST BY
FENCE MFG
M
IN6"
S501
S501
2"2"
2" 2"
FENCE POST BY
FENCE MFG
EXIST
CONCRETE
BEAM
EXIST.
CONCRETE
WALL
MIN.
6"
S E
E A
R C
H
3380 Trickum Road
Woodstock, GA. 30188 770-517-5507 voice 770-517-5508 fax
Bldg. 500, Ste. 100 www.ieiusa.com
INCORPORATED
INNOVATIVE
ENGINEERING
Veterans Affairs
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
Date:
Drawing Title:
Approved: Project Director
Project Title:
1 2 3 4 5 6 7 8 9
590 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date CheckedFULLY SPRINKLERED
STAMP
STE. 200
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
F ile
P a th
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
Drawn
Revisions:
A
B
C
D
E
F
STEEL DETAILS INSTALL SECURITY FEATURES
VA MEDICAL CENTER, DURHAM, NC
S501
558-17-207
07/06/2020
BID DOCUMENTS
DCASLM
1" = 1'-0"S501
SECTION AT
FENCE POST CONNECTION
1" = 1'-0"S501
3 FENCE POST CONNECTION DETAIL
1" = 1'-0"S501
FENCE POST CONNECTION DETAIL
TO UNDERSIDE OF EXISTING BEAM 1" = 1'-0"S501
SECTION AT
FENCE POST CONNECTION
NOTES:
1. DO NOT DAMAGE EXISTING CONCRETE REINFORCING DURING ANCHOR INSTALLATION.
CONTRACTOR SHALL LOCATE EXISTING REINFORCING THROUGH NON-DESTRUCTIVE
MEANS PRIOR TO SUBMISSION OF SHOP DRAWINGS FOR REVIEW.
2. ALL ANCHORS SHALL BE GALVANIZED
3. REFER TO ARCHITECTURAL DRAWINGS FOR ANCHOR LOCATIONS
4. REFER TO SPECIFICATIONS FOR ANCHOR PLATE FINISH
| Drawings 4 |
| Drawings 5 |
| Drawings 6 |
File details come from the government source that posted it. Updated .