Drawings.pdf
PDF 3 MB Posted
- Attached to
- Z2DA--660-22-114 Non-Sterile Compounding Room Update Federal contract opportunity
- Solicitation number
- 36C25922Q0417
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Update Non Sterile Compounding Room Specs V2.docx | DOCX document | |
| 36C25922Q0417 RFI.docx | DOCX document | |
| 36C25922Q0417 0002.docx | DOCX document | |
| S04 -Site Visit Meeting Doc.docx | DOCX document | |
| Past Performance Questionnaire.docx | DOCX document | |
| Walkthrough Attendance Sheet.pdf | ||
| 36C25922Q0417 0001.docx | DOCX document | |
| Specs.docx | DOCX document | |
| Solicitation_Instructions to Offerors - Under SAP.docx | DOCX document | |
| 36C25922Q0417_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Low: 0% - 50%Project Manager: Alonso Bernal
Identify Hazards Evaluator Is Hazard Likely?
H-M-L
Severity H-M-L
Mitigation Needed?
Y/N Mitigation Strategies
• Inspect, and document as needed, tools prior to use.
Hand and Power Tools
AB H M Y
• Only double insulated or neutrally grounded tools can be used.
• Properly store tools when not in use.
• All guards to be in place and in good condition.
• Develop, communicate, and follow a written plan before performing electrical work to maximize safety.
• Ensue ALL electrical circuits and circuit breakers are identified properly before troubleshooting or performing electrical work.
• Identify hazards and establish safety limits of approach.
Electrical AB M H Y
• All work shall comply with NFPA 70 most recent edition.
• Verify code compliance prior to energizing.
• Inspect electrical cords before use.
• Do not use cords with damaged insulation or daisy chain them. Use GFCIs.
• Persons conducting electrical work should have the knowledge, skills and abilities necessary to perform the task.
• Open circuit breaker that supplies power.
• Open visual disconnects.
Lockout / Tagout Electrical
AB M M Y
• Lock-out and tag-out visual disconnect yourself and never rely on someone to do this for you.
• VA first lock on/last lock off.
• Follow full Engineering LO/TO SOP.
• Include VA Operations & Maintenance in LO/TO plans.
Lockout / Tagout Plumbing AB M M Y
• VA first lock on/last lock off.
• Follow full Engineering LO/TO SOP.
• Include VA Operations & Maintenance in LO/TO plans.
Mitigation Strategies
Implemented?
Comments
Date: 04/07/2022
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
CONSTRUCTION SAFETY RISK
ASSESSMENT CHECKLIST DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
PASADENA, MD 21122
A/E: N/A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
CONSTRUCTION SAFETY RISK
ASSESSMENT CHECKLIST DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
Attachment B Infection Control Risk Assessment
Project Name / EWO Description:
Location of Activity:
Project Manager:
Project Manager Phone #: 801.582.1565 X4586
Alonso Bernal
Bldg. 1 Room GB01B-1
Update Non-Sterile Compounding Room
Matrix of Precautions for Construction Renovation
REVISED (1.5.22)
Start Date:
Contractor:
Contractor Phone #:
STEP #1: Using the following table, identify the Type of Construction Project Activity (Type A-D)
A) Type A
CONSTRUCTION ACTIVITY TYPES:
Inspection and Non-Invasive Activities, includes but is not limited to one or more of the following:
(1) removal of ceiling tiles for visual inspection only, e.g., limited to 1 tile per 50 square
(2) painting (but not sanding) (3) wallcovering (4) electrical trim work (5) minor plumbing,
(6) activities which do not generate dust or require cutting of walls or access to ceilings other than for visual inspection
Type B Small scale, short duration activities which create minimal dust. Includes, but is not limited to one or more of the following:
(1) access to chase spaces (2) cutting of walls or ceilings where dust migration can be controlled (3) installation of telephone and computer cabling
Type C Any work which generates a moderate to high level of dust or requires demolition or removal of any fixed building components or assemblies.
Includes, but is not limited to one or more of the following:
(1) sanding of walls for painting or wall covering (2) removal of floorcoverings (3) removal of ceiling tiles (4) casework (5) new wall construction (6) minor duct work
(7) electrical work above ceilings (8) major cabling activities (9) any activity which cannot be restored back to original state within a single workshift
Type D Major demolition and construction projects. Includes, but is not limited to one or more of the following:
(1) requires heavy demolition (2) removal of a complete cabling system (3) new construction connected to occupied area
STEP #2: Using the following table, identify the Risk Groups that will be affected. If more than one group will be affected, select the higher risk group.
B) INFECTION CONTROL RISK GROUPS
Group 1
Low Risk
Office Areas or
Nonmedical associated space
Laboratories
3 West
Acute Medicine (2 East, 2 North)
B.2
B.3 Inpatient Mental Health Ward
Canteen Kitchen
Cardiology
Decontamination
Dental
Distribution
G.I. Lab Hoptel
Group 2
Medium Risk Imaging
Laundry
Nuclear Medicine
Out Patient Clinics
Patient Kitchen & Dining
Out Patient Surgery
Pharmacy (In & Out Patient)
PT / OT
Public Corridor (patient activity)
Pulmonary / Bronchoscopy
Telemetry
STEP 3: Determine Class of Precautions (I, II, III or IV) Using Matrix Below:
ICN must be consulted when the assessment indicates that Class II, III, or IV precautions are required.
TYPE A
Group 1
Group 2
Group 3
Group 4 I
I
I
II
TYPE B
II
III/IV
II
II
Construction Project Type Risk Group TYPE C
III/IV
III/IV
III
II
TYPE D
III/IV
IV
IV
IV
Group 3 High Risk
Emergency Room (ECU)
Post Antesthesia Care
All ICUs
All OR's
Sterile Processing
Ambulatory Medicine Unit (2 West)
Cardiac Cath/Angiography
Pharmacy IV Prep (Inpatient)
Dialysis Unit
Group 4 Highest Risk
Project # / EWO #:
4/1/2022 Estimated Duration:
ICN:
ICN Phone #: 801 582 1565 ex 1708
Diane Franke
20 construction days
660-22-114
Description of Required Infection Control Precautions by Class
During Construction Project Upon Completion of Project
1 Execute work by methods to minimize raising dust. 1 Clean work area upon completion of task.
2 Immediately replace a ceiling tile displaced for visual inspection
3 Contaminated materials kept away from patient transportation route and storage for clean supplies.
4 Worker traffic routes should minimize contact with patients.
In Addition to Class I Precautions:
1 Consult Infection Control Nurse prior to beginning work.
2 Educate VA staff regarding construction activity.
3 Block and seal air vents before starting.
1 Wipe work surfaces with cleaner/disinfectant.
2 Contain construction waste before transport in tightly covered containers.
3 Wet mop and/or vacuum with HEPA filtered vacuum before leaving work area.
4 Coordinate air filter maintenance with Operations. 4 Use only designated elevators (e.g. utility) for debris removal.
5 Seal unused doors with duct tape. 5 Remove and replace wet ceiling tiles.
6 Place dust mat at entrance and exit of work area
In Addition to Class I and II Precautions:
1 Consult Infection Control Nurse prior to beginning work.
2 Complete all critical barriers i.e. sheetrock, plywood, plastic, to seal area from non work area or implement control cube method (cart with plastic covering and sealed connection to work site with HEPA vacuum for vacuuming prior to exit) before construction begins.
3 Maintain negative air pressure within work site utilizing HEPA equipped air filtration units.
4 Contain construction waste before transport in tightly covered containers.
5 Cover transport receptacles or carts. Tape covering unless solid lid.
In Addition to Class I and II and III Precautions:
1 Do not remove barriers from work area until completed project is inspected by the owner’s Safety Department and Infection Prevention & Control Department and thoroughly cleaned by the owner’s Environmental Services Department.
2 Remove barrier materials carefully to minimize spreading of dirt and debris associated with construction.
3 Vacuum work area with HEPA filtered vacuums.
4 Wet mop area with cleaner/disinfectant.
5 Upon completion, restore/clean HVAC system as needed where work was performed.
6 Water lines flushed at site and adjacent areas.
IP Signature: Diane Franke, Infection Prevention
1 Consult Infection Control Nurse prior to beginning work.
2 Relocate patients to area remote from construction area.
Date Reviewed: 12/16/21. Revised 1/5/22. Final 1/7/22.
Physicial ICRA needs to be signed at work site.
C
LA
SS
IV
C
LA
SS
II
I C
LA
SS
II
C
LA
SS
I
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
INFECTION CONTROL
RISK ASSESSMENT DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
PHARMACY COMPOUNDNG DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
PHARMACY COMPOUNDING ROOM | EXISTING CONDITIONS
Scale: 1/4" = 1' 0"
PHARMACY COMPOUNDING ROOM | CONCEPT REDESIGN
Scale: 1/4" = 1' 0"
PHARMACY COMPOUNDING ROOM | FLOORING PLAN
Scale: 1/4" = 1' 0"
PHARMACY COMPOUNDING ROOM | COUNTERTOP PLAN
Scale: 1/2" = 1' 0"
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
PASADENA, MD 21122
A/E: N/A
AutoCAD SHX Text s
AutoCAD SHX Text
30" W FULL HEIGHT FRIDGE (NIC)
AutoCAD SHX Text 48"W x 24"D WORK STATION (N.I.C.)
AutoCAD SHX Text
UNDERCAB FRIDGE (NIC)
AutoCAD SHX Text
34" W FIRE HAZARD STORAGE
AutoCAD SHX Text
EXISTING SPRINKLER
AutoCAD SHX Text
EXISTING SPRINKLER
AutoCAD SHX Text
TALL STORAGE (N.I.C.)
AutoCAD SHX Text
AC UNIT
AutoCAD SHX Text
TRASH
AutoCAD SHX Text
ADA ACCESSIBLE SINK
AutoCAD SHX Text
14"D UPPER CABS
AutoCAD SHX Text
LOCKABLE BASE CAB
AutoCAD SHX Text
TALL STORAGE (N.I.C.)
AutoCAD SHX Text
FAN UNIT TO BE CONCEALED ABOVE GRID CEILING
AutoCAD SHX Text s
AutoCAD SHX Text
FULL HEIGHT FRIDGE
AutoCAD SHX Text
TALL LOCK CABINET "FLAMMABLE"
AutoCAD SHX Text
WORK STATION
AutoCAD SHX Text
LOW LOCK CABINET "FLAMMABLE"
AutoCAD SHX Text
WIRE SHELVING
AutoCAD SHX Text
WIRE SHELVING
AutoCAD SHX Text
UNDERCAB FRIDGE
AutoCAD SHX Text
WALL MOUNTED ADJ SHELVES
AutoCAD SHX Text
WIRE SHELVING
AutoCAD SHX Text
38"H WORKSURFACE
AutoCAD SHX Text
EXISTING SPRINKLER
AutoCAD SHX Text
EXISTING SPRINKLER
AutoCAD SHX Text 4'-7"
AutoCAD SHX Text COUNTERTOP CONCEPT PLAN FIELD VERIFY ALL DIMENSIONS MATERIAL: STAINLESS STEEL COUNTERTOP WITH 12"H INTEGRATED BACK SPLASH FABRICATION NOTE: POLISH & GRIND ALL WELDS SMOOTH VERIFY ALL PLUMBING FIXURES PRIOR TO FABRICATING COUNTERTOP
AutoCAD SHX Text
REVERSE OSMOSIS
AutoCAD SHX Text
WIDE-SPREAD FAUCET
AutoCAD SHX Text
EYEWASH
AutoCAD SHX Text 10'-8"
AutoCAD SHX Text 2'
AutoCAD SHX Text
INSTALL NEW RUBBER FLOORING
AutoCAD SHX Text
INSTALL NEW TRANSITION STRIP
Manufacturer Material Color Hardware Finish Notes Millwork NeoCase Series High Pressure Laminate Willow Grey (WGR) 4" Arch Pull Nickel Or Approved Alternate
Flooring Roppe, Envire Series Rubber Sheet Natural (S122) N/A Matte Or Approved Alternate Roppe, Envire Series Transition Strip Natural (S122) Part #177 Matte Or Approved Alternate
Countertop N/A Stainless Steel 12 gauge #304 2B N/A Polished Polish smooth all welds.
Paint Sherwin Williams Latex Paint Natural Choice SW7011 N/A Satin Or Approved Alternate
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
PHARMACY COMPOUNDNG DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
PHARMACY COMPOUNDING ROOM | CONCEPT ELEVATIONS
Scale: 1/2" = 1' 0"
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
PASADENA, MD 21122
A/E: N/A
RECOMMENDED FLOORING TRANSITION STRIPPHARMACY COMPOUNDING ROOM | FINISH SCHEDULE
AutoCAD SHX Text 2'-6 "12"
AutoCAD SHX Text 5'-1"
AutoCAD SHX Text 8'
AutoCAD SHX Text
OPEN FOR UNDER CABINET FRIDGE
AutoCAD SHX Text
PULL-OUT SHELVING TYP AT BASE CABS
AutoCAD SHX Text
FULL HEIGHT STAINLESS BACKSPLASH
AutoCAD SHX Text
30" W FRIDGE (NIC)
AutoCAD SHX Text
SPRINKLER HEAD *KEEP UNOBSTRUCTED
AutoCAD SHX Text 4"
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 2'-8"
AutoCAD SHX Text
2 " FILLER14" FILLER
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 2'
AutoCAD SHX Text
1" FILLER
AutoCAD SHX Text 3'
AutoCAD SHX Text
FAUCET
AutoCAD SHX Text
EYE WASH
AutoCAD SHX Text
REVERSE OSMOSIS ABLE TO PIVOT TO ADJACENT SINK
AutoCAD SHX Text 10'-8"
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text 8'
AutoCAD SHX Text 3'
AutoCAD SHX Text 2'
AutoCAD SHX Text 2'-11"
AutoCAD SHX Text 2'-11"
AutoCAD SHX Text
ADJUSTABLE SHELVING TYP AT UPPER CABS
AutoCAD SHX Text 8'-11"
AutoCAD SHX Text 2'-11 "34"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 3'-5"
AutoCAD SHX Text
REFER TO SECTION DETAIL
AutoCAD SHX Text
DRAWER
4"
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
PHARMACY COMPOUNDNG DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANT
VAMC SALT LAKE CITY, UT
660-22-114
Project Director
4/22/2022 A.Gonzales EChambers
Revisions: Date:
SECTION VIEW | ADA SINK CABINET
Scale: 1" = 1' 0"
PHARMACY COMPOUNDNG
LRS FEDERAL LLC
8221 RITCHIE HWY SUITE 300
PASADENA, MD 21122
A/E: N/A
SECTION VIEW | UPPER CABINET
Scale: 1" = 1' 0"
SECTION VIEW | LOWER CABINET
Scale: 1" = 1' 0"
SECTION VIEW | LOWER CABINET WITH DOORS
Scale: 1" = 1' 0"
AutoCAD SHX Text 1'-11"
AutoCAD SHX Text 2'-11"
AutoCAD SHX Text
OPEN TO WALL
AutoCAD SHX Text
FLOOR LINE
AutoCAD SHX Text
REMOVABLE FRONT PANEL
AutoCAD SHX Text
FALSE FRONT
AutoCAD SHX Text
TOP ASSY. HARDWARE
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text
TOP
AutoCAD SHX Text
MOUNTING BRACKET
AutoCAD SHX Text
ADJUSTABLE SHELVES
AutoCAD SHX Text
PRE-DRILLED PATTERN
AutoCAD SHX Text
BACK
AutoCAD SHX Text
HINGE
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text 1'-2"
AutoCAD SHX Text 3'
AutoCAD SHX Text 3'
AutoCAD SHX Text 4"
AutoCAD SHX Text
TOP
AutoCAD SHX Text
PULL OUT SHELVES ON TRACKS
AutoCAD SHX Text
LEVELER
AutoCAD SHX Text
HINGE
AutoCAD SHX Text 1'-11 "12"
AutoCAD SHX Text
TOE KICK
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text 3'
AutoCAD SHX Text
TOP
AutoCAD SHX Text
DRAWER
AutoCAD SHX Text
PULL OUT SHELVES ON TRACKS
AutoCAD SHX Text
LEVELER
AutoCAD SHX Text
HINGE
AutoCAD SHX Text 1'-11 "12"
AutoCAD SHX Text
TOE KICK
AutoCAD SHX Text
HARDWARE
4"
| Sheets and Views |
| Pharmacy Compounding-CSRA |
| Pharmacy Compounding-CSRA (2) |
| Pharmacy Compounding-ICRA |
| Pharmacy Compounding-ILSM |
| Pharmacy Compounding-v3_1of3 |
| Pharmacy Compounding-v3_2of3 |
| Pharmacy Compounding-v3_3of3 |